Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Arthroplasty ; 38(11): 2316-2323.e1, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37286054

RESUMEN

BACKGROUND: Total knee arthroplasties (TKAs) for patients aged ≤35 years are rare but necessary for patients who have diseases such as juvenile idiopathic arthritis, osteonecrosis, osteoarthritis, and rheumatoid arthritis. Few studies have examined the 10-year and 20-year survivorship and clinical outcomes of TKAs for young patients. METHODS: A retrospective registry review identified 185 TKAs in 119 patients aged ≤ 35 years performed between 1985 and 2010 at a single institution. The primary outcome was implant survivorship free of revision. Patient-reported outcomes were assessed at 2 time points: 2011 to 2012 and 2018 to 2019. The average age was 26 years (range, 12 to 35). Mean follow-up was 17 years (range, 8 to 33). RESULTS: Survivorship decreased from 84% (95% confidence interval [CI]: 79 to 90) at 5 years to 70% (95% CI: 64 to 77) at 10 years and to 37% (95% CI: 29 to 45) at 20 years. The most common reasons for revision were aseptic loosening (6%) and infection (4%). Risk factors for revision included increasing age at time of surgery (Hazards Ratio [HR] 1.3, P = .01) and use of constrained (HR 1.7, P = .05) or hinged prostheses (HR 4.3, P = .02). There were 86% of patients reporting that their surgery resulted in "a great improvement" or better. CONCLUSION: Survivorship of TKAs in young patients is less favorable than expected. However, for the patients who responded to our surveys, TKA demonstrated substantial pain relief and improvement in function at 17-year follow-up. Revision risk increased with older age and higher levels of constraint.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Adulto , Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Estudios Retrospectivos , Supervivencia , Falla de Prótesis , Resultado del Tratamiento , Reoperación , Articulación de la Rodilla/cirugía , Diseño de Prótesis
2.
Artículo en Inglés | MEDLINE | ID: mdl-37400671

RESUMEN

Guideline-based surgical cartilage therapy for focal cartilage damage offers highly effective possibilities to sustainably reduce patients' complaints and to prevent or at least delay the development of early osteoarthritis. In the knee joint, it has the potential to reduce almost a quarter of the arthroses requiring joint replacement caused by cartilage damage. Biologically effective injection therapies could further improve these results. Based on the currently available literature and preclinical studies, intra- and postoperative injectables may have a positive effect of platelet-rich plasma/fibrin (PRP/PRF) and hyaluronic acid (HA) on cartilage regeneration and, in the case of HA injections, also on the clinical outcome can be assumed. The role of a combination therapy with use of intra-articular corticosteroids is lacking in the absence of adequate study data and cannot be defined yet. With regard to adipose tissue-based cell therapy, the current scientific data do not yet justify any recommendation for its use. Further studies also regarding application intervals, timing and differences in different joints are required.

3.
J Orthop Traumatol ; 24(1): 44, 2023 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-37592170

RESUMEN

BACKGROUND: The Oxford Knee Score (OKS) has been designed for patients with knee osteoarthritis and has a widespread use. It has 12 questions, with each question having the same weight for the overall score. Some authors have observed a significant ceiling effect, especially when distinguishing slight postoperative differences. We hypothesized that each questions' weight will depend significantly on the patient's sociodemographic data and lifestyle. METHODS: In this international multicentric prospective study, we included patients attending a specialist outpatient knee clinic. Each patient filled out 3 questionnaires: (a) demographic data and data pertaining to the OKS, (b) the standard OKS, and (c) the patient gave a mark on the weight of the importance of each question, using a 5-point Likert scale (G OKS). Linear regression models were used for the analysis. RESULTS: In total 203 patients (106 female and 97 male) with a mean age of 64.5 (±12.7) years and a mean body mass index (BMI) of 29.34 (±5.45) kg/m2 were included. The most important questions for the patients were the questions for pain, washing, night pain, stability, and walking stairs with a median of 5. In the regression models, age, gender, and driving ability were the most important factors for the weight of each of the question. CONCLUSION: The questions in the OKS differ significantly in weight for each patient, based on sociodemographic data, such as age, self-use of a car, and employment. With these differences, the Oxford Knee Score might be limited as an outcome measure. Adjustment of the OKS that incorporates the demographic differences into the final score might be useful if the ceiling effect is to be mitigated. LEVEL OF EVIDENCE: Level II prospective prognostic study.


Asunto(s)
Empleo , Osteoartritis de la Rodilla , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Articulación de la Rodilla , Osteoartritis de la Rodilla/cirugía , Dolor
4.
J Arthroplasty ; 37(6S): S306-S312, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35210149

RESUMEN

BACKGROUND: Antimicrobial resistance is recognized as a major public health threat. It occurs naturally; however, an excessive antibiotic use and misuse of antibiotics accelerate the process. Periprosthetic joint infections (PJI) are becoming harder to treat as the efficacy of antibiotics is becoming lower. The aim of this study was to compare the resistance of coagulase-negative staphylococci (CNS) to antibiotics identified after revision TKAs for PJI between two major orthopedic centers. METHODS: A review of all revision TKAs, undertaken between 2006 and 2018 in two orthopedic centers, was performed, including all those meeting the consensus criteria for PJI, in which CNS were identified. There were no major differences in surgical approach and tissue sampling between both centers. Thirteen commonly used antibiotics were tested at both centers. RESULTS: The 132 strains were analyzed for their resistance to 13 different antibiotics. Staphylococcus epidermidis was identified in 70.5% cultures, followed by Staphylococcus capitis in 8.3% cultures. The comparison of antibiotic resistance between two centers was statistically significant to penicillin (P = .001), oxacillin (P = .011), cefuroxime (P = .044), levofloxacin (P = .006), moxifloxacin (P = .008), tetracycline (P < .001), rifampicin (P < .001) and vancomycin (P < .001). The difference of resistance of CNS was not statistically significant to fosfomycin, clindamycin, teicoplanin, erythromycin and ampicillin. CONCLUSIONS: The resistance of CNS to antibiotics differs significantly between two major orthopedic centers that are geographically fairly close. Monitoring of bacteriological analyses in each referral center should be continuously performed. Close monitoring is needed for more efficient antibiotic treatment of and prophylaxis against PJI.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Coagulasa/uso terapéutico , Farmacorresistencia Bacteriana , Humanos , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Staphylococcus
5.
Clin Orthop Relat Res ; 478(9): 1990-2000, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32168072

RESUMEN

BACKGROUND: Unexplained pain in the medial proximal tibia frequently leads to revision after unicondylar knee arthroplasty (UKA). As one of the most important factors for osteogenic adaptive response, increased bone strain following UKA has been suggested as a possible cause. QUESTIONS/PURPOSES: In this study we: (1) performed a cadaver-based kinematic analysis on paired cadaveric specimens before and after mobile-bearing and fixed-bearing UKA; and (2) simultaneously characterized the strain distribution in the anterior and posterior proximal tibia during squatting. METHODS: Five pairs of fresh, frozen full-leg cadaver specimens (four male, one female, 64 years to 87 years) were subjected to a dynamic squatting motion on a kinematic rig to simulate joint loading for a large ROM. Forces were applied to the quadriceps and hamstrings during the simulation while an infrared camera system tracked the location of reflective markers attached to the tibia and femur. Tibial cortical bone strain was measured with stacked strain gauge rosettes attached at predefined anterior and posterior positions on the medial cortex. Pairwise implantation of mobile-bearing (UKAMB) and fixed-bearing implants (UKAFB) allowed a direct comparison of right and left knees from the same donor through a linear mixed model. RESULTS: UKAMB more closely replicated native kinematics in terms of tibial rotation and in AP and mediolateral translation. Maximum principal bone strain values were consistently increased compared with native (anteromedial, mean [± SD] peak strain: 311 µÎµ ± 190 and posterior, mean peak strain: 321 µÎµ ± 147) with both designs in the anteromedial (UKAFB, mean peak strain: 551 µÎµ ± 381, Cohen's d effect size 1.3 and UKAMB, mean peak strain: 596 µÎµ ± 564, Cohen's d effect size 1.5) and posterior (UKAFB, mean peak strain: 505 µÎµ ± 511, Cohen's d effect size 1.3 and UKAMB, mean peak strain: 633 µÎµ ± 424, Cohen's d effect size 2.1) region. However, in the anterolateral region of the medial tibial bone, UKAFB demonstrated the overall largest increase in strain (mean peak strain: 1010 µÎµ ± 787, Cohen's d effect size 1.9), while UKAMB (613 µÎµ ± 395, Cohen's d effect size 0.2) closely replicated values of the native knee (563 µÎµ ± 234). CONCLUSION: In this in vitro cadaver study both UKAMB and UKAFB led to an increase in bone strain in comparison with the native knee. However, in the anterolateral region of the medial tibial plateau, proximal tibial bone strain was lower after UKAMB and UKAFB. Both UKAMB and UKAFB lead to comparable increases in anteromedial and posterior tibial strain in comparison with the native knee. In the anterolateral region of the medial tibial plateau UKA, proximal tibial bone strain was closer to the native knee after UKAMB than after UKAFB. In an attempt to link kinematics and strain behavior of these designs there seemed to be no obvious relation. CLINICAL RELEVANCE: Further clinical research may be able to discern whether the observed differences in cortical strain after UKA is associated with unexplained pain in patients and whether the observed differences in cortical bone strain between mobile-bearing and fixed unicondylar designs results in a further difference in unexplained pain.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Complicaciones Posoperatorias/cirugía , Reoperación/métodos , Esguinces y Distensiones/cirugía , Tibia/lesiones , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Rodilla/fisiopatología , Rodilla/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Rango del Movimiento Articular , Esguinces y Distensiones/etiología , Esguinces y Distensiones/fisiopatología , Tibia/fisiopatología
6.
Surg Technol Int ; 37: 377-384, 2020 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-33137840

RESUMEN

INTRODUCTION: Major gastrointestinal complications after arthroplasty are rare, but can have detrimental effects on the patient and can substantially increase the overall cost of treatment. This systematic review provides an overview of ileus, gastrointestinal bleeding and C. difficile colitis after total hip and knee arthroplasty. MATERIALS AND METHODS: We followed the PRISMA guidelines and searched 3 databases for the period between 1 January 2000 and 31 December 2018. The manual search included references in retrieved articles. We extracted data on the cohort size, study level, arthroplasty procedure, complications and their incidence, and recommendations by the study. RESULTS: Twenty-five studies that analyzed these complications after total knee arthroplasty (TKA) and total hip arthroplasty (THA) were identified. These complications have an incidence of up to 2% each. According to some of the studies, an incidence of 0% is possible. While the risk factors for ileus varied greatly, those for C. difficile colitis were more consistent. There are some recommendations for reducing the incidence of ileus and C. difficile. This heterogeneity does not allow us to draw any conclusion regarding which thromboprophylaxis agent has the lowest incidence of gastrointestinal bleeding. CONCLUSION: The complications investigated in this systematic review are rare and have a reported incidence of up to 2% each. Even though there are some recommendations for reducing the complication rate, due to the complex nature of the arthroplasty setting, there is a need for further investigation of these risk factors and how they can be reduced.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Clostridioides difficile , Colitis , Ileus , Tromboembolia Venosa , Anticoagulantes , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/etiología , Humanos , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo
7.
Int Orthop ; 44(12): 2683-2690, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32865609

RESUMEN

PURPOSE: The goal of this study was the assessment of long-term outcome of dorsal capsular imbrication of the distal radioulnar joint (DRUJ) in dorsal instability. METHODS: The study included ten patients (mean 38.7 years of age) with a mean follow-up time of 11.2 years (9.3 years to 14.3 years). Examination parameters included Disabilities of Arm, Shoulder, and Hand (DASH) questionnaire, modified Mayo Wrist Score (MMWS), determination of range of motion in comparison with the healthy extremity, pre- and post-operative pain level assessment, and examination of DRUJ stability. RESULTS: Eight of ten DRUJs proved to be stable after the above-mentioned follow-up. Mean MMWS was 92.5 (65-100; SD: 11.1). Mean DASH Score was 8.8 (0-60; SD: 18.4). Grip strength reached 93.5% of the contralateral unaffected hand. Range of motion did not differ significantly in comparison with the healthy contralateral extremity. Nine of ten patients regarded pain level reduction as excellent. Eight of ten patients regarded DRUJ stability as excellent after surgery. CONCLUSION: Dorsal capsular imbrication of the DRUJ is an efficacious surgical technique for post-traumatic dorsal instability in the long-term.


Asunto(s)
Inestabilidad de la Articulación , Traumatismos de la Muñeca , Humanos , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular , Resultado del Tratamiento , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/cirugía
8.
Arch Orthop Trauma Surg ; 140(11): 1819-1824, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32748043

RESUMEN

INTRODUCTION: Tibial component design and positioning contribute more to patient satisfaction than previously realized. A surgeon needs to decide on the size and rotation, bearing in mind that coverage should be as high as possible, whilst malrotation and overhang should be avoided. No study investigates the impact of each of these components on clinical outcomes in a single cohort. MATERIALS AND METHODS: This is a retrospective analysis of 1-year postoperative outcomes measured with the Knee Injury and Osteoarthritis Outcome (KOOS) Score, as well as a previously validated rotational CT protocol. Coverage, rotation from Insall's axis, and overhang of an asymmetric tibial baseplate were measured, and positive and negative correlations to clinical outcomes were calculated. RESULTS: A total of 499 knees were analyzed. Patient average age was 68.4 years. Rotation within 7° internal and 5° external from Insall's axis was a "safe zone". Mean coverage was 76%. A total of 429 knees (94%) had a coverage of at least 70% and 102 knees (22%) greater than 80%. Overhang was detected in 23% of the cohort. Increased coverage was correlated to increased KOOS score and overhang correlated with a decreased KOOS score (p = 0.008). CONCLUSIONS: This study demonstrates the individual role of three aspects of tibial component implantation properties in postoperative pain and short-term functional outcomes. Upsizing to the point of overhang with rotational tolerance of 7° internal and 3° external to Insall's axis demonstrates best patient reported outcomes. Overhang decreases the clinical outcome by the same margin as loss of 16% of coverage.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Tibia , Anciano , Humanos , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/cirugía , Estudios Retrospectivos , Rotación , Tibia/fisiología , Tibia/cirugía , Resultado del Tratamiento
9.
Int J Colorectal Dis ; 34(2): 261-267, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30386890

RESUMEN

PURPOSE: Postoperative ileus (POI) is one of the complications that can occur after every surgical procedure including arthroplasty. It can have detrimental consequences for the patient and portrays an economic burden on health care systems. The risk factors for POI after arthroplasty described in the literature are scarce and include hip arthroplasty, male gender and previous abdominal surgery. The purpose of the study was to determine the risk factors for POI after hip and knee arthroplasty. METHODS: A retrospective review of 2760 patients undergoing primary hip and knee arthroplasty was performed. An in-depth analysis of patient history and physical operative and postoperative course was reviewed and statistically analyzed in a univariate and multivariate setting. RESULTS: Overall incidence of POI was 0.54%. History of myocardial infarction and chronic kidney disease were statistically significant risk factors for developing POI after arthroplasty with values of p = 0.023 and p = 0.004, respectively. Other risk factors included previous abdominal surgery (p < 0.001) and hip arthroplasty (p = 0.026). Age or gender correlations were not observed. CONCLUSIONS: Although postoperative ileus is an uncommon complication after joint arthroplasty, in addition to the known risk factors of male age, hip arthroplasty, and previous abdominal surgery, this study describes two previously unknown risk factors: chronic kidney disease and history of myocardial infarction. Patients with these risk factors should be monitored closely for developing postoperative ileus.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Ileus/etiología , Análisis Factorial , Femenino , Humanos , Ileus/epidemiología , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Factores de Riesgo
10.
Clin Orthop Relat Res ; 477(9): 2007-2014, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30811355

RESUMEN

BACKGROUND: Elevated serum levels of chromium and cobalt ions in metal-on-metal (MoM) bearing surfaces is a well-known phenomenon in THA. However, few studies have addressed this issue in complex primary and revision knee arthroplasty using a MoM hinged mechanism, and no study, to our knowledge, has investigated knees with MoM hinges in patients without megaprostheses (tumor prostheses). QUESTIONS/PURPOSES: We analyzed a series of patients who received MoM hinged revision knee prostheses and asked: (1) What are the serum metal ion levels at short-term followup? (2) Is there any correlation between metal ion levels and the Knee Society Score (KSS) at this followup? METHODS: Between 2013 and 2017, we performed 198 revision knee arthroplasties, of which 32 (17.7%) were performed with a latest-generation MoM hinge knee design. In addition, three complex primary TKAs utilizing the same design were included in this study. The device features a metal-on-polyethylene bearing with a MoM hinge. During that period, our general indications for using a hinge were single-stage and two-stage revision surgeries, revisions with large bone defects, and primary TKA with > 20° mechanical malalignment or collateral ligament insufficiency. Of the 35 patients who received this device, 23 patients (65% of the overall group who received this implant; 11 males, 12 females) were available for followup at a median of 28 months (range, 13-61 months), and the remaining 12 (35%) patients were lost to followup. Our rationale for reporting before the more typical 2-year minimum was the finding of elevated serum ion levels with unclear clinical significance. Median age at the time of surgery was 68 years (range, 52-84 years). None of the patients included in the study had other implants with MoM bearings. Serum ion levels of chromium (III) and cobalt were assessed using mass spectrometry. Ion levels > 5 ppb were considered elevated. Clinical outcome was assessed using the original KSS. RESULTS: Median chromium serum level was 6.3 ppb (range, 0.6-31.9 ppb) and median cobalt serum level was 10.5 (range, 1.0-47.5 ppb). Of the 23 patients, 16 had elevated serum ion levels. There was a moderate correlation between KSS and both chromium (p = 0.029, r = 0.445) and cobalt (p = 0.012, r = 0.502) levels. CONCLUSIONS: Elevated metal ion levels and radiolucent lines are common after surgery with this MoM hinge design at short-term followup, and we believe this finding is of great concern. Although no patient has yet been revised, these patients will be closely monitored. We recommend that serum ion analysis become a routine part of followup after any hinge TKA in an attempt to better understand the potential consequences of this phenomenon. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Asunto(s)
Cromo/sangre , Cobalto/sangre , Iones/sangre , Prótesis de la Rodilla/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Cuidados Posteriores , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Factores de Tiempo , Resultado del Tratamiento
11.
BMC Musculoskelet Disord ; 20(1): 77, 2019 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-30764879

RESUMEN

BACKGROUND: The direct anterior approach (DAA) has gained popularity in total hip arthroplasty (THA) over the past decade. A large number of studies have compared the DAA to other approaches with inclusion of a learning curve phase. The aim of this study was to compare the complication rate and bleeding between the DAA and the anterolateral approach after the learning curve phase. METHODS: For this retrospective, single-institutional study, propensity score matching was performed, from an initial cohort of 1408 patients receiving an elective THA. Two matching groups were created, comprising of 396 patients each. After matching, both groups were similar in age, gender, body mass index, anesthesiologist's score and surgeon's experience. RESULTS: Average age in the matched groups was 68.7 ± 10.3 years. The total blood loss was similar in both groups, 450 vs 469 mL (p = 0.400), whereas the transfusion rate (14.1 vs 5.8%, p < 0.001) and the overall complication rate (17.6 vs 12.1%, p = 0.018) were lower in the DAA group. The overall fracture rate was comparable, 1.5 vs 1% (p = 0.376), as well as the early infection rate, 0.3 vs 1% (p = 0.162). The dislocation rate was significantly increased in the DAA group, 2.2 vs 0.5% (p = 0.032). CONCLUSIONS: The direct anterior approach has comparable short-term surgical complications with reduced transfusion and general complication rates. LEVEL OF EVIDENCE: Level III retrospective study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Pérdida de Sangre Quirúrgica , Articulación de la Cadera/cirugía , Complicaciones Posoperatorias/etiología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Femenino , Alemania , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Análisis por Apareamiento , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Int Orthop ; 43(3): 653-658, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30076444

RESUMEN

PURPOSE: In this study, the total blood loss, transfusion rate and number of transfused blood units in patients with different indications for shoulder arthroplasty: primary, fracture and secondary were compared. Risk factors for bleeding and transfusion were analysed. METHODS: Medical records and the database of the institution's blood bank from 527 patients that received shoulder arthroplasty were analysed retrospectively. This study included 419 patients that were divided in three different groups: primary (n = 278), fracture (n = 110) and secondary (following prior osteosynthesis; n = 31) shoulder arthroplasty. The demographic and clinical data were collected. The total blood loss (TBL) was calculated and transfusions recorded. RESULTS: The transfusion rate and mean amount of transfused blood units (BU) were higher in fracture (32.7% and 0.69BU, p < 0.01) and secondary arthroplasty (35.5% and 0.97BU, p < 0.01) than in primary arthroplasty (12.6% and 0.28BU). The overall transfusion rate was 19.6% at a mean TBL of 370 ml. However, patients with primary arthroplasty experienced significantly higher total blood loss than those after fracture arthroplasty (p < 0.01). Longer surgery time and male sex are significant risk factors for elevated blood loss. The pre-operative use of vitamin K antagonist, cemented arthroplasty, high BMI, coronary heart disease and ASA score > 2 are relevant risk factors for blood transfusion. CONCLUSION: The most important susceptible factor that affects the TBL is the surgery time. Transfusion rates are higher in patients with fracture arthroplasty than after primary arthroplasty.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Pérdida de Sangre Quirúrgica , Transfusión Sanguínea , Artropatías/cirugía , Hemorragia Posoperatoria , Articulación del Hombro/cirugía , Anciano , Artroplastía de Reemplazo de Hombro/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo
13.
Arch Orthop Trauma Surg ; 139(8): 1045-1049, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30770995

RESUMEN

INTRODUCTION: Impingement of the prominent anterior inferior iliac spine (AIIS) against the femoral neck has recently been described as another type of impingement. The purpose of this study is to provide a distribution of AIIS types using the classification proposed by Hetsroni and thus report on the prevalence of prominent types. MATERIALS AND METHODS: A total of 400 patients were included in the study with an average age 27.3 ± 6.9 years (range 18-40). All patients received a whole-body polytrauma computer tomography (CT) scan in the emergency room (ER) upon arrival. The classification of AIIS proposed by Hetsroni et al., which describes three morphological types, was used. Type II and III were grouped as prominent types. The measurements were performed in all three planes by two examiners. RESULTS: Male to female ratio was 71:29. Type I was observed in 367 (91.7%) patients. Type II was observed in 31 (7.8%) patients and type III was observed in 2 (0.5%) patients, unilaterally. Prominent types were much more prevalent in men (10.5%) than in women (2.6%). The CT assessment demonstrated excellent intra- and interreliability (overall: 0.926, I/II: 0.906, III: 1.000). CONCLUSION: A young population demonstrates a prevalence of a prominent AIIS of 11.5%. Prominent AIIS is more common in men than in women.


Asunto(s)
Artralgia/fisiopatología , Cuello Femoral/fisiopatología , Ilion/fisiopatología , Artropatías/fisiopatología , Adolescente , Adulto , Femenino , Cuello Femoral/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Ilion/diagnóstico por imagen , Imagenología Tridimensional , Artropatías/clasificación , Artropatías/diagnóstico por imagen , Masculino , Prevalencia , Factores Sexuales , Tomografía Computarizada por Rayos X , Imagen de Cuerpo Entero , Adulto Joven
14.
Arch Orthop Trauma Surg ; 139(1): 73-78, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30039308

RESUMEN

INTRODUCTION: Although there is increasing evidence for the successful use of local vancomycin applied by soaked compresses during ACL reconstruction, there are still little data on its microbiological and biomechanical effects. Furthermore, exact dosage of vancomycin with respect to tendon stability and microbiological effectivity is still unknown. MATERIALS AND METHODS: 63 porcine flexor digitorum profundus tendons were harvested under sterile conditions from fresh cadaver legs. After contamination with Staphylococcus epidermidis (S. epidermidis), tendons were wrapped into sterile compresses moistened with different concentrations of vancomycin for 10 or 20 min. Sterile sodium chloride was used for control. After treatment, tendons were rolled onto blood-agar plates to test for residual bacterial contamination and tested for maximum load and stiffness using a uniaxial testing device with cryo-clamps for tendon fixation. Agar plates were checked after 1 week of culture at 36 °C for signs of bacterial growth. RESULTS: When applying vancomycin for only 10 min, bacterial contamination was found in all dosage groups ranging from 28.6% contamination (n = 2 of 7 tendons) when using 10 mg/ml up to 85.7% (n = 6 of 7 tendons) when using 1 mg/ml. Applying vancomycin-soaked compresses for 20 min, bacterial contamination was still found in the groups using 1 mg/ml and 2.5 mg/ml (contamination rate 85.7 and 42.9% respectively). When using 5 mg/ml and 10 mg/ml, no bacterial contamination could be perceived after 7 days of culture. With regard to biomechanical properties, no differences were found regarding maximum load or Young's modulus between groups. CONCLUSIONS: This study showed no signs of biomechanical impairment of porcine flexor tendons after the use of vancomycin wraps with concentration ranging from 1 to 10 mg/ml for 10 or 20 min at a time zero testing. Contamination with S. epidermidis was cleansed in 100% of tendons when using at least 5 mg/ml of vancomycin for 20 min.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Antibacterianos/farmacología , Tendones , Vancomicina/farmacología , Animales , Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos/fisiología , Staphylococcus epidermidis/efectos de los fármacos , Porcinos , Tendones/microbiología , Tendones/fisiología , Tendones/cirugía , Tendones/trasplante
15.
Acta Orthop ; 90(5): 445-449, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31282247

RESUMEN

Background and purpose - To date, there is not a single clinical or mechanical study directly comparing a cemented and a cementless version of the same stem. We investigated the load-to-failure force of a cementless and a cemented version of a double tapered stem. Material and methods - 10 femurs from 5 human cadaveric specimens, mean age 74 years (68-79) were extracted. Bone mineral density (BMD) was measured using peripheral quantitative computed tomography. None of the specimens had a compromised quality (average T value 0.0, -1.0 to 1.4). Each specimen from a pair randomly received a cemented or a cementless version of the same stem. A material testing machine was used for lateral load-to-failure test of up to a maximal load of 5.0 kN. Results - Average load-to-failure of the cemented stem was 2.8 kN (2.3-3.2) and 2.2 kN (1.8-2.8) for the cementless stem (p = 0.002). The cemented version of the stem sustained a higher load than its cementless counterpart in all cases. Failure force was not statistically significantly correlated to BMD (p = 0.07). Interpretation - Implanting a cemented version of the stem increases the load-to-failure force by 25%.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Cementación , Fracturas del Fémur/etiología , Prótesis de Cadera , Fracturas Periprotésicas/etiología , Falla de Prótesis/etiología , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementos para Huesos , Densidad Ósea/fisiología , Cadáver , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/fisiopatología , Fémur/fisiopatología , Humanos , Masculino , Ensayo de Materiales/métodos , Fracturas Periprotésicas/diagnóstico por imagen , Fracturas Periprotésicas/fisiopatología , Diseño de Prótesis , Estrés Mecánico , Tomografía Computarizada por Rayos X , Soporte de Peso/fisiología
16.
BMC Musculoskelet Disord ; 19(1): 8, 2018 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-29316902

RESUMEN

BACKGROUND: Ankle tape is widely used by athletes to prevent ankle sprain. Although there is growing evidence that ankle tape improve joint position sense, but yet it is not clear even if tape improve joint position sense after muscle fatigue, because fatigue impair joint position sense and raise the risk of ankle sprain. The aim of this study is to examine the effect of ankle tape on joint position sense after local muscle fatigue. METHOD: This trial is a randomized controlled trial. 34 healthy subjects participated in this trial. Subjects were randomized distributed into two groups: with tape and without tape. Active and passive absolute error and variable error mean values for two target positions of the ankle joint (15° inversions and inversion minus 5°) before and after fatigue protocol consisted of 30 consecutive maximal concentric/concentric contractions of the ankle evertors and invertors. In this trail joint position sense for all subjects was assessed using The Biodex System isokinetic dynamometer 3, this system is used also for fatigue protocol. RESULTS: For the variable error (VE), significant mean effect was found for active joint position sense in 15° of inversion after muscle fatigue (P < 0, 05). It was a significant decrease in the work in the last third of inversion detected (P < 0, 05). There was no significant main effect found for fatigue index of eversion. CONCLUSION: Ankle tape can improve joint position sense at the fatigue session when joint position sense becomes worse. As a result, ankle tape may be useful to prevent ankle sprain during playing sports. We suggest athletes and individuals at risk of ankle sprain to apply taping before high-load activity. TRIAL REGISTRATION: The study was retrospectively registered on the ISRCTN registry with study ID ISRCTN30042335 on 12th December 2017.


Asunto(s)
Articulación del Tobillo/fisiología , Cinta Atlética/estadística & datos numéricos , Fatiga Muscular/fisiología , Propiocepción/fisiología , Adulto , Traumatismos del Tobillo/fisiopatología , Traumatismos del Tobillo/prevención & control , Femenino , Humanos , Masculino , Resultado del Tratamiento
17.
BMC Musculoskelet Disord ; 19(1): 9, 2018 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-29316907

RESUMEN

BACKGROUND: Chondrosarcoma is the second most common primary malignant bone tumor. Because of their heterogeneity, with differences in invasive and metastatic behavior, it is important to identify biological markers that will allow for a more accurate estimation of prognosis in patients with these tumors. Matrix metalloproteinases (MMP) play a crucial role in tumor progression, invasion and metastasis. The mechanism of tumor progression dependent of MMPs is complex and influences malignant transformation, angiogenesis and tumor growth at the primary and metastatic sites. The purpose of this study was to investigate immunohistochemicaly the influence of MMP-1, MMP-3, MMP-9 and MMP-13 expression on prognostic parameter in chondrosarcoma. METHODS: We investigated tissue samples of 28 patients with chondrosarcoma. Immunohistochemical staining to evaluate the expression of MMP-1, MMP-3, MMP-9 and MMP-13 was performed. Subsequently, the expression level was correlated with metastatic potential, histological grading and overall survival in patients with this neoplasm. RESULTS: In consideration of semi quantitative scoring 64% of chondrosarcoma were scored as positive for MMP-1, 46% for MMP-3, 61% for MMP-9. The specimens had shown no expression of MMP-13. High expression of MMP-9 was associated with better histological differentiation, decreased metastatic potential and favourable overall survival. No correlation was found for expression of MMP-1, MMP-3 or MMP-13. CONCLUSIONS: MMP-1, MMP-3 and MMP-9 are expressed in chondrosarcoma. Our findings suggest that the expression of MMP-9 is associated with clinical outcome parameters in chondrosarcoma.


Asunto(s)
Biomarcadores de Tumor/biosíntesis , Neoplasias Óseas/enzimología , Condrosarcoma/enzimología , Regulación Enzimológica de la Expresión Génica , Metaloproteinasa 9 de la Matriz/biosíntesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/genética , Neoplasias Óseas/diagnóstico , Neoplasias Óseas/mortalidad , Condrosarcoma/diagnóstico , Condrosarcoma/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Inmunohistoquímica , Masculino , Metaloproteinasa 9 de la Matriz/análisis , Metaloproteinasa 9 de la Matriz/genética , Persona de Mediana Edad , Adulto Joven
18.
Eur J Anaesthesiol ; 35(10): 782-791, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29794563

RESUMEN

BACKGROUND: Combining continuous femoral nerve blockade with single injection sciatic nerve blockade is standard peripheral nerve block practice for total knee arthroplasty (TKA) during the first 24 postoperative hours. OBJECTIVES: To assess the analgesic benefits and mobilisation capability of continuous sciatic blockade in conjunction with continuous femoral nerve blockade for 72 h after arthroplasty. DESIGN: Randomised, triple-blinded controlled trial. SETTING: Single-Centre, German University Hospital. PATIENTS: In total, 50 patients receiving continuous femoral nerve blockade (5 ml h ropivacaine 0.2%) for TKA under general anaesthesia. INTERVENTIONS: Patients were randomised to receive a sciatic nerve catheter with an initial dose of 10 ml ropivacaine 0.2% followed by either continuous double-blinded application of 5 ml h ropivacaine 0.2% (CO) or 5 ml h saline infusion (SIN). MAIN OUTCOME: Measures primary endpoint: cumulative morphine consumption until 48 h postoperatively. Further endpoints included morphine consumption, pain scores, mobilisation, dynamometry until postoperative day 3. RESULTS: Median [25th to 75th percentiles] cumulative morphine consumption at postoperative day 2 differed significantly between groups (CO 15 mg [11 to 25] versus SIN, 43 mg [27 to 67.5, P < 0.0001) in the 48 patients in the final analysis. Overall pain scores were comparable at rest and during stress at each time point. However, significantly higher pain scores of the popliteal fossa were observed in the SIN group. Mobilisation was comparable between groups. CONCLUSION: This trial demonstrates the superior analgesic effects of continuous sciatic nerve block compared with a single injection in combination with continuous femoral blockade during the first 72 h after TKA. However, mobilisation capability was impaired in both groups. Improved pain control from two catheters needs to be balanced against the potential risks of impaired mobilisation and patient falls. TRIAL REGISTRATION: DRKS - German clinical trials register (no: DRKS00010152).


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Bloqueo Nervioso Autónomo/métodos , Manejo del Dolor/métodos , Dolor Postoperatorio/diagnóstico por imagen , Nervio Ciático/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Anciano , Artroplastia de Reemplazo de Rodilla/normas , Bloqueo Nervioso Autónomo/normas , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Manejo del Dolor/normas , Dolor Postoperatorio/prevención & control , Nervio Ciático/efectos de los fármacos , Ultrasonografía Intervencional/normas
19.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1767-1775, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29128876

RESUMEN

PURPOSE: Femoral component malrotation in total knee arthroplasty (TKA) is clinically proven to cause dissatisfaction and impaired function. This study is an attempt to characterize the tibiofemoral kinematics following femoral malrotation in posterior stabilized (PS) TKA. It was hypothesized that internal malrotation would introduce the most pronounced changes. METHODS: Six fresh-frozen cadaver specimens were mounted in a kinematic rig. Three motion patterns were applied with the native knee and following PS TKA (passive motion, open chain extension, and squatting) while infrared cameras recorded the trajectories of markers attached to femur and tibia. Three different femoral implants were tested: a conventional posterior stabilized component, and adapted components of the same implant with 5° of intrinsic external and internal rotation, respectively. RESULTS: The implantation of the PS TKA resulted in less tibial internal rotation (squat 33-70°, p < 0.05) and the medial femoral condyle shifted posteriorly especially in deep flexion (squat 84-111°, p < 0.05). Internal component malrotation caused internal rotation and abduction of the tibia in flexion (squat 33-111°, p < 0.05), an elevated (squat 43-111°, p < 0.05) and more anterior (passive 61-126°, p < 0.05) located medial femoral condyle and a lateral femoral condyle located more posterior and inferior (squat 73-111°, p < 0.05) than in the neutrally aligned TKA. External component malrotation caused only little changes under passive motion. Under a squat there was less internal rotation and more adduction to the tibia (33-111°, p < 0.05). The medial femoral condyle was moved more posterior (squat 59-97°, p < 0.05), the lateral femoral condyle more superior (squat 54-105°, p < 0.05) than in the neutrally aligned TKA. CONCLUSION: The greatest differences to the native tibiofemoral kinematics were introduced by internal rotation of the femoral component. Also neutrally and externally rotated femoral components introduce kinematic changes, but to a lesser extent. With respect to the alterations introduced to kinematics internal malrotation should be avoided when performing PS TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Desviación Ósea/fisiopatología , Fémur/cirugía , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla/efectos adversos , Tibia/fisiopatología , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Desviación Ósea/cirugía , Cadáver , Fémur/fisiopatología , Humanos , Articulación de la Rodilla/cirugía , Masculino , Rango del Movimiento Articular , Rotación , Tibia/cirugía
20.
Arch Orthop Trauma Surg ; 138(9): 1317-1322, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30043147

RESUMEN

INTRODUCTION: This stem was cleared by the FDA in 2002 and has been implanted in cementless and cemented versions. Despite its long history, there are no long-term clinical  results available for the cemented version of this implant. The aim of this study was to provide such data. It was hypothesized that this implant delivers clinical success comparable to other tapered cemented stems. MATERIALS AND METHODS: A total of 113 hip replacements were performed in 106 patients between October 2007 and December 2009 using the cemented version of this stem. The mean age of the patients at operation was 74.8 years (range 50-91 years). The mean follow-up was 8.9 years with only two patients lost to follow-up. Implant survival was determined using the Kaplan-Meier analysis. RESULTS: Stem survival with revision for any reason as the endpoint was 96.4% after 10 years. Survival for stem aseptic loosening was 100%. There were no cases of osteolysis. Clinical outcomes, as shown by Harris Hip Scores, were in line with previous investigations and the rate of adverse events was very low. CONCLUSIONS: This is a modern cemented stem with an excellent survival rate and satisfactory functional outcomes. In this cohort, there were no failures related to the stem through the first decade.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos/uso terapéutico , Prótesis de Cadera/efectos adversos , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos/efectos adversos , Femenino , Estudios de Seguimiento , Articulación de la Cadera/cirugía , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis/efectos adversos , Falla de Prótesis/etiología , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA