Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(22)2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36433593

RESUMEN

Objective: Quality of intraoperative teamwork may have a direct impact on patient outcomes. Heart rate variability (HRV) synchrony may be useful for objective assessment of team cohesion and good teamwork. The primary aim of this study was to investigate the feasibility of using HRV synchrony in surgical teams. Secondary aims were to investigate the association of HRV synchrony with length of procedure (LOP), complications, number of intraoperative glitches and length of stay (LOS). We also investigated the correlation between HRV synchrony and team familiarity, pre- and intraoperative stress levels (STAI questionnaire), NOTECHS score and experience of team members. Methods: Ear, nose and throat (ENT) and vascular surgeons (consultant and registrar team members) were recruited into the study. Baseline demographics including level of team members' experience were gathered before each procedure. For each procedure, continuous electrocardiogram (ECG) recording was performed and questionnaires regarding pre- and intraoperative stress levels and non-technical skills (NOTECHS) scores were collected for each team member. An independent observer documented the time of each intraoperative glitch. Statistical analysis was conducted using stepwise multiple linear regression. Results: Four HRV synchrony metrics which may be markers of efficient surgical collaboration were identified from the data: 1. number of HRV synchronies per hour of procedure, 2. number of HRV synchrony trends per hour of procedure, 3. length of HRV synchrony trends per hour of procedure, 4. area under the HRV synchrony trend curve per hour of procedure. LOP was inversely correlated with number of HRV synchrony trends per hour of procedure (p < 0.0001), area under HRV synchrony trend curve per hour of procedure (p = 0.001), length of HRV synchrony trends per hour of procedure (p = 0.002) and number of HRV synchronies per hour of procedure (p < 0.0001). LOP was positively correlated with: FS (p = 0.043; R = 0.358) and intraoperative STAI score of the whole team (p = 0.007; R = 0.493). Conclusions: HRV synchrony metrics within operating teams may be used as an objective marker to quantify surgical teamwork. We have shown that LOP is shorter when the intraoperative surgical teams' HRV is more synchronised.


Asunto(s)
Frecuencia Cardíaca , Humanos , Proyectos Piloto
2.
Clin Linguist Phon ; 35(9): 809-828, 2021 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-33146053

RESUMEN

Interactive speech audiometry is the assessment of speech comprehension and phonological discrimination through automated means. In order for the performance of such assessments in preschoolers to be successful, the employed list of words and pictures must be easily recognized both linguistically and visually. That is, the children must be able to easily associate the sound they hear with the picture they see with a high degree of certainty. To this end, a Thai monosyllabic word and picture list called NCU-20 (NECTEC-CU-20) is proposed. The word lists for Thai vowel and consonant hearing tests are designed with an awareness of phonetic environments. Regarding Thai vowels, both monophthongs and diphthongs, with all qualities and quantities, are examined. Initial consonants are categorized based on places and manners of articulation. The effectiveness of the list is objectively and subjectively verified through Thai Textbook Corpus, Thai National Corpus, Zipf scores, a listening test of preschoolers with normal hearing, and our proposed ranking systems referred to as Tier-1st, Tier-3/3, and Overall Tier. The final suggested word and picture list comprises 45 items (words) covering 35 vowels and consonant groups in the Thai Language.


Asunto(s)
Lenguaje , Percepción del Habla , Audiometría del Habla , Niño , Humanos , Fonética , Habla , Tailandia
3.
PLoS One ; 18(9): e0291070, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37656750

RESUMEN

Mental health, especially stress, plays a crucial role in the quality of life. During different phases (luteal and follicular phases) of the menstrual cycle, women may exhibit different responses to stress from men. This, therefore, may have an impact on the stress detection and classification accuracy of machine learning models if genders are not taken into account. However, this has never been investigated before. In addition, only a handful of stress detection devices are scientifically validated. To this end, this work proposes stress detection and multilevel stress classification models for unspecified and specified genders through ECG and EEG signals. Models for stress detection are achieved through developing and evaluating multiple individual classifiers. On the other hand, the stacking technique is employed to obtain models for multilevel stress classification. ECG and EEG features extracted from 40 subjects (21 females and 19 males) were used to train and validate the models. In the low&high combined stress conditions, RBF-SVM and kNN yielded the highest average classification accuracy for females (79.81%) and males (73.77%), respectively. Combining ECG and EEG, the average classification accuracy increased to at least 87.58% (male, high stress) and up to 92.70% (female, high stress). For multilevel stress classification from ECG and EEG, the accuracy for females was 62.60% and for males was 71.57%. This study shows that the difference in genders influences the classification performance for both the detection and multilevel classification of stress. The developed models can be used for both personal (through ECG) and clinical (through ECG and EEG) stress monitoring, with and without taking genders into account.


Asunto(s)
Aprendizaje Automático , Calidad de Vida , Humanos , Femenino , Masculino , Cuerpo Lúteo , Electrocardiografía , Electroencefalografía
4.
Comput Intell Neurosci ; 2019: 5618303, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31015827

RESUMEN

Neuronal activity is composed of synchronous and asynchronous oscillatory activity at different frequencies. The neuronal oscillations occur at time scales well matched to the temporal resolution of electroencephalography (EEG); however, to derive meaning from the electrical brain activity as measured from the scalp, it is useful to decompose the EEG signal in space and time. In this study, we elaborate on the investigations into source-based signal decomposition of EEG. Using source localization, the electrical brain signal is spatially unmixed and the neuronal dynamics from a region of interest are analyzed using empirical mode decomposition (EMD), a technique aimed at detecting periodic signals. We demonstrate, first in simulations, that the EMD is more accurate when applied to the spatially unmixed signal compared to the scalp-level signal. Furthermore, on EEG data recorded simultaneously with transcranial magnetic stimulation (TMS) over the hand area of the primary motor cortex, we observe a link between the peak to peak amplitude of the motor-evoked potential (MEP) and the phase of the decomposed localized electrical activity before TMS onset. The results thus encourage combination of source localization and EMD in the pursuit of further insight into the mechanisms of the brain with respect to the phase and frequency of the electrical oscillations and their cortical origin.


Asunto(s)
Encéfalo/fisiología , Electroencefalografía , Potenciales Evocados Motores/fisiología , Neuronas/fisiología , Electroencefalografía/métodos , Mano/fisiología , Humanos , Estimulación Magnética Transcraneal/métodos
5.
Med Image Anal ; 47: 1-14, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29653251

RESUMEN

Radiofrequency catheter ablation is one of the commonly available therapeutic methods for patients suffering from cardiac arrhythmias. The prerequisite of successful ablation is sufficient energy delivery at the target site. However, cardiac and respiratory motion, coupled with endocardial irregularities, can cause catheter drift and dispersion of the radiofrequency energy, thus prolonging procedure time, damaging adjacent tissue, and leading to electrical reconnection of temporarily ablated regions. Therefore, positional accuracy and stability of the catheter tip during energy delivery is of great importance for the outcome of the procedure. This paper presents an analytical scheme for assessing catheter tip stability, whereby a sequence of catheter tip motion recorded at sparse locations on the endocardium is decomposed. The spatial sliding component along the endocardial wall is extracted from the recording and maximal slippage and its associated probability are computed at each mapping point. Finally, a global map is generated, allowing the assessment of potential areas that are compromised by tip slippage. The proposed framework was applied to 40 retrospective studies of congenital heart disease patients and further validated on phantom data and simulations. The results show a good correlation with other intraoperative factors, such as catheter tip contact force amplitude and orientation, and with clinically documented anatomical areas of high catheter tip instability.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/cirugía , Ablación por Catéter/instrumentación , Tomografía Computarizada de Haz Cónico , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Intervencional/métodos , Algoritmos , Humanos , Movimiento (Física) , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Procesamiento de Señales Asistido por Computador
6.
R Soc Open Sci ; 4(12): 170853, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29308229

RESUMEN

A highly localized data-association measure, termed intrinsic synchrosqueezing transform (ISC), is proposed for the analysis of coupled nonlinear and non-stationary multivariate signals. This is achieved based on a combination of noise-assisted multivariate empirical mode decomposition and short-time Fourier transform-based univariate and multivariate synchrosqueezing transforms. It is shown that the ISC outperforms six other combinations of algorithms in estimating degrees of synchrony in synthetic linear and nonlinear bivariate signals. Its advantage is further illustrated in the precise identification of the synchronized respiratory and heart rate variability frequencies among a subset of bass singers of a professional choir, where it distinctly exhibits better performance than the continuous wavelet transform-based ISC. We also introduce an extension to the intrinsic phase synchrony (IPS) measure, referred to as nested intrinsic phase synchrony (N-IPS), for the empirical quantification of physically meaningful and straightforward-to-interpret trends in phase synchrony. The N-IPS is employed to reveal physically meaningful variations in the levels of cooperation in choir singing and performing a surgical procedure. Both the proposed techniques successfully reveal degrees of synchronization of the physiological signals in two different aspects: (i) precise localization of synchrony in time and frequency (ISC), and (ii) large-scale analysis for the empirical quantification of physically meaningful trends in synchrony (N-IPS).

7.
Philos Trans A Math Phys Eng Sci ; 374(2065): 20150199, 2016 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-26953174

RESUMEN

An extension to multivariate empirical mode decomposition (MEMD), termed adaptive-projection intrinsically transformed MEMD (APIT-MEMD), is proposed to cater for power imbalances and inter-channel correlations in real-world multichannel data. It is shown that the APIT-MEMD exhibits similar or better performance than MEMD for a large number of projection vectors, whereas it outperforms MEMD for the critical case of a small number of projection vectors within the sifting algorithm. We also employ the noise-assisted APIT-MEMD within our proposed intrinsic multiscale analysis framework and illustrate the advantages of such an approach in notoriously noise-dominated cooperative brain-computer interface (BCI) based on the steady-state visual evoked potentials and the P300 responses. Finally, we show that for a joint cognitive BCI task, the proposed intrinsic multiscale analysis framework improves system performance in terms of the information transfer rate.


Asunto(s)
Interfaces Cerebro-Computador , Procesamiento de Señales Asistido por Computador , Algoritmos , Ingeniería Biomédica , Electroencefalografía , Humanos
8.
Proc Math Phys Eng Sci ; 471(2173): 20140709, 2015 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-25568621

RESUMEN

A novel multi-scale approach for quantifying both inter- and intra-component dependence of a complex system is introduced. This is achieved using empirical mode decomposition (EMD), which, unlike conventional scale-estimation methods, obtains a set of scales reflecting the underlying oscillations at the intrinsic scale level. This enables the data-driven operation of several standard data-association measures (intrinsic correlation, intrinsic sample entropy (SE), intrinsic phase synchrony) and, at the same time, preserves the physical meaning of the analysis. The utility of multi-variate extensions of EMD is highlighted, both in terms of robust scale alignment between system components, a pre-requisite for inter-component measures, and in the estimation of feature relevance. We also illuminate that the properties of EMD scales can be used to decouple amplitude and phase information, a necessary step in order to accurately quantify signal dynamics through correlation and SE analysis which are otherwise not possible. Finally, the proposed multi-scale framework is applied to detect directionality, and higher order features such as coupling and regularity, in both synthetic and biological systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA