Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Heart Vessels ; 39(1): 48-56, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37606754

RESUMEN

The cusp overlap technique allows greater visual separation between the basal annular plane and the conduction system and decreases the permanent pacemaker implantation rate. We assessed the impact of the cusp overlap technique on conduction disturbance and paravalvular leakage after transcatheter aortic valve replacement. A total of 97 patients underwent transfemoral transcatheter aortic valve replacement with self-expandable valves at our institution from November 2018 to January 2023. The mean age of the patients was 85 years, and 23% were male. The patients were divided into two groups: the cusp overlap technique group and the non-cusp overlap technique group. We compared the clinical results between the two groups. The 30-day permanent pacemaker implantation rate was similar between the two groups (cusp overlap technique: 6.3% vs. non-cusp overlap technique: 10.2%, p = 0.48). The rate of new-onset conduction disturbance was slightly lower in the cusp overlap than non-cusp overlap technique group (18.8% vs. 34.7%, respectively; p = 0.08). The implanted valve function was similar between the two groups, but the rate of trivial or less paravalvular leakage (PVL) was significantly higher in the cusp overlap technique group on echocardiography (69% vs. 45%, p = 0.02). On multidetector computed tomography, the implantation depth at the membranous septum was significantly shorter in the cusp overlap technique group (2.0 ± 2.3 vs. 2.9 ± 1.5 mm, p = 0.02). The degree of canting was slightly smaller in the cusp overlap technique group (1.0 ± 2.2 vs. 1.7 ± 1.9 mm, p = 0.07). The relative risk of PVL equal to or greater than mild was 1.76 times higher for valve implantation without the cusp overlap technique (adjusted odds ratio, 3.74; 95% confidence interval, 1.45-9.69; p < 0.01). Transcatheter aortic valve replacement using the cusp overlap technique is associated with an optimized implantation depth, leading to fewer conduction disturbances. Optimal deployment may also maximize the radial force of self-expanding valves to reduce paravalvular leakage.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada Multidetector , Trastorno del Sistema de Conducción Cardíaco , Resultado del Tratamiento , Diseño de Prótesis
2.
Tohoku J Exp Med ; 260(1): 87-92, 2023 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-36889738

RESUMEN

Phosphodiesterase type 5 (PDE5) inhibitors such as tadalafil, can improve cardiac output by increasing left ventricular preload; however, there are concerns that this can increase the risk of heart failure due to pulmonary congestion in patients with elevated left ventricular end-diastolic pressure. We encountered a case in which low dose tadalafil improved the hemodynamics of a 66-year-old male patient with dilated cardiomyopathy (DCM) with congestion and low cardiac output due to biventricular dysfunction. The patient received a cardiac resynchronization therapy defibrillator (CRT-D) and appropriate medical therapy for heart failure. During a hemodynamic evaluation after heart failure symptoms were alleviated, we attempted to increase the dose of renin-angiotensin-aldosterone system (RAAS) inhibitors, which contribute to low cardiac output, hypotension, and worsening of renal function. However, the administration of a low dose of tadalafil for the patient's benign prostatic hyperplasia allowed for the increase in the dose of RAAS inhibitors and markedly improved his subjective symptoms and hemodynamics. Because of the biventricular dysfunction in severe cases, we often experience further promotion of low cardiac output by standard treatments such as RAAS inhibitors, in which low doses of PDE5 inhibitors may be effective in maintaining biventricular linkage. PDE5 inhibitors may be effective in patients, who are not able to increase the dose of RAAS inhibitors due to low cardiac output.


Asunto(s)
Insuficiencia Cardíaca , Inhibidores de Fosfodiesterasa 5 , Masculino , Humanos , Anciano , Tadalafilo/uso terapéutico , Tadalafilo/farmacología , Inhibidores de Fosfodiesterasa 5/farmacología , Inhibidores de Fosfodiesterasa 5/uso terapéutico , Gasto Cardíaco Bajo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/tratamiento farmacológico , Hemodinámica
3.
Circ J ; 86(9): 1397-1408, 2022 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-35660701

RESUMEN

BACKGROUND: A polymer-free biolimus A9-coated stent (PF-BCS) may achieve better arterial healing than a durable polymer drug-eluting stent owing to its polymer-free feature.Methods and Results: This multicenter, prospective, observational study enrolled 105 patients (132 lesions) who underwent PF-BCS (51 patients, 71 lesions) or durable polymer everolimus-eluting stent (DP-EES, 54 patients, 61 lesions) implantation. Serial coronary angioscopy (CAS) and optical coherence tomography (OCT) examinations were performed at 1 and 12 months, and the serial vessel responses were compared between PF-BCS and DP-EES. The primary outcome measure was the incidence of subclinical intrastent thrombus on CAS. The secondary outcome measures were: adequate strut coverage (≥40 µm) on OCT and maximum yellow color grade on CAS. The incidence of thrombus was high at 1 month (100% vs. 93%, P=0.091), but decreased at 12 months (18% vs. 25%, P=0.56), without a significant difference between PF-BCS and DP-EES. The adequate strut coverage rate was significantly higher (84±14% vs. 69±22%, P<0.001) and yellow color was significantly less intense (P=0.012) at 12 months in PF-BCS than in DP-EES; however, they were not significantly different at 1 month (adequate strut coverage: 47±21% vs. 50±17%, P=0.40; yellow color: P=0.99). CONCLUSIONS: Although the thrombogenicity of PF-BCS was similar to that of DP-EES, the adequate coverage and plaque stabilization rates of PF-BCS were superior to those of DP-EES at 12 months.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Trombosis , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Everolimus , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/análogos & derivados , Resultado del Tratamiento
4.
Heart Vessels ; 36(7): 955-964, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33502572

RESUMEN

In Japan, a robotic-assisted PCI (R-PCI) system, the CorPath GRX System (Corindus Inc.), has been approved for clinical use in 2018, which is the first introduction of R-PCI into Japan. In this study, the clinical performance of the R-PCI system in the initial year at Kurume University Hospital was evaluated comparing with conventional manual PCI (M-PCI). A total of 30 R-PCI and 77 M-PCI procedures performed between April 2019 and March 2020, were retrospectively included. The primary outcome was the rate of clinical success defined as < 30% residual stenosis without in-hospital major adverse cardiovascular events (MACE). The secondary outcomes were fluoroscopy time, dose area product (DAP), amount of radiation exposure to operators and assistants, procedural time, and contrast volume. Propensity-matching technique was used to match each R-PCI lesion to the nearest M-PCI lesion without replacement. After propensity score matching, 30 R-PCI procedures in 28 patients and 37 M-PCI procedures in 35 patients were analyzed. Clinical success rate with R-PCI was favorable and comparable to M-PCI (93.3 vs. 94.6%, p = 0.97), without any in-hospital MACE. The operator radiation exposure was significantly lower in R-PCI (0 vs. 24.5 µSV, p < 0.0001). Radiation exposure to the patients was tended to be reduced by R-PCI (DAP: 77.6 vs. 100.2 Gycm2, p = 0.07). There were no statistically significant differences in radiation exposure to the assistant, fluoroscopy time, procedural time and contrast volume between the two groups (radiation exposure to the assistant: 10.5 vs. 10.0 µSV, p = 0.64, fluoroscopy time: 27.5 vs. 30.1 min, p = 0.55, procedural time: 72.4 vs. 61.6 min, p = 0.23, and contrast volume: 93.2 vs. 102.0 ml, p = 0.36). R-PCI in selected patients demonstrated favorable clinical outcomes with dramatical reduction of radiation exposure to operators.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Procedimientos Quirúrgicos Robotizados/instrumentación , Anciano , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Japón/epidemiología , Masculino , Puntaje de Propensión , Exposición a la Radiación/efectos adversos , Traumatismos por Radiación/epidemiología , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Estudios Retrospectivos , Medición de Riesgo/métodos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
6.
Heart Vessels ; 32(7): 823-832, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28116487

RESUMEN

Implantation of mammalian target of rapamycin (mTOR)-inhibitor drug-eluting stents (DESs) impairs coronary endothelial function. There are no known non-invasive biomarkers of coronary endothelial dysfunction. We aimed to assess the association between serum interleukin-1beta (IL-1ß) and coronary endothelial dysfunction in patients with mTOR-inhibitor DES implantation and to investigate the association between the mTOR pathway and IL-1ß. We enrolled 35 patients who had implanted DESs for coronary artery disease. At a 10-month follow-up, peripheral venous blood samples were collected to measure IL-1ß levels. Coronary endothelial dysfunction was evaluated by intracoronary infusion of incremental doses of acetylcholine. Serum IL-1ß levels were significantly associated with the magnitude of vasoconstriction to acetylcholine at the segment distal (P < 0.05) but not proximal to the stent. Serum IL-1ß levels were positively correlated with stent length (P < 0.05). To examine the direct effects of mTOR inhibition on IL-1ß release, sirolimus was incubated in cultured human umbilical vein endothelial cells (HUVECs) or coronary artery smooth muscle cells (CASMCs). Sirolimus directly increased IL-1ß mRNA expression (P < 0.01) and enhanced IL-1ß release into the culture media (P < 0.01) in CASMCs, but not in HUVECs. Inhibition of mTOR triggers IL-1ß release through transcriptional activation in CASMCs. Serum IL-1ß levels are a potential biomarker for mTOR-inhibitor DES-associated coronary endothelial dysfunction.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Stents Liberadores de Fármacos/efectos adversos , Endotelio Vascular/patología , Interleucina-1beta/sangre , Anciano , Biomarcadores/sangre , Enfermedad de la Arteria Coronaria/terapia , Endotelio Vascular/efectos de los fármacos , Femenino , Humanos , Japón , Modelos Lineales , Masculino , Intervención Coronaria Percutánea , Sirolimus/farmacología , Serina-Treonina Quinasas TOR/antagonistas & inhibidores , Vasoconstricción/efectos de los fármacos
7.
Oxf Med Case Reports ; 2024(7): omae065, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38989505

RESUMEN

This report discusses a rare case of delayed migration of a Sapien 3 Ultra Resilia (S3UR) valve following transcatheter aortic valve implantation. An 81-year-old Japanese woman had a borderline aortic annular size of 20-23 mm according to the manufacturer's size chart. We chose to implant a smaller S3UR of 20 mm with an 80/20 depth ratio to allow for a second intervention, ensuring good hemodynamics and minimizing paravalvular leak. The patient initially had a favorable outcome despite an accidental 50/50 depth ratio during implantation. On postoperative day 3, the S3UR migrated into the left ventricular outflow tract. Emergency surgical aortic valve replacement was performed to retrieve the migrated valve. Use of the S3UR has led to a growing preference for smaller valve sizes. However, the risk of migration should be recognized. When an accidental 50/50 depth ratio implantation is encountered, post-dilation or second valve implantation should be performed immediately.

8.
J Cardiol ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38641319

RESUMEN

BACKGROUND: The relationship between baseline yellow plaque (YP) and vascular response after stent implantation has not been fully investigated. METHODS: This was a sub-analysis of the Collaboration-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention were analyzed. Optical coherence tomography (OCT) and coronary angioscopy (CAS) were serially performed immediately and 11 months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. OCT and CAS findings at 11 months were compared between lesions with baseline YP (YP group) and lesions without baseline YP (Non-YP group). RESULTS: Baseline YP was detected in 37 lesions (42 %). OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in the YP group (11 % versus 0 %, p = 0.028) and mean neointimal thickness tended to be lower (104 ±â€¯43 µm versus 120 ±â€¯48 µm, p = 0.098). CAS findings at 11 months demonstrated that the dominant and minimum neointimal coverage grades were significantly lower (p = 0.049 and P = 0.026) and maximum yellow color grade was significantly higher (p < 0.001) in the YP group. CONCLUSIONS: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation.

9.
J Cardiol Cases ; 27(6): 287-289, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37283910

RESUMEN

Yacoub operation, aimed at valve-sparing aortic root replacement, is performed to treat aortic root aneurysm with aortic regurgitation. Here we first report a successful transcatheter aortic valve implantation with a balloon-expandable prosthetic valve in an elderly patient having severe aortic valve stenosis and a small sinus of Valsalva 17 years after the Yacoub operation. Learning objectives: In transcatheter aortic valve implantation (TAVI) for aortic valve stenosis with a small sinus of Valsalva post-Yacoub operation, the use of a balloon-expandable prosthetic valve may be desirable for the TAVI; a detailed analysis of the anatomy of the valve-sparing aortic root with computed tomography is essential for the valve selection.

10.
Kurume Med J ; 68(2): 141-144, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37005291

RESUMEN

Vanishing tumor of the lung, also known as phantom tumor, is uncommonly observed in congestive heart failure. We report a case of a vanishing tumor that rapidly disappeared and reappeared in just a few minutes due to repositioning in a patient after open-heart surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Neoplasias Pulmonares , Humanos , Pulmón , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Neoplasias Pulmonares/cirugía
11.
Kurume Med J ; 68(2): 133-140, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37062727

RESUMEN

Ivabradine has been shown to improve heart failure with sinus tachycardia by reducing the heart rate without affecting left ventricular systolic function or blood pressure. Here we report a case of a catecholaminedependent patient, New York Heart Association (NYHA) class IV, LVEF of 18%, and low cardiac output, who was able to discontinue intravenous catecholamine by oral administration of ivabradine.


Asunto(s)
Gasto Cardíaco Bajo , Insuficiencia Cardíaca , Humanos , Ivabradina , Gasto Cardíaco Bajo/tratamiento farmacológico , Catecolaminas , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/tratamiento farmacológico , Frecuencia Cardíaca/fisiología
13.
Nutrients ; 13(8)2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34444823

RESUMEN

Background: Clinical characteristics of nutrition status in acute myocardial infarction (AMI) patients with cancer remains unknown. Therefore, this study aimed to clarify the differences of clinical parameters, including nutrition status, between AMI patients with and without history of cancer. Methods and Results: This retrospective cohort study, using the database of AMI between 2014 and 2019 in Kurume University Hospital, enrolled 411 patients; AMI patients without cancer (n = 358, 87.1%) and with cancer (n = 53, 12.9%). AMI patients with cancer were significantly older with lower body weight, worse renal function, and worse nutrition status. Next, we divided the patients into 4 groups by cancer, age, and plaque area, detected by coronary image devices. The prediction model indicated that nutrition, lipid, and renal functions were significant predictors of AMI with cancer. The ordinal logistic regression model revealed that worse nutrition status, renal dysfunction, lower uric acid, and elevated blood pressure were significant predictors. Finally, we were able to calculate the probability of the presence of cancer, by combining each factor and scoring. Conclusions: Worse nutrition status and renal dysfunction were associated with AMI with cancer, in which nutrition status was a major different characteristic from those without cancer.


Asunto(s)
Riñón/fisiología , Infarto del Miocardio/complicaciones , Estado Nutricional , Anciano , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Neoplasias/complicaciones , Estudios Retrospectivos , Ácido Úrico
14.
J Cardiol ; 75(3): 250-254, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31455545

RESUMEN

BACKGROUND: Peripheral arterial disease (PAD) frequently coexists with coronary artery disease (CAD). The ankle-brachial index (ABI) is widely used for the screening for PAD. Low ABI is associated with short-term clinical outcomes in patients receiving coronary drug-eluting stent (DES) implantation. However, there is no report to examine the relationship between lower ABI and long-term clinical outcomes after DES implantation. Thus, we investigated the clinical long-term impact of low ABI after DES implantation. METHODS: This retrospective analysis included 181 CAD patients treated with DES from April 2010 to March 2013 in our institute. Based on ABI values, we divided the subjects into the low-ABI group (ABI<0.9, n=29) and the normal ABI group (0.9≤ABI<1.4, n=152). The incidence of target lesion revascularization (TLR), all-cause mortality, and major adverse cardiac and cerebrovascular events (MACCE) defined as a composite of cardiac death, myocardial infarction, stroke, and any repeat revascularization, were compared between the 2 groups. RESULTS: During the median follow-up period of 43 months, the incidences of TLR, all-cause mortality, and MACCE were significantly higher in the low ABI group than in the normal ABI group (TLR: 41.4% vs 9.9%, p<0.001, all-cause mortality: 31.0% vs 3.9%, p<0.001, MACCE: 48.3% vs 11.2%, p<0.001, respectively). CONCLUSIONS: Low ABI may predict poor long-term outcomes, including TLR, in CAD patients treated with DES.


Asunto(s)
Índice Tobillo Braquial , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
16.
Kurume Med J ; 63(1.2): 39-43, 2017 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-28163269

RESUMEN

A 73-year-old woman with arteriosclerosis obliterans (ASO) was underwent a crossover stenting for an aortoiliac bifurcation from the right common iliac artery (CIA) with a self-expandable bare-metal stent (SE-BMS); however, a new stenosis later occurred just behind the bifurcation of the left CIA. An ex vivo experiment demonstrated that culotte-stenting by additional implantation of a balloon-expandable bare-metal stent (BE-BMS) through stent struts of the SE-BMS would be empirically infeasible. Although we had initially planned a T-stenting for the additional implantation of a BE-BMS in the left CIA, we finally deployed the stent in the CIA with the proximal end protruding into the previously-implanted SE-BMS through the stent struts to avoid incomplete coverage of the stenosis by reference to the ex vivo experiments. The patient has had no recurrence for 36 months.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Constricción Patológica/cirugía , Angiografía Coronaria/métodos , Stents Liberadores de Fármacos , Anciano , Angiografía , Aorta/cirugía , Arteriosclerosis Obliterante/diagnóstico , Arteriosclerosis Obliterante/cirugía , Femenino , Humanos , Arteria Ilíaca/cirugía , Resultado del Tratamiento
17.
Int J Cardiol Heart Vasc ; 17: 30-32, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29159269

RESUMEN

BACKGROUND: Unresolved thromboemboli in the pulmonary arteries (PA) is known to cause chronic thromboembolic pulmonary hypertension (CTEPH). However, it remains unknown if vascular dysfunction in pulmonary arteries exists in patients with CTEPH. METHODS AND RESULTS: We enrolled 7 female patients with CTEPH in this study, who have stable pulmonary hemodynamics after balloon pulmonary angioplasty (age; 73.6 ± 3.0 years old, mean right atrial pressure; 4.1 ± 0.4 mm Hg, mean pulmonary arterial pressure; 29.4 ± 2.7, mean pulmonary artery wedge pressure; 8.1 ± 1.2, pulmonary vascular resistance; 397.3 ± 51.7 dynes, cardiac index; 3.1 ± 0.2 L/min/m2). Pulmonary artery vascular function was evaluated by measuring pulmonary artery vasomotion in response to acetylcholine (Ach) at 10-month follow-up after balloon pulmonary angioplasty. All pulmonary vasoactive drugs were discontinued on the day of the procedures. The endothelium-dependent vasomotor response was evaluated by intra-pulmonary artery infusion of Ach at the dose of 10- 8 mol/l, and the vaso-spastic response was at 10- 6 mol/l. We evaluated vasomotor responses at the same segment in each patient, by measuring % changes of luminal area detected by quantitative pulmonary arterial optical frequency-domain imaging (OFDI), where OFDI catheter was fixed during the procedure. Endothelial dysfunction was observed at the dose of Ach at 10- 8 mol/l and vasoconstriction was also confirmed at the dose of Ach at 10- 6 mol/l in the diseased pulmonary arteries in CTEPH. CONCLUSIONS: These results indicated that the pulmonary artery dysfunction exists in patients with CTEPH, which may be involved in the pathogenesis and progression of CTEPH.

18.
Kurume Med J ; 63(1.2): 33-37, 2017 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-28090005

RESUMEN

Because of the protective effect of estrogen for atherosclerosis, the prevalence of acute coronary syndrome in women before menopause is low. We report a rare case of unstable angina in a young Japanese female who had a history of cigarette smoking and contraceptive use. Her coronary stenosis was successfully treated by percutaneous coronary intervention.


Asunto(s)
Angina Inestable/diagnóstico , Intervención Coronaria Percutánea/métodos , Angina Inestable/cirugía , Anticonceptivos Orales/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Japón , Fumar , Adulto Joven
20.
Cardiovasc Interv Ther ; 31(1): 21-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26113198

RESUMEN

Several studies have shown coronary endothelial dysfunction and delayed arterial healing associated with first-generation drug-eluting stents. However, it remains unclear whether those issues persist for a longer term. We thus evaluated serial changes in endothelial function and intra-stent condition after paclitaxel-eluting stents (PES) implantation. Eight patients with stable effort angina were assessed at 9 and over 24 months (1st and 2nd follow-up) after PES implantation. Endothelial function was evaluated with intracoronary infusion of acetylcholine (Ach). Vascular responses were quantitatively measured. Intra-stent condition was evaluated using angioscopy. We assessed (1) the degree of neointimal coverage over the stent (grade 0: no coverage to grade 3: full coverage); (2) presence of yellow intima inside the stent, and (3) existence of in-stent thrombus. Vasomotions proximal to the stent at 2nd follow-up significantly improved compared with 1st follow-up (p = 0.04), whereas vascular responses at the distal segment did not differ between 1st and 2nd follow-up (p = 0.19). From the angioscopic study, the average of coverage grading was comparable between the 2 points (0.9 ± 0.8 vs. 1.3 ± 1.0, p = 0.20). In addition, the incidence of yellow intima and in-stent thrombus did not differ between 1st and 2nd follow-up (yellow intima; 50 vs. 37.5 %, p = 1.0, thrombus; 75 vs. 50 %, p = 0.61). Endothelial dysfunction and delayed healing with PES could attenuate gradually, but these issues may persist over 24 months in some patients.


Asunto(s)
Vasos Coronarios/patología , Stents Liberadores de Fármacos , Endotelio Vascular/fisiopatología , Paclitaxel/administración & dosificación , Acetilcolina , Anciano , Angina Estable/terapia , Angioscopía , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Endotelio Vascular/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Nitroglicerina , Intervención Coronaria Percutánea , Túnica Íntima/patología , Vasodilatadores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA