Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
J Arthroplasty ; 38(6S): S145-S150, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36791890

RESUMEN

BACKGROUND: Cementless fixation in total knee arthroplasty (TKA) is re-emerging due to improvements in biomaterials, surgical technique, and implant design. Albeit rare, failure of osseointegration typically occurs within the first 2 years, and limited data exist on survivorship of the modern cementless TKA designs. This study evaluated clinical survivorship of 2 contemporary cementless TKA designs at minimum 2-year follow-up. METHODS: A total of 627 cementless TKAs were performed up to July 2022. Three hundred thirty-nine cases were eligible for 2-year follow-up. Indications centered around bone quality and involved predominantly younger patients. The 2 designs consisted of tibial components with a highly porous titanium ingrowth surface, a central keel, and peripheral cruciform pegs with a porous cobalt-chromium femur. Survivorship estimates were calculated using right-censored non-parametric Kaplan-Meier methodologies. A total of 226 TKAs obtained minimum 2-year follow-up with a mean of 3.6 years (range, 2 to 10). RESULTS: The all-cause revision rate was 2.4% (8 of 339). The revision rate due to aseptic loosening was 0.6% (2 of 339) consisting of 2 femoral components. No tibial components were revised for aseptic loosening. Kaplan-Meier survivorship free from aseptic loosening was 99% (95% confidence interval 98 to 100) at a maximum of 10 years. CONCLUSION: These results demonstrate encouraging survivorship of cementless fixation in primary TKA with use of contemporary ingrowth biomaterials and modern implant designs. This particular tibial implant design with a highly porous titanium fixation surface, central keel, and peripheral cruciform pegs demonstrated excellent clinical survivorship without failure which may portend superior fixation. LEVEL OF EVIDENCE: IV-case series, no control group/historical control group.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Titanio , Fémur/cirugía , Materiales Biocompatibles , Reoperación , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Estudios de Seguimiento
2.
Ann Surg ; 261(5): 920-5, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25844969

RESUMEN

OBJECTIVE: We sought to determine the reliability of surgeon-specific postoperative complication rates after colectomy. BACKGROUND: Conventional measures of surgeon-specific performance fail to acknowledge variation attributed to statistical noise, risking unreliable assessment of quality. METHODS: We examined all patients who underwent segmental colectomy with anastomosis from 2008 through 2010 participating in the Michigan Surgical Quality Collaborative Colectomy Project. Surgeon-specific complication rates were risk-adjusted according to patient characteristics with multiple logistic regression. Hierarchical modeling techniques were used to determine the reliability of surgeon-specific risk-adjusted complication rates. We then adjusted these rates for reliability. To evaluate the extent to which surgeon-level variation was reduced, surgeons were placed into quartiles based on performance and complication rates were compared before and after reliability adjustment. RESULTS: A total of 5033 patients (n = 345 surgeons) undergoing partial colectomy reported a risk-adjusted complication rate of 24.5%. Approximately 86% of the variability of complication rates across surgeons was explained by measurement noise, whereas the remaining 14% represented true signal. Risk-adjusted complication rates varied from 0% to 55.1% across quartiles before adjusting for reliability. Reliability adjustment greatly diminished this variation, generating a 1.2-fold difference (21.4%-25.6%). A caseload of 168 colectomies across 3 years was required to achieve a reliability of more than 0.7, which is considered a proficient level. Only 1 surgeon surpassed this volume threshold. CONCLUSIONS: The vast majority of surgeons do not perform enough colectomies to generate a reliable surgeon-specific complication rate. Risk-adjusted complication rates should be viewed with caution when evaluating surgeons with low operative volume, as statistical noise is a large determinant in estimating their surgeon-specific complication rates.


Asunto(s)
Colectomía/estadística & datos numéricos , Revelación , Complicaciones Posoperatorias/epidemiología , Cirujanos , Anciano , Anciano de 80 o más Años , Competencia Clínica , Femenino , Humanos , Masculino , Michigan/epidemiología , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Reproducibilidad de los Resultados , Cirujanos/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA