Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiology ; 137(4): 207-217, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28445871

RESUMEN

OBJECTIVE: Limited data is available on the long-term outcome of patients with increased cardiovascular event risk, treated with newer-generation durable polymer drug-eluting stents (DES). METHODS: We therefore assessed 3-year follow-up data of high-risk versus low- to intermediate-risk patients of the randomized DUTCH PEERS trial (NCT01331707). In both risk groups we also compared patients treated with Resolute Integrity versus Promus Element DES. Patients were categorized as "high-risk" if they met ≥1 of the following criteria: (1) diabetes (17.9%); (2) previous myocardial infarction (21.9%); (3) previous coronary revascularization (25.8%); (4) chronic renal failure (3.5%); (5) left ventricular ejection fraction ≤30% (1.5%); and (6) age ≥75 years (17.3%). RESULTS: At the 3-year follow-up, the incidence of the composite endpoint target vessel failure (TVF) (13.2 vs. 7.5%; logrank p < 0.001) and 2 of its components - cardiac death (4.7 vs. 1.5%; logrank p < 0.001) and target vessel revascularization (7.3 vs. 4.7%; logrank p = 0.03) - was higher in high-risk (n = 957) versus low- to intermediate-risk patients (n = 854). Among high-risk patients, treatment with Resolute Integrity (n = 481) and Promus Element stents (n = 476) was similarly safe and efficacious (TVF: 13.3 vs. 13.1%; logrank p = 0.95; definite-or-probable stent thrombosis: 1.7 vs. 1.7%; logrank p = 1.00). CONCLUSIONS: The newer-generation Resolute Integrity and Promus Element stents showed similar results in terms of safety and efficacy for treating high-risk patients, who had significantly higher event rates than patients with low-to-intermediate risk.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/administración & dosificación , Trombosis/etiología , Resultado del Tratamiento
2.
Am Heart J ; 175: 121-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27179731

RESUMEN

BACKGROUND: The outcome of percutaneous coronary intervention with newer generation permanent polymer-coated drug-eluting stents (DES) in patients with severely calcified lesions is greatly unknown. We assessed the impact of severe lesion calcification on clinical outcome in patients with stable angina who underwent percutaneous coronary intervention with newer generation DES. METHODS: TWENTE and DUTCH PEERS randomized trials enrolled 1423 patients with stable angina, who were categorized into patients with versus without severe target lesion calcification. A patient-level pooled analysis assessed clinical outcome, including target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization (TVR). RESULTS: Patients with severe calcification (n = 342) were older (66.6 ± 9.1 vs 64.2 ± 9.8 years, P < .001) and had more diabetes (25.7% vs 20.4%, P = .04) than other patients (n = 1081). Patients with calcified lesions had higher rates of TVF (16.4% vs 9.8%, pLogrank = .001), cardiac death (4.4% vs 1.5%, P = .03), target vessel myocardial infarction (7.6% vs 3.4%, P = .001), and definite stent thrombosis (1.8% vs 0.4%, P = .02). Multivariate analysis demonstrated that severe calcification was an independent risk factor of 2-year TVF (HR 1.42, 95% CI: 1.02-1.99, pLogrank = .04); landmark analysis showed that this was based on a difference during the first year (periprocedural: 5.8% vs. 3.1%, pLogrank = .02; first year: 7.5% vs. 3.8%, pLogrank = .007; second year: 4.1% vs. 3.3%, pLogrank = .54). CONCLUSION: In patients with stable angina, severe target lesion calcification is associated with an increased risk of adverse cardiovascular events following treatment with newer generation permanent polymer-coated DES. This increase in risk is restricted to the first year of follow-up, which is an encouraging finding.


Asunto(s)
Angina Estable , Vasos Coronarios/patología , Intervención Coronaria Percutánea , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico , Calcificación Vascular , Anciano , Angina Estable/diagnóstico , Angina Estable/etiología , Angina Estable/terapia , Materiales Biocompatibles Revestidos/uso terapéutico , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Inmunosupresores/uso terapéutico , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Polímeros/uso terapéutico , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Calcificación Vascular/complicaciones , Calcificación Vascular/diagnóstico , Calcificación Vascular/fisiopatología
3.
Lancet ; 383(9915): 413-23, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24183564

RESUMEN

BACKGROUND: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial. METHODS: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707. FINDINGS: Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk difference 0·88%, 95% CI -1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group differences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events. INTERPRETATION: Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. FUNDING: Boston Scientific, Medtronic.


Asunto(s)
Inmunosupresores/administración & dosificación , Infarto del Miocardio/tratamiento farmacológico , Intervención Coronaria Percutánea/métodos , Sirolimus/análogos & derivados , Adulto , Anciano , Anciano de 80 o más Años , Oclusión Coronaria/tratamiento farmacológico , Muerte Súbita Cardíaca/etiología , Stents Liberadores de Fármacos , Everolimus , Femenino , Humanos , Inmunosupresores/efectos adversos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Resultado del Tratamiento , Adulto Joven
4.
Am Heart J ; 163(4): 557-62, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22520520

RESUMEN

BACKGROUND: Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed. Promus Element (Boston Scientific, Natick, MA) and Resolute Integrity (Medtronic Vascular, Santa Rosa, CA) are 2 novel third-generation DES for which limited clinical data are available. Accordingly, we designed the current multicenter study to investigate in an all-comers population whether the clinical outcome is similar after stenting with Promus Element versus Resolute Integrity. METHODS: DUTCH PEERS is a multicenter, prospective, single-blinded, randomized trial in a Dutch all-comers population. Patients with all clinical syndromes who require percutaneous coronary interventions with DES implantation are eligible. In these patients, the type of DES implanted will be randomized in a 1:1 ratio between Resolute Integrity versus Promus Element. The trial is powered based on a noninferiority hypothesis. For each stent arm, 894 patients will be enrolled, resulting in a total study population of 1,788 patients. The primary end point is the incidence of target vessel failure at 1-year follow-up. SUMMARY: DUTCH PEERS is the first randomized multicenter trial with a head-to-head comparison of Promus Element and Resolute Integrity to investigate the safety and efficacy of these third-generation DES.


Asunto(s)
Stents Liberadores de Fármacos , Angioplastia Coronaria con Balón , Everolimus , Humanos , Inmunosupresores/administración & dosificación , Países Bajos , Proyectos de Investigación , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Stents
5.
JACC Cardiovasc Interv ; 11(5): 462-469, 2018 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-29519378

RESUMEN

OBJECTIVES: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts). BACKGROUND: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices. METHODS: In total, 1,811 patients were 1:1 randomized to ZES versus EES. We performed a pre-specified assessment of the 5-year clinical outcomes in terms of safety and efficacy. The main endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Secondary endpoints included the individual components of TVF, and stent thrombosis. The study was independently monitored, and adverse clinical events were independently adjudicated. RESULTS: Five-year clinical follow-up data was available in 1,798 (99.3%) patients. The ZES and EES groups showed favorable outcomes, with similar 5-year incidence of TVF (13.2% vs. 14.2%; plog-rank = 0.62) and its individual components: cardiac death (4.5% vs. 4.9%; plog-rank = 0.69), target vessel-related myocardial infarction (3.1% vs. 2.6%; plog-rank = 0.47), and target vessel revascularization (7.6% vs. 8.6%; plog-rank = 0.46). The 5-year incidence of definite or probable stent thrombosis was similar (1.5% vs. 1.3%; plog-rank = 0.83). CONCLUSIONS: At 5-year follow-up, the Resolute Integrity ZES and PROMUS Element EES showed similar and sustained results in terms of safety and efficacy for treating a broad population of all-comers.


Asunto(s)
Síndrome Coronario Agudo/cirugía , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Países Bajos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
6.
EuroIntervention ; 13(5): e564-e571, 2017 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-27993751

RESUMEN

AIMS: Timely reperfusion with primary percutaneous coronary intervention (pPCI) in ST-segment elevation myocardial infarction (STEMI) patients is associated with superior clinical outcomes. Aiming to reduce ischaemic time, an innovative system for home-to-hospital (H2H) time monitoring was implemented, which enabled real-time evaluation of ischaemic time intervals, regular feedback and improvements in the logistic chain. The objective of this study was to assess the results after implementation of the H2H dashboard for monitoring and evaluation of ischaemic time in STEMI patients. METHODS AND RESULTS: Ischaemic time in STEMI patients transported by emergency medical services (EMS) and treated with pPCI in the Noordwest Ziekenhuis, Alkmaar before (2008-2009; n=495) and after the implementation of the H2H dashboard (2011-2014; n=441) was compared. Median time intervals were significantly shorter in the H2H group (door-to-balloon time 32 [IQR 25-43] vs. 40 [IQR 28-55] minutes, p-value <0.001, FMC-to-balloon time 62 [IQR 52-75] vs. 80 [IQR 67-103] minutes, p-value <0.001, and treatment delay 142 [IQR 103-221] vs. 159 [IQR 123-253] minutes, p-value <0.001). The H2H time dashboard was independently associated with shorter time delays. CONCLUSIONS: Real-time monitoring and feedback on time delay with the H2H dashboard improves the logistic chain in STEMI patients, resulting in shorter ischaemic time intervals.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/cirugía , Adulto , Anciano , Angioplastia Coronaria con Balón/métodos , Servicios Médicos de Urgencia/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
EuroIntervention ; 12(17): 2128-2131, 2017 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-27916746

RESUMEN

AIMS: The aim of this report was to assess the three-year safety and efficacy of implanting newer-generation Resolute Integrity zotarolimus-eluting stents (ZES) versus PROMUS Element everolimus-eluting stents (EES) in all-comers. METHODS AND RESULTS: In the randomised, multicentre, investigator-initiated DUTCH PEERS trial, a total of 1,811 all-comers were 1:1 randomly assigned to treatment with ZES versus EES. A total of 1,293 patients (72%) were treated for complex lesions and 455 patients (25%) were treated for multiple lesions. The primary endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction or target vessel revascularisation. Adverse clinical events were independently adjudicated. Three-year follow-up data were obtained in 1,807 patients (99.8%, four withdrawals). Both the ZES and EES groups showed favourable outcomes with a similar incidence of TVF (10.7% vs. 10.3%; pLog-rank=0.77) and the individual components thereof: cardiac death (3.2% vs. 3.1%; pLog-rank=0.87), target vessel-related myocardial infarction (2.8% vs. 2.2%; pLog-rank=0.44) and target vessel revascularisation (6.0% vs. 6.2%; pLog-rank=0.87). In addition, the incidence of definite or probable stent thrombosis was similar for patients treated with ZES versus EES (1.4% vs. 1.1%; pLog-rank=0.66). CONCLUSIONS: The safety and efficacy of treating all-comers with newer-generation Resolute Integrity and PROMUS Element stents was found to be extended up to three years.


Asunto(s)
Stents Liberadores de Fármacos/estadística & datos numéricos , Intervención Coronaria Percutánea/instrumentación , Estudios de Seguimiento , Humanos
8.
Clin Res Cardiol ; 105(3): 206-15, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26329584

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) in bifurcated lesions with second-generation drug-eluting stents (DES) was associated with increased myocardial infarction (MI) rates. Flexible stent designs that accommodate well to vessel tapering may be of benefit in challenging anatomies such as bifurcated target lesions, but so far data are scarce. METHODS: We analyzed the 2-year follow-up data of the DUTCH PEERS (TWENTE II) trial, which randomized 1811 all-comer patients to PCI with newer generation resolute integrity zotarolimus-eluting (Medtronic) or promus element everolimus-eluting stents (Boston Scientific). In bifurcated lesions, provisional stenting was generally performed. Target vessel failure is a composite endpoint, consisting of cardiac death, target vessel MI, or target vessel revascularization. RESULTS: Patients with at least one bifurcated lesion (n = 465, 25.7 %) versus patients with non-bifurcated target lesions only (n = 1346, 74.3 %) showed similar rates of clinical endpoints including target vessel failure (9.2 versus 7.9 %, p = 0.36) and definite stent thrombosis (0.4 versus 1.0 %, p = 0.38). Target vessel MI was more common in patients with bifurcated lesions (3.4 versus 1.6 %, p = 0.02); but after multivariate analysis with propensity score adjustment, bifurcation treatment was found not to be an independent predictor of target vessel MI (HR 1.40, 95 % CI 0.71-2.76; p = 0.34). Among patients with bifurcated lesions, DES type and side-branch size did not affect outcome, but periprocedural MI occurred more often after two-stent approaches (9.0 versus 2.1 %; p = 0.002). CONCLUSION: All-comer patients treated for bifurcated and non-bifurcated target lesions showed similar and low rates of clinical endpoints, suggesting that the DES used are efficacious and safe for treating bifurcated target lesions.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Países Bajos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
9.
JACC Cardiovasc Interv ; 8(7): 889-99, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26003019

RESUMEN

OBJECTIVES: This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts). BACKGROUND: For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce. METHODS: The DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial [TWENTE II]) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations. RESULTS: The 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel-related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 [95% confidence interval: 1.05 to 3.39], p = 0.03). CONCLUSIONS: During the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros , Sirolimus/análogos & derivados , Anciano , Angina de Pecho/etiología , Angina de Pecho/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
10.
J Mol Neurosci ; 20(1): 43-52, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12663934

RESUMEN

Neurostimulation for refractory angina pectoris is often advocated for its clinical efficacy. However, the recruited pathways to induce electroanalgesia are partially unknown. Therefore, we sought to study the effect of neurostimulation on experimentally induced cardiac nociception, using capsaicin as nociception-induced substance. Four different groups of male Wistar rats were pericardially infused with either saline or capsaicin with or without neurostimulation. Group StimCap was infused with capsaicin, and group StimVeh was infused with saline. Both groups were treated with neurostimulation. Group ShamCap was only infused with capsaicin without stimulation, whereas group ShamVeh was only infused with saline. Neuronal activation differences were assessed with cytochemical staining, revealing the cellular expression of c-fos. Pain behavior was registered on video and was quantitatively analyzed. In the StimCap and ShamCap groups, all animals exerted typical pain behavior, whereas in the StimVeh group only moderate changes in behavior were observed. Group ShamVeh animals were unaffected by the procedure. The upper thoracic spinal cord showed high numbers of c-fos-positive cells, predominantly in laminae III and IV in both StimCap and StimVeh groups. Almost no c-fos expression was noticed in groups ShamCap and ShamVeh in these sections of the spinal cord. In groups StimCap and ShamCap a significantly higher number of c-fos-positive cells in comparison with groups StimVeh and ShamVeh were noticed in the periambigus region, the nucleus tractus solitarius, and the paraventricular hypothalamus. In the paraventricular thalamus, periaqueductal gray, and central amygdala, no significant differences were noticed among the first three groups, and the c-fos concentration in these three groups was significantly higher than in group ShamVeh. It is concluded that neurostimulation does not influence capsaicin-induced cardiac nociceptive pain pulses to the central nervous system. Furthermore, capsaicin-induced cardiac pain and neurostimulation may utilize two different pathways.


Asunto(s)
Vías Aferentes/fisiología , Analgesia , Angina de Pecho/fisiopatología , Sistema Nervioso Central/fisiología , Corazón/inervación , Nociceptores/fisiología , Estimulación Eléctrica Transcutánea del Nervio , Vías Aferentes/efectos de los fármacos , Angina de Pecho/terapia , Animales , Conducta Animal/efectos de los fármacos , Conducta Animal/fisiología , Encéfalo/efectos de los fármacos , Encéfalo/fisiología , Capsaicina/farmacología , Sistema Nervioso Central/efectos de los fármacos , Inmunohistoquímica , Masculino , Neuronas/efectos de los fármacos , Neuronas/fisiología , Nociceptores/efectos de los fármacos , Proteínas Proto-Oncogénicas c-fos/metabolismo , Ratas , Ratas Wistar , Tractos Espinotalámicos/efectos de los fármacos , Tractos Espinotalámicos/fisiología , Fibras Simpáticas Posganglionares/efectos de los fármacos , Fibras Simpáticas Posganglionares/fisiología , Nervio Vago/efectos de los fármacos , Nervio Vago/fisiología
12.
Crit Pathw Cardiol ; 4(2): 88-97, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18340190

RESUMEN

The impact of patient- and operator-related clinical variables of success and evaluation of subsequent midterm effects of percutaneous treatment of left main coronary stenosis were assessed at a tertiary-referral high-volume angioplasty center in a retrospective observational study. A total of 118 consecutive surgical and nonsurgical patients with protected and unprotected left main (LM) lesions were treated by operators within a preconditioned expert culture. There were 57 protected and 61 unprotected patients, including 13 patients with an acute myocardial infarction (AMI). Mean age was 67 years (range 33-90). The length of the stenotic segment was 4.8 +/- 2.3 mm, mean lumen diameter was 1.1 +/- 0.6 mm, and percentage diameter stenosis was 63.6 +/- 14.6%. There were 7 (5.9%) in-hospital cardiac deaths that presented with AMI and cardiogenic shock. All 7 patients presented with unprotected LM lesions. Average follow-up was 8 months (range 1-36 months). Major adverse cardiac events (MACE) during follow-up comprised 8 (6.8%) cardiac deaths, 3 (2.5%) myocardial infarctions, 8 (6.8%) subjects with coronary bypass surgery, and 16 (13.6%) repeated angioplasties. The total event rate (MACE, n = 43) at the end of the follow-up period was 36.4%. There were more MACE in the unprotected group than in the protected group (41% vs. 31.6%, P<0.05). This study supports prior data on LM angioplasty. LM stenting in AMI showed less favorable in-hospital and late outcome.

13.
Catheter Cardiovasc Interv ; 60(3): 339-43, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14571484

RESUMEN

Glycoprotein IIb/IIIa receptor antagonists, such as abciximab, are used to reduce major adverse cardiac events (MACEs) in patients undergoing percutaneous transluminal coronary angioplasty. The goal of this study was to evaluate the administration of abciximab in relation to lesion complexity and periprocedural complications. A total of 357 patients with 435 de novo lesions were included in this study. Lesions were divided into simple (type A and type B1) and complex (type B2 and type C) lesions according to the American College of Cardiology/American Heart Association Task Force lesion complexity system. Abciximab was given to unstable complex lesions and simple lesions with a periprocedural unstable complicated course. The overall incidence of MACE during the 9-month follow-up period was 17.0%. Patients treated with abciximab had a higher lesion complexity (P < 0.001), dissections (P = 0.014), stents (P < 0.001), and vessels involved (P < 0.001). in addition, the abciximab group was characterized by a higher angina NYHA class (P = 0.005), lower TIMI flow prior to stenting (P = 0.01), and a longer total inflation time (P = 0.006). Despite these clinical differences, the occurrence of MACE within the abciximab group was slightly less than in the group without abciximab (16.2% and 17.3%, respectively). Lesion complexity was directly related to MACE in the group that did not receive abciximab (simple and stable complex lesions; P = 0.04). On the other hand, in subjects treated with abciximab, lesion complexity was not related to a higher incidence of MACE (P = 0.76). The use of abciximab equalizes the difference in outcome between simple and complex lesions. Therefore, abciximab should be advocated especially in unstable and complex percutaneous coronary interventions.


Asunto(s)
Angioplastia Coronaria con Balón , Anticuerpos Monoclonales/uso terapéutico , Anticoagulantes/uso terapéutico , Enfermedad Coronaria/terapia , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/uso terapéutico , Abciximab , Anciano , Implantación de Prótesis Vascular , Angiografía Coronaria , Circulación Coronaria/efectos de los fármacos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/epidemiología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/terapia , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Análisis Multivariante , Países Bajos/epidemiología , Estudios Prospectivos , Reoperación , Factores de Riesgo , Estadística como Asunto , Stents , Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA