Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nature ; 530(7588): 71-6, 2016 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-26779949

RESUMEN

Many procedures in modern clinical medicine rely on the use of electronic implants in treating conditions that range from acute coronary events to traumatic injury. However, standard permanent electronic hardware acts as a nidus for infection: bacteria form biofilms along percutaneous wires, or seed haematogenously, with the potential to migrate within the body and to provoke immune-mediated pathological tissue reactions. The associated surgical retrieval procedures, meanwhile, subject patients to the distress associated with re-operation and expose them to additional complications. Here, we report materials, device architectures, integration strategies, and in vivo demonstrations in rats of implantable, multifunctional silicon sensors for the brain, for which all of the constituent materials naturally resorb via hydrolysis and/or metabolic action, eliminating the need for extraction. Continuous monitoring of intracranial pressure and temperature illustrates functionality essential to the treatment of traumatic brain injury; the measurement performance of our resorbable devices compares favourably with that of non-resorbable clinical standards. In our experiments, insulated percutaneous wires connect to an externally mounted, miniaturized wireless potentiostat for data transmission. In a separate set-up, we connect a sensor to an implanted (but only partially resorbable) data-communication system, proving the principle that there is no need for any percutaneous wiring. The devices can be adapted to sense fluid flow, motion, pH or thermal characteristics, in formats that are compatible with the body's abdomen and extremities, as well as the deep brain, suggesting that the sensors might meet many needs in clinical medicine.


Asunto(s)
Implantes Absorbibles , Encéfalo/metabolismo , Electrónica/instrumentación , Monitoreo Fisiológico/instrumentación , Prótesis e Implantes , Silicio , Implantes Absorbibles/efectos adversos , Administración Cutánea , Animales , Temperatura Corporal , Encéfalo/cirugía , Diseño de Equipo , Hidrólisis , Masculino , Monitoreo Fisiológico/efectos adversos , Especificidad de Órganos , Presión , Prótesis e Implantes/efectos adversos , Ratas , Ratas Endogámicas Lew , Telemetría/instrumentación , Tecnología Inalámbrica/instrumentación
2.
Nat Mater ; 15(7): 782-791, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27088236

RESUMEN

Bioresorbable silicon electronics technology offers unprecedented opportunities to deploy advanced implantable monitoring systems that eliminate risks, cost and discomfort associated with surgical extraction. Applications include postoperative monitoring and transient physiologic recording after percutaneous or minimally invasive placement of vascular, cardiac, orthopaedic, neural or other devices. We present an embodiment of these materials in both passive and actively addressed arrays of bioresorbable silicon electrodes with multiplexing capabilities, which record in vivo electrophysiological signals from the cortical surface and the subgaleal space. The devices detect normal physiologic and epileptiform activity, both in acute and chronic recordings. Comparative studies show sensor performance comparable to standard clinical systems and reduced tissue reactivity relative to conventional clinical electrocorticography (ECoG) electrodes. This technology offers general applicability in neural interfaces, with additional potential utility in treatment of disorders where transient monitoring and modulation of physiologic function, implant integrity and tissue recovery or regeneration are required.


Asunto(s)
Implantes Absorbibles , Mapeo Encefálico , Ondas Encefálicas/fisiología , Corteza Cerebral/fisiología , Electrodos Implantados , Silicio , Animales , Mapeo Encefálico/instrumentación , Mapeo Encefálico/métodos , Ratas , Silicio/química , Silicio/farmacología
3.
Nat Mater ; 10(4): 316-23, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21378969

RESUMEN

Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. This paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such 'instrumented' balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.


Asunto(s)
Ablación por Catéter/instrumentación , Cateterismo/instrumentación , Catéteres , Técnicas Electrofisiológicas Cardíacas/instrumentación , Animales , Diseño de Equipo , Ensayo de Materiales , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Porcinos
4.
Nat Med ; 24(12): 1830-1836, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30297910

RESUMEN

Peripheral nerve injuries represent a significant problem in public health, constituting 2-5% of all trauma cases1. For severe nerve injuries, even advanced forms of clinical intervention often lead to incomplete and unsatisfactory motor and/or sensory function2. Numerous studies report the potential of pharmacological approaches (for example, growth factors, immunosuppressants) to accelerate and enhance nerve regeneration in rodent models3-10. Unfortunately, few have had a positive impact in clinical practice. Direct intraoperative electrical stimulation of injured nerve tissue proximal to the site of repair has been demonstrated to enhance and accelerate functional recovery11,12, suggesting a novel nonpharmacological, bioelectric form of therapy that could complement existing surgical approaches. A significant limitation of this technique is that existing protocols are constrained to intraoperative use and limited therapeutic benefits13. Herein we introduce (i) a platform for wireless, programmable electrical peripheral nerve stimulation, built with a collection of circuit elements and substrates that are entirely bioresorbable and biocompatible, and (ii) the first reported demonstration of enhanced neuroregeneration and functional recovery in rodent models as a result of multiple episodes of electrical stimulation of injured nervous tissue.


Asunto(s)
Estimulación Eléctrica/métodos , Regeneración Nerviosa/fisiología , Traumatismos de los Nervios Periféricos/terapia , Cicatrización de Heridas/fisiología , Implantes Absorbibles/normas , Estimulación Eléctrica/instrumentación , Humanos , Traumatismos de los Nervios Periféricos/fisiopatología , Recuperación de la Función , Tecnología Inalámbrica
5.
Sci Transl Med ; 2(24): 24ra22, 2010 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-20375008

RESUMEN

In all current implantable medical devices such as pacemakers, deep brain stimulators, and epilepsy treatment devices, each electrode is independently connected to separate control systems. The ability of these devices to sample and stimulate tissues is hindered by this configuration and by the rigid, planar nature of the electronics and the electrode-tissue interfaces. Here, we report the development of a class of mechanically flexible silicon electronics for multiplexed measurement of signals in an intimate, conformal integrated mode on the dynamic, three-dimensional surfaces of soft tissues in the human body. We demonstrate this technology in sensor systems composed of 2016 silicon nanomembrane transistors configured to record electrical activity directly from the curved, wet surface of a beating porcine heart in vivo. The devices sample with simultaneous submillimeter and submillisecond resolution through 288 amplified and multiplexed channels. We use this system to map the spread of spontaneous and paced ventricular depolarization in real time, at high resolution, on the epicardial surface in a porcine animal model. This demonstration is one example of many possible uses of this technology in minimally invasive medical devices.


Asunto(s)
Electrofisiología Cardíaca/instrumentación , Electrónica/instrumentación , Silicio/química , Animales , Líquidos Corporales , Electricidad , Diseño de Equipo , Humanos , Modelos Animales , Monitoreo Fisiológico , Docilidad , Sus scrofa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA