1.
J Cardiovasc Comput Tomogr ; 16(6): 517-523, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35872138

RESUMEN

BACKGROUND: Selection of the transcatheter heart valve size for a mitral valve-in-valve procedure is based on the type and manufacturer's labelled size. However, accurate information of surgical heart valve (SHV) size may not be available in the patient's medical record. The purpose of this study is to establish reference data for computed tomography (CT) dimensions of commonly used mitral SHV in order to determine the manufacturer's labelled size from a cardiac CT data set. METHODS: CT datasets of 105 patients with surgical mitral bioprosthesis and available manufacturer labeled datasets were included in the analysis. CT derived valve dimensions were assessed by two observers using multiplanar reformats aligned with the basal sewing ring. A circular region of interest was used in a standardized fashion to minimize influence of image acquisition and reconstruction parameters. Interobserver variability was assessed by Bland-Altman analysis. RESULTS: The CT-derived dimensions were stratified by valve size and type, and SHV properties were demonstrated for 5 common valve types. Variability of measurements was small and inter-observer limits of agreement were narrow. Stratified by SHV type, no overlap was noted for CT-derived dimensions among different SHV sizes . A reference table of CT characteristics of surgical mitral bioprosthesis types was created. CONCLUSION: The study provides reference CT data for determining the manufacturers' labeled SHV size across a range of commonly used mitral SHVs. The findings will be important to help identify types of surgical mitral bioprosthesis utilizing CT characteristics for patients without SHV size documentation.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Diseño de Prótesis , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
2.
JACC Cardiovasc Interv ; 15(23): 2374-2383, 2022 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-36480984

RESUMEN

BACKGROUND: Coronary access may be challenging following transcatheter aortic valve replacement (TAVR) in the setting of transcatheter heart valve (THV) commissural misalignment. OBJECTIVES: The authors aimed to quantify the degree of commissural alignment following balloon-expandable THV implantation using a fluoroscopy-based trigonometric approach and assess its correlation with post-TAVR computed tomography (CT). METHODS: Twenty patients who had undergone both TAVR with the balloon-expandable SAPIEN 3 THV and post-TAVR CT were included in the analysis. Optimized, predeployment 3-cusp angiographic view and postdeployment angiographic view using identical fluoroscopic projections were required. The distance between the most central posterior commissural strut and the THV centerline was assessed. Commissural alignment was calculated by means of a trigonometrical approach using an arcsine function, assuming circular deployment of the THV. Commissural alignment was stratified using a 4-tier scale: aligned (0° to 15°); mildly misaligned (15° to 30°); moderately misaligned (30° to 45°), and severely misaligned (45° to 60°). RESULTS: Seven patients (35.0%) were misclassified by 1 tier, and no patient was misclassified by 2 or more tiers, with strong agreement between CT and fluoroscopy (weighted Cohen's kappa coefficient = 0.724). Correlation of the commissural offset angle determined from fluoroscopy and CT was excellent (r = 0.986; 95% CI: 0.965 to 0.995). Bland-Altman analysis demonstrated a strong agreement between both modalities with a mean difference of 0.5° (95% limits of agreement: -12.7° to 13.7°). CONCLUSIONS: The degree of commissural alignment of the balloon-expandable THV can be reliably assessed and quantified on postdeployment fluoroscopy using a standardized 3-cusp view and trigonometry-based analysis.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Válvulas Cardíacas , Tomografía Computarizada por Rayos X