Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int J Mol Sci ; 22(6)2021 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-33805752

RESUMEN

Graphene coating on the cobalt-chromium alloy was optimized and successfully carried out by a cold-wall chemical vapor deposition (CW-CVD) method. A uniform layer of graphene for a large area of the Co-Cr alloy (discs of 10 mm diameter) was confirmed by Raman mapping coated area and analyzing specific G and 2D bands; in particular, the intensity ratio and the number of layers were calculated. The effect of the CW-CVD process on the microstructure and the morphology of the Co-Cr surface was investigated by scanning X-ray photoelectron microscope (SPEM), atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Nanoindentation and scratch tests were performed to determine mechanical properties of Co-Cr disks. The results of microbiological tests indicate that the studied Co-Cr alloys covered with a graphene layer did not show a pro-coagulant effect. The obtained results confirm the possibility of using the developed coating method in medical applications, in particular in the field of cardiovascular diseases.


Asunto(s)
Aleaciones de Cromo/química , Materiales Biocompatibles Revestidos/química , Grafito/química , Animales , Factores de Coagulación Sanguínea/metabolismo , Plaquetas/citología , Plaquetas/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Aleaciones de Cromo/farmacología , Materiales Biocompatibles Revestidos/farmacología , Eritrocitos/efectos de los fármacos , Humanos , Ensayo de Materiales/métodos , Ratones , Células 3T3 NIH , Tiempo de Tromboplastina Parcial , Activación Plaquetaria/efectos de los fármacos , Cultivo Primario de Células , Propiedades de Superficie , Volatilización
2.
Materials (Basel) ; 15(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35009511

RESUMEN

The microstructure, revealed by X-ray diffraction and transmission Mössbauer spectroscopy, magnetization versus temperature, external magnetizing field induction and mechanical hardness of the as-quenched Fe75Zr4Ti3Cu1B17 amorphous alloy with two refractory metals (Zr, Ti) have been measured. The X-ray diffraction is consistent with the Mössbauer spectra and is characteristic of a single-phase amorphous ferromagnet. The Curie point of the alloy is about 455 K, and the peak value of the isothermal magnetic entropy change, derived from the magnetization versus external magnetizing field induction curves, equals 1.7 J·kg-1·K-1. The refrigerant capacity of this alloy exhibits the linear dependence on the maximum magnetizing induction (Bm) and reaches a value of 110 J·kg-1 at Bm = 2 T. The average value of the instrumental hardness (HVIT) is about 14.5 GPa and is superior to other crystalline Fe-based metallic materials measured under the same conditions. HVIT does not change drastically, and the only statistically acceptable changes are visibly proving the single-phase character of the material.

3.
J Funct Biomater ; 13(4)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36412886

RESUMEN

The continuous development of novel materials for biomedical applications is resulting in an increasingly better prognosis for patients. The application of more advanced materials relates to fewer complications and a desirable higher percentage of successful treatments. New, innovative materials being considered for biomedical applications are metallic alloys with an amorphous internal structure called metallic glasses. They are currently in a dynamic phase of development both in terms of formulating new chemical compositions and testing their properties in terms of intended biocompatibility. This review article intends to synthesize the latest research results in the field of biocompatible metallic glasses to create a more coherent picture of these materials. It summarizes and discusses the most recent findings in the areas of mechanical properties, corrosion resistance, in vitro cellular studies, antibacterial properties, and in vivo animal studies. Results are collected mainly for the most popular metallic glasses manufactured as thin films, coatings, and in bulk form. Considered materials include alloys based on zirconium and titanium, as well as new promising ones based on magnesium, tantalum, and palladium. From the properties of the examined metallic glasses, possible areas of application and further research directions to fill existing gaps are proposed.

4.
Materials (Basel) ; 15(20)2022 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-36295280

RESUMEN

The aim of the present work is to study the phase composition, microstructure and magnetocaloric effect of binary Gd100-xPbx (where x = 5, 10, 15 and 20) alloys. The XRD and SEM/EDX analysis confirmed a biphasic structure built by Gd(Pb) and Gd5Pb3 phases. The analysis of M vs. T curves showed the evolution of the Curie point of recognized phases. The temperature dependences of magnetic entropy change revealed two maxima corresponding to the recognized phases. The analysis of the exponent n (ΔSMmax = C(Bmax)n) confirmed the multiphase composition of the produced alloys. The same behavior was also observed in investigations of mechanical properties.

5.
Materials (Basel) ; 14(1)2021 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-33406605

RESUMEN

The aim of the paper is to present a study of the magnetocaloric effect and the nature of phase transition in the Gd80Ge15Si5 (S1), Gd75Ge15Si5Ni5 (S2), Gd75Ge15Si5Pr5 (S3) and Gd75Ge15Si5Nd5 (S4) alloys. The magnetic entropy changes determined for studied samples, under external magnetic field ~3T, were 11.91, 12.11, 5.08 and 4.71 J/(kg K) for S1, S2, S3 and S4, respectively. The values of refrigerant capacity (under ~3T) were 164, 140, 160 and 140 J/kg for S1, S2, S3 and S4, respectively. The first order phase transition was detected for samples S1 and S2, while specimens S3 and S4 manifested the second order phase transition at the Curie point (TC). The analysis of temperature evolution of the exponent n (ΔSM = C·(Bmax)n) showed the validity of this method in detecting either the first or the second order phase transition and the structural transition. The analysis of critical behavior was carried out for samples S3 and S4. The critical exponents and precise TC values were calculated. The ascertained critical exponents were used to determine the theoretical value of the exponent n, which corresponded well with experimental result.

6.
Materials (Basel) ; 15(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35009398

RESUMEN

Microstructure, mechanical properties, corrosion resistance, and biocompatibility were studied for rapidly cooled 3 mm rods of Zr40Ti15Cu10Ni10Be25, Zr50Ti5Cu10Ni10Be25, and Zr40Ti15Cu10Ni5Si5Be25 (at.%) alloys, as well as for the reference 316L stainless steel and Ti-based Ti6Al4V alloy. Microstructure investigations confirm that Zr-based bulk metallic samples exhibit a glassy structure with minor fractions of crystalline phases. The nanoindentation tests carried out for all investigated composite materials allowed us to determine the mechanical parameters of individual phases observed in the samples. The instrumental hardness and elastic to total deformation energy ratio for every single phase observed in the manufactured Zr-based materials are higher than for the reference materials (316L stainless steel and Ti6Al4V alloy). A scratch tester used to determine the wear behavior of manufactured samples and reference materials revealed the effect of microstructure on mechanical parameters such as residual depth, friction force, and coefficient of friction. Electrochemical investigations in simulated body fluid performed up to 120 h show better or comparable corrosion resistance of Zr-based bulk metallic glasses in comparison with 316L stainless steel and Ti6Al4V alloy. The fibroblasts viability studies confirm the good biocompatibility of the produced materials. All obtained results show that fabricated biocompatible Zr-based materials are promising candidates for biomedical implants that require enhanced mechanical properties.

7.
Materials (Basel) ; 13(13)2020 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-32605283

RESUMEN

The temperature dependence of magnetocrystalline anisotropy was investigated in detail for the polycrystalline Ni50Mn25Ga25, Ni50Mn25Ga20Ti5 and Ni50Mn25Ga20Gd5 ferromagnetic shape memory alloys in the temperature range of 50-400 K. The effective anisotropy constant was estimated from a series of high field magnetization curves based on the fitting procedure according to the law of approach to magnetic saturation. The low temperature martensitic phase was found to have a significantly higher anisotropy energy in comparison to a high temperature austenitic phase, which was observed through a sudden, distinct drop of anisotropy energy. The calculated values of the effective anisotropy constant were comparable to the results published by other authors. Moreover, the strong influence of chemical composition on the first-order phase transition and the second-order ferromagnetic to the paramagnetic transition was revealed. Finally, the strong coupling between the temperature dependence of the coercive field and the temperature dependence of magnetocrystalline anisotropy was also shown and discussed in the present study.

8.
Materials (Basel) ; 13(24)2020 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-33348588

RESUMEN

The paper presents studies of microstructure, magnetic and corrosion properties of the Gd58Ge20Si22, Gd56Ge20Si22Co2, Gd56Ge20Si22Ti2 and Gd56Ge20Si22Cr2 (at.%) alloys after isothermal heat treatment at 1450 K for 2 h. The structure investigations of the produced materials performed by X-ray diffraction show the presence of Gd5Ge2Si2-type phase in all investigated samples. DC and AC magnetic measurements confirmed that the Curie temperature depends on the chemical composition of the produced alloys. From M(T) characteristics, it was found that the lowest Curie point (TC = 268 K) was estimated for the Gd58Ge20Si22 sample, whereas the highest value of the Curie temperature (TC = 308 K) was for the Gd56Ge20Si22Cr2 alloys. Moreover, the GdGeSi alloy without alloying additions shows the highest magnetic entropy change |ΔSM| = 15.07 J⋅kg-1⋅K-1 for the maximum magnetic field of 2 T. The maximum |ΔSM| measured for the Gd56Ge20Si22 with the addition of Co, Ti or Cr for the same magnetic field was obtained in the vicinity of the Curie point and equals to 2.92, 2.73 and 2.95 J⋅kg-1⋅K-1, respectively. Electrochemical studies of the produced materials for 60 min and 55 days exposure in 3% NaCl solution show that the highest stability and corrosion resistance were exhibited the sample with added of Ti.

9.
Materials (Basel) ; 13(8)2020 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-32340390

RESUMEN

Sore, infected wounds are a major clinical issue, and there is thus an urgent need for novel biomaterials as multifunctional constituents for dressings. A set of biocomposites was prepared by solvent casting using different concentrations of carboxymethylcellulose (CMC) and exfoliated graphene oxide (Exf-GO) as a filler. Exf-GO was first obtained by the strong oxidation and exfoliation of graphite. The structural, morphological and mechanical properties of the composites (CMCx/Exf-GO) were evaluated, and the obtained composites were homogenous, transparent and brownish in color. The results confirmed that Exf-GO may be homogeneously dispersed in CMC. It was found that the composite has an inhibitory activity against the Gram-positive Staphylococcus aureus, but not against Gram-negative Pseudomonas aeruginosa. At the same time, it does not exhibit any cytotoxic effect on normal fibroblasts.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA