Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Brain ; 138(Pt 3): 577-88, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25582580

RESUMEN

Constant drive provided to the human lumbar spinal cord by epidural electrical stimulation can cause local neural circuits to generate rhythmic motor outputs to lower limb muscles in people paralysed by spinal cord injury. Epidural spinal cord stimulation thus allows the study of spinal rhythm and pattern generating circuits without their configuration by volitional motor tasks or task-specific peripheral feedback. To reveal spinal locomotor control principles, we studied the repertoire of rhythmic patterns that can be generated by the functionally isolated human lumbar spinal cord, detected as electromyographic activity from the legs, and investigated basic temporal components shared across these patterns. Ten subjects with chronic, motor-complete spinal cord injury were studied. Surface electromyographic responses to lumbar spinal cord stimulation were collected from quadriceps, hamstrings, tibialis anterior, and triceps surae in the supine position. From these data, 10-s segments of rhythmic activity present in the four muscle groups of one limb were extracted. Such samples were found in seven subjects. Physiologically adequate cycle durations and relative extension- and flexion-phase durations similar to those needed for locomotion were generated. The multi-muscle activation patterns exhibited a variety of coactivation, mixed-synergy and locomotor-like configurations. Statistical decomposition of the electromyographic data across subjects, muscles and samples of rhythmic patterns identified three common temporal components, i.e. basic or shared activation patterns. Two of these basic patterns controlled muscles to contract either synchronously or alternatingly during extension- and flexion-like phases. The third basic pattern contributed to the observed muscle activities independently from these extensor- and flexor-related basic patterns. Each bifunctional muscle group was able to express both extensor- and flexor-patterns, with variable ratios across the samples of rhythmic patterns. The basic activation patterns can be interpreted as central drives implemented by spinal burst generators that impose specific spatiotemporally organized activation on the lumbosacral motor neuron pools. Our data thus imply that the human lumbar spinal cord circuits can form burst-generating elements that flexibly combine to obtain a wide range of locomotor outputs from a constant, repetitive input. It may be possible to use this flexibility to incorporate specific adaptations to gait and stance to improve locomotor control, even after severe central nervous system damage.


Asunto(s)
Estimulación Eléctrica/métodos , Potenciales Evocados Motores/fisiología , Trastornos del Movimiento/etiología , Trastornos del Movimiento/terapia , Traumatismos de la Médula Espinal/complicaciones , Adolescente , Adulto , Biofisica , Distribución de Chi-Cuadrado , Electromiografía , Femenino , Lateralidad Funcional , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Periodicidad , Médula Espinal/fisiología , Traumatismos de la Médula Espinal/terapia , Adulto Joven
2.
J Neurophysiol ; 114(1): 400-10, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25904708

RESUMEN

In individuals with motor-complete spinal cord injury, epidural stimulation of the lumbosacral spinal cord at 2 Hz evokes unmodulated reflexes in the lower limbs, while stimulation at 22-60 Hz can generate rhythmic burstlike activity. Here we elaborated on an output pattern emerging at transitional stimulation frequencies with consecutively elicited reflexes alternating between large and small. We analyzed responses concomitantly elicited in thigh and leg muscle groups bilaterally by epidural stimulation in eight motor-complete spinal cord-injured individuals. Periodic amplitude modulation of at least 20 successive responses occurred in 31.4% of all available data sets with stimulation frequency set at 5-26 Hz, with highest prevalence at 16 Hz. It could be evoked in a single muscle group only but was more strongly expressed and consistent when occurring in pairs of antagonists or in the same muscle group bilaterally. Latencies and waveforms of the modulated reflexes corresponded to those of the unmodulated, monosynaptic responses to 2-Hz stimulation. We suggest that the cyclical changes of reflex excitability resulted from the interaction of facilitatory and inhibitory mechanisms emerging after specific delays and with distinct durations, including postactivation depression, recurrent inhibition and facilitation, as well as reafferent feedback activation. The emergence of large responses within the patterns at a rate of 5.5/s or 8/s may further suggest the entrainment of spinal mechanisms as involved in clonus. The study demonstrates that the human lumbosacral spinal cord can organize a simple form of rhythmicity through the repetitive activation of spinal reflex circuits.


Asunto(s)
Reflejo/fisiología , Traumatismos de la Médula Espinal/fisiopatología , Médula Espinal/fisiopatología , Adolescente , Adulto , Estimulación Eléctrica/métodos , Electromiografía , Femenino , Humanos , Pierna/fisiopatología , Región Lumbosacra , Masculino , Músculo Esquelético/fisiopatología , Adulto Joven
3.
Artif Organs ; 39(10): 834-40, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26471133

RESUMEN

Interest in transcutaneous electrical stimulation of the lumbosacral spinal cord is increasing in human electrophysiological and clinical studies. The stimulation effects on lower limb muscles depend on the depolarization of segmentally organized posterior root afferents and, thus, the rostro-caudal stimulation site. In previous studies, selective stimulation was achieved by varying the positions of single self-adhesive electrodes over the thoracolumbar spine. Here, we developed a multi-electrode surface array consisting of 3 × 8 electrode pads and tested its stimulation-site specificity. The array was placed longitudinally over the spine covering the T10-L2 vertebrae. Two different hydrogel layer configurations were utilized: a single layer adhered to all electrode pads of the array and a configuration comprised of eight separate strips attached to the three transverse electrode pads of each level. Voltage measurements demonstrated that an effectively focused field distribution along the longitudinal extent of the array was not accomplished when using the single continuous hydrogel layer, and segmental selective stimulation of the posterior root afferents was not possible. The separate strips produced a focused electric field distribution at the rostro-caudal level of the electrode pads selected for stimulation. This configuration allowed for the preferential elicitation of posterior root-muscle reflexes in either the L2-L4 innervated quadriceps or the L5-S2 innervated triceps surae muscle groups. Such multi-electrode array for transcutaneous spinal cord stimulation shall allow for improved control of stimulation conditions in electrophysiological studies and time-dependent and site-specific stimulation patterns for neuromodulation applications.


Asunto(s)
Raíces Nerviosas Espinales/fisiopatología , Estimulación Eléctrica Transcutánea del Nervio/métodos , Electrodos , Humanos , Región Lumbosacra/inervación , Región Lumbosacra/fisiopatología , Estimulación Eléctrica Transcutánea del Nervio/instrumentación
4.
Artif Organs ; 39(10): E176-86, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26450344

RESUMEN

The level of sustainable excitability within lumbar spinal cord circuitries is one of the factors determining the functional outcome of locomotor therapy after motor-incomplete spinal cord injury. Here, we present initial data using noninvasive transcutaneous lumbar spinal cord stimulation (tSCS) to modulate this central state of excitability during voluntary treadmill stepping in three motor-incomplete spinal cord-injured individuals. Stimulation was applied at 30 Hz with an intensity that generated tingling sensations in the lower limb dermatomes, yet without producing muscle reflex activity. This stimulation changed muscle activation, gait kinematics, and the amount of manual assistance required from the therapists to maintain stepping with some interindividual differences. The effect on motor outputs during treadmill-stepping was essentially augmentative and step-phase dependent despite the invariant tonic stimulation. The most consistent modification was found in the gait kinematics, with the hip flexion during swing increased by 11.3° ± 5.6° across all subjects. This preliminary work suggests that tSCS provides for a background increase in activation of the lumbar spinal locomotor circuitry that has partially lost its descending drive. Voluntary inputs and step-related feedback build upon the stimulation-induced increased state of excitability in the generation of locomotor activity. Thus, tSCS essentially works as an electrical neuroprosthesis augmenting remaining motor control.


Asunto(s)
Traumatismos de la Médula Espinal/terapia , Estimulación de la Médula Espinal , Caminata/fisiología , Adulto , Fenómenos Biomecánicos , Electromiografía , Femenino , Marcha/fisiología , Humanos , Región Lumbosacra , Masculino , Músculo Esquelético/fisiopatología , Médula Espinal/fisiopatología
5.
J Spinal Cord Med ; 37(2): 202-11, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24090290

RESUMEN

CONTEXT/OBJECTIVE: To examine the effects of transcutaneous spinal cord stimulation (tSCS) on lower-limb spasticity. DESIGN: Interventional pilot study to produce preliminary data. SETTING: Department of Physical Medicine and Rehabilitation, Wilhelminenspital, Vienna, Austria. PARTICIPANTS: Three subjects with chronic motor-incomplete spinal cord injury (SCI) who could walk ≥10 m. INTERVENTIONS: Two interconnected stimulating skin electrodes (Ø 5 cm) were placed paraspinally at the T11/T12 vertebral levels, and two rectangular electrodes (8 × 13 cm) on the abdomen for the reference. Biphasic 2 ms-width pulses were delivered at 50 Hz for 30 minutes at intensities producing paraesthesias but no motor responses in the lower limbs. OUTCOME MEASURES: The Wartenberg pendulum test and neurological recordings of surface-electromyography (EMG) were used to assess effects on exaggerated reflex excitability. Non-functional co-activation during volitional movement was evaluated. The timed 10-m walk test provided measures of clinical function. RESULTS: The index of spasticity derived from the pendulum test changed from 0.8 ± 0.4 pre- to 0.9 ± 0.3 post-stimulation, with an improvement in the subject with the lowest pre-stimulation index. Exaggerated reflex responsiveness was decreased after tSCS across all subjects, with the most profound effect on passive lower-limb movement (pre- to post-tSCS EMG ratio: 0.2 ± 0.1), as was non-functional co-activation during voluntary movement. Gait speed values increased in two subjects by 39%. CONCLUSION: These preliminary results suggest that tSCS, similar to epidurally delivered stimulation, may be used for spasticity control, without negatively impacting residual motor control in incomplete SCI. Further study in a larger population is warranted.


Asunto(s)
Espasticidad Muscular/terapia , Traumatismos de la Médula Espinal/terapia , Estimulación Eléctrica Transcutánea del Nervio , Adulto , Femenino , Humanos , Extremidad Inferior/inervación , Extremidad Inferior/fisiopatología , Masculino , Proyectos Piloto , Traumatismos de la Médula Espinal/fisiopatología
6.
Nat Commun ; 14(1): 3276, 2023 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-37280242

RESUMEN

Lumbar central pattern generators (CPGs) control the basic rhythm and coordinate muscle activation underlying hindlimb locomotion in quadrupedal mammals. The existence and function of CPGs in humans have remained controversial. Here, we investigated a case of a male individual with complete thoracic spinal cord injury who presented with a rare form of self-sustained rhythmic spinal myoclonus in the legs and rhythmic activities induced by epidural electrical stimulation (EES). Analysis of muscle activation patterns suggested that the myoclonus tapped into spinal circuits that generate muscle spasms, rather than reflecting locomotor CPG activity as previously thought. The EES-induced patterns were fundamentally different in that they included flexor-extensor and left-right alternations, hallmarks of locomotor CPGs, and showed spontaneous errors in rhythmicity. These motor deletions, with preserved cycle frequency and period when rhythmic activity resumed, were previously reported only in animal studies and suggest a separation between rhythm generation and pattern formation. Spinal myoclonus and the EES-induced activity demonstrate that the human lumbar spinal cord contains distinct mechanisms for generating rhythmic multi-muscle patterns.


Asunto(s)
Generadores de Patrones Centrales , Mioclonía , Traumatismos de la Médula Espinal , Animales , Masculino , Humanos , Médula Espinal/fisiología , Locomoción/fisiología , Miembro Posterior , Generadores de Patrones Centrales/fisiología , Mamíferos
7.
J Clin Med ; 11(13)2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35807121

RESUMEN

Recent studies of epidural electrical spinal cord stimulation have shown the enabling and, in some cases, the recovery of motor functions thought to be irreversibly lost due to severe spinal cord injury [...].

8.
Artif Organs ; 35(3): 257-62, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21401670

RESUMEN

Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation, and movement. The human lumbar cord has become a target for modification of motor control by epidural and, more recently, by transcutaneous spinal cord stimulation. Posterior columns of the lumbar spinal cord represent a vertical system of axons and when activated can add other inputs to the motor control of the spinal cord than stimulated posterior roots. We used a detailed three-dimensional volume conductor model of the torso and the McIntyre-Richard-Grill axon model to calculate the thresholds of axons within the posterior columns in response to transcutaneous lumbar spinal cord stimulation. Superficially located large-diameter posterior column fibers with multiple collaterals have a threshold of 45.4 V, three times higher than posterior root fibers (14.1 V). With the stimulation strength needed to activate posterior column axons, posterior root fibers of large and small diameters as well as anterior root fibers are coactivated. The reported results inform on these threshold differences, when stimulation is applied to the posterior structures of the lumbar cord at intensities above the threshold of large-diameter posterior root fibers.


Asunto(s)
Axones/fisiología , Región Lumbosacra/inervación , Médula Espinal/fisiología , Estimulación Eléctrica Transcutánea del Nervio , Humanos , Modelos Neurológicos , Estimulación Eléctrica Transcutánea del Nervio/métodos
9.
Brain Sci ; 11(4)2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33917893

RESUMEN

Gait dysfunction and spasticity are common debilitating consequences of multiple sclerosis (MS). Improvements of these motor impairments by lumbar transcutaneous spinal cord stimulation (tSCS) have been demonstrated in spinal cord injury. Here, we explored for the first time the motor effects of lumbar tSCS applied at 50 Hz for 30 min in 16 individuals with MS and investigated their temporal persistence post-intervention. We used a comprehensive protocol assessing walking ability, different presentations of spasticity, standing ability, manual dexterity, and trunk control. Walking ability, including walking speed and endurance, was significantly improved for two hours beyond the intervention and returned to baseline after 24 h. Muscle spasms, clonus duration, and exaggerated stretch reflexes were reduced for two hours, and clinically assessed lower-extremity muscle hypertonia remained at improved levels for 24 h post-intervention. Further, postural sway during normal standing with eyes open was decreased for two hours. No changes were detected in manual dexterity and trunk control. Our results suggest that transcutaneous lumbar SCS can serve as a clinically accessible method without known side effects that holds the potential for substantial clinical benefit across the disability spectrum of MS.

10.
iScience ; 24(1): 101930, 2021 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-33409476

RESUMEN

Epidural electrical stimulation of the spinal cord is an emergent strategy for the neurological recovery of lower-extremity motor function. Motoneuron pools are thought to be recruited by stimulation of posterior roots. Here, we linked electromyographic data of epidurally evoked lower-extremity responses of 34 individuals with upper motoneuron disorders to a population model of the spinal cord constructed using anatomical parameters of thousands of individuals. We identified a relationship between segmental stimulation sites and activated spinal cord segments, which made spinal motor mapping from epidural space possible despite the complex anatomical interface imposed by the posterior roots. Our statistical approach provided evidence for low-threshold sites of posterior roots and effects of monopolar and bipolar stimulation previously predicted by computer modeling and allowed us to test the impact of different upper motoneuron disorders on the evoked responses. Finally, we revealed a statistical association between intraoperative and postoperative mapping of the spinal cord.

11.
Brain Sci ; 11(1)2021 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-33467053

RESUMEN

Epidural electrical stimulation (EES) applied over the human lumbosacral spinal cord provides access to afferent fibers from virtually all lower-extremity nerves. These afferents connect to spinal networks that play a pivotal role in the control of locomotion. Studying EES-evoked responses mediated through these networks can identify some of their functional components. We here analyzed electromyographic (EMG) responses evoked by low-frequency (2-6 Hz) EES derived from eight individuals with chronic, motor complete spinal cord injury. We identified and separately analyzed three previously undescribed response types: first, crossed reflexes with onset latencies of ~55 ms evoked in the hamstrings; second, oligosynaptic reflexes within 50 ms post-stimulus superimposed on the monosynaptic posterior root-muscle reflexes in the flexor muscle tibialis anterior, but with higher thresholds and no rate-sensitive depression; third, polysynaptic responses with variable EMG shapes within 50-450 ms post-stimulus evoked in the tibialis anterior and triceps surae, some of which demonstrated consistent changes in latencies with graded EES. Our observations suggest the activation of commissural neurons, lumbar propriospinal interneurons, and components of the late flexion reflex circuits through group I and II proprioceptive afferent inputs. These potential neural underpinnings have all been related to spinal locomotion in experimental studies.

12.
J Clin Med ; 10(22)2021 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-34830746

RESUMEN

Transcutaneous spinal cord stimulation (tSCS) is a promising intervention that can benefit spasticity control and augment voluntary movement in spinal cord injury (SCI) and multiple sclerosis. Current applications require expert knowledge and rely on the thorough visual analysis of electromyographic (EMG) responses from lower-limb muscles to optimize attainable treatment effects. Here, we devised an automated tSCS setup by combining an electrode array placed over low-thoracic to mid-lumbar vertebrae, synchronized EMG recordings, and a self-operating stimulation protocol to systematically test various stimulation sites and amplitudes. A built-in calibration procedure classifies the evoked responses as reflexes or direct motor responses and identifies stimulation thresholds as recommendations for tSCS therapy. We tested our setup in 15 individuals (five neurologically intact, five SCI, and five Parkinson's disease) and validated the results against blinded ratings from two clinical experts. Congruent results were obtained in 13 cases for electrode positions and in eight for tSCS amplitudes, with deviations of a maximum of one position and 5 to 10 mA in amplitude in the remaining cases. Despite these minor deviations, the calibration found clinically suitable tSCS settings in 13 individuals. In the remaining two cases, the automatic setup and both experts agreed that no reflex responses could be detected. The presented technological developments may facilitate the dissemination of tSCS into non-academic environments and broaden its use for diagnostic and therapeutic purposes.

13.
J Clin Med ; 10(23)2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34884249

RESUMEN

Transcutaneous spinal cord stimulation is a non-invasive method for neuromodulation of sensorimotor function. Its main mechanism of action results from the activation of afferent fibers in the posterior roots-the same structures as targeted by epidural stimulation. Here, we investigated the influence of sagittal spine alignment on the capacity of the surface-electrode-based stimulation to activate these neural structures. We evaluated electromyographic responses evoked in the lower limbs of ten healthy individuals during extension, flexion, and neutral alignment of the thoracolumbar spine. To control for position-specific effects, stimulation in these spine alignment conditions was performed in four different body positions. In comparison to neutral and extended spine alignment, flexion of the spine resulted in a strong reduction of the response amplitudes. There was no such effect on tibial-nerve evoked H reflexes. Further, there was a reduction of post-activation depression of the responses to transcutaneous spinal cord stimulation evoked in spinal flexion. Thus, afferent fibers were reliably activated with neutral and extended spine alignment. Spinal flexion, however, reduced the capacity of the stimulation to activate afferent fibers and led to the co-activation of motor fibers in the anterior roots. This change of action was due to biophysical rather than neurophysiological influences. We recommend applying transcutaneous spinal cord stimulation in body positions that allow individuals to maintain a neutral or extended spine.

14.
J Clin Med ; 9(11)2020 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-33147884

RESUMEN

Deficient ankle control after incomplete spinal cord injury (iSCI) often accentuates walking impairments. Transcutaneous electrical spinal cord stimulation (tSCS) has been shown to augment locomotor activity after iSCI, presumably due to modulation of spinal excitability. However, the effects of possible excitability modulations induced by tSCS on ankle control have not yet been assessed. This study investigated the immediate (i.e., without training) effects during single-sessions of tonic tSCS on ankle control, spinal excitability, and locomotion in ten individuals with chronic, sensorimotor iSCI (American Spinal Injury Association Impairment Scale D). Participants performed rhythmic ankle movements (dorsi- and plantar flexion) at a given rate, and irregular ankle movements following a predetermined trajectory with and without tonic tSCS at 15 Hz, 30 Hz, and 50 Hz. In a subgroup of eight participants, the effects of tSCS on assisted over-ground walking were studied. Furthermore, the activity of a polysynaptic spinal reflex, associated with spinal locomotor networks, was investigated to study the effect of the stimulation on the dedicated spinal circuitry associated with locomotor function. Tonic tSCS at 30 Hz immediately improved maximum dorsiflexion by +4.6° ± 0.9° in the more affected lower limb during the rhythmic ankle movement task, resulting in an increase of +2.9° ± 0.9° in active range of motion. Coordination of ankle movements, assessed by the ability to perform rhythmic ankle movements at a given target rate and to perform irregular movements according to a trajectory, was unchanged during stimulation. tSCS at 30 Hz modulated spinal reflex activity, reflected by a significant suppression of pathological activity specific to SCI in the assessed polysynaptic spinal reflex. During walking, there was no statistical group effect of tSCS. In the subgroup of eight assessed participants, the three with the lowest as well as the one with the highest walking function scores showed positive stimulation effects, including increased maximum walking speed, or more continuous and faster stepping at a self-selected speed. Future studies need to investigate if multiple applications and individual optimization of the stimulation parameters can increase the effects of tSCS, and if the technique can improve the outcome of locomotor rehabilitation after iSCI.

15.
J Neurotrauma ; 37(3): 481-493, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31333064

RESUMEN

Epidural spinal cord stimulation (SCS) is currently regarded as a breakthrough procedure for enabling movement after spinal cord injury (SCI), yet one of its original applications was for spinal spasticity. An emergent method that activates similar target neural structures non-invasively is transcutaneous SCS. Its clinical value for spasticity control would depend on inducing carry-over effects, because the surface-electrode-based approach cannot be applied chronically. We evaluated single-session effects of transcutaneous lumbar SCS in 12 individuals with SCI by a test-battery approach, before, immediately after and 2 h after intervention. Stimulation was applied for 30 min at 50 Hz with an intensity sub-threshold for eliciting reflexes in lower extremity muscles. The tests included evaluations of stretch-induced spasticity (Modified Ashworth Scale [MAS] sum score, pendulum test, electromyography-based evaluation of tonic stretch reflexes), clonus, cutaneous-input-evoked spasms, and the timed 10 m walk test. Across participants, the MAS sum score, clonus, and spasms were significantly reduced immediately after SCS, and all spasticity measures were improved 2 h post-intervention, with large effect sizes and including clinically meaningful improvements. The effect on walking speed varied across individuals. We further conducted a single-case multi-session study over 6 weeks to explore the applicability of transcutaneous SCS as a home-based therapy. Self-application of the intervention was successful; weekly evaluations suggested progressively improving therapeutic effects during the active period and carry-over effects for 7 days. Our results suggest that transcutaneous SCS can be a viable non-pharmacological option for managing spasticity, likely working through enhancing pre- and post-synaptic spinal inhibitory mechanisms, and may additionally serve to identify responders to treatments with epidural SCS.


Asunto(s)
Espasticidad Muscular/terapia , Traumatismos de la Médula Espinal/terapia , Estimulación de la Médula Espinal/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Espasticidad Muscular/diagnóstico , Espasticidad Muscular/etiología , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/diagnóstico , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
16.
PLoS One ; 14(12): e0227057, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31877192

RESUMEN

Posterior root-muscle (PRM) reflexes are short-latency spinal reflexes evoked by epidural or transcutaneous spinal cord stimulation (SCS) in clinical and physiological studies. PRM reflexes share key physiological characteristics with the H reflex elicited by electrical stimulation of large-diameter muscle spindle afferents in the tibial nerve. Here, we compared the H reflex and the PRM reflex of soleus in response to transcutaneous stimulation by studying their recovery cycles in ten neurologically intact volunteers and ten individuals with traumatic, chronic spinal cord injury (SCI). The recovery cycles of the reflexes, i.e., the time course of their excitability changes, were assessed by paired pulses with conditioning-test intervals of 20-5000 ms. Between the subject groups, no statistical difference was found for the recovery cycles of the H reflexes, yet those of the PRM reflexes differed significantly, with a striking suppression in the intact group. When comparing the reflex types, they did not differ in the SCI group, while the PRM reflexes were more strongly depressed in the intact group for durations characteristic for presynaptic inhibition. These differences may arise from the concomitant stimulation of several posterior roots containing afferent fibers of various lower extremity nerves by transcutaneous SCS, producing multi-source heteronymous presynaptic inhibition, and the collective dysfunction of inhibitory mechanisms after SCI contributing to spasticity. PRM-reflex recovery cycles additionally obtained for bilateral rectus femoris, biceps femoris, tibialis anterior, and soleus all demonstrated a stronger suppression in the intact group. Within both subject groups, the thigh muscles showed a stronger recovery than the lower leg muscles, which may reflect a characteristic difference in motor control of diverse muscles. Based on the substantial difference between intact and SCI individuals, PRM-reflex depression tested with paired pulses could become a sensitive measure for spasticity and motor recovery.


Asunto(s)
Reflejo H , Músculo Esquelético/fisiopatología , Traumatismos de la Médula Espinal/fisiopatología , Traumatismos de la Médula Espinal/terapia , Estimulación de la Médula Espinal , Adulto , Femenino , Humanos , Masculino , Músculo Esquelético/fisiología , Reflejo , Médula Espinal/fisiología , Médula Espinal/fisiopatología , Estimulación de la Médula Espinal/métodos , Adulto Joven
17.
Artif Organs ; 32(8): 644-8, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18782137

RESUMEN

Dynamic task-dependent regulation of reflexes controlled by the central nervous system plays an integral part in neurocontrol of locomotion. Such modifications of sensory-motor transmission can be studied by conditioning a test reflex with specific motor tasks. To elicit short-latency test reflexes, we applied a novel transcutaneous spinal cord stimulation technique that depolarizes large-diameter posterior root afferents. These responses, termed posterior root-muscle (PRM) reflexes, are equivalent to the monosynaptic Hoffmann (H)-reflex but can be evoked in several muscles simultaneously. We elicited PRM reflexes in quadriceps, hamstrings, tibialis anterior, and triceps surae in subjects with intact nervous system. During three different conditioning-test paradigms in a standing position, that is, volitional unilateral single- and multi-joint lower limb movements and leaning backward/forward, we recorded characteristic movement-induced modulations of PRM reflexes in the thigh and leg muscle groups. We could thus demonstrate that monosynaptic PRM reflexes in functional extensor and flexor muscles of the thigh and leg can be elicited in upright standing subjects and can be modulated during the execution of postural maneuvers. The significance is that transcutaneous posterior root stimulation allows extending H-reflex studies of a single muscle to the assessment of synaptic transmission of two-neuron reflex arcs at multiple segmental levels simultaneously.


Asunto(s)
Estimulación Eléctrica , Electromiografía , Reflejo H/fisiología , Actividad Motora/fisiología , Propiocepción/fisiología , Adulto , Humanos , Región Lumbosacra , Masculino , Músculo Esquelético/fisiología , Raíces Nerviosas Espinales/fisiología , Muslo/fisiología
18.
PLoS One ; 13(1): e0192013, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29381748

RESUMEN

Epidural electrical stimulation of the lumbar spinal cord is currently regaining momentum as a neuromodulation intervention in spinal cord injury (SCI) to modify dysregulated sensorimotor functions and augment residual motor capacity. There is ample evidence that it engages spinal circuits through the electrical stimulation of large-to-medium diameter afferent fibers within lumbar and upper sacral posterior roots. Recent pilot studies suggested that the surface electrode-based method of transcutaneous spinal cord stimulation (SCS) may produce similar neuromodulatory effects as caused by epidural SCS. Neurophysiological and computer modeling studies proposed that this noninvasive technique stimulates posterior-root fibers as well, likely activating similar input structures to the spinal cord as epidural stimulation. Here, we add a yet missing piece of evidence substantiating this assumption. We conducted in-depth analyses and direct comparisons of the electromyographic (EMG) characteristics of short-latency responses in multiple leg muscles to both stimulation techniques derived from ten individuals with SCI each. Post-activation depression of responses evoked by paired pulses applied either epidurally or transcutaneously confirmed the reflex nature of the responses. The muscle responses to both techniques had the same latencies, EMG peak-to-peak amplitudes, and waveforms, except for smaller responses with shorter onset latencies in the triceps surae muscle group and shorter offsets of the responses in the biceps femoris muscle during epidural stimulation. Responses obtained in three subjects tested with both methods at different time points had near-identical waveforms per muscle group as well as same onset latencies. The present results strongly corroborate the activation of common neural input structures to the lumbar spinal cord-predominantly primary afferent fibers within multiple posterior roots-by both techniques and add to unraveling the basic mechanisms underlying electrical SCS.


Asunto(s)
Vértebras Lumbares/fisiología , Reflejo , Médula Espinal/fisiología , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
19.
Neuroscientist ; 23(6): 649-663, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28351197

RESUMEN

The ability of dedicated spinal circuits, referred to as central pattern generators (CPGs), to produce the basic rhythm and neural activation patterns underlying locomotion can be demonstrated under specific experimental conditions in reduced animal preparations. The existence of CPGs in humans is a matter of debate. Equally elusive is the contribution of CPGs to normal bipedal locomotion. To address these points, we focus on human studies that utilized spinal cord stimulation or pharmacological neuromodulation to generate rhythmic activity in individuals with spinal cord injury, and on neuromechanical modeling of human locomotion. In the absence of volitional motor control and step-specific sensory feedback, the human lumbar spinal cord can produce rhythmic muscle activation patterns that closely resemble CPG-induced neural activity of the isolated animal spinal cord. In this sense, CPGs in humans can be defined by the activity they produce. During normal locomotion, CPGs could contribute to the activation patterns during specific phases of the step cycle and simplify supraspinal control of step cycle frequency as a feedforward component to achieve a targeted speed. Determining how the human CPGs operate will be essential to advance the theory of neural control of locomotion and develop new locomotor neurorehabilitation paradigms.


Asunto(s)
Generadores de Patrones Centrales/fisiología , Locomoción/fisiología , Animales , Humanos , Modelos Neurológicos , Médula Espinal/fisiología , Traumatismos de la Médula Espinal/fisiopatología
20.
Curr Pharm Des ; 23(12): 1805-1820, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27981912

RESUMEN

The mammalian lumbar spinal cord experimentally isolated from supraspinal and afferent feedback input remains capable of expressing some basic locomotor function when appropriately stimulated. This ability has been attributed to spinal neural circuits referred to as central pattern generators (CPGs). In individuals with a severe spinal cord injury, rhythmic activity in paralyzed leg muscles can be generated by phasic proprioceptive feedback during therapist- or robotic-assisted stepping on a motorized treadmill. Here, we critically review to what extent the resulting motor output represents locomotor-like activity, and whether these motor patterns are the result of activation of CPGs, as commonly suggested in the literature. Attempts will be made to further delineate the pivotal roles played by mechanisms such as spinal proprioceptive reflexes and their alterations after spinal cord injury, the central excitability level, and by neurotransmitters critical for spinal locomotor activity. We will discuss the view that the muscle activity produced during assisted passive treadmill stepping is resulting from the entrainment of spinal reflex circuits by the cyclically generated proprioceptive feedback. We suggest that the activation of CPG circuits depends rather on the presence of a sustained tonic excitatory drive, as can be provided by electrical spinal cord stimulation, or by specific combinations of dopaminergic agonists, adrenergic/ dopaminergic precursors and/or 5-HT receptor agonists. Novel rehabilitation strategies using spinal cord stimulation and rhythmic-activity producing drugs during locomotor therapy will pave the way for clinically relevant advances in restoration of motor function in people with severe spinal cord injury.


Asunto(s)
Terapia por Estimulación Eléctrica , Retroalimentación Fisiológica/efectos de los fármacos , Locomoción/efectos de los fármacos , Neurotransmisores/farmacología , Traumatismos de la Médula Espinal , Médula Espinal/efectos de los fármacos , Humanos , Locomoción/fisiología , Médula Espinal/fisiología , Traumatismos de la Médula Espinal/fisiopatología , Traumatismos de la Médula Espinal/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA