RESUMEN
We studied the penetration of raltegravir and HIV shedding in the genital tract among 14 HIV-1-infected women receiving a raltegravir-containing regimen who had <40 copies/ml blood plasma (BP) HIV RNA. None of the cervicovaginal fluid (CVF) samples showed detectable HIV RNA. Median raltegravir concentrations were 235 ng/ml in BP and 93 ng/ml in CVF, with a CVF/BP ratio of approximately 2.3. This good penetration of raltegravir may contribute to the control of viral replication in the female genital tract.
Asunto(s)
Síndrome de Inmunodeficiencia Adquirida/tratamiento farmacológico , Fármacos Anti-VIH/farmacocinética , Cuello del Útero/metabolismo , VIH-1 , Pirrolidinonas/farmacocinética , Vagina/metabolismo , Adulto , Femenino , Humanos , Persona de Mediana Edad , Raltegravir PotásicoRESUMEN
The worldwide demand for SARS-CoV-2 RT-PCR testing resulted in a shortage of diagnostic kits. RNA extraction step constitutes a major bottleneck to perform diagnostic. The aim of this study was to assess performances of different extraction-free SARS-CoV-2 RT-PCR assays compared to a reference RT-PCR assay. The panel of evaluation consisted of 94 samples: 69 positive and 25 negative for SARS-CoV-2 by reference RT-PCR. Three extraction-free RT-PCR assays were assessed: (i) PrimeDirect® Probe RT-qPCR Mix (Takara), (ii) PrimeScript®RT-PCR (Takara), and (iii) SARS-CoV-2 SANSURE®BIOTECH Novel Coronavirus (Sansure). The overall sensitivity of PrimeDirect, PrimeScript and Sansure assays was 55.1 %, 69.6 % and 69.6 %, respectively. The sensitivity increased among samples with Ct<30: 91.9 % (n = 34/37), 89.2 % (n = 33/37) and 94.6 % (n = 35/37) for PrimeDirect, PrimeScript and Sansure assays, respectively. The specificity was 88 %, 100 % and 100 % for PrimeDirect, PrimeScript and Sansure assays, respectively. In the present study, we showed a good sensitivity of extraction-free PCR assays, especially for high viral loads (Ct<30), except PrimeDirect that displayed imperfect sensitivity and specificity. Despite a lower sensitivity for low viral loads, extraction-free reagents can provide a valuable option, cheaper, easier and less reagent consuming for SARS-CoV-2 diagnostic, especially in laboratory with lower experience and equipment for molecular assays.
Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , COVID-19/virología , Técnicas de Laboratorio Clínico/métodos , ARN Viral/genética , Juego de Reactivos para Diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sensibilidad y Especificidad , Carga ViralRESUMEN
BACKGROUND: This study aimed to assess, by rapid tests, the immune status against COVID-19 among Healthcare Workers (HCW) with history of symptoms, and for whom SARS-CoV-2 detection was either not documented or negative. METHODS: Whole blood by finger prick and serum samples were taken from HCW for use with 2 rapid lateral flow tests and an automated immunoassay. RESULTS: Seventy-two HCWs were included, median duration between symptoms onset and serology sampling was 68 days. Anti-SARS-CoV-2 antibodies were detected by rapid test in 11 HCW (15.3%) and confirmed in the 10 with available serum by the automated immunoassay. The frequency of ageusia or anosmia was higher in participants with SARS-CoV-2 antibodies (P = 0.0006 and P = 0.029, respectively). CONCLUSIONS: This study, among symptomatic HCW during the first wave in France, showed that 15% had IgG anti-SARS-CoV-2, a higher seroprevalence than in the general population. Rapid lateral flow tests were highly concordant with automated immunoassay.
Asunto(s)
Prueba Serológica para COVID-19 , COVID-19/diagnóstico , Personal de Salud , Pruebas en el Punto de Atención , SARS-CoV-2/aislamiento & purificación , Adulto , Anticuerpos Antivirales/sangre , COVID-19/sangre , Femenino , Humanos , Inmunoensayo , Masculino , Persona de Mediana Edad , Paris/epidemiología , Proyectos Piloto , Estudios Prospectivos , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Estudios SeroepidemiológicosRESUMEN
BACKGROUND: The use of efficient, reliable and sensitive PCR assays is a cornerstone in the race to contain the SARS-CoV-2 pandemic. In this work we performed an independent evaluation of the RealStar® SARS-CoV-2 RT-PCR Kit Researh Use Only (Altona) for SARS-CoV-2 detection. METHODS: A comparative limit of detection (LoD) assessment was performed between RealStar® SARS-CoV-2 and the currently WHO recommended RT-PCR (WHO-PCR) workflow using a quantified clinical sample. Assessment of the RealStar® SARS-CoV-2 assay was also performed using 83 primary clinical samples in comparison with the WHO-PCR. RESULTS: The RealStar® SARS-CoV-2 demonstrated a slightly higher sensitivity than the WHO recommended assay with a limit of detection at 625 copies/mL instead of 1250 copies/mL for the WHO-PCR in our conditions. The overall percent agreement between RealStar® SARS-CoV-2 and WHO-PCR on 83 clinical samples was 97.6 % (81/83) with a sensitivity at 97.8 % (45/46) and specificity at 97.3 % (36/37). No cross reaction was encountered for the other human coronaviruses (HKU1, OC43, NL63, 229E). CONCLUSIONS: In this comparison of the RealStar® SARS-CoV-2 assay with the reference WHO assay, we observed a slightly better sensitivity of the RealStar® assay. It provides a robust option for all molecular biology laboratories, with a strong real-life LoD and is compatible with various real-time PCR platforms.
Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Neumonía Viral/diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Humanos , Límite de Detección , Pandemias , SARS-CoV-2 , Sensibilidad y EspecificidadRESUMEN
The aim of this study was to assess the analytical performances, sensitivity and specificity, of two rapid tests (Covid- Presto® test rapid Covid-19 IgG/IgM and NG-Test® IgM-IgG COVID-19) and one automated immunoassay (Abbott SARS-CoV-2 IgG) for detecting anti- SARS-CoV-2 antibodies. This study was performed with: (i) a positive panel constituted of 88 SARS-CoV-2 specimens collected from patients with a positive SARS-CoV-2 RT-PCR, and (ii) a negative panel of 120 serum samples, all collected before November 2019, including 64 samples with a cross-reactivity panel. Sensitivity of Covid-Presto® test for IgM and IgG was 78.4% and 92.0%, respectively. Sensitivity of NG-Test® for IgM and IgG was 96.6% and 94.9%, respectively. Sensitivity of Abbott IgG assay was 96.5% showing an excellent agreement with the two rapid tests (κ = 0.947 and κ = 0.936 for NGTest ® and Covid-Presto® test, respectively). An excellent agreement was also observed between the two rapid tests (κ = 0.937). Specificity for IgM was 100% and 86.5% for Covid-Presto® test and NG-Test®, respectively. Specificity for IgG was 92.0%, 94.9% and 96.5% for Covid-Presto®, NGTest ®, and Abbott, respectively. Most of the false positive results observed with NG-Test® resulted from samples containing malarial antibodies. In conclusion, performances of these 2 rapid tests are very good and comparable to those obtained with automated immunoassay, except for IgM specificity with the NG-Test®. Thus, isolated IgM should be cautiously interpreted due to the possible false-positive reactions with this test. Finally, before their large use, the rapid tests must be reliably evaluated with adequate and large panel including early seroconversion and possible cross-reactive samples.
Asunto(s)
Anticuerpos Antivirales/sangre , Prueba de COVID-19/métodos , COVID-19/diagnóstico , Inmunoensayo/métodos , SARS-CoV-2/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Sensibilidad y EspecificidadRESUMEN
OBJECTIVES: Molecular assays on nasopharyngeal swabs remain the cornerstone of COVID-19 diagnostic. The high technicalities of nasopharyngeal sampling and molecular assays, as well as scarce resources of reagents, limit our testing capabilities. Several strategies failed, to date, to fully alleviate this testing process (e.g. saliva sampling or antigen testing on nasopharyngeal samples). We assessed the clinical performances of SARS-CoV-2 nucleocapsid antigen (N-antigen) ELISA detection in serum or plasma using the COVID-19 Quantigene® (AAZ, France) assay. METHODS: Performances were determined on 63 sera from 63 non-COVID patients and 227 serum samples (165 patients) from the French COVID and CoV-CONTACT cohorts with RT-PCR confirmed SARS-CoV-2 infection, including 142 serum (114 patients) obtained within 14 days after symptoms' onset. RESULTS: Specificity was 98.4% (95% confidence interval [CI], 95.3 to 100). Sensitivity was 79.3% overall (180/227, 95% CI, 74.0 to 84.6) and 93.0% (132/142, 95% CI, 88.7 to 97.2) within 14 days after symptoms onset. 91 included patients had a sera and nasopharyngeal swabs collected in the same 24 hours. Among those with high nasopharyngeal viral loads, i.e. Ct value below 30 and 33, only 1/50 and 4/67 tested negative for N-antigenemia, respectively. Among those with a negative nasopharyngeal RT-PCR, 8/12 presented positive N-antigenemia; the lower respiratory tract was explored for 6 of these 8 patients, showing positive RT-PCR in 5 cases. CONCLUSION: This is the first evaluation of a commercially available serum N-antigen detection assay. It presents a robust specificity and sensitivity within the first 14 days after symptoms onset. This approach provides a valuable new option for COVID-19 diagnosis, only requiring a blood draw and easily scalable in all clinical laboratories.
RESUMEN
BACKGROUND: New rapid influenza diagnostic tests (RIDT) are available but their clinical utility in adults has not been validated. OBJECTIVES: To evaluate the diagnostic performances of OSOM® Ultra Flu A&B a RIDT on viral strains of influenza A/B from the last epidemic season, and its feasibility by Emergency Department (ED) physicians and nurses. STUDY DESIGN: Of the 1099 patients admitted to the ED with suspected influenza, all having a nasopharyngeal swab tested by the Xpert® Flu PCR and then stored at -20⯰C; 500 were selected at random and their samples were tested using the RIDT. Two experts reviewed ED and hospital medical records and all virological data to define influenza cases. Intra- and inter-observer variability were calculated. RESULTS: Of the 500 patients included 45% were ≥75 years, 122 (24.4%) presented with influenza based on clinical and virological criteria. PCR test performances (%) were Se 98.4 (95% CI 93.6-99.7), Spe 99.7 (98.3-100), PPV 99.2 (94.8-100) and NPV 99.5 (97.9-100); and RIDT performances were Se 95.1 (89.2-97.9), Spe 98.4 (96.4-99.4), PPV 95.1 (87.2-99.9) and NPV 98.4 (96.4-98). There was no difference in test performance between influenza A and B virus nor between the influenza A subtypes. Intra- and inter-observer variability of RIDT were 0.94 (0.89-0.99) and 0.96 (0.92-1). CONCLUSION: Our results show that the Xpert® Flu PCR and the OSOM® Ultra Flu A&B Test perform very well in diagnosing strains of circulating virus in adults and elderly. Our results also confirm the feasibility of this RIDT at point-of-care by ED staff.
Asunto(s)
Inmunoensayo/normas , Virus de la Influenza A/aislamiento & purificación , Virus de la Influenza B/aislamiento & purificación , Gripe Humana/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa/métodos , Adulto , Anciano , Pruebas Diagnósticas de Rutina , Servicio de Urgencia en Hospital , Francia/epidemiología , Humanos , Gripe Humana/epidemiología , Persona de Mediana Edad , Técnicas de Diagnóstico Molecular/normas , Nasofaringe/virología , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
BACKGROUND: To date, only influenza and RSV testing are recommended for respiratory viruses' detection in paediatric units. In this study, we described, according to seasons, ages and clinical units, the results obtained in children (<15 years old) by multiplex-PCR (mPCR) tests allowing a quick and wide range detection of all respiratory viruses. These results were also compared with RSV specific detection. METHODS: All nasopharyngeal mPCR and RSV tests requested by clinicians in our French teaching hospitals group between 2011 and 2014 were retrospectively included. All repeated samples for the same children in the same month were discarded. RESULTS: Of the 381 mPCR tests (344 children) performed, 51.4% were positive. Positivity and viral co-infection rates were higher in the 6-36 months old strata (81% and 25%, p<0.0001 and p = 0.04, respectively). Viral distribution showed strong variations across ages. During specific influenza epidemic periods, only 1/39 (2.5%) mPCR tests were positive for influenza and 19/39 (48.7%) for other viruses. During specific RSV epidemic periods, only 8/46 (17.4%) mPCR tests were positive for RSV and 14/46 (30.4%) for other viruses. 477/1529 (31.2%) of RSV immunochromatography-tests were positive. Among the negatives immunochromatography-test also explored by mPCR, 28/62 (31%) were positive for other respiratory viruses. CONCLUSION: This study provides a wide description of respiratory viruses' distribution among children in hospital settings using mPCR over 3 years. It emphasizes the number of undiagnosed respiratory viruses according to the current diagnosis practice in France and gives a better picture of respiratory viruses identified in hospital settings by mPCR all over the year in France.
Asunto(s)
Reacción en Cadena de la Polimerasa Multiplex/métodos , Infecciones del Sistema Respiratorio/diagnóstico , Infecciones del Sistema Respiratorio/virología , Virosis/diagnóstico , Adolescente , Niño , Preescolar , Femenino , Francia , Humanos , Lactante , Masculino , Nasofaringe/virología , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Virus Sincitiales Respiratorios/aislamiento & purificación , Estudios Retrospectivos , Estaciones del AñoRESUMEN
BACKGROUND: Atazanavir/ritonavir (ATV/r) is a boosted protease inhibitor recommended to minimize the risk of mother-to-child HIV-1 transmission (MTCT). We aimed to assess the pharmacokinetics, safety and efficacy of ATV/r in HIV-1-infected pregnant women and their neonates. METHODS: A multicentre, cross-sectional, non-interventional cohort of HIV-1-infected pregnant women receiving ATV/r (300/100 mg once daily) who delivered in three Paris hospitals from 2006 to 2013 was designed. We determined antiretroviral trough plasma concentrations using liquid chromatography-mass spectrometry at each of the three trimesters, delivery and post-partum. ATV concentrations at 24 h (C24h) were interpreted by the 150-850 ng/ml efficacy-tolerance thresholds. Safety data and newborn HIV status were recorded. A mother's virological failure was defined as two successive measurements of plasma HIV-1 RNA>50 copies/ml within the 2 months before delivery. RESULTS: 103 pregnant women were included, mostly from sub-Saharan Africa (88%). ATV C24h at each of the three trimesters and delivery remained similar to post-partum values. No dose adjustment was needed during pregnancy. The median plasma ratio of fetal/maternal ATV level was 0.19 (n=28). Only three patients showed two successive detectable viral loads but <400 copies/ml. Among 82 available newborn data, 16 were born preterm. Three in utero deaths occurred. Tolerance was good with one case of maternal grade 3 hyperbilirubinaemia, no cases in neonates at delivery and no clinically relevant adverse event. No case of MTCT was reported. CONCLUSIONS: In this population, an ATV/r-containing antiretroviral regimen demonstrated good pharmacokinetics, virological efficacy and safety. No significant impact of pregnancy on ATV C24h was found. No dose adjustment was required.