Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sensors (Basel) ; 11(6): 6257-69, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22163953

RESUMEN

This study reports a CMOS-MEMS condenser microphone implemented using the standard thin film stacking of 0.35 µm UMC CMOS 3.3/5.0 V logic process, and followed by post-CMOS micromachining steps without introducing any special materials. The corrugated diaphragm for the microphone is designed and implemented using the metal layer to reduce the influence of thin film residual stresses. Moreover, a silicon substrate is employed to increase the stiffness of the back-plate. Measurements show the sensitivity of microphone is -42 ± 3 dBV/Pa at 1 kHz (the reference sound-level is 94 dB) under 6 V pumping voltage, the frequency response is 100 Hz-10 kHz, and the S/N ratio >55 dB. It also has low power consumption of less than 200 µA, and low distortion of less than 1% (referred to 100 dB).

2.
Biomed Microdevices ; 11(2): 359-67, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18975094

RESUMEN

A new micromachined circulating polymerase chain reaction (PCR) chip is reported in this study. A novel liquid transportation mechanism utilizing a suction-type membrane and three microvalves were used to create a new microfluidic control module to rapidly transport the DNA samples and PCR reagents around three bio-reactors operating at three different temperatures. When operating at a membrane actuation frequency of 14.29 Hz and a pressure of 5 psi, the sample flow rate in the microfluidic control module can be as high as 18 microL/s. In addition, an array-type microheater was adopted to improve the temperature uniformity in the reaction chambers. Open-type reaction chambers were designed to facilitate temperature calibration. Experimental data from infrared images showed that the percentage of area inside the reaction chamber with a thermal variation of less than 1 degrees C was over 90% for a denaturing temperature of 94 degrees C. Three array-type heaters and temperature sensors were integrated into this new circulating PCR chip to modulate three specific operating temperatures for the denaturing, annealing, and extension steps of a PCR process. With this approach, the cycle numbers and reaction times of the three separate reaction steps can be individually adjusted. To verify the performance of this circulating PCR chip, a PCR process to amplify a detection gene (150 base pairs) associated with the hepatitis C virus was performed. Experimental results showed that DNA samples with concentrations ranging from 10(5) to 10(2)copies/microL can be successfully amplified. Therefore, this new circulating PCR chip may provide a useful platform for genetic identification and molecular diagnosis.


Asunto(s)
Fraccionamiento Químico/instrumentación , Análisis de Inyección de Flujo/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , ARN/genética , ARN/aislamiento & purificación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Succión/instrumentación , Fraccionamiento Químico/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Análisis de Inyección de Flujo/métodos , Calefacción/instrumentación , Membranas Artificiales , Sistemas Microelectromecánicos/instrumentación , Sistemas Microelectromecánicos/métodos , Técnicas Analíticas Microfluídicas/métodos , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Sensibilidad y Especificidad , Succión/métodos
3.
Environ Pollut ; 248: 57-65, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30771748

RESUMEN

Control of organic matter, nutrients and disinfection byproduct formation is a major challenge for the drinking water treatment plants on Matsu Islands, Taiwan, receiving source water from the eutrophic reservoirs. A pilot entrapped biomass reactor (EBR) system was installed as the pretreatment process to reduce organic and nitrogen contents into the drinking water treatment plant. The effects of hydraulic retention time (HRT) and combination of preceding physical treatment (ultraviolet and ultrasound) on the treatment performance were further evaluated. The results showed that the EBR system achieved higher than 81%, 35%, 12% and 46% of reduction in chlorophyll a (Chl a), total COD (TCOD), dissolved organic carbon (DOC) and total nitrogen (TN), respectively under varied influent concentrations. The treatment performance was not significantly influenced by HRT and presence/absence of physical pretreatment and the effluent water quality was stable; however, removal efficiencies and removal rates of Chl a, TCOD and DOC showed strong correlation with their influent concentrations. Excitation-emission matrix (EEM) fluorescence spectroscopy identified fulvic-like and humic-like substances as the two major components of dissolved organic matter (DOM) in the reservoir, and decreased intensity of the major peaks in effluent EEM fluorescence spectra suggested the effective removal of DOM without production of additional amount of soluble microbial products in the EBR. Through the treatment by EBR, about 10% of reduction of total trihalomethane formation potential for the effluent could also be achieved. Therefore, the overall results of this study demonstrate that EBR can be a potential pretreatment process for drinking water treatment plants receiving eutrophic source water.


Asunto(s)
Agua Potable/química , Sustancias Húmicas/análisis , Nitrógeno/análisis , Contaminantes Químicos del Agua/análisis , Purificación del Agua/métodos , Calidad del Agua , Biomasa , Clorofila A , Eutrofización , Fluorescencia , Espectrometría de Fluorescencia , Taiwán , Trihalometanos/análisis
4.
Nucleic Acids Res ; 33(18): e156, 2005 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-16221971

RESUMEN

This paper presents an innovative portable chip-based RT-PCR system for amplification of specific nucleic acid and detection of RNA-based viruses. The miniature RT-PCR chip is fabricated using MEMS (Micro-electro-mechanical-system) techniques, and comprises a micro temperature control module and a PDMS (polydimethylsiloxane)-based microfluidic control module. The heating and sensing elements of temperature control module are both made of platinum and are located within the reaction chambers in order to generate a rapid and uniform thermal cycling. The microfluidic control module is capable of automating testing process with minimum human intervention. In this paper, the proposed miniature RT-PCR system is used to amplify and detect two RNA-based viruses, namely dengue virus type-2 and enterovirus 71 (EV 71). The experimental data confirm the ability of the system to perform a two-step RT-PCR process. The developed miniature system provides a crucial tool for the diagnosis of RNA-based viruses.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Técnicas de Diagnóstico Molecular/instrumentación , Infecciones por Virus ARN/diagnóstico , Virus ARN/aislamiento & purificación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Virus del Dengue/genética , Virus del Dengue/aislamiento & purificación , Enterovirus/genética , Enterovirus/aislamiento & purificación , Virus ARN/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Temperatura
5.
Biosens Bioelectron ; 20(7): 1341-8, 2005 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-15590288

RESUMEN

This paper presents a micro polymerase chain reaction (PCR) chip for the DNA-based diagnosis of microorganism genes and the detection of their corresponding antibiotic-resistant genes. The micro PCR chip comprises cheap biocompatible soda-lime glass substrates with integrated thin-film platinum resistors as heating/sensing elements, and is fabricated using micro-electro-mechanical-system (MEMS) techniques in a reliable batch-fabrication process. The heating and temperature sensing elements are made of the same material and are located inside the reaction chamber in order to ensure a uniform temperature distribution. This study performs the detection of several genes associated with upper respiratory tract infection microorganisms, i.e. Streptococcus pneumoniae, Haemopilus influenze, Staphylococcu aureus, Streptococcus pyogenes, and Neisseria meningitides, together with their corresponding antibiotic-resistant genes. The lower thermal inertia of the proposed micro PCR chip relative to conventional bench-top PCR systems enables a more rapid detection operation with reduced sample and reagent consumption. The experimental data reveal that the high heating and cooling rates of the system (20 and 10 degrees C/s, respectively) permit successful DNA amplification within 15 min. The micro PCR chip is also capable of performing multiple DNA amplification, i.e. the simultaneous duplication of multiple genes under different conditions in separate reaction wells. Compared with the large-scale PCR system, it is greatly advantageous for fast diagnosis of multiple infectious diseases. Multiplex PCR amplification of two DNA segments in the same well is also feasible using the proposed micro device. The developed micro PCR chip provides a crucial tool for genetic analysis, molecular biology, infectious disease detection, and many other biomedical applications.


Asunto(s)
Electroforesis , Reacción en Cadena de la Polimerasa , Infecciones del Sistema Respiratorio/metabolismo , Calor , Factores de Tiempo