Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Sleep Med ; 13(10): 1213-1217, 2017 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-28859719

RESUMEN

ABSTRACT: Sleep-related rhythmic movements (SRRMs) are typical in infancy and childhood, where they usually occur at the wake-to-sleep transition. However, they have rarely been observed in adults, where they can be idiopathic or associated with other sleep disorders including sleep apnea. We report a case series of 5 adults with sleep-related rhythmic movement disorder, 4 of whom had a previous history of SRRMs in childhood. SRRMs mostly occurred in consolidated sleep, in association with pathological respiratory events, predominantly longer ones, especially during stage R sleep, and recovered in 1 patient with continuous positive airway pressure therapy. We hypothesize that sleep apneas may act as a trigger of rhythmic motor events through a respiratory-related arousal mechanism in genetically predisposed subjects.


Asunto(s)
Parasomnias/complicaciones , Apnea Obstructiva del Sueño/complicaciones , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía
2.
Sleep ; 29(4): 470-7, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16676780

RESUMEN

STUDY OBJECTIVES: The objective was to evaluate the responsiveness of upper airway muscles to hypercapnia with and without intrapharyngeal negative pressure during non-rapid eye movement (NREM) sleep and wakefulness. DESIGN: We assessed the genioglossal muscle response to CO2 off and on continuous positive airway pressure (CPAP) (to attenuate negative pressure) during stable NREM sleep and wakefulness in the supine position. SETTING: Laboratory of the Sleep Medicine Division, Brigham and Women's Hospital. PATIENTS OR PARTICIPANTS: Eleven normal healthy subjects. INTERVENTIONS: During wakefulness and NREM sleep, we measured genioglossal electromyography (EMG) on and off CPAP at the normal eupneic level and at levels 5 and 10 mm Hg above the awake eupneic level. MEASUREMENTS AND RESULTS: We observed that CO2 could increase upper-airway muscle activity during NREM sleep and wakefulness in the supine position with and without intrapharyngeal negative pressure. The application of nasal CPAP significantly decreased genioglossal EMG at all 3 levels of PETCO2 during NREM sleep (13.0 +/- 4.9% vs. 4.6 +/- 1.6% of maximal EMG, 14.6 +/- 5.6% vs. 7.1 +/- 2.3% of maximal EMG, and 17.3 +/- 6.3% vs. 10.2 +/- 3.1% of maximal EMG, respectively). However, the absence of negative pressure in the upper airway did not significantly affect the slope of the pharyngeal airway dilator muscle response to hypercapnia during NREM sleep (0.72 +/- 0.30% vs. 0.79 +/- 0.27% of maximal EMG per mm Hg PCO2, respectively, off and on CPAP). CONCLUSIONS: We conclude that both chemoreceptive and negative pressure reflex inputs to this upper airway dilator muscle are still active during stable NREM sleep.


Asunto(s)
Dióxido de Carbono/farmacología , Músculos Faciales/efectos de los fármacos , Hipercapnia/diagnóstico , Músculos Faríngeos/efectos de los fármacos , Fases del Sueño/efectos de los fármacos , Adulto , Dióxido de Carbono/administración & dosificación , Presión de las Vías Aéreas Positiva Contínua/métodos , Electromiografía , Femenino , Humanos , Hipercapnia/terapia , Masculino , Vigilia/fisiología
3.
Sleep Med ; 13(4): 425-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22261242

RESUMEN

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.


Asunto(s)
Cooperación del Paciente , Postura , Apnea Obstructiva del Sueño/terapia , Actigrafía , Adulto , Anciano , Equipos y Suministros , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Posición Prona , Fases del Sueño , Posición Supina , Resultado del Tratamiento
4.
Thorax ; 62(10): 861-7, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17412778

RESUMEN

BACKGROUND: Most patients with obstructive sleep apnoea (OSA) can restore airflow after an obstructive respiratory event without arousal at least some of the time. The mechanisms that enable this ventilatory recovery are unclear but probably include increased upper airway dilator muscle activity and/or changes in respiratory timing. The aims of this study were to compare the ability to recover ventilation and the mechanisms of compensation following a sudden reduction of continuous positive airway pressure (CPAP) in subjects with and without OSA. METHODS: Ten obese patients with OSA (mean (SD) apnoea-hypopnoea index 62.6 (12.4) events/h) and 15 healthy non-obese non-snorers were instrumented with intramuscular genioglossus electrodes and a mask/pneumotachograph which was connected to a modified CPAP device that could deliver either continuous positive or negative pressure. During stable non-rapid eye movement sleep the CPAP was repeatedly reduced 2-10 cm H2O below the level required to eliminate flow limitation and was held at this level for 5 min or until arousal from sleep occurred. RESULTS: During reduced CPAP the increases in genioglossus activity (311.5 (49.4)% of baseline in subjects with OSA and 315.4 (76.2)% of baseline in non-snorers, p = 0.9) and duty cycle (123.8 (3.9)% of baseline in subjects with OSA and 118.2 (2.8)% of baseline in non-snorers, p = 0.4) were similar in both groups, yet patients with OSA could restore ventilation without cortical arousal less often than non-snorers (54.1% vs 65.7% of pressure drops, p = 0.04). When ventilatory recovery did not occur, genioglossus muscle and respiratory timing changes still occurred but these did not yield adequate pharyngeal patency/ventilation. CONCLUSIONS: Compensatory mechanisms (increased genioglossus muscle activity and/or duty cycle) often restore ventilation during sleep but may be less effective in obese patients with OSA than in non-snorers.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Obesidad/fisiopatología , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Anciano , Humanos , Persona de Mediana Edad , Músculos Respiratorios/fisiología , Fenómenos Fisiológicos Respiratorios , Apnea Obstructiva del Sueño/terapia
6.
Am J Respir Crit Care Med ; 172(1): 114-7, 2005 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15817803

RESUMEN

Previous studies have demonstrated that lung volume during wakefulness influences upper airway size and resistance, particularly in patients with sleep apnea. We sought to determine the influence of lung volume on the level of continuous positive airway pressure (CPAP) required to prevent flow limitation during non-REM sleep in subjects with sleep apnea. Seventeen subjects (apnea-hypopnea index, 42.6 +/- 6.2 [SEM]) were studied during stable non-REM sleep in a rigid head-out shell equipped with a positive/negative pressure attachment for manipulation of extrathoracic pressure. An epiglottic pressure catheter plus a mask/pneumotachometer were used to assess flow limitation. When lung volume was increased by 1,035 +/- 22 ml, the CPAP level could be decreased from 11.9 +/- 0.7 to 4.8 +/- 0.7 cm H(2)O (p < 0.001) without flow limitation. The decreased CPAP at the same negative extrathoracic pressure yielded a final lung volume increase of 421 +/- 36 ml above the initial value. Conversely, when lung volume was reduced by 732 +/- 74 ml (n = 8), the CPAP level had to be increased from 11.9 +/- 0.7 to 17.1 +/- 1.0 cm H(2)O (p < 0.001) to prevent flow limitation, with a final lung volume decrease of 567 +/- 78 ml. These results demonstrate that relatively small changes in lung volume have an important effect on the upper airway in subjects with sleep apnea during non-REM sleep.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/métodos , Mediciones del Volumen Pulmonar , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/terapia , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Fases del Sueño
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA