Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Endovasc Ther ; : 15266028221134886, 2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36416475

RESUMEN

PURPOSE: The underlying difference between intermittent claudication (IC) and critical limb-threatening ischemia (CLTI) still remains unclear. This prospective multicenter observational study aimed to clarify differences in clinical features and prognostic outcomes between IC and CLTI, and prognostic factors in patients undergoing endovascular therapy (EVT). MATERIALS AND METHODS: A total of 692 patients with 808 limbs were enrolled from 20 institutions in Japan. The primary measurements were the 3-year rates of major adverse cardiovascular event (MACE) and reintervention. RESULTS: Among patients, 79.0% had IC and 21.0% had CLTI. Patients with CLTI were more frequently women and more likely to have impaired functional status, undernutrition, comorbidities, hypercoagulation, hyperinflammation, distal artery disease, short single antiplatelet and long anticoagulation therapies, and late cilostazol than patients with IC. Aortoiliac and femoropopliteal diseases were dominant in patients with IC and infrapopliteal disease was dominant in patients with CLTI. Patients with CLTI underwent less frequently aortoiliac intervention and more frequently infrapopliteal intervention than patients with IC. Longitudinal change of ankle-brachial index (ABI) exhibited different patterns between IC and CLTI (pinteraction=0.002), but ABI improved after EVT both in IC and in CLTI (p<0.001), which was sustained over time. Dorsal and plantar skin perfusion pressure in CLTI showed a similar improvement pattern (pinteraction=0.181). Distribution of Rutherford category improved both in IC and in CLTI (each p<0.001). Three-year MACE rates were 20.4% and 42.3% and 3-year reintervention rates were 22.1% and 46.8% for patients with IC and CLTI, respectively (log-rank p<0.001). Elevated D-dimer (p=0.001), age (p=0.043), impaired functional status (p=0.018), and end-stage renal disease (p=0.019) were independently associated with MACE. After considering competing risks of death and major amputation for reintervention, elevated erythrocyte sedimentation rate (p=0.003) and infrainguinal intervention (p=0.002) were independently associated with reintervention. Patients with CLTI merely showed borderline significance for MACE (adjusted hazard ratio 1.700, 95% confidence interval 0.950-3.042, p=0.074) and reintervention (adjusted hazard ratio 1.976, 95% confidence interval 0.999-3.909, p=0.05). CONCLUSIONS: The CLTI is characterized not only by more systemic comorbidities and distal disease but also by more inflammatory coagulation disorder compared with IC. Also, CLTI has approximately twice MACE and reintervention rates than IC, and the underlying inflammatory coagulation disorder per se is associated with these outcomes. CLINICAL IMPACT: The underlying difference between intermittent claudication (IC) and critical limb-threatening ischemia (CLTI) still remains unclear. This prospective multicenter observational study, JPASSION study found that CLTI was characterized not only by more systemic comorbidities and distal disease but also by more inflammatory coagulation disorder compared to IC. Also, CLTI had approximately twice major adverse cardiovascular event (MACE) and reintervention rates than IC. Intriguingly, the underlying inflammatory coagulation disorder per se was independently associated with MACE and reintervention. Further studies to clarify the role of anticoagulation and anti-inflammatory therapies will contribute to the development of post-interventional therapeutics in the context of peripheral artery disease.

2.
Exp Physiol ; 106(9): 1939-1949, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34216172

RESUMEN

NEW FINDINGS: What is the central question of this study? Arachidonic acid (AA) stimulates NO production in antral mucous cells without any increase in [Ca2+ ]i . Given that the intracellular AA concentration is too low to measure, the relationship between AA accumulation and NO production remains uncertain. Is AA accumulation a key step for NO production? What is the main finding and its importance? We demonstrated that AA accumulation is a key step for NO production. The amount of AA released could be measured using fluorescence-HPLC. The intracellular AA concentration was maintained at < 1 µM. Nitric oxide is produced by AA accumulation in antral mucous cells, not as a direct effect of [Ca2+ ]i . ABSTRACT: In the present study, we demonstrate that NO production is stimulated by an accumulation of arachidonic acid (AA) mediated via peroxisome proliferation-activated receptor α (PPARα) and that the NO produced enhances Ca2+ -regulated exocytosis in ACh-stimulated antral mucous cells. The amount of AA released from the antral mucosa, measured by fluorescence high-performance liquid chromatography (F-HPLC), was increased by addition of ionomycin (10 µM) or ACh, suggesting that AA accumulation is stimulated by an increase in [Ca2+ ]i . The AA production was inhibited by an inhibitor of cytosolic phospholipase A2 (cPLA2-inhα). GW6471 (a PPARα inhibitor) and cPLA2-inhα inhibited NO synthesis stimulated by ACh. Moreover, indomethacin, an inhibitor of cyclooxygenase, stimulated AA accumulation and NO production. However, acetylsalicylic acid did not stimulate AA production and NO synthesis. An analogue of AA (AACOCF3) alone stimulated NO synthesis, which was inhibited by GW6471. In antral mucous cells, indomethacin enhanced Ca2+ -regulated exocytosis by increasing NO via PPARα, and the enhancement was abolished by GW6471 and cPLA2-inhα. Thus, AA produced via PLA2 activation is the key step for NO synthesis in ACh-stimulated antral mucous cells and plays important roles in maintaining antral mucous secretion, especially in Ca2+ -regulated exocytosis.


Asunto(s)
Acetilcolina , Óxido Nítrico , Acetilcolina/farmacología , Ácido Araquidónico/farmacología , Calcio , Mucosa Gástrica , PPAR alfa/farmacología , Antro Pilórico
3.
Heart Vessels ; 34(8): 1297-1308, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30859377

RESUMEN

The appropriate stent platform for treating coronary bifurcation lesions (CBLs) remains controversial. Previous bench tests have demonstrated the superiority of a 2-link cell design to 3-link cell design for creating inter-strut dilation at the side branch ostium. This randomized multicenter prospective BEGIN trial compared the biodegradable polymer-based biolimus A9-eluting stent (2-link BES) with the durable polymer-based cobalt chromium everolimus-eluting stent (3-link EES) in 226 patients with de novo CBLs. Patients with true bifurcations, defined as > 50% stenosis in the main vessel and side branch (SB) and an SB diameter > 2.25 mm, were enrolled. Guide wire re-crossing to the distal cell (near the carina) in the jailed SB and final kissing inflation were recommended. The SB angiographic endpoint was < 50% stenosis diameter. Left-main CBLs (13.5% vs. 13.0%) and 2-stent technique (30.6% vs. 22.6%) rates were similar. The primary endpoints (minimum lumen diameter at the SB ostium measured at an independent core laboratory at the 8-month follow-up) were comparable (1.64 ± 0.50 mm vs. 1.63 ± 0.51 mm, p = 0.976). There was no significant difference in composite outcomes of cardiac death, myocardial infarction, or target vascular revascularization at 12 months (7.4% vs. 8.0%, p = 0.894). Two-link BES and 3-link EES showed similar 8-month angiographic and 1-year clinical outcomes for true CBLs.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea , Sirolimus/análogos & derivados , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Femenino , Humanos , Japón , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Polímeros/química , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
4.
Heart Vessels ; 31(12): 2061-2067, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27255645

RESUMEN

A 76-year-old woman with multiple coronary risk factors was admitted to our hospital because of episodes of new-onset chest pain that had begun 3 days previously. She underwent percutaneous coronary intervention (PCI) for severe stenoses in the two high lateral (HL) branches. Intravascular ultrasound (IVUS) revealed massive stenotic lesions in the HL branches and tumorous nonstenotic lesions in the left anterior descending coronary artery (LAD) and the left circumflex coronary artery (LCx). iMAP™, optical coherence tomography (OCT), and coronary computed tomography angiography (CCTA) were performed. iMAP depicted fibrosis in the vessel (green areas) and nonfibrotic tissue change suggestive of inflammation outside the vessel (yellow/red areas). OCT revealed high-intensity homogenous intimal hyperplasia with superficial calcification, and CCTA showed massive periarterial soft lesions in the HL, LAD, and LCx. The serum IgG4 level was high at 252-427 mg/dL (8 measurements) (reference range, 4.8-105.0 mg/dL). We suspected IgG4-related coronary periarteritis on the basis of the comprehensive diagnostic criteria as a possible diagnosis. The clinical course was good after initial and subsequent PCIs for both the HL stenoses and the progressing LCx stenosis, and there was no recurrence of angina pectoris thereafter. Steroids were not administered because the massive lesions did not enlarge during the 16 months of follow-up. iMAP was able to evaluate the tissue characteristics of tumorous lesions in the stenosed HL branches and the nonstenotic LAD and LCx in a patient with an elevated level of IgG4.


Asunto(s)
Arteritis/diagnóstico por imagen , Enfermedades Autoinmunes/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Inmunoglobulina G/sangre , Ultrasonografía Intervencional/métodos , Anciano , Angioplastia Coronaria con Balón , Arteritis/sangre , Arteritis/inmunología , Arteritis/terapia , Enfermedades Autoinmunes/sangre , Enfermedades Autoinmunes/inmunología , Enfermedades Autoinmunes/terapia , Biomarcadores/sangre , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/inmunología , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/sangre , Estenosis Coronaria/inmunología , Estenosis Coronaria/terapia , Femenino , Humanos , Valor Predictivo de las Pruebas , Tomografía de Coherencia Óptica , Resultado del Tratamiento
5.
Heart Vessels ; 31(11): 1752-1757, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26849831

RESUMEN

To evaluate the feasibility of catheter down sizing for QCA, the reliability of a 4Fr catheter as a calibration device was evaluated. Repeated coronary angiograms of 9 lesions were obtained using 4Fr and 6Fr catheters under otherwise identical conditions. The calibration factor was measured 10 times by 4Fr and 6Fr catheters. QCA measurements including minimal lumen diameter (MLD), interpolated normal reference (Int N), percent diameter stenosis (%DS), and lesion length (LL) were performed by two technicians twice with a 3-month interval. The intraobserver and interobserver variability of each parameter was evaluated using intraclass correlation coefficients (ICCs). Mean of mean SD of calibration factor was significantly larger in 4Fr than in 6Fr in 9 lesions. The mean of mean coefficient of variance was significantly larger in 4Fr catheters vs in 6Fr catheters. A 6Fr catheter showed excellent reliability for both intraobserver and interobserver variability in MLD, Int N, %DS, and LL. In contrast, 4Fr showed that reliability in intraobserver variability depended on the analyst. Although reliability of interobserver variability in Int N measured by the 4Fr catheter was >0.80, the value was less than that by the 6Fr catheter. Taking these results into consideration, 4Fr catheters are less reliable than 6Fr catheters when measuring QCA data especially for follow-up data that need most accurate measurements of MLD and %DS. It would be better to use a 6Fr catheter to evaluate QCA measurements such as acute gain, late loss, restenosis rate, and device size.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
6.
Heart Vessels ; 31(4): 465-73, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25630713

RESUMEN

Even in the drug-eluting stent era, diabetes mellitus (DM) patients have high incidences of restenosis and repeat revascularization after percutaneous coronary intervention. The aim of this study was to compare vascular response after stent implantation between sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES) by using optical coherence tomography (OCT) in DM patients as well as in non-DM patients. In the Japan-Drug Eluting Stents Evaluation; a Randomized Trial (J-DESsERT), the OCT sub-study enrolled 75 patients who underwent 8 months follow-up imaging after SES or PES implantation. Mean neointimal hyperplasia (NIH) thickness was significantly thinner in SES than PES in the DM group (77 ± 47 vs. 201 ± 114 µm, p < 0.001) and in the non-DM group (84 ± 37 vs. 212 ± 128 µm, p < 0.001). Unevenness of NIH thickness in longitudinal axis was significantly smaller in SES than PES in the DM group (348 ± 191 vs. 726 ± 385 µm, p < 0.001) and in the non-DM group (344 ± 174 vs. 679 ± 314 µm, p < 0.001). The percentage of uncovered struts was significantly greater in SES than PES in the DM group (24 ± 4 vs. 9 ± 14 %, p < 0.001) and in the non-DM group (16 ± 16 vs. 3 ± 4 %, p = 0.002). Compared with PES, SES showed more potent NIH inhibition in DM patients as well as in non-DM patients.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Tomografía de Coherencia Óptica/métodos , Grado de Desobstrucción Vascular/fisiología , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Neointima/patología , Estudios Prospectivos , Factores de Tiempo
7.
Heart Vessels ; 29(3): 413-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23812583

RESUMEN

In this case report, we describe the recovery of abnormal coronary pressure waveform using a PressureWire Certus during percutaneous coronary intervention in a patient with severe stenosis in the proximal segment of the left anterior descending coronary artery. Since the diastolic pressure in the distal left anterior descending coronary artery was lower than that in the aorta, the pressure waveform before percutaneous coronary intervention represented the left ventricular pressure through a fistula due to a "wedge effect" in the stenosis as if the pulmonary artery wedge pressure determined by a Swan-Ganz catheter reflected the pressure in the distal portion (left atrium). We diagnosed this case coronary artery-left ventricular fistula based on the above findings. PressureWire Certus may be a valuable tool with which to estimate the hemodynamics in a patient with a coronary anomaly.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Circulación Coronaria , Estenosis Coronaria/terapia , Anomalías de los Vasos Coronarios/diagnóstico , Vasos Coronarios/fisiopatología , Intervención Coronaria Percutánea , Fístula Vascular/diagnóstico , Anciano , Presión Sanguínea , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Anomalías de los Vasos Coronarios/fisiopatología , Diseño de Equipo , Humanos , Masculino , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Fístula Vascular/fisiopatología
8.
World J Cardiol ; 16(4): 173-176, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38690213

RESUMEN

Coronary artery anomaly is known as one of the causes of angina pectoris and sudden death and is an important clinical entity that cannot be overlooked. The incidence of coronary artery anomalies is as low as 1%-2% of the general population, even when the various types are combined. Coronary anomalies are practically challenging when the left and right coronary ostium are not found around their normal positions during coronary angiography with a catheter. If there is atherosclerotic stenosis of the coronary artery with an anomaly and percutaneous coronary intervention (PCI) is required, the suitability of the guiding catheter at the entrance and the adequate back up force of the guiding catheter are issues. The level of PCI risk itself should also be considered on a case-by-case basis. In this case, emission computed tomography in the R-1 subtype single coronary artery proved that ischemia occurred in an area where the coronary artery was not visible to the naked eye. Meticulous follow-up would be crucial, because sudden death may occur in single coronary arteries. To prevent atherosclerosis with full efforts is also important, as the authors indicated admirably.

9.
Am J Physiol Gastrointest Liver Physiol ; 304(9): G773-80, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23449671

RESUMEN

In antral mucous cells, acetylcholine (ACh, 1 µM) activates Ca(2+)-regulated exocytosis, consisting of an initial peak that declines rapidly (initial transient phase) followed by a second slower decline (late phase) lasting during ACh stimulation. The addition of 8-bromo-cGMP (8-BrcGMP) enhanced the initial phase, which was inhibited by the protein kinase G (PKG) inhibitor guanosine 3',5'-cyclic monophosphorothoiate, ß-phenyl-1,N(2)-etheno-8-bromo, Rp-isomer, sodium salt (Rp-8-BrPETcGMPS, 100 nM). However, Rp-8-BrPETcGMPS produced a delayed, but transient, increase in the exocytotic frequency during the late phase that was abolished by a protein kinase A (PKA) inhibitor (PKI-amide), suggesting that Rp-8-BrPETcGMPS accumulates cAMP. The cGMP-dependent phosphodiesterase 2 (PDE2), which degrades cAMP, may exist in antral mucous cells. The PDE2 inhibitor BAY-60-7550 (250 nM) mimicked the effect of Rp-8-BrPETcGMPS on ACh-stimulated exocytosis. Measurement of the cGMP and cAMP contents in antral mucosae revealed that ACh stimulates the accumulation of cGMP and that BAY-60-7550 accumulates cAMP similarly to Rp-8-BrPETcGMPS during ACh stimulation. Analyses of Western blot and immunohistochemistry demonstrated that PDE2A exists in antral mucous cells. In conclusion, Rp-8-BrPETcGMPS accumulates cAMP by inhibiting PDE2 in ACh-stimulated antral mucous cells, leading to the delayed, but transient, increase in the frequency of Ca(2+)-regulated exocytosis. PDE2 may prevent antral mucous cells from excessive mucin secretion caused by the cAMP accumulation.


Asunto(s)
Calcio/fisiología , AMP Cíclico/metabolismo , Proteínas Quinasas Dependientes de GMP Cíclico/antagonistas & inhibidores , GMP Cíclico/análogos & derivados , Exocitosis/efectos de los fármacos , Antro Pilórico/fisiología , Acetilcolina/farmacología , Animales , Proteínas Quinasas Dependientes de AMP Cíclico/antagonistas & inhibidores , GMP Cíclico/metabolismo , GMP Cíclico/farmacología , Fosfodiesterasas de Nucleótidos Cíclicos Tipo 2/antagonistas & inhibidores , Dinoprostona/metabolismo , Mucosa Gástrica/efectos de los fármacos , Cobayas , Masculino , Inhibidores de Proteínas Quinasas/farmacología , Antro Pilórico/efectos de los fármacos
10.
Int Heart J ; 53(6): 337-40, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23258132

RESUMEN

Even in the era of thrombus aspiration and distal protection for ST-segment elevation acute myocardial infarction (STEMI), microvascular dysfunction does exist and improvement of microvascular dysfunction can improve the prognosis and/or left ventricular dysfunction. We evaluated the acute effects of nitroprusside (NTP) on coronary microvascular injury that occurred after primary percutaneous coronary intervention (PCI) for STEMI in 18 patients. The final Thrombolysis in Myocardial Infarction trial (TIMI) flow grade after PCI was 3 in 17 patients and 2 in 1 patient. The index of microcirculatory resistance (IMR) was improved significantly from 76 ± 42 to 45 ± 37 (P = 0.0006) by intracoronary NTP administration. IMR improved to the normal range (IMR < 30) in 9 patients (50%). Higher TIMI flow grade and lower IMR at baseline were observed more frequently in patients whose IMR recovered to normal range after NTP administration. NTP improved the microcirculatory dysfunction at the acute phase in patients who underwent PCI for STEMI and had final TIMI 3 flow in almost all cases.


Asunto(s)
Circulación Coronaria/efectos de los fármacos , Electrocardiografía , Microcirculación/efectos de los fármacos , Infarto del Miocardio/terapia , Nitroprusiato/administración & dosificación , Intervención Coronaria Percutánea , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Vasos Coronarios , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intraarteriales , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/fisiopatología , Periodo Preoperatorio , Estudios Retrospectivos , Vasodilatadores/administración & dosificación
11.
Exp Physiol ; 95(7): 819-28, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20360425

RESUMEN

The ciliary beat frequency (CBF) of guinea-pig fimbria during the ovarian cycle was measured by video microscopy using a high-speed camera (500 Hz). In the follicular phase, with increasing concentrations of beta-oestradiol ([betaE(2)]) and a low concentration of progesterone ([PRG]), CBF increased from 13.5 to 16 Hz. In the ovulatory phase, with further increase of [betaE(2)], CBF decreased gradually from 16 to 13.5 Hz. In the early luteal phase, with low [PRG] and [betaE(2)], CBF increased to 17 Hz; however, in the middle luteal phase, with increasing [PRG], CBF decreased (12 Hz), and in the late luteal phase, with decreasing [PRG], CBF increased to 15 Hz. Then, in the resting phase, with low [betaE(2)] and [PRG], CBF decreased immediately to 14 Hz. The CBF of the fimbria was measured in guinea-pigs treated with beta-oestradiol benzoate (betaE(2)B) or medroxyprogesterone (mPRG). A low dose of betaE(2)B increased CBF to 14.5 Hz, whereas a high dose decreased it to 11 Hz. A betaE(2) receptor blocker, ICI-182,780, abolished the betaE(2)B-induced CBF changes and maintained CBF at 12.0 Hz. Medroxyprogesterone decreased CBF to 12.5 Hz, and mifepristone (a PRG receptor blocker) abolished the mPRG-induced CBF decrease and maintained CBF at 15 Hz. The addition of both blockers increased CBF to 18 Hz, suggesting that activation of betaE(2) or PRG receptors decreases the CBF of the fimbria. In conclusion, a moderate [betaE(2)] increase maintains a high CBF (15.5 Hz) in the follicular phase, and then further [betaE(2)] increase decreases CBF to 13.5 Hz in the ovulatory phase. In the early and late luteal phase, low [betaE(2)] and [PRG] increase CBF to 17 and 15 Hz, respectively, and in the middle luteal phase a high [PRG] decreases CBF (to 12 Hz). Thus, the CBF of the fimbria was controlled by signals via betaE(2) and PRG receptors in guinea-pigs.


Asunto(s)
Cilios/efectos de los fármacos , Cilios/fisiología , Estradiol/farmacología , Ciclo Estral/fisiología , Progesterona/farmacología , Animales , Estradiol/análogos & derivados , Ciclo Estral/efectos de los fármacos , Trompas Uterinas/fisiología , Femenino , Fulvestrant , Cobayas , Medroxiprogesterona/farmacología , Microscopía por Video , Mifepristona/farmacología , Ovulación/fisiología , Receptores de Estradiol/fisiología , Receptores de Progesterona/fisiología
12.
Catheter Cardiovasc Interv ; 76(2): 299-303, 2010 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-20665881

RESUMEN

We report a challenging case in terms of procedural difficulty as well as long-term patency. Multivessel stenting procedures for long subtotal occlusions in the right coronary artery (RCA) and left anterior descending coronary artery (LAD) were successfully performed in an 84-year-old female who had complications of severe left ventricular dysfunction and a recent history of gastric ulcer bleeding. Two bare-metal stents were successfully deployed in the mid and distal RCA. A drug-eluting stent could only be deployed in the proximal RCA. Two drug-eluting stents were deployed in the proximal LAD and LMT. Late stent thrombosis in the proximal RCA occurred about 3 months later. We speculated that a lack of aspirin and bare metal stent restenosis were the reasons for the late stent thrombosis. This case was very challenging in terms of balancing the risk of ischemia and bleeding after coronary stent deployment.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Stents , Trombosis/etiología , Anciano de 80 o más Años , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Femenino , Hemorragia/inducido químicamente , Humanos , Metales , Selección de Paciente , Inhibidores de Agregación Plaquetaria/efectos adversos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Trombosis/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento
13.
Hemoglobin ; 34(2): 151-6, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20353350

RESUMEN

We studied the structural environment surrounding the beta-N-terminal glycation site of a hemoglobin (Hb) molecule in which the proline residue at beta5(A2) was substituted by alanine in silico. By computer analysis that used Protein Data Bank data (PDB ID: 1BZ0), we tried to clarify the reason for impaired glycation of Hb Görwihl [beta5(A2)Pro-->Ala]. On the basis of the results, we predicted that the glycation site would have the following characteristics: 1) glycation of the beta-N-terminus of Hb is probably accelerated by the neighboring histidine residue at beta2(NA2), which acts as an acid-base catalyst via a phosphate-mediated proton transfer; and 2) the mutation beta5(A2)Pro-->Ala would bring about impaired glycation of the N-terminal residue by forming an electrostatic bond between the alpha amino group of beta1(NA1)Val and beta carboxyl group of beta79(EF3)Asp.


Asunto(s)
Hemoglobina Glucada/química , Hemoglobinas Anormales/metabolismo , Sustitución de Aminoácidos , Aminoácidos/química , Simulación por Computador , Glicosilación , Hemoglobinas Anormales/química , Humanos , Modelos Moleculares , Estructura Terciaria de Proteína , Protones , Electricidad Estática
14.
Ther Adv Cardiovasc Dis ; 14: 1753944720958982, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32993464

RESUMEN

AIM: To evaluate inter-core laboratory variability of quantitative coronary angiography (QCA) parameters in comparison with intra-core laboratory variability in a randomized controlled trial evaluating drug-eluting stents. METHODS: A total of 50 patients with 62 coronary lesions were analyzed by four analysis experts belonging to an Angiographic Core Laboratory (ACL: 1 expert) and a Cardiovascular Imaging Core Laboratory (CICL: 3 experts). QCA was based on the same standard operating procedure, but selections of projection and cine frames were at the discretion of each analyst. Inter- and intra-core laboratory variabilities were evaluated by accuracy, precision, Bland Altman analysis, and coefficient of variation. RESULTS: Pre-MLD (minimal lumen diameter) was significantly smaller in results from ACL than those from all CICL experts. Number of analyzed projections did not affect pre-MLD results. Acute gain was larger in ACL than in CICL2. No significant difference was observed in late loss and loss index between inter-core laboratories. Agreement between core labs in the Bland-Altman analysis for each QCA parameter was as follows (mean difference, 95% limits of agreement): pre-MLD (-0.32, -0.74 to 0.10), stent MLD (0.08, -0.28 to 0.44), acute gain (0.22, -0.44 to 0.88), and late loss (-0.07, -0.69 to 0.55). Agreement between analysts in CICL (mean difference, 95% limits of agreement) was: pre MLD (-0.03, -0.37 to 0.31), stent MLD (0.15, -0.15 to 0.45), acute gain (0.05, -0.45 to 0.55), and late loss (0.04, -0.52 to 0.60). The widest limits of agreement among three analyses were shown in both analyses. Width of limited agreement in the intra-core laboratory analysis tended to be smaller than the inter-core laboratory analysis with these parameters. Coefficient of variation tended to be larger in lesion length (LL), acute gain, late loss, and loss index in inter- and in intra- core laboratory comparisons. CONCLUSION: Inter-core laboratory QCA variability in late loss and loss index analysis could be similar to intra-core laboratory variability, but more strict alignment between core laboratories would be necessary for initial procedural data analysis.


Asunto(s)
Cineangiografía , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Anciano , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento
15.
World J Cardiol ; 11(7): 171-188, 2019 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-31565193

RESUMEN

Aerobic capacity, which is expressed as peak oxygen consumption (VO2peak), is well-known to be an independent predictor of all-cause mortality and cardiovascular prognosis. This is true even for people with various coronary risk factors and cardiovascular diseases. Although exercise training is the best method to improve VO2peak, the guidelines of most academic societies recommend 150 or 75 min of moderate- or vigorous- intensity physical activities, respectively, every week to gain health benefits. For general health and primary and secondary cardiovascular prevention, high-intensity interval training (HIIT) has been recognized as an efficient exercise protocol with short exercise sessions. Given the availability of the numerous HIIT protocols, which can be classified into aerobic HIIT and anaerobic HIIT [usually called sprint interval training (SIT)], professionals in health-related fields, including primary physicians and cardiologists, may find it confusing when trying to select an appropriate protocol for their patients. This review describes the classifications of aerobic HIIT and SIT, and their differences in terms of effects, target subjects, adaptability, working mechanisms, and safety. Understanding the HIIT protocols and adopting the correct type for each subject would lead to better improvements in VO2peak with higher adherence and less risk.

16.
Clin Med Insights Cardiol ; 13: 1179546819838232, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30967747

RESUMEN

We evaluated intra- and interobserver variability of quantitative coronary angiography (QCA) due to cine frame selection for 9 coronary stenoses. The projection was selected in advance. Cine frames were selected by 2 blinded experts (blind frame QCA) followed by assignment by supervisor (pre-selected frame QCA). Each expert analyzed 18 frames twice with a 3-month interval. A total of 72 measurements by 2 experts were used for intra- and interobserver variability analysis in calibration factor (CF), minimal lumen diameter (MLD), percent diameter stenosis (%DS), interpolated reference diameter (Int R), and lesion length (LL). Accuracy, precision, and coefficient of variation (CV) were calculated based on 2 measurements. For interobserver variability, intraclass correlation coefficient (ICC) was evaluated. Regarding intraobserver variability, precision (CV) was 0.0026 (1.45), 0.220 (25.1), 0.282 (11.0), 7.626 (11.8), and 4.042 (28.7) for blind frame QCA and 0.0044 (2.46), 0.094 (11.2), 0.225 (8.6), 3.924 (5.9), and 1.941 (12.1) for pre-selected frame QCA and regarding interobserver variability, precision (CV) was 0.0037 (2.09), 0.271 (31.8), 0.307 (11.9), 10.10 (15.4), and 5.121 (39.5) for blind frame QCA and 0.0050 (2.82), 0.098 (11.4), 0.246 (9.5), 5.253 (8.0), and 2.857 (19.0) for pre-selected frame QCA in CF, MLD, Int R, %DS, and LL, respectively. Intraclass correlation coefficient of Int R was almost perfect in blind and pre-selected frame QCA. Intraclass correlation coefficient of MLD, %DS, and LL were substantial/lower by blind frame QCA and improved to almost perfect by pre-selected frame QCA. Blind cine film selection might affect intra- and interobserver variability, especially in MLD and LL. In the multiple linear regression analysis, blind frame QCA was selected as an explanatory factor of QCA variability in MLD, %DS, and LL. The error range due to frame selection must be taken into consideration in clinical use.

18.
Cardiovasc Interv Ther ; 32(1): 72-76, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26660342

RESUMEN

A 63-year-old man with non-ST-elevation acute myocardial infarction had undergone PROMUS Element stent implantation for stenosis with thrombus in the left main trunk and the proximal left anterior descending artery. A 6-month follow-up angiography revealed no restenosis or stent thrombosis, but severe provoked spasms in three vessels, for which medications were administered. Three years later, the patient experienced new-onset rest angina one morning. Optical coherence tomography revealed subclinical very late stent thromboses inside and outside the stent. The patients experienced a severe spasm. Platelet function was adequately reduced, and the cytochrome P450 2C19 genotype indicated an extensive metabolizer phenotype. The spasm may have caused the thromboses.


Asunto(s)
Trombosis Coronaria/etiología , Vasoespasmo Coronario/etiología , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Everolimus/farmacología , Infarto del Miocardio sin Elevación del ST/cirugía , Intervención Coronaria Percutánea , Angiografía Coronaria , Trombosis Coronaria/diagnóstico , Vasoespasmo Coronario/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/diagnóstico
19.
Intern Med ; 56(11): 1351-1356, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28566597

RESUMEN

Intravascular images of coronary stenosis by antiphospholipid syndrome (APS) would be beneficial to understand the mechanism of this disease. A 59-year-old woman with APS/systemic lupus erythematosis (SLE) underwent emergent coronary angiography which revealed stenosis with micro channels in the proximal left anterior descending artery. According to optical coherence tomography (OCT), the central lumen was surrounded by a thick septum with a homogenous and high intensity. Multiple small channels existed near the vessel wall with diffuse intimal hyperplasia. White thrombi were floating distal to the stenosis. Intravascular images obtained by optical coherence tomography (OCT) revealed the microstructure of complex coronary stenosis, which had ambiguous findings on angiography and intravascular ultrasound (IVUS) in an acute coronary syndrome (ACS) patient with APS/SLE.


Asunto(s)
Síndrome Antifosfolípido/complicaciones , Síndrome Antifosfolípido/patología , Estenosis Coronaria/complicaciones , Estenosis Coronaria/patología , Síndrome Coronario Agudo/patología , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Humanos , Hiperplasia , Lupus Eritematoso Sistémico/complicaciones , Lupus Eritematoso Sistémico/patología , Persona de Mediana Edad , Tomografía de Coherencia Óptica , Túnica Íntima , Ultrasonografía Intervencional
20.
Heart Asia ; 9(2): e010934, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29469905

RESUMEN

OBJECTIVES: There have been limited data regarding the prediction of cardiac benefits after renal artery stenting for patients with atherosclerotic renal artery disease (ARAD). The aim of this multicentre retrospective study was to identify clinical or echocardiographic factors associated with improvements of cardiac symptoms after renal artery stenting. METHODS: We enrolled 58 patients with de novo ARAD undergoing successful renal artery stenting for heart failure, angina or both between January 2000 and August 2015 at 13 hospitals. RESULTS: Improvement of cardiac symptoms was observed in 86.2% of patients during a mean follow-up of 6.0±2.7 months. Responders demonstrated significantly lower New York Heart Association functional class, higher estimated glomerular filtration rate, lower serum creatinine and lower interventricular septal wall thickness (IVS), lower left ventricular mass index, lower left atrial dimension and lower E-velocity than non-responders. Backward stepwise multivariate analysis identified IVS as an independent predictor of improvement of cardiac symptoms (OR 0.451, 95% CI 0.209 to 0.976; p=0.043). According to receiver operating characteristic curve analysis, an IVS cut-off of 11.9 mm provided the best predictive value, with sensitivity of 71.4%, specificity of 75.5% and accuracy of 73.5%. The positive predictive value was 74.5% and the negative predictive value was 72.5%. CONCLUSIONS: This multicentre retrospective study shows that the echocardiographic index of IVS is an independent predictor for improvement of cardiac symptoms after renal artery stenting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA