Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(10): 2029-2039, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37681996

RESUMEN

INTRODUCTION: Cryoballoon ablation (CBA) aiming at pulmonary vein isolation (PVI) became a standardized atrial fibrillation (AF) ablation procedure. Life-threatening complications like cardiac tamponade exist. Intracardiac echocardiography (ICE) usage is associated with superior safety in radiofrequency ablation. It is unclear if ICE has an impact on safety of CBA. METHODS: The FREEZE Cohort (NCT01360008) subanalysis included patients undergoing "PVI only" CBA. Patients with intraprocedural transesophageal echocardiography were excluded. Group A comprises conventional, group B ICE-guided CBA. Periprocedural results were compared. RESULTS: From 2011 to 2016, a total of 4189 patients were enrolled, and 1906 (45.5%) were included in this subanalysis, split up in two groups (A: 1066 [55.9%], B: 840 [44.1%]). Group A was younger (60.6 ± 10.8 vs. 62.4 ± 10.5 years, p < .001), with smaller left atria (41 vs. 43 mm, p < .001), and less persistent AF (23.1 vs. 38.1%, p < .001). Procedure, left atrial, and fluoroscopy times were shorter in group A as compared to group B. Dose area product was significantly higher in group A (2911 vs. 2072 cGyxcm2 , p < .001). In-hospital major adverse cerebrovascular and cardiac event rates including two deaths in group A were not different between groups (0.5% vs. 0.1%, p = .18). The rate of total procedural (10.4% vs. 5.1%, p < .001) and major complications (3.2% vs. 1.3%, p < .001) was significantly higher in group A. Cardiac tamponade occurred significantly more frequently in group A (8 [0.8%] vs. 1 [0.1%], p = .046). Independent predictors for major complications were female sex (odds ratio [OR] 2.03, p = .03) and non-ICE usage (OR 2.38, p = .02). No differences were observed for persistent phrenic nerve palsy, nor for groin complications. CONCLUSION: CBA was significantly safer and required less radiation if ICE was used, although the procedures were more complex. The risk of groin complications was not increased with ICE usage. Non-ICE usage was the only modifiable independent predictor of major complications.


Asunto(s)
Fibrilación Atrial , Taponamiento Cardíaco , Ablación por Catéter , Criocirugía , Venas Pulmonares , Femenino , Humanos , Masculino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Taponamiento Cardíaco/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios de Cohortes , Criocirugía/efectos adversos , Criocirugía/métodos , Ecocardiografía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento , Estudios Prospectivos
2.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-36624380

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Estudios de Cohortes , Criocirugía/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Electrofisiología , Resultado del Tratamiento , Recurrencia
3.
J Cardiovasc Electrophysiol ; 33(3): 483-492, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35028995

RESUMEN

BACKGROUND: Registry data add important information to randomized controlled trials (RCT) on real-life aspects of implantable cardioverter-defibrillator (ICD) patients with and without cardiac resynchronization therapy (CRT-D). This analysis of the prospectively conducted German Device Registry aims at comparing mortality rates, comorbidities, complication rates to results from RCT. METHODS: The German Device registry (DEVICE) prospectively collected data on ICD and CRT-D first implantations from 50 German centres. Demographic data, details on cardiac disease, electrocardiogram (ECG), medication, and data about procedure, complications, and hospital stay were stored in electronic case report forms. One year after device implantation patients were contacted for follow-up. RESULTS: DEVICE included n = 4384 first ICD/CRT-D implantations (29.3% CRT-D devices). We found a strong adherence to guidelines with over 90% of patients being on ß-blocker and ACE-inhibitor medication and adequate QRS width in the majority of CRT-D patients. Patients receiving a CRT-D were older (67.6 ± 11.0 years vs. 63.9 ± 13.4 years, p < .001) and had lower ejection fractions (mean 25% vs. 30%, p < .001) compared to ICD patients. Dilated cardiomyopathy was the predominant underlying heart disease in CRT-D (53.3%), coronary artery disease in ICD patients (64.7%). Compared to RCT our DEVICE patients had more comorbidities (17.9% chronic kidney disease [CKD]) and higher 1-year mortality rates (10.7% ICD group, 12.3% CRT group). In multivariate analysis, CKD patients had an almost 2-fold higher risk of 1-year mortality. CONCLUSION: Despite relevant limitations of registry data, DEVICE highlights important differences between RCT and real-world registry data and the impact of comorbidities on mortality of ICD and CRT-D recipients.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistema de Registros , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 32(4): 949-957, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33644913

RESUMEN

INTRODUCTION: The objective was to analyze the impact of patient age on clinical characteristics, procedural results, safety, and outcome of cryoballoon ablation (CBA) as the primary approach in the interventional treatment of symptomatic atrial fibrillation (AF). METHODS AND RESULTS: The single-center prospective observational study investigated consecutive patients who underwent initial left atrial ablation for symptomatic paroxysmal (PAF) or persistent AF (persAF). Age groups (A-F) of less than 40, 40-49, 50-59, 60-69, 70-79 and more than or equal to 80 years were evaluated. Follow-up (FU) included ECG, Holter monitoring and assessment of AF-symptoms. From 2012 to 2016, a total of 786 patients (64 ± 11 years, range 21-85) underwent CBA. With advancing age, more cardiovascular comorbidities and larger LA diameter were observed, more females were included (each p < .001). PAF (57%) and persAF (43%, p = .320) were equally distributed over all age groups. Age was neither related to procedural parameters, nor to the complication rate (3.9%, p = .233). Median FU was 38 months. Two non-procedure related noncardiac deaths occurred late during FU. Freedom from arrhythmia was independent of age at 18 months (p = .210) but decreased for patients more than or equal to 70 years at 24 months (p = .02). At 36 months, freedom from arrhythmia was 66%-74% (groups A-D), 54% (E) and 49% (F), respectively (p = .002). LA diameter and persAF were independent predictors, whereas age was a dependent predictor of recurrence. CONCLUSION: CBA as the primary approach in the initial ablation procedure is safe and highly effective in the young, middle aged, and elderly population. LA diameter and persAF, but not ageing, were independent predictors for arrhythmia recurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Lactante , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
5.
Eur J Nucl Med Mol Imaging ; 48(4): 1070-1080, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32970218

RESUMEN

PURPOSE: Increased angiogenesis after myocardial infarction is considered an important favorable prognostic parameter. The αvß3 integrin is a key mediator of cell-cell and cell-matrix interactions and an important molecular target for imaging of neovasculature and repair processes after MI. Thus, imaging of αvß3 expression might provide a novel biomarker for assessment of myocardial angiogenesis as a prognostic marker of left ventricular remodeling after MI. Currently, there is limited data available regarding the association of myocardial blood flow and αvß3 integrin expression after myocardial infarction in humans. METHODS: Twelve patients were examined 31 ± 14 days after MI with PET/CT using [18F]Galacto-RGD and [13N]NH3 and with cardiac MRI including late enhancement on the same day. Normal myocardium (remote) and areas of infarction (lesion) were identified on the [18F]Galacto-RGD PET/CT images by correlation with [13N]NH3 PET and cardiac MRI. Lesion/liver-, lesion/blood-, and lesion/remote ratios were calculated. Blood flow and [18F]Galacto-RGD uptake were quantified and correlated for each myocardial segment (AHA 17-segment model). RESULTS: In 5 patients, increased [18F]Galacto-RGD uptake was notable within or adjacent to the infarction areas with a lesion/remote ratio of 46% (26-83%; lesion/blood 1.15 ± 0.06; lesion/liver 0.61 ± 0.18). [18F]Galacto-RGD uptake correlated significantly with infarct size (R = 0.73; p = 0.016). Moreover, it correlated significantly with restricted blood flow for all myocardial segments (R = - 0.39; p < 0.0001) and even stronger in severely hypoperfused areas (R = - 0.75; p < 0.0001). CONCLUSION: [18F]Galacto-RGD PET/CT allows the visualization and quantification of myocardial αvß3 expression as a key player in angiogenesis in a subset of patients after MI. αvß3 expression was more pronounced in patients with larger infarcts and was generally more intense but not restricted to areas with more impaired blood flow, proving that tracer uptake was largely independent of unspecific perfusion effects. Based on these promising results, larger prospective studies are warranted to evaluate the potential of αvß3 imaging for assessment of myocardial angiogenesis and prediction of ventricular remodeling.


Asunto(s)
Integrina alfaVbeta3 , Infarto del Miocardio , Humanos , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Miocardio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Estudios Prospectivos
6.
Eur Radiol ; 31(1): 486-493, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32725337

RESUMEN

OBJECTIVES: To evaluate the long-term prognostic value of coronary CT angiography (cCTA)-derived plaque measures and clinical parameters on major adverse cardiac events (MACE) using machine learning (ML). METHODS: Datasets of 361 patients (61.9 ± 10.3 years, 65% male) with suspected coronary artery disease (CAD) who underwent cCTA were retrospectively analyzed. MACE was recorded. cCTA-derived adverse plaque features and conventional CT risk scores together with cardiovascular risk factors were provided to a ML model to predict MACE. A boosted ensemble algorithm (RUSBoost) utilizing decision trees as weak learners with repeated nested cross-validation to train and validate the model was used. Performance of the ML model was calculated using the area under the curve (AUC). RESULTS: MACE was observed in 31 patients (8.6%) after a median follow-up of 5.4 years. Discriminatory power was significantly higher for the ML model (AUC 0.96 [95%CI 0.93-0.98]) compared with conventional CT risk scores including Agatston calcium score (AUC 0.84 [95%CI 0.80-0.87]), segment involvement score (AUC 0.88 [95%CI 0.84-0.91]), and segment stenosis score (AUC 0.89 [95%CI 0.86-0.92], all p < 0.05). Similar results were shown for adverse plaque measures (AUCs 0.72-0.82, all p < 0.05) and clinical parameters including the Framingham risk score (AUCs 0.71-0.76, all p < 0.05). The ML model yielded significantly higher diagnostic performance compared with logistic regression analysis (AUC 0.96 vs. 0.92, p = 0.024). CONCLUSION: Integration of a ML model improves the long-term prediction of MACE when compared with conventional CT risk scores, adverse plaque measures, and clinical information. ML algorithms may improve the integration of patient's information to enhance risk stratification. KEY POINTS: • A machine learning (ML) model portends high discriminatory power to predict major adverse cardiac events (MACE). • ML-based risk stratification shows superior diagnostic performance for MACE prediction over coronary CT angiography (cCTA)-derived risk scores or clinical parameters alone. • A ML model outperforms conventional logistic regression analysis for the prediction of MACE.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Placa Aterosclerótica , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Aprendizaje Automático , Masculino , Placa Aterosclerótica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Tomografía Computarizada por Rayos X
7.
Europace ; 22(6): 906-915, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32361733

RESUMEN

AIMS: Symptomatic atrial arrhythmias despite complete pulmonary vein isolation (PVI) are common. The purpose was to evaluate ultra-high-density multi-electrode electroanatomical mapping-guided radiofrequency ablation (RFA) in PVI non-responders. METHODS AND RESULTS: Ultra-high-density multi-electrode electroanatomical mapping-guided RFA in consecutive symptomatic atrial fibrillation (AF) patients after initial cryoballoon PVI was performed. Patients were included if all pulmonary veins (PVs) were still isolated. Radiofrequency targets were atrial tachycardia (AT), extra-PV trigger, and/or substrate. Procedural results and outcome were evaluated. Of 95 patients, 67 (70.5%) with complete PVI were included (70 years, CHA2DS2Vasc 2.9, left atrium 45 mm, persistent AF 45%, AT 45%). The median time to reablation was 26 months. One hundred and seven maps (1.6/patient) and 11.890 ± 9.018 electrograms were acquired in 33 ± 12 min. Twenty-eight percent of the left atrial (LA) wall showed pathological voltage signals, predominantly at the anterior (37%) and septal wall (26%). Atrial tachycardia (49 left, 4 right) were ablated in 35 patients (52%), extra-PV trigger in two patients (3%). One atrioventricular nodal re-entry tachycardia and seven right atrial isthmus ablation (10%) were performed. In 32 patients (48%), no AT was present and substrate-based ablation was performed. Mean LA area ablated was 7 ± 6 cm2 (7%). No major complication occurred. The mean follow-up time was 772 ± 317 days. Freedom from atrial arrhythmia recurrence off antiarrhythmic drugs was 49% at 12 months. CONCLUSION: Pulmonary vein isolation non-responders are older, mainly suffering from complex atrial arrhythmias. Left atrial substrate is predominantly located at the anterior and septal wall. Ultra-high-density multi-electrode electroanatomical mapping-guided RFA is safe and effective. At 1 year, 5 out of 10 patients were in stable sinus rhythm off antiarrhythmic drugs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
8.
Nature ; 515(7525): 50-7, 2014 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-25373674

RESUMEN

Historically, farmers and hunter-gatherers relied directly on ecosystem services, which they both exploited and enjoyed. Urban populations still rely on ecosystems, but prioritize non-ecosystem services (socioeconomic). Population growth and densification increase the scale and change the nature of both ecosystem- and non-ecosystem-service supply and demand, weakening direct feedbacks between ecosystems and societies and potentially pushing social-ecological systems into traps that can lead to collapse. The interacting and mutually reinforcing processes of technological change, population growth and urbanization contribute to over-exploitation of ecosystems through complex feedbacks that have important implications for sustainable resource use.


Asunto(s)
Agricultura/tendencias , Conservación de los Recursos Naturales/tendencias , Ecosistema , Urbanización/tendencias , Agricultura/estadística & datos numéricos , China , Conservación de los Recursos Naturales/estadística & datos numéricos , Grano Comestible/crecimiento & desarrollo , Retroalimentación , Actividades Humanas , Modelos Económicos , Niger , Crecimiento Demográfico , Suecia , Población Urbana
9.
Environ Monit Assess ; 192(8): 520, 2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32671561

RESUMEN

Field margin vegetation (FMV) refers to the plant community in the interface between agriculture and natural environments. Substantial work has been carried out on the management of field margins in European countries with the aim of conserving field-level biodiversity and enhancing agronomic benefits. India, instead, is lagging behind in the assessment of FMV and formulating subsequent management strategies for biodiversity conservation at the field boundaries. This study is a first step to better understand the structural and functional dimensions of field margin vegetation along an agricultural transformation gradient near the megacity of Bengaluru, India. Empirical field studies along with the detection of vegetation change using remote sensing and geo-informatics technique were used to record information on field margin vegetation. The phytosociological study, revealed a total of 81 species, comprising 29 species of trees, 21 shrubs and 31 herbs at the field margins of six selected villages of northern Bengaluru. Randomly selected 355 field boundaries were delineated from high-resolution Worldview 3 images for the year 2018 and from Google Earth images for the year 2004-2005. The FMV area was around to 85.40 ha in 2004-2005 but declined to 76.69 ha in 2017-2018. The survey also indicated that local farmers have in-depth ecological knowledge on the importance of FMV in ensuring a sustainable flow of resources within the agricultural landscape. The results demonstrate that rural and transition zones of the study area have higher dominance of planted tree species on the margins, whereas urban zone exhibits comparatively uniform dominance for all species. Our study also highlights the need for conservation of FMV to ensure agroecosystem health as a prerequisite for sustainable socioecological development.


Asunto(s)
Conservación de los Recursos Naturales , Monitoreo del Ambiente , Agricultura , Biodiversidad , Ecosistema , Europa (Continente) , Humanos , India
10.
J Cardiovasc Electrophysiol ; 30(6): 918-925, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30907462

RESUMEN

INTRODUCTION: Time-to-isolation (TTI) guided ablation protocols have been developed to ensure durable pulmonary vein isolation (PVI) in cryoballoon ablation (CBA). The aim was to determine the feasibility and safety of the fourth generation cryoballoon (CBG4) with a shortened tip. METHODS AND RESULTS: Consecutive patients scheduled for initial atrial fibrillation (AF) ablation were prospectively included. PVI with the 28 mm CBG4 and the latest 20 mm spiral-mapping catheter (SMC) was performed. A total of 302 pulmonary veins (PVs) in 76 patients (64.8 ± 10.4 years, paroxysmal AF 49%) were treated with 617 applications. Left atrium (LA) time, fluoroscopy time, and dose-area product were 65.5 ± 19.2 minutes, 14.6 ± 5.6 minutes, and 1094 (738; 2097) cGy·cm2 , respectively. PVI in cryoballoon technique was achieved in 302 of 302 (100%) PVs. TTI was determined in 256 (84.8%) of PVs. The mean TTI was 45.3 ± 26.4 seconds. Single-shot isolation was achieved in 247 (82%) PVs. In 6 of 302 (2.0%) PV the SMC was changed to a stiff wire to isolate the PV because of instability, and in 17 of 302 (5.6%) of PVs, the 23 mm CB was used to isolate. No radiofrequency touch-up applications were applied. The mean nadir balloon temperature was -44.8°C ± 6.6°C. Balloon dislodgement during positioning occurred in 3 of 617 (0.5%) applications without complications. One PN palsy occurred which resolved until discharge. One patient suffered from the inflammatory syndrome. CONCLUSION: The CBG4 with a shorter distal tip seems to be safe and effective, and allows determining the TTI in 84.8% of PVs. In case of balloon instability, the exchange of the SMC to a stiff wire or, in small PV, the 23 mm cryoballoon facilitate PVI.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Criocirugía/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
11.
Europace ; 21(9): 1313-1324, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31199860

RESUMEN

AIMS: To evaluate the effectiveness and safety of cryoballoon ablation (CBA) compared with radiofrequency ablation (RFA) for symptomatic paroxysmal or drug-refractory persistent atrial fibrillation (AF). METHODS AND RESULTS: Prospective cluster cohort study in experienced CBA and RFA centres. Primary endpoint was 'atrial arrhythmia recurrence', secondary endpoints were as follows: procedural results, safety, and clinical course. A total of 4189 patients were included: CBA 2329 (55.6%) and RFA 1860 (44.4%). Cryoballoon ablation population was younger, with fewer comorbidities. Procedure time was longer in the RFA group (P = 0.01). Radiation exposure was 2487 (CBA) and 1792 cGycm2 (RFA) (P < 0.001). Follow-up duration was 441 (CBA) and 511 days (RFA) (P < 0.0001). Primary endpoint occurred in 30.7% (CBA) and 39.4% patients (RFA) [adjusted hazard ratio (adjHR) 0.85, 95% confidence interval (CI) 0.70-1.04; P = 0.12). In paroxysmal AF, CBA resulted in a lower risk of recurrence (adjHR 0.80, 95% CI 0.64-0.99; P = 0.047). In persistent AF, the primary outcome was not different between groups. Major adverse cardiovascular and cerebrovascular event rates were 1.0% (CBA) and 2.8% (RFA) (adjHR 0.53, 95% CI 0.26-1.10; P = 0.088). Re-ablations (adjHR 0.46, 95% CI 0.34-0.61; P < 0.0001) and adverse events during follow-up (adjHR 0.64, 95% CI 0.48-0.88; P = 0.005) were less common after CBA. Higher rehospitalization rates with RFA were caused by re-ablations. CONCLUSIONS: The primary endpoint did not differ between CBA and RFA. Cryoballoon ablation was completed rapidly; the radiation exposure was greater. Rehospitalization due to re-ablations and adverse events during follow-up were observed significantly less frequently after CBA than after RFA. Subgroup analysis suggested a lower risk of recurrence after CBA in paroxysmal AF. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01360008), https://clinicaltrials.gov/ct2/show/NCT01360008.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Anciano , Fibrilación Atrial/fisiopatología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Readmisión del Paciente , Complicaciones Posoperatorias/epidemiología , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Dosis de Radiación , Recurrencia , Reoperación , Resultado del Tratamiento
12.
Platelets ; 30(3): 341-347, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29521570

RESUMEN

Dual antiplatelet therapy (DAPT) with aspirin and a P2Y12 inhibitor is a mainstay of the prevention of stent thrombosis following percutaneous coronary intervention (PCI). In the 2015 European guidelines for the management of acute coronary syndrome (ACS), prasugrel (PRA) and ticagrelor (TICA) combined with aspirin are recommended as first-line therapy. Clopidogrel (CLO) is recommended as an alternative medication for patients with contradictions to these new drugs. This single-center study analyzed the platelet function of 809 ACS patients undergoing PCI and treatment with DAPT. The platelet response to ADP was determined using Multiplate® analyzer at a median of 3 days after PCI in 254 patients treated with PRA (loading dose [LD] 60 mg, 10 mg qd), 162 patients receiving TICA (LD 180 mg, D 90 mg bid), and 393 CLO-treated patients (LD 600 mg, 75 mg qd). An aggregation >468 arbitrary units (AU)*min was defined as "high on-treatment platelet reactivity" (HPR), <188 AU*min as "low on-treatment platelet reactivity" (LPR). Platelet response in PRA-treated patients was lower compared to CLO or TICA (median; interquartile range: PRA 220 [163-275] AU*min vs. CLO 268 [186-387] AU*min, p < 0.001 vs. TICA 245 [190-320] AU*min, p = 0.001). Only 1.6% of PRA patients were stratified as HPR and 34.6% as LPR, while in the TICA group 1.9% fulfilled the criteria of HPR and 24.1% criteria of LPR. Sixteen percent of CLO patients were stratified as HPR and 26.2% as LPR. In a real-world cohort of ACS patients following PCI, PRA results in more potent inhibition of platelet function compared to CLO and TICA. TICA achieves a consistent antiplatelet effect with reduced rates of HPR and LPR in relation to CLO.


Asunto(s)
Síndrome Coronario Agudo/tratamiento farmacológico , Plaquetas/metabolismo , Clopidogrel/uso terapéutico , Pruebas de Función Plaquetaria/métodos , Clorhidrato de Prasugrel/uso terapéutico , Ticagrelor/uso terapéutico , Síndrome Coronario Agudo/patología , Anciano , Clopidogrel/farmacología , Femenino , Humanos , Masculino , Clorhidrato de Prasugrel/farmacología , Estudios Retrospectivos , Ticagrelor/farmacología
13.
Heart Vessels ; 34(7): 1196-1202, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30607538

RESUMEN

According to current guidelines prophylactic implantable cardioverter-defibrillator (ICD) therapy is recommended in patients with significantly impaired left ventricular systolic function. However, the recently published DANISH trial did not find a significantly lower long-term rate of death from any cause compared with usual clinical care in patients with non-ischemic cardiomyopathy. We investigated whether registry data from a multi-center 'real-life' registry on patients with non-ischemic cardiomyopathy are similar to this trial. The German Device Registry (DEVICE) is a nationwide, prospective registry with one-year follow-up investigating 5451 patients receiving device implantations in 50 German centers. The present analysis of DEVICE focused on patients with non-ischemic cardiomyopathy and a left ventricular ejection fraction ≤35% who received a prophylactic ICD. Out of 779 patients with symptomatic heart failure and nonischemic cardiomyopathy, 33.1% received a single chamber ICD (VVI), while 11.0% were implanted with a dual-chamber ICD (DDD), and 55.8% received a defibrillator system for cardiac resynchronization therapy. Median follow-up was 16.1 months. 90.7% were alive at follow-up, 9.3% had died during this period. Overall mortality after one year was 5.4%. Overall mortality one year after implantation was significantly increased in patients 68 years and older(7.9%) as compared to younger patients (59-68 years: 2.5%; < 59 years: 3.8%; p < 0.015). Data from the present registry support the recently published results of the DANISH trial. In particular the influence of an increased age as proven in the DANISH trial might also play a role in the present collective. This limits the potential beneficial effect of ICD therapy in particular in the elderly population.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Anciano , Cardiomiopatías/mortalidad , Causas de Muerte , Femenino , Alemania/epidemiología , Insuficiencia Cardíaca , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Números Necesarios a Tratar , Estudios Prospectivos , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistema de Registros , Tasa de Supervivencia
15.
J Cardiovasc Electrophysiol ; 28(3): 258-265, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27925337

RESUMEN

INTRODUCTION: Despite a rising demand for catheter ablation (CA) of atrial fibrillation (AF) in an elderly population, complication and success rates are not fully elucidated. We sought to compare complication rates of CA of AF in patients ≥75 versus <75 years of age. METHODS AND RESULTS: Patients with symptomatic, drug-refractory AF were prospectively enrolled from January 2007 to 2010 in this multicenter study. A total of 4,449 patients, group 1 ≥75 years and group 2 <75 years (n = 227, age 77.3 ± 2.2 vs. 59.7 ± 9.8 years, 52.0% vs. n = 4,222, 68.9% male, CHA2 DS2 -VASc-Score 3.7 ± 1.0 vs. 1.7 ± 1.2; P < 0.001, respectively), with paroxysmal AF (59.9% in group 1 vs. 63.3% in group 2, P = 0.30), and persistent AF (34.8% in group 1 vs. 29.4% in group 2, P = 0.082) underwent CA of AF. A centralized follow-up was obtained in 4,347 patients by the Institute for Myocardial Infarction Research (IHF, Ludwigshafen). There was a significant difference between periprocedural stroke rates in the elderly versus the younger cohort (1.3% vs. 0.1%, P < 0.01). In-hospital severe nonfatal complications did not differ significantly between the groups (4.4% vs. 2.7%, P = 0.14). Other procedure-related, in-hospital complications were not significantly different. After a mean follow-up of 472 ± 99 days (group 1) and 477 ± 94 days (group 2), no differences were found in complication rates. CONCLUSION: CA of AF in patients ≥75 years is associated with higher in-hospital stroke rates. In a 1-year follow-up, complication rates do not differ between the groups.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Accidente Cerebrovascular/etiología , Potenciales de Acción , Factores de Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Supervivencia sin Enfermedad , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Europace ; 19(6): 968-975, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27353325

RESUMEN

AIMS: To analyse the long-term safety of implantable cardioverter defibrillators (ICDs) in patients discharged within 24 h or after 2- 5-day hospitalization, respectively, after complication-free implantation, in circumstances of actual care. METHODS AND RESULTS: Patients in the multicentre, nationwide German DEVICE registry were contacted 12-15 months after their first ICD implantation or device replacement. Data were collected on complications, potential arrhythmic events, syncope, resuscitation, ablation procedures, cardiac events, hospitalizations, heart failure status, change of medication, and quality of life. Of 2356 patients from 43 centres, 527 patients were discharged within 24 h and 1829 were hospitalized routinely for >24 h after complication-free implantations. The disease profiles and rates of co-morbidities were similar at baseline for both cohorts. During between 384 and 543 days of follow-up, there were no significant differences between the groups in terms of complications, hospitalizations, or quality of life. One-year rates of death were 4.5% in patients discharged early compared with 7.2% in hospitalized patients (hazard ratio 0.65; 95% confidence interval 0.42-1.02; P = 0.052). Rates of major adverse cardiovascular events or defibrillator events were not higher in patients discharged after 24 h. In both groups, a high rate of patients declared that they would opt for the procedure again in the same situation. CONCLUSION: Data from a large-scale registry reflecting current day-to-day practice in Germany suggest that most patients can be discharged safely within 24 h of successful ICD implantation if there are no procedure-related events. Follow-up data up to 1.5 years after implantation did not raise long-term safety concerns.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Tiempo de Internación , Alta del Paciente , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Comorbilidad , Supervivencia sin Enfermedad , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Alemania , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Seguridad del Paciente , Estudios Prospectivos , Falla de Prótesis , Calidad de Vida , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Radiol Med ; 122(2): 113-120, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27844188

RESUMEN

OBJECTIVE: To evaluate the correlation between aortic root calcification (ARC) markers and coronary artery calcification (CAC) derived from coronary artery calcium scoring (CACS) and their ability to predict obstructive coronary artery disease (CAD). METHODS: We retrospectively analyzed 189 patients (47% male, age 60.3 ± 11.1 years) with an intermediate probability of CAD who underwent clinically indicated CACS and coronary CT angiography (CCTA). ARC markers [aortic root calcium score (ARCS) and volume (ARCV)] were calculated and compared to CAC markers: coronary artery calcium score (CACS), volume (CACV), and mass (CACM). CCTA datasets were visually evaluated for significant CAD (stenosis ≥ 50%) and the ability of ARC markers to predict obstructive CAD was assessed. RESULTS: ARCS (mean 67.7 ± 189.5) and ARCV (mean 67.3 ± 184.7) showed significant differences between patients with and without CAC (109.4 ± 238.6 vs 9.42 ± 31.4, p < 0.0001; 108.5 ± 232.4 vs 9.9 ± 30.5, p < 0.0001). A strong correlation was found for ARCS and ARCV with CACS, CACM, and CACV (all p < 0.0001). In a multivariate analysis, ARCS (OR 1.09, p = 0.033) and ARCV (OR 1.12, p = 0.046) were independent markers for CAC. Using a receiver-operating characteristics analysis, the AUC to detect severe CAC was 0.71 (p < 0.0001) and 0.71 (p < 0.0001) for ARCS and ARCV, respectively. ARCS (0.67, p < 0.0001) and ARCV (0.68, p < 0.0001) showed discriminatory power for predicting obstructive CAD, yielding sensitivities 61 and 78% and specificities of 62 and 80%, respectively. CONCLUSION: ARC markers are associated with and independently predict the presence of CAC and obstructive CAD. Further testing is required in patients with severe ARC and significant CAD in order to reliably obtain these markers from thoracic-CT or X-ray for proper risk classification.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Calcificación Vascular/diagnóstico por imagen , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Índice de Masa Corporal , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Estenosis Coronaria/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/complicaciones
18.
Europace ; 18(3): 368-75, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26504108

RESUMEN

AIMS: First-line ablation prior to antiarrhythmic drug (AAD) therapy is an option for symptomatic paroxysmal atrial fibrillation (PAF); however, the optimal ablation technique, radiofrequency (RF), or cryoballoon (CB) has to be determined. METHODS AND RESULTS: The FREEZE Cohort Study compares RF and CB ablation. Treatment-naïve patients were documented in the FREEZEplus Registry. Periprocedural data and outcome were analysed. From 2011 to 2014, a total of 373/4184 (8.9%) patients with PAF naïve to AAD were identified. Pulmonary vein isolation (PVI) was performed with RF (n = 180) or CB (n = 193). In the RF group, patients were older (65 vs. 61 years, P < 0.01) compared with the CB group. The procedure time was significantly shorter and radiation exposure higher in the CB group. Major adverse events occurred in 1.6% (CB) and 3.7% (RF) of patients (P = 0.22). AF/atrial tachycardia (AT) recurrence until discharge was 4.5% (RF) and 8.5% (CB, P = 0.2). Follow-up (FU) ≥12 months was available in 99 (RF) and 107 (CB) patients. After 1.4 years of FU, freedom from AF/atrial tachycardia (AT) was 61% (RF) and 71% (CB, P = 0.11). In the RF group, more patients underwent cardioversion, and a trend for more repeat ablations was observed. Persistent phrenic nerve palsy was observed in one patient treated by CB. CONCLUSION: First-line ablation for PAF is safe and effective with either RF or CB. The procedure was faster with the CB, but the radiation exposure was higher. Although there was a trend for more recurrences and complications in the RF group, a more favourable risk profile in patients undergoing CB ablation might have biased the results. CLINICALTRIALSGOV IDENTIFIER: NCT01360008.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Dosis de Radiación , Exposición a la Radiación , Recurrencia , Sistema de Registros , Reoperación , Factores de Riesgo , Sudáfrica , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
19.
J Electrocardiol ; 49(2): 117-23, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26806120

RESUMEN

AIMS: This investigation addresses procedural characteristics of catheter ablation in patients with atrial fibrillation (AF) and sinus bradycardia. METHODS: From the prospective, multi-center German Ablation Registry 1073 patients with sinus rhythm at the time of AF ablation were divided into two groups according to heart rate at start of procedure (A, <60 beats per minute (bpm), n=197; B, 60-99bpm, n=876). RESULTS: Acute procedural success was high (≥98%) and similar between groups. Procedure duration and energy application time were increased in group A (180min vs. 155min and 2561s vs. 1879s, respectively). Major complications were more frequent in group A (2.2% vs. 0.5%), and a greater proportion of these patients was discharged under antiarrhythmic medication (64% vs. 52%). CONCLUSION: Catheter ablation of AF with concomitant sinus bradycardia is associated with high procedural efficacy, longer procedure- and energy application durations, and a slightly elevated complication rate.


Asunto(s)
Fibrilación Atrial/mortalidad , Fibrilación Atrial/cirugía , Bradicardia/mortalidad , Ablación por Catéter/mortalidad , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Mapeo del Potencial de Superficie Corporal/mortalidad , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Bradicardia/cirugía , Ablación por Catéter/estadística & datos numéricos , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/mortalidad , Cirugía Asistida por Computador/estadística & datos numéricos , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA