Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Environ Sci Technol ; 58(20): 8825-8834, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38712863

RESUMEN

Flame retardants (FRs) are added to vehicles to meet flammability standards, such as US Federal Motor Vehicle Safety Standard FMVSS 302. However, an understanding of which FRs are being used, sources in the vehicle, and implications for human exposure is lacking. US participants (n = 101) owning a vehicle of model year 2015 or newer hung a silicone passive sampler on their rearview mirror for 7 days. Fifty-one of 101 participants collected a foam sample from a vehicle seat. Organophosphate esters (OPEs) were the most frequently detected FR class in the passive samplers. Among these, tris(1-chloro-isopropyl) phosphate (TCIPP) had a 99% detection frequency and was measured at levels ranging from 0.2 to 11,600 ng/g of sampler. TCIPP was also the dominant FR detected in the vehicle seat foam. Sampler FR concentrations were significantly correlated with average ambient temperature and were 2-5 times higher in the summer compared to winter. The presence of TCIPP in foam resulted in ∼4 times higher median air sampler concentrations in winter and ∼9 times higher in summer. These results suggest that FRs used in vehicle interiors, such as in seat foam, are a source of OPE exposure, which is increased in warmer temperatures.


Asunto(s)
Retardadores de Llama , Retardadores de Llama/análisis , Humanos , Temperatura , Exposición a Riesgos Ambientales , Vehículos a Motor
2.
Environ Res ; 258: 119465, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38908658

RESUMEN

In the United States and abroad, ortho-phthalates and non-ortho-phthalate plasticizers continue to be used within a diverse array of consumer products. Prior California-specific biomonitoring programs for ortho-phthalates have focused on rural, agricultural communities and, to our knowledge, these programs have not measured the potential for exposure to non-ortho-phthalate plasticizers. Therefore, the potential for human exposure to ortho-phthalates and non-ortho-phthalate plasticizers have not been adequately addressed in regions of California that have higher population density. Since there are numerous sources of ortho-phthalates and non-ortho-phthalate plasticizers in population-dense, urban regions, the objective of this study was to leverage silicone wristbands to quantify aggregate ortho-phthalate and non-ortho-phthalate plasticizer exposure over a 5-day period across two different cohorts (2019 and 2020) of undergraduate students at the University of California, Riverside (UCR) that commute from all over Southern California. Based on 5 d of aggregate exposure across two different cohorts, total ortho-phthalate plus non-ortho-phthalate plasticizer concentrations ranged, on average, from ∼100,000-1,000,000 ng/g. Based on the distribution of individual ortho-phthalate and non-ortho-phthalate plasticizer concentrations, the concentrations of di-isononyl phthalate (DiNP, a high molecular weight ortho-phthalate), di (2-ethylhexyl) phthalate (DEHP, a high molecular weight ortho-phthalate), and di-2-ethylhexyl terephthalate (DEHT, a non-ortho-phthalate plasticizer) detected within wristbands were higher than the remaining seven ortho-phthalates and non-ortho-phthalate plasticizers measured, accounting for approximately 94-97% of the total mass depending on the cohort. Overall, our findings raise concerns about chronic DiNP, DEHP, and DEHT exposure in urban, population-dense regions throughout California.

3.
Environ Sci Technol ; 56(2): 1149-1161, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34964617

RESUMEN

Pesticides are used extensively in residential settings for lawn maintenance and in homes to control household pests including application directly on pets to deter fleas and ticks. Pesticides are commonly detected in the home environment where people and pets can be subject to chronic exposure. Due to increased interest in using companion animals as sentinels for human environmental health studies, we conducted a comparative pesticide exposure assessment in 30 people and their pet dogs to determine how well silicone wristbands and silicone dog tags can predict urinary pesticide biomarkers of exposure. Using targeted gas chromatography-mass spectrometry analyses, we quantified eight pesticides in silicone samplers and used a suspect screening approach for additional pesticides. Urine samples were analyzed for 15 pesticide metabolite biomarkers. Several pesticides were detected in >70% of silicone samplers including permethrin, N,N-diethyl-meta-toluamide (DEET), and chlorpyrifos. Significant and positive correlations were observed between silicone sampler levels of permethrin and DEET with their corresponding urinary metabolites (rs = 0.50-0.96, p < 0.05) in both species. Significantly higher levels of fipronil were observed in silicone samplers from participants who reported using flea and tick products containing fipronil on their dog. This study suggests that people and their dogs have similar pesticide exposures in a home environment.


Asunto(s)
Cloropirifos , Plaguicidas , Animales , Monitoreo Biológico , Perros , Exposición a Riesgos Ambientales/análisis , Monitoreo del Ambiente , Humanos , Plaguicidas/análisis , Siliconas
4.
Environ Sci Technol ; 56(2): 1162-1173, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34985261

RESUMEN

Anti-fog sprays and solutions are used on eyeglasses to minimize the condensation of water vapor, particularly while wearing a mask. Given their water-repellent properties, we sought to characterize per- and polyfluorinated alkyl substance (PFAS) compounds in four anti-fog spray products, five anti-fog cloth products, and two commercial fluorosurfactant formulations suspected to be used in preparing anti-fog products. Fluorotelomer alcohols (FTOHs) and fluorotelomer ethoxylates (FTEOs) were detected in all products and formulations. While 6:2 FTOH and the 6:2 FTEO polymeric series were predominant, one anti-fog cloth and one formulation contained 8:2, 10:2, 12:2, 14:2, and 16:2 FTOH and FTEO polymeric series. PFAS concentrations varied in samples and were detected at levels up to 25,000 µg/mL in anti-fog sprays and 185,000 µg (g cloth)-1 in anti-fog cloth products. The total organic fluorine (TOF) measurements of anti-fog products ranged from 190 to 20,700 µg/mL in sprays and 44,200 to 131,500 µg (g cloth)-1 in cloths. Quantified FTOHs and FTEOs accounted for 1-99% of TOF mass. In addition, all four anti-fog sprays and both commercial formulations exhibited significant cytotoxicity and adipogenic activity (either triglyceride accumulation and/or pre-adipocyte proliferation) in murine 3T3-L1 cells. Results suggest that FTEOs are a significant contributor to the adipogenic activity exhibited by the anti-fog sprays. Altogether, these results suggest that FTEOs are present in commercial products at toxicologically relevant levels, and more research is needed to fully understand the health risks from using these PFAS-containing products.


Asunto(s)
Fluorocarburos , Alcoholes , Animales , Flúor , Ratones
5.
Environ Res ; 205: 112525, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-34896084

RESUMEN

Organophosphate esters (OPEs) have been detected within car interior dust, suggesting that the indoor microenvironment of vehicles may represent a potential route of human exposure to OPEs. We recently showed that people with longer commutes are exposed to higher concentrations of tris(1,3-dichloro-2-isopropyl)phosphate (TDCIPP) - a widely used OPE - and other studies have suggested that dust removal may lead to lower exposure to chemicals. Therefore, the overall objective of this study was to determine if a decrease in interior car dust results in mitigation of personal OPE exposure. Participants (N = 49) were asked to wear silicone wristbands, and a subset of them wiped interior parts at the front of their vehicles prior to one study week (N = 25) or both study weeks (N = 11). There were no significant differences in total OPE concentrations (77.79-13,660 ng/g) nor individual OPE concentrations (0.04-4852.81 ng/g) across the different wiping groups nor in relation to participant residence ZIP codes and AC/Heater usage. These findings suggest that higher exposure to TDCIPP for participants with longer commutes may be independent of dust located on interior parts at the front of the vehicle. Therefore, our study demonstrates that there is a need for research on the potential contribution of other sources of TDCIPP exposure within car interiors.


Asunto(s)
Polvo , Retardadores de Llama , China , Polvo/análisis , Exposición a Riesgos Ambientales/análisis , Monitoreo del Ambiente , Ésteres/análisis , Retardadores de Llama/análisis , Humanos , Organofosfatos/análisis
6.
Chem Res Toxicol ; 33(6): 1428-1441, 2020 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-32129605

RESUMEN

Isopropylated and tert-butylated triarylphosphate esters (ITPs and TBPPs, respectively) are plasticizers and flame retardants that are ubiquitous in indoor environments; however, no studies to date have characterized their metabolism. Using human liver subcellular S9 fractions, phase I and II in vitro metabolism of triphenyl phosphate (TPHP), 4-tert-butylphenyl diphenyl phosphate (4tBPDPP), 2-isopropylphenyl diphenyl phosphate (2IPPDPP), and 4-isopropylphenyl diphenyl phosphate (4IPPDPP) was investigated at 1 and 10 µM doses. Parent depletion and the formation of known or suspected metabolites (e.g., likely hydrolysis or hydroxylated products), including diphenyl phosphate (DPHP), hydroxyl-triphenyl phosphate (OH-TPHP), isopropylphenyl phenyl phosphate (ip-PPP), and tert-butylphenyl phenyl phosphate (tb-PPP), were monitored and quantified via GC/MS or LC-MS/MS. tb-PPP and its conjugates were identified as the major in vitro metabolites of 4tBPDPP and accounted for 71% and 49%, respectively, of the parent molecule that was metabolized during the incubation. While the mass balance between parents and metabolites was conserved for TPHP and 4tBPDPP, approximately 20% of the initial parent mass was unaccounted for after quantifying suspected metabolites of 2IPPDPP and 4IPPDPP that had authentic standards available. Two novel ITP metabolites, mono-isopropenylphenyl diphenyl phosphate and hydroxy-isopropylphenyl diphenyl phosphate, were tentatively identified by high-resolution mass spectrometry and screened for in recently collected human urine where mono-isopropenylphenyl diphenyl phosphate was detected in one of nine samples analyzed. This study provides insight into the biological fate of ITP and TBPP isomers in human tissues and is useful in identifying appropriate biomarkers of exposure to monitor, particularly in support of epidemiological studies.


Asunto(s)
Contaminantes Ambientales/metabolismo , Ésteres/metabolismo , Retardadores de Llama/metabolismo , Hígado/metabolismo , Organofosfatos/metabolismo , Plastificantes/metabolismo , Fracciones Subcelulares/metabolismo , Biotransformación , Niño , Preescolar , Contaminantes Ambientales/orina , Ésteres/orina , Humanos , Organofosfatos/orina
7.
Environ Sci Technol ; 54(12): 7409-7419, 2020 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-32401030

RESUMEN

Silicone wristbands are promising passive samplers to support epidemiological studies in characterizing exposure to organic contaminants; however, investigating associated health risks remains challenging because of the latency period for many chronic diseases that take years to manifest. Dogs provide valuable insights as sentinels for exposure-related human disease because they share similar exposures in the home, have shorter life spans, share many clinical/biological features, and have closely related genomes. Here, we evaluated exposures among pet dogs and their owners using silicone dog tags and wristbands to determine if contaminant levels were correlated with validated exposure biomarkers. Significant correlations between measures on dog tags and wristbands were observed (rs = 0.38-0.90; p < 0.05). Correlations with their respective urinary biomarkers were stronger in dog tags compared to that in human wristbands (rs = 0.50-0.71; p < 0.01) for several organophosphate esters. This supports the value of using silicone bands with dogs to investigate health impacts on humans from shared exposures.


Asunto(s)
Monitoreo del Ambiente , Siliconas , Animales , Biomarcadores , Perros , Humanos , Organofosfatos
8.
Environ Sci Technol ; 54(23): 15296-15312, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33185092

RESUMEN

Research suggests that thyroid cancer incidence rates are increasing, and environmental exposures have been postulated to be playing a role. To explore this possibility, we conducted a pilot study to investigate the thyroid disrupting bioactivity of chemical mixtures isolated from personal silicone wristband samplers within a thyroid cancer cohort. Specifically, we evaluated TRß antagonism of chemical mixtures extracted from wristbands (n = 72) worn by adults in central North Carolina participating in a case-control study on papillary thyroid cancer. Sections of wristbands were solvent-extracted and analyzed via mass spectrometry to quantify a suite of semivolatile chemicals. A second extract from each wristband was used in a bioassay to quantify TRß antagonism in human embryonic kidney cells (HEK293/17) at concentrations ranging from 0.1 to 10% of the original extract (by volume). Approximately 70% of the sample extracts tested at a 1% extract concentration exhibited significant TRß antagonism, with a mean of 30% and a range of 0-100%. Inhibited cell viability was noted in >20% of samples that were tested at 5 and 10% concentrations. Antagonism was positively associated with wristband concentrations of several phthalates, organophosphate esters, and brominated flame retardants. These results suggest that personal passive samplers may be useful in evaluating the bioactivities of mixtures that people contact on a daily basis. We also report tentative associations between thyroid receptor antagonism, chemical concentrations, and papillary thyroid cancer case status. Future research utilizing larger sample sizes, prospective data collection, and measurement of serum thyroid hormone levels (which were not possible in this study) should be utilized to more comprehensively evaluate these associations.


Asunto(s)
Retardadores de Llama , Neoplasias de la Tiroides , Adulto , Antitiroideos , Estudios de Casos y Controles , Monitoreo del Ambiente , Retardadores de Llama/análisis , Células HEK293 , Éteres Difenilos Halogenados/análisis , Humanos , North Carolina , Proyectos Piloto , Estudios Prospectivos , Siliconas , Cáncer Papilar Tiroideo
9.
Environ Sci Technol ; 52(9): 5154-5160, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29667399

RESUMEN

Both Aroclor and non-Aroclor sources of airborne polychlorinated biphenyls (PCBs) were found in residential homes. We deployed passive air samplers at 16 residences and found PCB-47, PCB-51, and PCB-68 to account for up to 50% of measured indoor ΣPCBs (2700 pg m-3). Although PCB-47 and PCB-51 are neurotoxins present in Aroclor mixtures (<2.5 and <0.3 wt %, respectively), we found them at much higher levels than expected for any Aroclor source. PCB-68 is not present in Aroclor mixtures. Another non-Aroclor congener, PCB-11, a byproduct of pigment manufacturing, was found inside and outside of every household and was frequently the predominate congener. We conducted direct measurements of surface emissions and identified finished cabinetry to be a major source of PCB-47, PCB-51, and PCB-68. We hypothesize that these congeners are inadvertent byproducts of polymer sealant manufacturing and produced from the decomposition of 2,4-dichlorobenzoyl peroxide used as an initiator in free-radical polymerization of polyester resins. The presence of these three compounds in polymer products, such as silicone, has been widely noted, but to our knowledge they have never been shown to be a significant environmental source of PCBs.


Asunto(s)
Bifenilos Policlorados , Arocloros , Materiales de Construcción , Polímeros
10.
Environ Sci Technol ; 51(14): 7853-7860, 2017 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-28656752

RESUMEN

PCBs appear in school air because many school buildings were built when PCBs were still intentionally added to building materials and because PCBs are also present through inadvertent production in modern pigment. This is of concern because children are especially vulnerable to the toxic effects of PCBs. Here we report indoor and outdoor air concentrations of PCBs and OH-PCBs from two rural schools and four urban schools, the latter near a PCB-contaminated waterway of Lake Michigan in the United States. Samples (n = 108) were collected as in/out pairs using polyurethane foam passive air samplers (PUF-PAS) from January 2012 to November 2015. Samples were analyzed using GC/MS-MS for all 209 PCBs and 72 OH-PCBs. Concentrations inside schools were 1-2 orders of magnitude higher than outdoors and ranged from 0.5 to 194 ng/m3 (PCBs) and from 4 to 665 pg/m3 (OH-PCBs). Congener profiles were similar within each sampling location across season but different between schools and indicated the sources as Aroclors from building materials and individual PCBs associated with modern pigment. This study is the first cohort-specific analysis to show that some children's PCB inhalation exposure may be equal to or higher than their exposure through diet.


Asunto(s)
Contaminantes Atmosféricos , Bifenilos Policlorados , Población Rural , Instituciones Académicas , Arocloros , Niño , Monitoreo del Ambiente , Humanos , Exposición por Inhalación , Michigan
11.
Environ Sci Technol ; 50(13): 6690-7, 2016 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-26963482

RESUMEN

We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF-PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA's National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF-PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8.


Asunto(s)
Contaminantes Atmosféricos , Monitoreo del Ambiente , Modelos Teóricos , Bifenilos Policlorados , Viento
12.
Environ Pollut ; 349: 123877, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38574945

RESUMEN

Silicone wristbands are a noninvasive personal exposure assessment tool. However, despite their utility, questions remain about the rate at which chemicals accumulate on wristbands when worn, as validation studies utilizing wristbands worn by human participants are limited. This study evaluated the chemical uptake rates of 113 organic pollutants from several chemical classes (i.e., polychlorinated biphenyls (PCB), organophosphate esters (OPEs), alkyl OPEs, polybrominated diphenyl ethers (PBDEs), brominated flame retardants (BFR), phthalates, pesticides, and polycyclic aromatic hydrocarbons (PAHs) over a five-day period. Adult participants (n = 10) were asked to wear five silicone wristbands and then remove one wristband each day. Several compounds were detected in all participants' wristbands after only one day. The number of chemicals detected frequently (i.e. in at least seven participants wristbands) increased from 20% of target compounds to 26% after three days and more substantially increased to 34% of target compounds after four days of wear. Chemicals detected in at least seven participants' day five wristbands (n = 24 chemicals) underwent further statistical analysis, including estimating the chemical uptake rates over time. Some chemicals, including pesticides and phthalates, had postive and significant correlations between concentrations on wristbands worn five days and concentrations of wristbands worn fewer days suggesting chronic exposure. For 23 of the 24 compounds evaluated there was a statistically significant and positive linear association between the length of time wristbands were worn and chemical concentrations in wristbands. Despite the differences that exist between laboratory studies using polydimethylsiloxane (PDMS) environmental samplers and worn wristbands, these results indicate that worn wristbands are primarily acting as first-order kinetic samplers. These results suggest that studies using different deployment lengths should be comparable when results are normalized to the length of the deployment period. In addition, a shorter deployment period could be utilized for compounds that were commonly detected in as little as one day.


Asunto(s)
Monitoreo del Ambiente , Contaminantes Ambientales , Retardadores de Llama , Siliconas , Humanos , Adulto , Retardadores de Llama/análisis , Contaminantes Ambientales/análisis , Monitoreo del Ambiente/métodos , Masculino , Femenino , Exposición a Riesgos Ambientales/estadística & datos numéricos , Exposición a Riesgos Ambientales/análisis , Éteres Difenilos Halogenados/análisis , Bifenilos Policlorados/análisis , Hidrocarburos Policíclicos Aromáticos/análisis , Plaguicidas/análisis , Adulto Joven , Muñeca , Ácidos Ftálicos/análisis
13.
Chemosphere ; 339: 139778, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37567263

RESUMEN

Silicone wristbands were utilized as personal passive samplers in a sub-cohort of 92 women, who participated in New York University Children's Health and Environment Study, to assess exposure to semi-volatile organic compounds (SVOCs). Wristbands were analyzed for 77 SVOCs, including halogenated and non-halogenated organophosphate esters (OPEs), polychlorinated biphenyls (PCBs), pesticides, phthalates, and brominated flame retardants (BFRs) (e.g. polybrominated diphenyl ethers (PBDEs)). This study aimed to look for patterns in chemical exposure utilizing participant demographics gathered from a questionnaire, and chemical exposure data across multiple timepoints during pregnancy. Analysis focused on 27 compounds detected in at least 80% of the wristbands examined. The chemicals detected most frequently included two pesticides, eight phthalates, one phthalate alternative, seven BFRs, and nine OPEs, including isopropylated and tert-butylated triarylphosphate esters (ITPs and TBPPs). Co-exposure to different SVOCs was most prominent in compounds that were within the same chemical class or were used in similar consumer applications such as phthalates and OPEs, which are often used as plasticizers. Pre-pregnancy BMI was positively associated with multiple compounds, and there were both positive and negative associations between women's parity and SVOC exposure. Outdoor temperature was not correlated with the wristband concentrations over a five-day sampling period. Lastly, significant and moderately high Intraclass Correlation Coefficient (ICC) (0.66-0.84) values for phthalate measurementsacross pregnancy indicate chronic exposure and suggest that using wristbands during one sampling period may reliably predict exposure. However, multiple sampling periods may be necessary to accurately determine indoor exposure to other SVOCs including OPEs and BFRs.


Asunto(s)
Retardadores de Llama , Plaguicidas , Compuestos Orgánicos Volátiles , Niño , Humanos , Femenino , Embarazo , Siliconas/química , Monitoreo del Ambiente , Compuestos Orgánicos Volátiles/análisis , Organofosfatos/análisis , Plaguicidas/análisis , Retardadores de Llama/análisis , Éteres Difenilos Halogenados/análisis , Ésteres
14.
Chemosphere ; 315: 137705, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36592838

RESUMEN

Humans are exposed to increasingly complex mixtures of hormone-disrupting chemicals from a variety of sources, yet, traditional research methods only evaluate a small number of chemicals at a time. We aimed to advance novel methods to investigate exposures to complex chemical mixtures. Silicone wristbands were worn by 243 office workers in the USA, UK, China, and India during four work shifts. We analyzed extracts of the wristbands for: 1) 99 known (targeted) chemicals; 2) 1000+ unknown chemical features, tentatively identified through suspect screening; and 3) total hormonal activities towards estrogen (ER), androgen (AR), and thyroid hormone (TR) receptors in human cell assays. We evaluated associations of chemicals with hormonal activities using Bayesian kernel machine regression models, separately for targeted versus suspect chemicals (with detection ≥50%). Every wristband exhibited hormonal activity towards at least one receptor: 99% antagonized TR, 96% antagonized AR, and 58% agonized ER. Compared to men, women were exposed to mixtures that were more estrogenic (180% higher, adjusted for country, age, and skin oil abundance in wristband), anti-androgenic (110% higher), and complex (median 836 detected chemical features versus 780). Adjusted models showed strong associations of jointly increasing chemical concentrations with higher hormonal activities. Several targeted and suspect chemicals were important co-drivers of overall mixture effects, including chemicals used as plasticizers, fragrance, sunscreen, pesticides, and from other or unknown sources. This study highlights the role of personal care products and building microenvironments in hormone-disrupting exposures, and the substantial contribution of chemicals not often identifiable or well-understood to those exposures.


Asunto(s)
Disruptores Endocrinos , Plaguicidas , Masculino , Humanos , Femenino , Siliconas , Teorema de Bayes , Estrógenos , Plaguicidas/análisis , Mezclas Complejas , Andrógenos , Disruptores Endocrinos/análisis
15.
Sci Total Environ ; 834: 155237, 2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-35447169

RESUMEN

Firefighters are occupationally exposed to an array of hazardous chemicals, and these exposures have been linked to the higher rates of some cancer in firefighters. However, additional research that characterizes firefighters' exposure is needed to fully elucidate the impacts on health risks. In this pilot study, we used silicone wristbands to quantify off-duty and on-duty chemical exposures experienced by 20 firefighters in Durham, North Carolina. By using each firefighter's off-duty wristband to represent individual baseline exposures, we assessed occupation-related exposures (i.e. on-duty exposures). We also investigated the influence of responding to a fire event while on-duty. In total, 134 chemicals were quantified using both GC-MS and LC-MS/MS targeted methods. Seventy-one chemicals were detected in at least 50% of all silicone wristbands, including 7 PFAS, which to our knowledge, have not been reported in wristbands previously. Of these, phthalates were generally measured at the highest concentrations, followed by brominated flame retardants (BFRs) and organophosphate esters (OPEs). PFAS were measured at lower concentrations overall, but firefighter PFOS exposures while on-duty and responding to fires were 2.5 times higher than off-duty exposures. Exposure to polycyclic aromatic hydrocarbons (PAH), BFRs, and some OPEs were occupationally associated, with firefighters experiencing 0.5 to 8.5 times higher exposure while on-duty as compared to off-duty. PAH exposures were also higher for firefighters who respond to a fire than those who did not while on-duty. Additional research with a larger population of firefighters that builds upon this pilot investigation may further pinpoint exposure sources that may contribute to firefighters' risk for cancer, such as those from firefighter gear or directly from fires. This research demonstrates the utility of using silicone wristbands to quantify occupational exposure in firefighters and the ability to disentangle exposures that may be specific to fire events as opposed to other sources that firefighters might experience.


Asunto(s)
Contaminantes Ocupacionales del Aire , Bomberos , Incendios , Retardadores de Llama , Fluorocarburos , Neoplasias , Exposición Profesional , Hidrocarburos Policíclicos Aromáticos , Contaminantes Ocupacionales del Aire/análisis , Cromatografía Liquida , Retardadores de Llama/análisis , Humanos , Exposición Profesional/análisis , Organofosfatos , Proyectos Piloto , Hidrocarburos Policíclicos Aromáticos/análisis , Siliconas , Espectrometría de Masas en Tándem
16.
Environ Sci Technol Lett ; 8(9): 805-810, 2021 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-36159219

RESUMEN

Silicone wristbands present a noninvasive exposure assessment tool and an alternative to traditional biomonitoring; however, questions about their utility remain as validation studies are limited. We sought to determine if wristbands provide quantitative estimates of internal organophosphate ester (OPE) exposure. We evaluated internal dose by measuring metabolite masses excreted in 24-hour urine samples collected over five days among ten adults. We compared internal dose to OPE concentrations in paired wristbands worn during collection and, as a comparison, evaluated metabolite levels in spot urine samples. Three of six OPE metabolites evaluated were detected in >98% of urine samples, and 24 of 34 assessed OPEs were detected in at least one wristband. OPE uptake in wristbands was linear over time (range=0.54-61.8 ng/g/day). OPE concentrations in spot urine and wristbands were not correlated with total diphenyl phosphate (DPHP) excreted in urine, which may be due to the range of possible DPHP parent compounds or dietary exposure. However, for tris-(1,3-dichloro-2-propyl)phosphate (TDCIPP) and tris-(2-chloroisopropyl)phosphate (TCIPP), wristbands and spot urine samples were both moderately to strongly correlated with internal dose (all rs>0.56 and p<0.1), suggesting both perform well as integrated exposure estimates. Given the potential advantages of silicone wristbands, further studies investigating additional compounds are warranted.

17.
Environ Int ; 156: 106727, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34425641

RESUMEN

Little is known about chemical contaminant exposures of office workers in buildings globally. Complex mixtures of harmful chemicals accumulate indoors from building materials, building maintenance, personal products, and outdoor pollution. We evaluated exposures to 99 chemicals in urban office buildings in the USA, UK, China, and India using silicone wristbands worn by 251 participants while they were at work. Here, we report concentrations of polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and other brominated flame retardants (BFRs), organophosphate esters (OPEs), phthalates and phthalate alternatives, pesticides, and polycyclic aromatic hydrocarbons (PAHs). First, we found major differences in office worker chemical exposures by country, some of which can be explained by regulations and use patterns. For example, exposures to several pesticides were substantially higher in India where there were fewer restrictions and unique malaria challenges, and exposures to flame retardants tended to be higher in the USA and UK where there were historic, stringent furniture flammability standards. Higher exposures to PAHs in China and India could be due to high levels of outdoor air pollution that penetrates indoors. Second, some office workers were still exposed to legacy PCBs, PBDEs, and pesticides, even decades after bans or phase-outs. Third, we identified exposure to a contemporary PCB that is not covered under legacy PCB bans due to its presence as an unintentional byproduct in materials. Fourth, exposures to novel BFRs, OPEs, and other chemicals commonly used as substitutes to previously phased-out chemicals were ubiquitous. Fifth, some exposures were influenced by individual factors, not just countries and buildings. Phthalate exposures, for example, were related to personal care product use, country restrictions, and building materials. Overall, we found substantial country differences in chemical exposures and continued exposures to legacy phased-out chemicals and their substitutes in buildings. These findings warrant further research on the role of chemicals in office buildings on worker health.


Asunto(s)
Contaminación del Aire Interior , Retardadores de Llama , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Retardadores de Llama/análisis , Éteres Difenilos Halogenados/análisis , Humanos , Siliconas , Reino Unido , Estados Unidos
18.
Environ Int ; 136: 105499, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31999975

RESUMEN

Organophosphate esters (OPEs) are a class of semi-volatile organic compounds (SVOCs) used as flame retardants, plasticizers, and anti-foaming agents. Due to stringent flammability standards in vehicles and the ability of OPEs to migrate out of end-use products, elevated concentrations of OPEs have been found in car dust samples around the world. As many residents of Southern California spend a significant amount of time in their vehicles, there is potential for increased exposure to OPEs associated with longer commute times. As approximately 70% of the University of California, Riverside's undergraduate population commutes, the objective of this study was to use silicone wristbands to monitor personal exposure to OPEs and determine if exposure was associated with commute time in a subset of these students. Participants were asked to wear wristbands for five continuous days and complete daily surveys about the amount of time spent commuting. Data were then used to calculate a participant-specific total commute score. Components of Firemaster 550 (triphenyl phosphate, or TPHP, and isopropylated triaryl phosphate isomers) and Firemaster 600 (TPHP and tert-butylated triaryl phosphate isomers) - both widely used commercial flame retardant formulations - were strongly correlated with other OPEs detected within participant wristbands. Moreover, the concentration of tris(1,3-dichloro-2-propyl) phosphate (TDCIPP) was significantly correlated with the concentration of several Firemaster 500 components and tris(2-chloroisopropyl) phosphate (TCIPP). Finally, out of all OPEs measured, TDCIPP was significantly and positively correlated with total commute score, indicating that longer commutes are associated with increased human exposure to TDCIPP. Overall, our findings raise concerns about the potential for chronic TDCIPP exposure within vehicles and other forms of transportation, particularly within densely populated and traffic-congested areas such as Southern California.


Asunto(s)
Exposición a Riesgos Ambientales , Retardadores de Llama , Fosfatos , Transportes , Adolescente , Adulto , Polvo , Monitoreo del Ambiente , Ésteres , Retardadores de Llama/análisis , Retardadores de Llama/toxicidad , Humanos , Persona de Mediana Edad , Organofosfatos , Adulto Joven
19.
Environ Pollut ; 244: 469-476, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30366294

RESUMEN

We have developed a method for measuring fluxes of PCBs from natural waters using air and water passive samplers deployed simultaneously in the Indiana Harbor and Ship Canal (IHSC). Net volatilization of Æ©PCBs was determined for 2017, and ranged from 1.4 to 2.8 µg m-2 d-1, with a median of 2.0 µg m-2 d-1. We confirm earlier findings that the IHSC experiences constant release of gas-phase PCBs. Gas-phase and freely-dissolved water Æ©PCB samples median were 4.0 ng m-3 and 14 ng L-1, both exhibiting increasing concentrations over the year of study, and with a strong positive correlation between them (R2 = 0.93 for Æ©PCBs). The relative concentrations of individual PCB congeners were very similar between air and water samples, and resemble Aroclor 1248, a mixture previously reported to contaminate the IHSC sediments. Monthly variability of the volatilization fluxes was primarily driven by the freely-dissolved water concentration changes (R2 = 0.87). Although different sampling methods were performed to estimate air-water fluxes between the month of August of 2006 and 2017, Æ©PCB net fluxes have decreased by more than 60%, suggesting that either dredging at IHSC from 2012 to 2017 or reduction of upstream sources have decreased the freely-dissolved water concentrations of PCBs, thus reducing the air-water net volatilization in IHSC. Finally, we have shown that this passive sampling approach represents a simple and cost-effective method to assess the air-water exchange of PCBs, increase analytical sensitivity, enable measurements over time, and reduce uncertainties related to unexpected episodic events.


Asunto(s)
Contaminantes Atmosféricos/análisis , Arocloros/análisis , Monitoreo del Ambiente/métodos , Bifenilos Policlorados/análisis , Contaminantes Químicos del Agua/análisis , Indiana , Volatilización
20.
Environ Sci Process Impacts ; 20(5): 757-766, 2018 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-29611590

RESUMEN

Accurate and precise interpretation of concentrations from polyurethane passive samplers (PUF-PAS) is important as more studies show elevated concentrations of PCBs and other semivolatile air toxics in indoor air of schools and homes. If sufficiently reliable, these samplers may be used to identify local sources and human health risks. Here we report indoor air sampling rates (Rs) for polychlorinated biphenyl congeners (PCBs) predicted for a frequently used double-dome and a half-dome PUF-PAS design. Both our experimentally calibrated (1.10 ± 0.23 m3 d-1) and modeled (1.08 ± 0.04 m3 d-1) Rs for the double-dome samplers compare well with literature reports for similar rooms. We determined that variability of wind speeds throughout the room significantly (P < 0.001) effected uptake rates. We examined this effect using computational fluid dynamics modeling and 3-D sonic anemometer measurements and found the airflow dynamics to have a significant but small impact on the precision of calculated airborne concentrations. The PUF-PAS concentration measurements were within 27% and 10% of the active sampling concentration measurements for the double-dome and half-dome designs, respectively. While the half-dome samplers produced more consistent concentration measurements, we find both designs to perform well indoors.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Bifenilos Policlorados/análisis , Poliuretanos/química , Movimientos del Aire , Calibración , Monitoreo del Ambiente/instrumentación , Diseño de Equipo , Humanos , Modelos Teóricos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA