Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Emerg Med ; 38(1): 122-126, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31349906

RESUMEN

OBJECTIVE: The purpose of this pilot study was to investigate whether use of a guidewire improves successful placement of ultrasound-guided peripheral IVs (PIV) in difficult intravenous access patients in the emergency department (ED). METHODS: This was an unblinded, prospective, randomized trial performed by emergency medicine (EM) clinicians at a single academic ED. Eligible participants were randomized to ultrasound-guided PIV placement with or without the use of a guidewire. PIV access was obtained using the Accucath™ 20 gauge × 5.7 cm catheters by way of deployment or non-deployment of the guidewire. Primary outcome measure was first-pass success rate and secondary outcomes included number of attempts, complication rates, and clinician reported ease of insertion. RESULTS: Seventy patients were enrolled and 69 were included in the final analysis. Thirty-four participants were randomized to use of guidewire and 35 to no guidewire. First-pass success rates were similar with and without guidewire use, 47.1% vs. 45.7%, (p = 0.9). There were no differences found in median number of attempts between the two techniques, 2 (IQR 1-2) vs 2 (IQR 1-2), (p = 0.60). The complication rates were similar, 15% vs. 29% (p = 0.25). Clinicians reported no difference in ease of insertion between methods on a 5-point Likert Scale, mean 2.6 vs 2.7 (p = 0.76). DISCUSSION: In this pilot study comparing ultrasound-guided PIV placement in ED patients using an integrated guidewire versus no guidewire, there was no significant difference in first-pass success, number of attempts, or complication rates. This study provides preliminary data for further investigations.


Asunto(s)
Cateterismo Periférico/métodos , Servicio de Urgencia en Hospital , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Factores de Tiempo , Ultrasonografía
2.
J Ultrasound Med ; 39(3): 499-506, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31490569

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the accuracy and timeliness of resident-performed point-of-care lung ultrasound (LUS) examinations for the follow-up of pneumothorax (PTX) after tube thoracostomy. METHODS: After brief training, Rwandan surgical residents blinded to chest radiography (CXR) performed and interpreted LUS examinations for PTX in participants undergoing CXR for PTX follow-up. Treating clinicians interpreted CXR for the presence of PTX for therapeutic decisions. Lung ultrasound was later reviewed by ultrasound experts, and CXR was reviewed by a radiologist. We defined expert LUS interpretation as the reference standard. The sensitivity and specificity of resident-performed LUS examinations for diagnosing PTX were calculated. We assessed agreement between trained resident versus expert LUS and clinician versus radiology CXR using the Cohen κ coefficient. We compared the time to results between LUS and CXR. RESULTS: Over an 8-month period, 51 participants were enrolled. Compared to expert LUS interpretation, the sensitivity and specificity (95% confidence intervals) of resident LUS were 100% (85%-100%) and 96% (82%-100%), respectively, whereas the sensitivity and specificity of clinician-interpreted CXR were 48% (27%-69%) and 100% (88%-100%). The agreement between resident and expert LUS was excellent (κ = 0.96), whereas the agreement between clinician and radiologist CXR was only moderate (κ = 0.60). The time to results was significantly longer for CXR than LUS (mean, 1335 versus 396 minutes; P = .0001). CONCLUSIONS: A resident-performed LUS examination was a quicker imaging modality with superior sensitivity compared to clinician-interpreted CXR for PTX follow-up after tube thoracostomy in this Rwandan study. Lung ultrasound can be a valuable imaging tool for PTX follow-up, especially in resource-limited settings.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Internado y Residencia/estadística & datos numéricos , Neumotórax/diagnóstico por imagen , Sistemas de Atención de Punto , Radiografía Torácica/métodos , Toracostomía/efectos adversos , Ultrasonografía/métodos , Adolescente , Adulto , Niño , Femenino , Estudios de Seguimiento , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Rwanda , Sensibilidad y Especificidad , Ultrasonografía/instrumentación , Adulto Joven
3.
J Ultrasound Med ; 38(2): 371-377, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30043460

RESUMEN

OBJECTIVES: Ultrasound (US) is increasingly used in settings where commercial US gel is unavailable. This study evaluated noncommercial gel recipes compared to commercial gel. METHODS: A search for US gel formulations revealed 6 recipes. Half-strength commercial gel and a modified glucomannan recipe were also tested. Nine gels, including commercial gel, were tested in Liberia and the United States. In each session, 2 physician sonologists evaluated 9 gels on 2 models, obtaining videos from the hepatorenal space with a curvilinear transducer, the cardiac parasternal long view with a phased array transducer, and the left basilic vein with a linear transducer. The sonologists and models, who were blinded to gel identity, made independent quantitative and qualitative gel evaluations comparing the test gel to commercial gel. Two physician sonologists who were blinded to the gel identities and a US operator reviewed the images and rated their quality. An analysis of variance in repeated measures was performed to test for differences in the overall score, real-time quality, and other characteristics. Post hoc pairwise comparisons to commercial gel were performed with a Tukey-Kramer adjustment. Inter- and intra-rater reliability was calculated for the image review. RESULTS: Commercial gel earned a perfect score. Compared to commercial gel, xanthine gum gel scored highest, followed by half-strength commercial gel. Hot concentrated glucomannan and cold glucomannan gel were found to be significantly worse than commercial gel. No significant difference was found between images based on the gel used on the image review. CONCLUSIONS: No significant difference in image quality was found between commercial and noncommercial gels on US image review.


Asunto(s)
Geles/química , Geles/normas , Ultrasonografía/instrumentación , Brazo/irrigación sanguínea , Brazo/diagnóstico por imagen , Países en Desarrollo , Recursos en Salud , Corazón/diagnóstico por imagen , Humanos , Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Liberia , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Reproducibilidad de los Resultados , Transductores , Ultrasonografía/métodos , Estados Unidos
4.
Curr Cardiol Rep ; 21(10): 120, 2019 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-31473827

RESUMEN

PURPOSE OF REVIEW: Acute heart failure (AHF) is a common emergency presentation in Sub-Saharan Africa (SSA). In the current review, we present the most recent data on the epidemiology of AHF in SSA and discuss recommended approaches to management in resource-limited settings, with a particular focus on primary and secondary facilities (e.g., health centers and district hospitals), where these patients often present. RECENT FINDINGS: AHF in SSA is most often due to hypertension, cardiomyopathies, and rheumatic heart disease. The etiology of AHF may be different in rural as compared with urban settings. Diagnostic tools for AHF are often lacking in SSA, especially at the first-level facilities. Point-of-care ultrasound (POCUS) and biomarker tests, such as brain natriuretic peptide (BNP), offer promise in helping to mitigate diagnostic challenges. POCUS can also help distinguish among types of heart failure and prompt the correct treatment strategy. Many of the drugs and equipment commonly used to treat AHF in resource-rich settings are lacking in SSA. However, some adaptations of commonly available materials may provide temporary alternatives. The epidemiology of AHF in SSA differs from that of high-income settings. Management of AHF at the first-level facility in SSA is an important and understudied problem. Simplified diagnostic and treatment algorithms rooted in knowledge of the local epidemiology should be developed and tested as part of broader efforts to combat cardiovascular disease in SSA.


Asunto(s)
Cardiomiopatías/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hipertensión/complicaciones , Cardiopatía Reumática/complicaciones , Enfermedad Aguda , África del Sur del Sahara , Insuficiencia Cardíaca/etiología , Humanos , Población Rural , Población Urbana
5.
Clin Infect Dis ; 65(2): 292-299, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28379374

RESUMEN

BACKGROUND: Reliable data are lacking on pregnancy outcomes during Ebola virus disease (EVD) epidemics. We aimed to characterize symptoms and outcomes among pregnant women admitted to Ebola treatment units (ETUs) with suspected and confirmed EVD to better inform obstetric management. METHODS: We analyzed a retrospective cohort of reproductive-aged women presenting to 5 West African ETUs from September 2014 to September 2015. We compared clinical symptoms, risk of EVD diagnosis, and mortality between pregnant and nonpregnant women. RESULTS: Of 729 reproductive-aged women admitted to study ETUs, 44 (6%) reported pregnancy. Thirteen of 44 pregnant women (30%) tested EVD positive; 6 of 13 (46%) died. Pregnant women were less likely than nonpregnant women to report anorexia, asthenia, diarrhea, fever, myalgias/arthralgias, nausea, or vomiting (P < .05) at admission. Pregnant women with suspected EVD had the same risk, however, of laboratory-confirmed EVD (30% vs 24%, P = .38). While pregnant women with confirmed EVD had similar Ebola viral loads on presentation to nonpregnant women, as measured by initial cycle threshold (26.4 vs 23.2, P = .16), they were less likely to have myalgias/arthralgias (P< .001) and vomiting (P = .02). Both all-cause mortality (14% vs 19%, P = .39) and EVD-specific mortality (46% vs 54%, P = .60) were not significantly different between pregnant and nonpregnant women. Two neonates born live in the ETU died within 8 days. CONCLUSIONS: We find no evidence to support a difference in the risk of death between pregnant women with suspected or confirmed EVD compared to nonpregnant women. Limited data suggest poor fetal and neonatal outcomes in EVD-affected pregnancies.


Asunto(s)
Fiebre Hemorrágica Ebola , Complicaciones Infecciosas del Embarazo , Adulto , Estudios de Cohortes , Brotes de Enfermedades , Ebolavirus/efectos de los fármacos , Ebolavirus/aislamiento & purificación , Femenino , Fiebre/epidemiología , Fiebre Hemorrágica Ebola/mortalidad , Fiebre Hemorrágica Ebola/terapia , Fiebre Hemorrágica Ebola/virología , Hospitalización , Humanos , Lactante , Recién Nacido , Liberia/epidemiología , Mortalidad Materna , Embarazo , Complicaciones Infecciosas del Embarazo/epidemiología , Complicaciones Infecciosas del Embarazo/mortalidad , Complicaciones Infecciosas del Embarazo/terapia , Complicaciones Infecciosas del Embarazo/virología , Resultado del Embarazo , Estudios Retrospectivos , Sierra Leona/epidemiología , Carga Viral , Adulto Joven
7.
J Ultrasound Med ; 36(6): 1189-1194, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28258591

RESUMEN

OBJECTIVES: Few studies of point-of-care ultrasound training and use in low resource settings have reported the impact of examinations on clinical management or the longer-term quality of trainee-performed studies. We characterized the long-term effect of a point-of-care ultrasound program on clinical decision making, and evaluated the quality of clinician-performed ultrasound studies. METHODS: We conducted point-of-care ultrasound training for physicians from Rwandan hospitals. Physicians then used point-of-care ultrasound and recorded their findings, interpretation, and effects on patient management. Data were collected for 6 months. Trainee studies were reviewed for image quality and accuracy. RESULTS: Fifteen participants documented 1158 ultrasounds; 590 studies (50.9%) had matched images and interpretations for review. Abdominal ultrasound for free fluid was the most frequently performed application. The mean image quality score was 2.36 (95% confidence interval, 2.28-2.44). Overall sensitivity and specificity for trainee-performed examinations was 94 and 98%. Point-of-care ultrasound use most commonly changed medications administered (42.4%) and disposition (30%). CONCLUSIONS: A point-of-care ultrasound training intervention in a low-resource setting resulted in high numbers of diagnostic-quality studies over long-term follow-up. Ultrasound use routinely changed clinical decision making.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Toma de Decisiones Clínicas/métodos , Evaluación Educacional/estadística & datos numéricos , Sistemas de Atención de Punto/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Revisión de Utilización de Recursos , Adulto , Estudios de Cohortes , Femenino , Hospitales/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Rwanda/epidemiología , Sensibilidad y Especificidad
8.
Trop Med Int Health ; 21(12): 1531-1538, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27758005

RESUMEN

OBJECTIVE: We delivered a point-of-care ultrasound training programme in a resource-limited setting in Rwanda, and sought to determine participants' knowledge and skill retention. We also measured trainees' assessment of the usefulness of ultrasound in clinical practice. METHODS: This was a prospective cohort study of 17 Rwandan physicians participating in a point-of-care ultrasound training programme. The follow-up period was 1 year. Participants completed a 10-day ultrasound course, with follow-up training delivered over the subsequent 12 months. Trainee knowledge acquisition and skill retention were assessed via observed structured clinical examinations (OSCEs) administered at six points during the study, and an image-based assessment completed at three points. RESULTS: Trainees reported minimal structured ultrasound education and little confidence using point-of-care ultrasound before the training. Mean scores on the image-based assessment increased from 36.9% (95% CI 32-41.8%) before the initial 10-day training to 74.3% afterwards (95% CI 69.4-79.2; P < 0.001). The mean score on the initial OSCE after the introductory course was 81.7% (95% CI 78-85.4%). The mean OSCE performance at each subsequent evaluation was at least 75%, and the mean OSCE score at the 58-week follow up was 84.9% (95% CI 80.9-88.9%). CONCLUSIONS: Physicians providing acute care in a resource-limited setting demonstrated sustained improvement in their ultrasound knowledge and skill 1 year after completing a clinical ultrasound training programme. They also reported improvements in their ability to provide patient care and in job satisfaction.


Asunto(s)
Competencia Clínica , Educación , Examen Físico , Médicos , Sistemas de Atención de Punto , Ultrasonografía , Actitud del Personal de Salud , Evaluación Educacional , Humanos , Satisfacción en el Trabajo , Estudios Prospectivos , Rwanda
9.
Ann Emerg Med ; 64(3): 277-285.e2, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24875894

RESUMEN

The value of point-of-care ultrasound education in resource-limited settings is increasingly recognized, though little guidance exists on how to best construct a sustainable training program. Herein we offer a practical overview of core factors to consider when developing and implementing a point-of-care ultrasound education program in a resource-limited setting. Considerations include analysis of needs assessment findings, development of locally relevant curriculum, access to ultrasound machines and related technological and financial resources, quality assurance and follow-up plans, strategic partnerships, and outcomes measures. Well-planned education programs in these settings increase the potential for long-term influence on clinician skills and patient care.


Asunto(s)
Educación Médica Continua/métodos , Sistemas de Atención de Punto , Ultrasonografía , Costo de Enfermedad , Curriculum , Países en Desarrollo , Recursos en Salud , Humanos , Garantía de la Calidad de Atención de Salud/métodos , Ultrasonografía/instrumentación
11.
Health Aff (Millwood) ; 42(12): 1767-1771, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38048501

RESUMEN

Philadelphia's response to welcoming Afghan evacuees during the COVID-19 pandemic suggests the need for a new approach to immigrant health care.


Asunto(s)
Atención a la Salud , Pandemias , Humanos , Pandemias/prevención & control , Instituciones de Salud
12.
PLOS Glob Public Health ; 2(10): e0000800, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962607

RESUMEN

BACKGROUND: There are limited data on the performance characteristics of ultrasound for the diagnosis of pulmonary tuberculosis in both HIV-positive and HIV-negative persons. The objective of this proof-of-concept study was to determine the sensitivity and specificity of ultrasound for the diagnosis of tuberculosis in adults. METHODS: Comprehensive thoracic and focused abdominal ultrasound examinations were performed by trained radiologists and pulmonologists on adults recruited from a community multimorbidity survey and a primary healthcare clinic in KwaZulu-Natal Province, South Africa. Sputum samples were systematically collected from all participants. Sensitivity and specificity of ultrasound to detect tuberculosis were calculated compared to a reference standard of i) bacteriologically-confirmed tuberculosis, and ii) either bacteriologically-confirmed or radiologic tuberculosis. RESULTS: Among 92 patients (53 [58%] male, mean age 41.9 [standard deviation 13.7] years, 49 [53%] HIV positive), 34 (37%) had bacteriologically-confirmed tuberculosis, 8 (9%) had radiologic tuberculosis with negative bacteriologic studies, and 50 (54%) had no evidence of active tuberculosis. Ultrasound abnormalities on either thoracic or abdominal exams were detected in 31 (91%) participants with bacteriologic tuberculosis and 27 (54%) of those without tuberculosis. Sensitivity and specificity of any ultrasound abnormality for bacteriologically-confirmed tuberculosis were 91% (95% confidence interval [CI] 76%-98%) and 46% (95% CI 32%-61%). Sensitivity and specificity of any ultrasound abnormality for either bacteriologically-confirmed or radiologic tuberculosis were 86% (95% CI 71%-95%) and 46% (95% CI 32%-61%). Overall performance did not appear to differ markedly between participants with and without HIV. CONCLUSION: A comprehensive ultrasound scanning protocol in adults in a high TB burden setting had high sensitivity but low specificity to identify bacteriologically-confirmed tuberculosis.

13.
J Thromb Thrombolysis ; 32(2): 209-14, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21505787

RESUMEN

The optimal method of thromboprophylaxis and the value of screening ultrasonography for detection of deep venous thrombosis (DVT) in neurosurgery patients remains unclear. The goal of this study was to determine the incidence of DVT in neurosurgical patients who, by hospital protocol, receive surveillance ultrasonography of the lower extremities twice weekly, in addition to prophylaxis with unfractionated heparin and external pneumatic compression sleeves. A retrospective review of 7,298 ultrasound studies carried out on 2,593 patients over 4 years at a university neurosurgical hospital was conducted. There was a 7.4% incidence of proximal lower extremity DVT and a 9.7% total incidence including distal DVT. A greater number of distal DVTs were detected with the implementation of whole-leg ultrasonography in the last 2 years of observation. Chart review of 237 patients diagnosed with DVT demonstrated an admitting diagnosis of subarachnoid hemorrhage in nearly half of the patients. The median hospital length of stay for DVT patients was 18 days. Institutional control data demonstrated non-ruptured aneurysm and cerebrovascular anomalies to be the leading reason for admission, followed closely by subarachnoid hemorrhage. The hospital protocol of biweekly screening ultrasound and dual modality prophylaxis for neurosurgery patients resulted in a proximal DVT incidence consistent with that demonstrated by previous studies of standardized dual modality prophylaxis, and higher than that demonstrated in previous studies that employed ultrasound screening protocols.


Asunto(s)
Procedimientos Neuroquirúrgicos , Hemorragia Subaracnoidea , Trombosis de la Vena , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Incidencia , Tiempo de Internación , Extremidad Inferior/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Hemorragia Subaracnoidea/complicaciones , Hemorragia Subaracnoidea/epidemiología , Hemorragia Subaracnoidea/cirugía , Ultrasonografía , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/epidemiología , Trombosis de la Vena/etiología , Trombosis de la Vena/prevención & control
14.
Ultrasound J ; 13(1): 18, 2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33829362

RESUMEN

BACKGROUND: A point-of-care ultrasound education program in obstetrics was developed to train antenatal healthcare practitioners in rural Zanzibar. The study group consisted of 13 practitioners with different training backgrounds: physicians, clinical officers, and nurse/midwives. Trainees received an intensive 2-week antenatal ultrasound course consisting of lectures and hands-on practice followed by 6 months of direct supervision of hands-on scanning and bedside education in their clinical practice environments. Trainees were given a pre-course written exam, a final exam at course completion, and practical exams at 19 and 27 weeks. Trainees were expected to complete written documentation and record ultrasound images of at least 75 proctored ultrasounds. The objective of this study was prospectively to analyze the success of a longitudinal point-of-care ultrasound training program for antepartum obstetrical care providers in Zanzibar. RESULTS: During the 6-month course, trainees completed 1338 ultrasound exams (average 99 exams per trainee with a range of 42-128 and median of 109). Written exam scores improved from a mean of 33.7% (95% CI 28.6-38.8%) at pre-course assessment to 77.5% (95% CI 71-84%) at course completion (P < 0.0001). Practical exam mean scores improved from 71.2% at course midpoint (95% CI 62.3-80.1%) to 84.7% at course completion (95% Cl 78.5-90.8%) (P < 0.0005). Eight of the 13 trainees completed all training requirements including 75 proctored ultrasound exams. CONCLUSION: Trainees improved significantly on all measures after the training program. 62% of the participants completed all requirements. This relatively low completion rate reflects the challenges of establishing ultrasound capacity in this type of setting. Further study is needed to determine trainees' long-term retention of ultrasound skills and the impact of the program on clinical practice and health outcomes.

15.
Int J Emerg Med ; 14(1): 12, 2021 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-33602112

RESUMEN

The COVID-19 pandemic has disrupted traditional global point-of-care ultrasound (POCUS) education and training, as a result of travel restrictions. It has also provided an opportunity for innovation using a virtual platform. Tele-ultrasound and video-conferencing are alternative and supportive tools to augment global POCUS education and training. There is a need to support learners and experts to ensure that maximum benefit is gained from the use of these innovative modalities.

16.
Ultrasound Med Biol ; 47(9): 2589-2597, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34172339

RESUMEN

It is unknown whether and to what extent the penetration depth of lung ultrasound (LUS) influences the accuracy of LUS findings. The current study evaluated and compared the LUS aeration score and two frequently used B-line scores with focal lung aeration assessed by chest computed tomography (CT) at different levels of depth in invasively ventilated intensive care unit (ICU) patients. In this prospective observational study, patients with a clinical indication for chest CT underwent a 12-region LUS examination shortly before CT scanning. LUS images were compared with corresponding regions on the chest CT scan at different subpleural depths. For each LUS image, the LUS aeration score was calculated. LUS images with B-lines were scored as the number of separately spaced B-lines (B-line count score) and the percentage of the screen covered by B-lines divided by 10 (B-line percentage score). The fixed-effect correlation coefficient (ß) was presented per 100 Hounsfield units. A total of 40 patients were included, and 372 regions were analyzed. The best association between the LUS aeration score and CT was found at a subpleural depth of 5 cm for all LUS patterns (ß = 0.30, p < 0.001), 1 cm for A- and B1-patterns (ß = 0.10, p < 0.001), 6 cm for B1- and B2-patterns (ß = 0.11, p < 0.001) and 4 cm for B2- and C-patterns (ß = 0.07, p = 0.001). The B-line percentage score was associated with CT (ß = 0.46, p = 0.001), while the B-line count score was not (ß = 0.07, p = 0.305). In conclusion, the subpleural penetration depth of ultrasound increased with decreased aeration reflected by the LUS pattern. The LUS aeration score and the B-line percentage score accurately reflect lung aeration in ICU patients, but should be interpreted while accounting for the subpleural penetration depth of ultrasound.


Asunto(s)
Pulmón , Tomografía Computarizada por Rayos X , Cuidados Críticos , Humanos , Unidades de Cuidados Intensivos , Pulmón/diagnóstico por imagen , Ultrasonografía
17.
AEM Educ Train ; 5(1): 79-90, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33521495

RESUMEN

To date, the practice of global emergency medicine (GEM) has involved being "on the ground" supporting in-country training of local learners, conducting research, and providing clinical care. This face-to-face interaction has been understood as critically important for developing partnerships and building trust. The COVID-19 pandemic has brought significant uncertainty worldwide, including international travel restrictions of indeterminate permanence. Following the 2020 Society for Academic Emergency Medicine meeting, the Global Emergency Medicine Academy (GEMA) sought to enhance collective understanding of best practices in GEM training with a focus on multidirectional education and remote collaboration in the setting of COVID-19. GEMA members led an initiative to outline thematic areas deemed most pertinent to the continued implementation of impactful GEM programming within the physical and technologic confines of a pandemic. Eighteen GEM practitioners were divided into four workgroups to focus on the following themes: advances in technology, valuation, climate impacts, skill translation, research/scholastic projects, and future challenges. Several opportunities were identified: broadened availability of technology such as video conferencing, Internet, and smartphones; online learning; reduced costs of cloud storage and printing; reduced carbon footprint; and strengthened local leadership. Skills and knowledge bases of GEM practitioners, including practicing in resource-poor settings and allocation of scarce resources, are translatable domestically. The COVID-19 pandemic has accelerated a paradigm shift in the practice of GEM, identifying a previously underrecognized potential to both strengthen partnerships and increase accessibility. This time of change has provided an opportunity to enhance multidirectional education and remote collaboration to improve global health equity.

18.
JMIR Mhealth Uhealth ; 8(10): e20419, 2020 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-33006942

RESUMEN

BACKGROUND: Telehealth has emerged as a crucial component of the SARS-CoV-2 pandemic emergency response. Simply stated, telehealth is a tool to provide health care from a distance. Jefferson Health has leveraged its acute care telehealth platform to screen, order testing, and manage patients with COVID-19-related concerns. OBJECTIVE: This study aims to describe the expansion and results of using a telehealth program to increase access to care while minimizing additional potential exposures during the early period of the COVID-19 pandemic. METHODS: Screening algorithms for patients with SARS-CoV-2-related complaints were created, and 150 new clinicians were trained within 72 hours to address increased patient demand. Simultaneously, Jefferson Health created mobile testing sites throughout eastern Pennsylvania and the southern New Jersey region. Visit volume, the number of SARS-CoV-2 tests ordered, and the number of positive tests were evaluated, and the volume was compared with preceding time periods. RESULTS: From March 8, 2020, to April 11, 2020, 4663 patients were screened using telehealth, representing a surge in visit volume. There were 1521 patients sent to mobile testing sites, and they received a telephone call from a centralized call center for results. Of the patients who were tested, nearly 20% (n=301) had a positive result. CONCLUSIONS: Our model demonstrates how using telehealth for a referral to central testing sites can increase access to community-based care, decrease clinician exposure, and minimize the demand for personal protective equipment. The scaling of this innovation may allow health care systems to focus on preparing for and delivering hospital-based care needs.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Servicios de Salud Comunitaria/organización & administración , Telemedicina , Prueba de COVID-19 , Infecciones por Coronavirus/diagnóstico , Humanos , New Jersey/epidemiología , Pennsylvania/epidemiología
19.
West J Emerg Med ; 21(4): 1022-1028, 2020 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-32726278

RESUMEN

INTRODUCTION: Tricuspid annular plane systolic excursion (TAPSE) is an established echocardiographic marker of right ventricular (RV) systolic function. The objective of this study was to evaluate whether emergency clinicians can visually estimate RV function using TAPSE in a set of video clips compared to a reference standard M-mode measurement. METHODS: Emergency clinicians were shown a five-minute educational video on TAPSE. Participants then viewed 20 apical four-chamber point-of-care ultrasound (POCUS) echocardiography clips and recorded their estimate of TAPSE distance in centimeters (cm), as well as whether TAPSE was normal (>1.9 cm), borderline (1.5-1.9 cm), or abnormal (<1.5 cm). We calculated sensitivity, specificity, and overall accuracy of visual TAPSE categorization using M-mode measurement as the criterion standard. Participants also reported their comfort with assessing TAPSE on a five-point Likert scale before and after participation in the study. RESULTS: Among 70 emergency clinicians, including 20 postgraduate year 1-4 residents, 22 attending physicians, and 28 physician assistants (PA), the pooled sensitivity and specificity for visual assessment of TAPSE was 88.6% (95% confidence interval, 85.4-91.7%) and 81.6% (95% CI, 78.2-84.4%), respectively. The sensitivity and specificity for the clips in which the measured TAPSE was <1.5 cm or >1.9 cm was 91.4% (95% CI, 88.4-94.3%) and 90.8% (95% CI, 87.7-93.9%), respectively. There was no significant difference in sensitivity (p = 0.27) or specificity (p = 0.55) between resident and attending physicians or between physicians and PAs (p = 0.17 and p = 0.81). Median self-reported comfort with TAPSE assessment increased from 1 (interquartile range [IQR] 1-2) to 3 (IQR 3-4) points after participation in the study. CONCLUSION: A wide range of emergency clinicians demonstrated fair accuracy for visual estimation of TAPSE on previously recorded POCUS echocardiography video clips. These findings should be considered hypothesis generating and warrant validation in larger, prospective studies.


Asunto(s)
Ecocardiografía , Servicios Médicos de Urgencia , Válvula Tricúspide/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico , Función Ventricular Derecha/fisiología , Ecocardiografía/métodos , Ecocardiografía/normas , Servicios Médicos de Urgencia/métodos , Servicios Médicos de Urgencia/normas , Humanos , Pruebas en el Punto de Atención , Estudios Prospectivos , Sensibilidad y Especificidad , Válvula Tricúspide/fisiopatología , Disfunción Ventricular Derecha/fisiopatología
20.
Am J Trop Med Hyg ; 104(2): 478-486, 2020 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-33319731

RESUMEN

Critically ill parturients have an increased risk of developing pulmonary complications. Lung ultrasound (LUS) could be effective in addressing the cause of respiratory distress in resource-limited settings with high maternal mortality. We aimed to determine the frequency, timing of appearance, and type of pulmonary complications in critically ill parturients in an obstetric unit in Sierra Leone. In this prospective observational study, LUS examinations were performed on admission, after 24 and 48 hours, and in case of respiratory deterioration. Primary endpoint was the proportion of parturients with one or more pulmonary complications, stratified for the presence of respiratory distress. Secondary endpoints included timing and types of complications, and their association with "poor outcome," defined as a composite of transfer for escalation of care or death. Of 166 patients enrolled, 35 patients (21% [95% CI: 15-28]) had one or more pulmonary complications, the majority diagnosed on admission. Acute respiratory distress syndrome (period prevalence 4%) and hydrostatic pulmonary edema (4%) were only observed in patients with respiratory distress. Pneumonia (2%), atelectasis (10%), and pleural effusion (7%) were present, irrespective of respiratory distress. When ultrasound excluded pulmonary complications, respiratory distress was related to anemia or metabolic acidosis. Pulmonary complications were associated with an increased risk of poor outcome (odds ratio: 5.0; 95% CI: 1.7-14.6; P = 0.003). In critically ill parturients in a resource-limited obstetric unit, LUS contributed to address the cause of respiratory distress by identifying or excluding pulmonary complications. These were associated with a poor outcome.


Asunto(s)
Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Complicaciones del Embarazo/diagnóstico por imagen , Ultrasonografía/normas , Adulto , Enfermedad Crítica/epidemiología , Femenino , Humanos , Neumonía/diagnóstico por imagen , Embarazo , Estudios Prospectivos , Edema Pulmonar/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Sierra Leona , Ultrasonografía/economía , Ultrasonografía/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA