Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Soft Matter ; 17(18): 4766-4774, 2021 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-33870399

RESUMEN

Recent advances in hemorheology are extended to study blood rheology across species, which has important clinical implications particularly in intravenous drug scaleup as drugs undergoing clinical trials are first tested in animals. Some of the first hemorheological measurements from seven different species under both steady and transient shear conditions are presented and modeled using a rheological model developed and validated on human blood rheology fit to 20 different donors. Despite similar physiological properties across the blood samples from different species, significant differences are observed, particularly at low shear rates. Blood from species that form rouleaux exhibit a yield-like behavior and enhanced viscoelasticity at low shear rates, while blood from species without rouleaux exhibit nearly Newtonian behavior at similar shear rates. Viscoelasticity due to blood cell deformation is evident for all species at high shear rates. Novel, unidirectional large amplitude oscillatory shear measurements differentiate species. Using the newly acquired data in combination with previous literature data, a new allometric scaling relation is suggested for the low-shear blood viscosity for various mammalian evolutionary orders. Using an established model for arterial branching across species, it is conjectured that the observed hemorheological scaling across species is driven by maintaining a constant wall shear stress in arterial vessels.


Asunto(s)
Viscosidad Sanguínea , Hemorreología , Animales , Humanos , Reología , Estrés Mecánico , Viscosidad
2.
Soft Matter ; 17(47): 10591-10613, 2021 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-34787149

RESUMEN

Due to the potential impact on the diagnosis and treatment of various cardiovascular diseases, work on the rheology of blood has significantly expanded in the last decade, both experimentally and theoretically. Experimentally, blood has been confirmed to demonstrate a variety of non-Newtonian rheological characteristics, including pseudoplasticity, viscoelasticity, and thixotropy. New rheological experiments and the development of more controlled experimental protocols on more extensive, broadly physiologically characterized, human blood samples demonstrate the sensitivity of aspects of hemorheology to several physiological factors. For example, at high shear rates the red blood cells elastically deform, imparting viscoelasticity, while at low shear rates, they form "rouleaux" structures that impart additional, thixotropic behavior. In addition to the advances in experimental methods and validated data sets, significant advances have also been made in both microscopic simulations and macroscopic, continuum, modeling, as well as novel, multiscale approaches. We outline and evaluate the most promising of these recent developments. Although we primarily focus on human blood rheology, we also discuss recent observations on variations observed across some animal species that provide some indication on evolutionary effects.


Asunto(s)
Eritrocitos , Hemorreología , Animales , Humanos , Reología , Viscosidad
3.
Artículo en Inglés | MEDLINE | ID: mdl-35666993

RESUMEN

Conversion cathodes represent a viable route to improve rechargeable Li+ battery energy densities, but their poor electrochemical stability and power density have impeded their practical implementation. Here, we explore the impact cell fabrication, electrolyte interaction, and current density have on the electrochemical performance of FeS2/Li cells by deconvoluting the contributions of the various conversion and intercalation reactions to the overall capacity. By varying the slurry composition and applied pressure, we determine that the capacity loss is primarily due to the large volume changes during (de)lithiation, leading to a degradation of the conductive matrix. Through the application of an external pressure, the loss is minimized by maintaining the conductive matrix. We further determine that polysulfide loss can be minimized by increasing the current density (>C/10), thus reducing the sulfur formation period. Analysis of the kinetics determines that the conversion reactions are rate-limiting, specifically the formation of metallic iron at rates above C/8. While focused on FeS2, our findings on the influence of pressure, electrolyte interaction, and kinetics are broadly applicable to other conversion cathode systems.

4.
Clin Hemorheol Microcirc ; 70(2): 155-172, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29710681

RESUMEN

BACKGROUND: Research on hemorheology is driven in part by its significance in blood diseases and the possible use of hemorheology as a diagnostic tool. However, existing data on blood rheology are limited largely to measurements of steady shear behavior often with varying measurement protocols and insufficient characterization of the physiology. OBJECTIVE: The effects of ex vivo aging and environmental conditions on blood viscosity are investigated to improve standards for hemorheology measurements. METHODS: Measurements on the viscosity of blood from nine healthy donors are obtained and the physiological state of the blood determined. Steady and transient shear measurements are reported as a function of time from withdrawal. The effect of transportation temperature is also assessed. RESULTS: Blood transported at 4 °C may exhibit anomalous viscosity variations for short to intermediate times, as opposed to blood transported at room temperature. A time of approximately 3.0 hours was identified as the maximum time after the initial test that accurate rheological tests can be conducted on blood samples. CONCLUSIONS: Measurement protocol and time limit guidelines are established for conducting accurate rheological measurements on blood.


Asunto(s)
Viscosidad Sanguínea/fisiología , Hemorreología/genética , Envejecimiento , Humanos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA