Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 18(9)2018 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-30200371

RESUMEN

The paper presents an intelligent real-time slope surface deformation monitoring system based on binocular stereo-vision. To adapt the system to field slope monitoring, a design scheme of concentric marking point is proposed. Techniques including Zernike moment edge extraction, the least squares method, and k-means clustering are used to design a sub-pixel precision localization method for marker images. This study is mostly focused on the tracking accuracy of objects in multi-frame images obtained from a binocular camera. For this purpose, the Upsampled Cross Correlation (UCC) sub-pixel template matching technique is employed to improve the spatial-temporal contextual (STC) target-tracking algorithm. As a result, the tracking accuracy is improved to the sub-pixel level while keeping the STC tracking algorithm at high speed. The performance of the proposed vision monitoring system has been well verified through laboratory tests.

2.
Sensors (Basel) ; 17(6)2017 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-28587275

RESUMEN

Bus Rapid Transit (BRT) has become an increasing source of concern for public transportation of modern cities. Traditional contact sensing techniques during the process of health monitoring of BRT viaducts cannot overcome the deficiency that the normal free-flow of traffic would be blocked. Advances in computer vision technology provide a new line of thought for solving this problem. In this study, a high-speed target-free vision-based sensor is proposed to measure the vibration of structures without interrupting traffic. An improved keypoints matching algorithm based on consensus-based matching and tracking (CMT) object tracking algorithm is adopted and further developed together with oriented brief (ORB) keypoints detection algorithm for practicable and effective tracking of objects. Moreover, by synthesizing the existing scaling factor calculation methods, more rational approaches to reducing errors are implemented. The performance of the vision-based sensor is evaluated through a series of laboratory tests. Experimental tests with different target types, frequencies, amplitudes and motion patterns are conducted. The performance of the method is satisfactory, which indicates that the vision sensor can extract accurate structure vibration signals by tracking either artificial or natural targets. Field tests further demonstrate that the vision sensor is both practicable and reliable.

3.
Surg Oncol ; 28: 78-85, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30851917

RESUMEN

OBJECTIVES: To develop and validate a radiomics-based nomogram for the preoperative prediction of posthepatectomy liver failure (PHLF) in patients with hepatocellular carcinoma (HCC). METHODS: One hundred twelve consecutive HCC patients who underwent hepatectomy were included in the study pool (training cohort: n = 80, validation cohort: n = 32), and another 13 patients were included in a pilot prospective analysis. A total of 713 radiomics features were extracted from portal-phase computed tomography (CT) images. A logistic regression was used to construct a radiomics score (Rad-score). Then a nomogram, including Rad-score and other risk factors, was built with a multivariate logistic regression model. The discrimination, calibration and clinical utility of nomogram were evaluated. RESULTS: The Rad-score could predict PHLF with an AUC of 0.822 (95% CI, 0.726-0.917) in the training cohort and of 0.762 (95% CI, 0.576-0.948) in the validation cohort; however, the approach could not completely outmatch the existing methods (CP [Child-Pugh], MELD [Model of End Stage Liver Disease], ALBI [albumin-bilirubin]). The individual predictive nomogram that included the Rad-score, MELD and performance status (PS) showed better discrimination with an AUC of 0.864 (95% CI, 0.786-0.942), which was higher than the AUCs of the conventional methods (nomogram vs CP, MELD, and ALBI at P < 0.001, P < 0.005, and P < 0.005, respectively). In the validation cohort, the nomogram discrimination was also superior to those of the other three methods (AUC: 0.896; 95% CI, 0.774-1.000). The calibration curves showed good agreement in both cohorts, and the decision curve analysis of the entire cohort revealed that the nomogram was clinically useful. A pilot prospective analysis showed that the radiomics nomogram could predict PHLF with an AUC of 0.833 (95% CI, 0.591-1.000). CONCLUSIONS: A nomogram based on the Rad-score, MELD, and PS can predict PHLF.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Hepatectomía/efectos adversos , Fallo Hepático/diagnóstico , Neoplasias Hepáticas/cirugía , Nomogramas , Tomografía Computarizada por Rayos X/métodos , Carcinoma Hepatocelular/patología , Femenino , Estudios de Seguimiento , Humanos , Fallo Hepático/diagnóstico por imagen , Fallo Hepático/etiología , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA