Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Polymers (Basel) ; 16(6)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38543422

RESUMEN

Poly-L-lactic acid (PLLA) implants have been used for bone fixation for decades. However, upon insertion, they can cause a foreign body reaction (FBR) that may lead to complications. On 15 December 2023, a systematic review was conducted to search for articles on the PubMed, MeSH term, and Scopus databases using the keywords 'PLLA' and 'foreign body reaction'. The articles were reviewed not only for the question of FBR, its severity, and the manifestation of symptoms but also for the type of implant and its location in the body, the species, and the number of individuals included. A total of 71 original articles were identified. Of these, two-thirds reported on in vivo trials, and one-third reported on clinical applications. The overall majority of the reactions were mild in more than half of the investigations. Symptoms of extreme and extensive FBR mainly include osteolysis, ganglion cysts, and swelling. The localization of PLLA implants in bone can often result in osteolysis due to local acidosis. This issue can be mitigated by adding hydroxyapatite. There should be no strong FBR when PLLA is fragmented to 0.5-4 µm by extracorporeal shock wave.

2.
3D Print Med ; 10(1): 9, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38536566

RESUMEN

BACKGROUND: The responsible use of 3D-printing in medicine includes a context-based quality assurance. Considerable literature has been published in this field, yet the quality of assessment varies widely. The limited discriminatory power of some assessment methods challenges the comparison of results. The total error for patient specific anatomical models comprises relevant partial errors of the production process: segmentation error (SegE), digital editing error (DEE), printing error (PrE). The present review provides an overview to improve the general understanding of the process specific errors, quantitative analysis, and standardized terminology. METHODS: This review focuses on literature on quality assurance of patient-specific anatomical models in terms of geometric accuracy published before December 4th, 2022 (n = 139). In an attempt to organize the literature, the publications are assigned to comparable categories and the absolute values of the maximum mean deviation (AMMD) per publication are determined therein. RESULTS: The three major examined types of original structures are teeth or jaw (n = 52), skull bones without jaw (n = 17) and heart with coronary arteries (n = 16). VPP (vat photopolymerization) is the most frequently employed basic 3D-printing technology (n = 112 experiments). The median values of AMMD (AMMD: The metric AMMD is defined as the largest linear deviation, based on an average value from at least two individual measurements.) are 0.8 mm for the SegE, 0.26 mm for the PrE and 0.825 mm for the total error. No average values are found for the DEE. CONCLUSION: The total error is not significantly higher than the partial errors which may compensate each other. Consequently SegE, DEE and PrE should be analyzed individually to describe the result quality as their sum according to rules of error propagation. Current methods for quality assurance of the segmentation are often either realistic and accurate or resource efficient. Future research should focus on implementing models for cost effective evaluations with high accuracy and realism. Our system of categorization may be enhancing the understanding of the overall process and a valuable contribution to the structural design and reporting of future experiments. It can be used to educate specialists for risk assessment and process validation within the additive manufacturing industry.

3.
Pharmaceutics ; 15(9)2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37765150

RESUMEN

Implant-related infections are a significant concern in orthopedic surgery. A novel anti-infective implant coating made of bioresorbable polymer with silver nitrate was developed. A controlled release of silver ions into the vicinity of the prosthesis can be triggered on-demand by extracorporeal shock waves to effectively combat all clinically relevant microorganisms. Microscopy techniques were used to examine the effects of shock wave application on coated titanium discs. Cytotoxicity was measured using a fibroblast proliferation assay. The anti-infective effect was assessed by monitoring the growth curves of three bacterial strains and by conventional culture. Microscopic analysis confirmed surface disruption of the coatings, with a complete release of silver in the focus area after shock wave application. Spectrometry detected an increase in silver concentration in the surrounding of the discs that surpassed the minimum inhibitory concentration (MIC) for both S. epidermidis RP62A and E. coli ATCC 25922. The released silver demonstrated an anti-infective effect, significantly inhibiting bacterial growth, especially at 6% and 8% silver concentrations. Cytotoxicity testing showed decreasing fibroblast viability with increasing silver concentration in the coating, with 6% silver maintaining viability above 25%. Compared to a commonly used electroplated silver coating on the market, the new coating demonstrated superior antimicrobial efficacy and lower cytotoxicity.

4.
Pharmaceutics ; 15(12)2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38140011

RESUMEN

Bacterial biofilms on foreign surfaces are considered a primary cause of implant-related infections, which are challenging to treat. A new implant coating was developed, containing anti-infective silver within a biocompatible polymer carrier substance. In addition to its passive effect on the implant surface, highly concentrated anti-infective silver can be released as needed via the application of high-energy shock waves. This intervention could be applied transcutaneously in a clinical setting without the need for additional surgery. We investigated the inhibition of biofilm formation and the effectiveness of eradication after activation of the coating via shock waves in an in vitro biofilm model using Staphylococcus epidermidis RP62A. This was performed via scanning electron microscopy and quantitative microbiology. Additionally, we examined the cytotoxicity of the new coating on normal human fibroblasts and Saos-2 osteoblast-like cells, depending on the silver concentration. All studies were compared to uncoated titanium surfaces Ti6Al4V and a conventional electroplated silver coating. Cytotoxicity toward normal human fibroblasts and Saos-2 osteoblast-like cells increased with higher silver content but remained tolerable at 6%. Compared to uncoated Ti6Al4V and the electroplated silver coating, the new coating with a silver content of 4% and 6% exhibited a significant reduction in adherent bacteria by a factor of approximately 1000. This was also evident via microscopic examination of the surface morphology of the biofilms. Furthermore, following shock wave activation, no bacteria were detectable on either the implant or in the surrounding fluid after a 24 h period.

5.
Biomater Adv ; 138: 212917, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35913227

RESUMEN

An anti-infective bilayer implant coating with selectively activatable properties was developed to prevent biofilm formation and to support the treatment of periprosthetic infection as a local adjunct to current treatment concepts. In a first step, Ti6Al4V discs were coated with a permanent layer of Poly(l-lactide) (PLLA) including silver ions. The PLLA could be optionally released by the application of extracorporeal shock waves. In a second step, a resorbable layer of triglyceride (TAG) with incorporated antibiotics was applied. The second layer is designed for resorption within weeks. Prior to approval and clinical application, a comprehensive evaluation process to determine mechanical/physical and microbiological properties is obligate. To date, none of the existing test standards covers both drug-releasing and activatable coatings for orthopedic implants. Therefore, a comprehensive test concept was developed to characterize the new coating in a pilot series. The coatings were homogeneously applied on the Ti6Al4V substrate, resulting in an adhesion strength sufficient for non-articulating surfaces for PLLA. Proof of the extracorporeal shockwave activation of PLLA was demonstrated both mechanically and microbiologically, with a simultaneous increase of biocompatibility compared to standard electroplated silver coating. Wettability was significantly reduced for both layers in comparison to the Ti6Al4V substrate. Thus, potentially inhibiting biofilm formation. Furthermore, the TAG coating promoted cell proliferation and bacterial eradication. In conclusion, the testing concept is applicable for similar biopolymer coating systems. Furthermore, the extracorporeal activation could represent a completely new supportive approach for the treatment of periprosthetic joint infections.


Asunto(s)
Materiales Biocompatibles Revestidos , Plata , Biopolímeros/farmacología , Materiales Biocompatibles Revestidos/farmacología , Ensayo de Materiales , Prótesis e Implantes , Plata/farmacología
6.
Bone Joint Res ; 10(7): 425-436, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34269599

RESUMEN

AIMS: This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. METHODS: This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors' institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed. RESULTS: Adjacent to the nail's telescoping junction, osteolytic changes were observed in bi-planar radiographs of 20/57 segments (35%) after a mean of 9.5 months (95% confidence interval 7.2 to 11.9) after surgery. A total of 8/20 patients with osseous alterations (40%) reported rest and ambulation pain of the lengthened segment during consolidation. So far, 24 Stryde nails were retrieved and in 20 (83%) macroscopic corrosion was observed at the nail's telescoping junction. Before implant removal 11/20 radiographs (55%) of lengthened segments with these 20 nails revealed osteolysis. Implant retrieval analysis by means of SEM showed pitting and crevice corrosion. EDX detected chromium as the main metallic element of corrosion. CONCLUSION: Patients are exposed to the risk of implant-related osteolysis of unclear short- and long-term clinical consequences. The authors advocate in favour of an early implant removal after osseous consolidation. Cite this article: Bone Joint Res 2021;10(7):425-436.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA