RESUMEN
BACKGROUND: Cryoballoon ablation (CBA) as a first-line rhythm control strategy is superior to antiarrhythmic drugs (AADs) for preventing atrial fibrillation (AF) recurrence; the impact of first-line CBA on quality of life (QoL) and symptoms has not been well characterized. METHODS: Patients aged 18 to 75 with symptomatic paroxysmal AF naïve to rhythm control therapy were randomized (1:1) to CBA (Arctic Front Advance, Medtronic) or AAD (Class I or III). Symptoms and QoL were assessed at baseline, 1, 3, 6, 9, and 12 months using the EHRA classification and Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and SF-36v2 questionnaires. Symptomatic palpitations were evaluated via patient diary. RESULTS: Overall, 107 patients were randomized to CBA and 111 to AAD; crossovers occurred in 9%. Larger improvements in the AFEQT summary, subscale and treatment satisfaction scores were observed at 12 months with CBA vs AAD (all P <0.05). At 12 months, the mean adjusted difference in the AFEQT summary score was 9.9 points higher in the CBA group (95% CI: 5.5 -14.2, P <0.001). Clinically important improvements in the SF-36 physical and mental component scores were observed at 12 months in both groups, with no significant between group differences at this timepoint. In the CBA vs AAD group, larger improvements in EHRA class were observed at 6, 9 and 12 months (P <0.05) and the incidence rate of symptomatic palpitations was lower (4.6 vs 15.2 days/year post-blanking; IRR: 0.30, P <0.001). CONCLUSIONS: In patients with symptomatic AF, first-line CBA was superior to AAD for improving AF-specific QoL and symptoms. TRIAL REGISTRATION: ClinicalTrials.gov number: NCT01803438.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Adolescente , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Humanos , Persona de Mediana Edad , Calidad de Vida , Resultado del Tratamiento , Adulto JovenRESUMEN
AIMS: Treatment guidelines for patients with atrial fibrillation (AF) suggest that patients should be managed with an antiarrhythmic drug (AAD) before undergoing catheter ablation (CA). This study evaluated whether pulmonary vein isolation employing cryoballoon CA is superior to AAD therapy for the prevention of atrial arrhythmia (AA) recurrence in rhythm control naive patients with paroxysmal AF (PAF). METHODS AND RESULTS: A total of 218 treatment naive patients with symptomatic PAF were randomized (1 : 1) to cryoballoon CA (Arctic Front Advance, Medtronic) or AAD (Class I or III) and followed for 12 months. The primary endpoint was ≥1 episode of recurrent AA (AF, atrial flutter, or atrial tachycardia) >30 s after a prespecified 90-day blanking period. Secondary endpoints included the rate of serious adverse events (SAEs) and recurrence of symptomatic palpitations (evaluated via patient diaries). Freedom from AA was achieved in 82.2% of subjects in the cryoballoon arm and 67.6% of subjects in the AAD arm (HR = 0.48, P = 0.01). There were no group differences in the time-to-first (HR = 0.76, P = 0.28) or overall incidence [incidence rate ratio (IRR)=0.79, P = 0.28] of SAEs. The incidence rate of symptomatic palpitations was lower in the cryoballoon (7.61 days/year) compared with the AAD arm (18.96 days/year; IRR = 0.40, P < 0.001). CONCLUSIONS: Cryoballoon CA was superior to AAD therapy, significantly reducing AA recurrence in treatment naive patients with PAF. Additionally, cryoballoon CA was associated with lower symptom recurrence and a similar rate of SAEs compared with AAD therapy.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Radiofrequency current (RFC) catheter ablation for patients with paroxysmal atrial fibrillation (AF) has been shown to be safe and effective in first-line therapy. Recent data demonstrates that RFC ablation provides better clinical outcomes compared to antiarrhythmic drug (AAD) in the treatment of early AF disease. Furthermore, studies comparing RFC and cryoballoon have established comparable efficacy and safety of pulmonary vein isolation (PVI) for patients with symptomatic paroxysmal AF. OBJECTIVES: The Cryo-FIRST trial was designed to compare AAD treatment against cryoballoon PVI as a first-line therapy in treatment naïve patients with AF. Efficacy and safety will be compared between the two cohorts and amongst subgroups. METHODS: The primary hypothesis is that cryoablation is superior to AAD therapy. To test this hypothesis, patients will be randomized in a 1:1 design. Using a 90-day blanking period, primary efficacy endpoint failure is defined as (at least) one episode of atrial arrhythmia with a duration >30 sec (documented by 7-day Holter or 12-lead ECG). Secondary endpoints (Quality-of-Life, rehospitalization, arrhythmia recurrence rate, healthcare utilization, and left atrial function) and adverse events will also be evaluated. Study enrollment will include 218 patients in up to 16 centers. CONCLUSIONS: This study will be a multi-national randomized controlled trial comparing cryoablation against AAD as a first-line treatment in patients with paroxysmal AF. The results may help guide the selection of patients for early AF disease therapy via cryoballoon ablation.
Asunto(s)
Técnicas de Ablación/métodos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Criocirugía/métodos , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Fibrilación Atrial/fisiopatología , Función del Atrio Derecho/fisiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Método Simple Ciego , Resultado del TratamientoRESUMEN
The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.