Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Magn Reson Med ; 81(2): 825-838, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30284730

RESUMEN

PURPOSE: Simultaneous brain and spinal cord functional MRI is emerging as a new tool to study the central nervous system but is challenging. Poor B0 homogeneity and small size of the spinal cord are principal obstacles to this nascent technology. Here we extend a dynamic shimming approach, first posed by Finsterbusch, by shimming per slice for both the brain and spinal cord. METHODS: We shim dynamically by a simple and fast optimization of linear field gradients and frequency offset separately for each slice in order to minimize off-resonance for both the brain and spinal cord. Simultaneous acquisition of brain and spinal cord fMRI is achieved with high spatial resolution in the spinal cord by means of an echo-planar RF pulse for reduced FOV. Brain slice acquisition is full FOV. RESULTS: T2*-weighted images of brain and spinal cord are acquired with high clarity and minimal observable image artifacts. Fist-clenching fMRI experiments reveal task-consistent activation in motor cortices, cerebellum, and C6-T1 spinal segments. CONCLUSIONS: High quality functional results are obtained for a sensory-motor task. Consistent activation in both the brain and spinal cord is observed at individual levels, not only at group level. Because reduced FOV excitation is applicable to any spinal cord section, future continuation of these methods holds great potential.


Asunto(s)
Tronco Encefálico/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética , Médula Espinal/diagnóstico por imagen , Algoritmos , Artefactos , Imagen Eco-Planar , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Distribución Normal
2.
Magn Reson Med ; 75(2): 817-22, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25809723

RESUMEN

PURPOSE: Imaging using reduced FOV excitation allows higher resolution or signal-to-noise ratio (SNR) per scan time but often requires long radiofrequency pulses. The goal of this study was to improve a recent reduced field of view (FOV) method that uses a second-order shim gradient to decrease pulse length and evaluate its use in functional MRI (fMRI) applications. THEORY AND METHODS: The method, which was initially limited to excite thin disc-shaped regions at the isocenter, was extended to excite thicker regions off the isocenter and produced accurate excitation profiles on a grid phantom. Visual stimulation fMRI scans were performed with full and reduced FOV. The resolution of the time series images and functional activation maps were assessed using the full-width half-maxima of the autocorrelation functions (FACFs) of the noise images and the activation map values, respectively. RESULTS: The resolution was higher in the reduced FOV time series images (4.1% ± 3.7% FACF reduction, P < 0.02) and functional activation maps (3.1% ± 3.4% FACF reduction, P < 0.01), but the SNR was lower (by 26.5% ± 16.9%). However, for a few subjects, the targeted region could not be localized to the reduced FOV due to the low Z2 gradient strength. CONCLUSION: The results of this study suggest that the proposed method is feasible, though it would benefit from a stronger gradient coil.


Asunto(s)
Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Humanos , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido
3.
Magn Reson Med ; 75(2): 709-17, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25753055

RESUMEN

PURPOSE: Simultaneous multislice (SMS) imaging is a powerful technique that can reduce image acquisition time for anatomical, functional, and diffusion weighted magnetic resonance imaging. At higher magnetic fields, such as 7 Tesla, increased radiofrequency (RF) field inhomogeneity, power deposition, and changes in relaxation parameters make SMS spin echo imaging challenging. We designed an adiabatic 180° Power Independent of Number of Slices (PINS) pulse and a matched-phase 90° PINS pulse to generate a SEmi-Adiabatic Matched-phase Spin echo (SEAMS) PINS sequence to address these issues. METHODS: We used the adiabatic Shinnar Le-Roux (SLR) algorithm to generate a 180° pulse. The SLR polynomials for the 180° pulse were then used to create a matched-phase 90° pulse. The pulses were sub-sampled to produce a SEAMS PINS pulse-pair and the performance of this pulse-pair was validated in phantoms and in vivo. RESULTS: Simulations as well as phantom and in vivo results, demonstrate multislice capability and improved B1 -insensitivity of the SEAMS PINS pulse-pair when operating at RF amplitudes of up to 40% above adiabatic threshold. CONCLUSION: The SEAMS PINS approach presented here achieves multislice spin echo profiles with improved B1 -insensitivity when compared with a conventional spin echo.


Asunto(s)
Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Voluntarios Sanos , Humanos , Fantasmas de Imagen , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA