Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
NMR Biomed ; : e5167, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38697612

RESUMEN

Susceptibility source separation, or χ-separation, estimates diamagnetic (χdia) and paramagnetic susceptibility (χpara) signals in the brain using local field and R2' (= R2* - R2) maps. Recently proposed R2*-based χ-separation methods allow for χ-separation using only multi-echo gradient echo (ME-GRE) data, eliminating the need for additional data acquisition for R2 mapping. Although this approach reduces scan time and enhances clinical utility, the impact of missing R2 information remains a subject of exploration. In this study, we evaluate the viability of two previously proposed R2*-based χ-separation methods as alternatives to their R2'-based counterparts: model-based R2*-χ-separation versus χ-separation and deep learning-based χ-sepnet-R2* versus χ-sepnet-R2'. Their performances are assessed in individuals with multiple sclerosis (MS), comparing them with their corresponding R2'-based counterparts (i.e., R2*-χ-separation vs. χ-separation and χ-sepnet-R2* vs. χ-sepnet-R2'). The evaluations encompass qualitative visual assessments by experienced neuroradiologists and quantitative analyses, including region of interest analyses and linear regression analyses. Qualitatively, R2*-χ-separation tends to report higher χpara and χdia values compared with χ-separation, leading to less distinct lesion contrasts, while χ-sepnet-R2* closely aligns with χ-sepnet-R2'. Quantitative analysis reveals a robust correlation between both R2*-based methods and their R2'-based counterparts (r ≥ 0.88). Specifically, in the whole-brain voxels, χ-sepnet-R2* exhibits higher correlation and better linearity than R2*-χ-separation (χdia/χpara from R2*-χ-separation: r = 0.88/0.90, slope = 0.79/0.86; χdia/χpara from χ-sepnet-R2*: r = 0.90/0.92, slope = 0.99/0.97). In MS lesions, both R2*-based methods display comparable correlation and linearity (χdia/χpara from R2*-χ-separation: r = 0.90/0.91, slope = 0.98/0.91; χdia/χpara from χ-sepnet-R2*: r = 0.88/0.88, slope = 0.91/0.95). Notably, χ-sepnet-R2* demonstrates negligible offsets, whereas R2*-χ-separation exhibits relatively large offsets (0.02 ppm in the whole brain and 0.01 ppm in the MS lesions), potentially indicating the false presence of myelin or iron in MS lesions. Overall, both R2*-based χ-separation methods demonstrated their viability as alternatives to their R2'-based counterparts. χ-sepnet-R2* showed better alignment with its R2'-based counterpart with minimal susceptibility offsets, compared with R2*-χ-separation that reported higher χpara and χdia values compared with R2'-based χ-separation.

2.
Eur Radiol ; 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38243135

RESUMEN

PURPOSE: To evaluate deep learning-based segmentation models for oropharyngeal squamous cell carcinoma (OPSCC) using CT and MRI with nnU-Net. METHODS: This single-center retrospective study included 91 patients with OPSCC. The patients were grouped into the development (n = 56), test 1 (n = 13), and test 2 (n = 22) cohorts. In the development cohort, OPSCC was manually segmented on CT, MR, and co-registered CT-MR images, which served as the ground truth. The multimodal and multichannel input images were then trained using a self-configuring nnU-Net. For evaluation metrics, dice similarity coefficient (DSC) and mean Hausdorff distance (HD) were calculated for test cohorts. Pearson's correlation and Bland-Altman analyses were performed between ground truth and prediction volumes. Intraclass correlation coefficients (ICCs) of radiomic features were calculated for reproducibility assessment. RESULTS: All models achieved robust segmentation performances with DSC of 0.64 ± 0.33 (CT), 0.67 ± 0.27 (MR), and 0.65 ± 0.29 (CT-MR) in test cohort 1 and 0.57 ± 0.31 (CT), 0.77 ± 0.08 (MR), and 0.73 ± 0.18 (CT-MR) in test cohort 2. No significant differences were found in DSC among the models. HD of CT-MR (1.57 ± 1.06 mm) and MR models (1.36 ± 0.61 mm) were significantly lower than that of the CT model (3.48 ± 5.0 mm) (p = 0.037 and p = 0.014, respectively). The correlation coefficients between the ground truth and prediction volumes for CT, MR, and CT-MR models were 0.88, 0.93, and 0.9, respectively. MR models demonstrated excellent mean ICCs of radiomic features (0.91-0.93). CONCLUSION: The self-configuring nnU-Net demonstrated reliable and accurate segmentation of OPSCC on CT and MRI. The multimodal CT-MR model showed promising results for the simultaneous segmentation on CT and MRI. CLINICAL RELEVANCE STATEMENT: Deep learning-based automatic detection and segmentation of oropharyngeal squamous cell carcinoma on pre-treatment CT and MRI would facilitate radiologic response assessment and radiotherapy planning. KEY POINTS: • The nnU-Net framework produced a reliable and accurate segmentation of OPSCC on CT and MRI. • MR and CT-MR models showed higher DSC and lower Hausdorff distance than the CT model. • Correlation coefficients between the ground truth and predicted segmentation volumes were high in all the three models.

3.
Radiology ; 307(1): e220941, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36413128

RESUMEN

Background Use of χ-separation imaging can provide surrogates for iron and myelin that relate closely to abnormal changes in multiple sclerosis (MS) lesions. Purpose To evaluate the appearances of MS and neuromyelitis optica spectrum disorder (NMOSD) brain lesions on χ-separation maps and explore their diagnostic value in differentiating the two diseases in comparison with previously reported diagnostic criteria. Materials and Methods This prospective study included individuals with MS or NMOSD who underwent χ-separation imaging from October 2017 to October 2020. Positive (χpos) and negative (χneg) susceptibility were estimated separately by using local frequency shifts and calculating R2' (R2' = R2* - R2). R2 mapping was performed with a machine learning approach. For each lesion, presence of the central vein sign (CVS) and paramagnetic rim sign (PRS) and signal characteristics on χneg and χpos maps were assessed and compared. For each participant, the proportion of lesions with CVS, PRS, and hypodiamagnetism was calculated. Diagnostic performances were assessed using receiver operating characteristic (ROC) curve analysis. Results A total of 32 participants with MS (mean age, 34 years ± 10 [SD]; 25 women, seven men) and 15 with NMOSD (mean age, 52 years ± 17; 14 women, one man) were evaluated, with a total of 611 MS and 225 NMOSD brain lesions. On the χneg maps, 80.2% (490 of 611) of MS lesions were categorized as hypodiamagnetic versus 13.8% (31 of 225) of NMOSD lesions (P < .001). Lesion appearances on the χpos maps showed no evidence of a difference between the two diseases. In per-participant analysis, participants with MS showed a higher proportion of hypodiamagnetic lesions (83%; IQR, 72-93) than those with NMOSD (6%; IQR, 0-14; P < .001). The proportion of hypodiamagnetic lesions achieved excellent diagnostic performance (area under the ROC curve, 0.96; 95% CI: 0.91, 1.00). Conclusion On χ-separation maps, multiple sclerosis (MS) lesions tend to be hypodiamagnetic, which can serve as an important hallmark to differentiate MS from neuromyelitis optica spectrum disorder. © RSNA, 2022 Supplemental material is available for this article.


Asunto(s)
Esclerosis Múltiple , Neuromielitis Óptica , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Neuromielitis Óptica/diagnóstico por imagen , Neuromielitis Óptica/patología , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Vaina de Mielina/patología
4.
NMR Biomed ; 36(7): e4901, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36632695

RESUMEN

The purpose of the current study was to develop spatially and velocity-selective (SVS) magnetization preparation pulses for noncontrast-enhanced peripheral MR angiography (MRA) to provide comparisons with velocity-selective (VS) MRA with comparison to velocity-selective (VS). VS preparation pulses were designed by concatenating multiple excitation steps, each of which was a combination of a hard RF pulse, VS unipolar gradient pulses, and refocusing RF pulses. SVS preparation pulses were designed by replacing the hard RF pulse with a sinc-shaped RF pulse combined with a symmetric tripolar gradient pulse (which does not perturb the velocity encoding by the VS unipolar gradient pulses). Numerical simulations were performed to verify the intended hybrid excitation selectivity of SVS pulses taking account of tissue relaxation, magnetic field errors, and eddy currents. In vivo experiments were performed in healthy subjects to verify the hybrid excitation selectivity, as well as to demonstrate the visualization of the entire peripheral arteries using six-station protocols. As demonstrated by numerical simulations, SVS preparation yielded a notch-shaped longitudinal magnetization (Mz )-velocity response within the spatial stopband (the same as VS preparation) and preserved the Mz of spins outside the stopband, regardless of its velocity. We confirmed these observations also through in vivo tests with good agreement in normalized arterial and muscle signal intensities. In six-station peripheral MRA experiments, the proposed SVS-MRA yielded significantly higher arterial signal-to-noise ratio (SNR) (51.6 ± 14.3 vs. 38.9 ± 10.9; p < 0.001) and contrast-to-noise ratio (CNR) (41.2 ± 13.0 vs. 31.3 ± 10.5; p < 0.001) compared with VS-MRA. The proposed SVS-MRA improves arterial SNR and CNR compared with VS-MRA by mitigating undesired presaturation of arterial blood upstream the imaging field of view.


Asunto(s)
Arterias , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Relación Señal-Ruido
5.
Eur Radiol ; 33(4): 2686-2698, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36378250

RESUMEN

OBJECTIVES: The study aimed to develop a deep neural network (DNN)-based noise reduction and image quality improvement by only using routine clinical scans and evaluate its performance in 3D high-resolution MRI. METHODS: This retrospective study included T1-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) images from 185 clinical scans: 135 for DNN training, 11 for DNN validation, 20 for qualitative evaluation, and 19 for quantitative evaluation. Additionally, 18 vessel wall imaging (VWI) data were included to evaluate generalization. In each scan of the DNN training set, two noise-independent images were generated from the k-space data, resulting in an input-label pair. 2.5D U-net architecture was utilized for the DNN model. Qualitative evaluation between conventional MP-RAGE and DNN-based MP-RAGE was performed by two radiologists in image quality, fine structure delineation, and lesion conspicuity. Quantitative evaluation was performed with full sampled data as a reference by measuring quantitative error metrics and volumetry at 7 different simulated noise levels. DNN application on VWI was evaluated by two radiologists in image quality. RESULTS: Our DNN-based MP-RAGE outperformed conventional MP-RAGE in all image quality parameters (average scores = 3.7 vs. 4.9, p < 0.001). In the quantitative evaluation, DNN showed better error metrics (p < 0.001) and comparable (p > 0.09) or better (p < 0.02) volumetry results than conventional MP-RAGE. DNN application to VWI also revealed improved image quality (3.5 vs. 4.6, p < 0.001). CONCLUSION: The proposed DNN model successfully denoises 3D MR image and improves its image quality by using routine clinical scans only. KEY POINTS: • Our deep learning framework successfully improved conventional 3D high-resolution MRI in all image quality parameters, fine structure delineation, and lesion conspicuity. • Compared to conventional MRI, the proposed deep neural network-based MRI revealed better quantitative error metrics and comparable or better volumetry results. • Deep neural network application to 3D MRI whose pulse sequences and parameters were different from the training data showed improvement in image quality, revealing the potential to generalize on various clinical MRI.


Asunto(s)
Aprendizaje Profundo , Humanos , Estudios Retrospectivos , Mejoramiento de la Calidad , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos
6.
Neuroimage ; 240: 118371, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34242783

RESUMEN

Obtaining a histological fingerprint from the in-vivo brain has been a long-standing target of magnetic resonance imaging (MRI). In particular, non-invasive imaging of iron and myelin, which are involved in normal brain functions and are histopathological hallmarks in neurodegenerative diseases, has practical utilities in neuroscience and medicine. Here, we propose a biophysical model that describes the individual contribution of paramagnetic (e.g., iron) and diamagnetic (e.g., myelin) susceptibility sources to the frequency shift and transverse relaxation of MRI signals. Using this model, we develop a method, χ-separation, that generates the voxel-wise distributions of the two sources. The method is validated using computer simulation and phantom experiments, and applied to ex-vivo and in-vivo brains. The results delineate the well-known histological features of iron and myelin in the specimen, healthy volunteers, and multiple sclerosis patients. This new technology may serve as a practical tool for exploring the microstructural information of the brain.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/metabolismo , Hierro/metabolismo , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/metabolismo , Vaina de Mielina/metabolismo , Adulto , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Neurológicos , Esclerosis Múltiple/diagnóstico por imagen , Adulto Joven
7.
NMR Biomed ; 34(10): e4571, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34129267

RESUMEN

MR images based on phase contrast images have gained clinical interest as an in vivo tool for assessing anatomical and histological findings. The globus pallidus is an area of major iron metabolism and storage in the brain tissue. Calcium, another important metal in the body, is frequently deposited in the globus pallidus as well. Recently, we observed dense paramagnetic deposition with paradoxical calcifications in the globus pallidus and putamen. In this work, we explore detailed MR findings on these structures, and the histological source of the related findings using ex vivo CT and MR images. Ex vivo MR was obtained with a maximum 100 µm3 isotropic resolution using a 15.2 T MR system. 3D gradient echo images and quantitative susceptibility mapping were used because of their good sensitivity to metallic deposition, high signal-to-noise ratio, and excellent contrast to iron and calcium. We found dense paramagnetic deposition along the perforating arteries in the globus pallidus. This paramagnetic deposition was hyperdense on ex vivo CT scans. Histological studies confirmed this finding, and simultaneous deposition of iron and calcium, although more iron dominant, was observed along the vessel walls of the globus pallidus. This was an exclusive finding for the penetrating arteries of the globus pallidus. Thus, our results suggest that several strong and paradoxical paramagnetic sources at the globus pallidus can be associated with vascular degeneration.


Asunto(s)
Calcinosis/diagnóstico por imagen , Globo Pálido/diagnóstico por imagen , Globo Pálido/patología , Imagen por Resonancia Magnética , Anciano , Ganglios Basales/diagnóstico por imagen , Ganglios Basales/patología , Femenino , Humanos , Masculino , Tomografía Computarizada por Rayos X
8.
Eur Radiol ; 31(2): 629-639, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32857205

RESUMEN

OBJECTIVES: Accurate preoperative localization of the intraparotid facial nerve (IFN) on MRI could reduce intraoperative injury. This study aimed to assess the detection rate of the IFN and its branches on MRI. METHODS: PubMed-MEDLINE and Embase databases were searched for articles published up to October 2019. The inclusion criteria were (a) adults, (b) MRI-based identification of IFN by radiologists, (c) original articles, and (d) detailed results to assess the proportion of visible IFN. Two radiologists reviewed the original articles. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to determine the quality of the selected studies. The DerSimonian-Laird random effects model was utilized to calculate the pooled estimates. Between-studies heterogeneity was evaluated using the chi-squared statistic test and Higgins' inconsistency index (I2). A subgroup meta-regression was performed to explore the factors causing study heterogeneity. RESULTS: Nine original articles with 209 subjects were included. MRI reported a high pooled detection rate of 99.8% (95% CI, 98.4-100%) for the main trunk of the IFN. The pooled rates for the temporofacial and cervicofacial branches were 90.4% (95% CI, 84.1-96.7%) and 96.3% (95% CI, 96.1-99.5%), respectively. Heterogeneity was detected only in the temporofacial branch (I2 = 83%) as a result of both slice thickness and the use of steady-state sequences with diffusion-weighted imaging (DWI) implementation. CONCLUSIONS: MRI showed an overall high detection rate of the IFN and its branches. Furthermore, an increased identification was observed in studies that used a slice thickness of < 1 mm and steady-state sequences with DWI implementation. KEY POINTS: • MRI showed an overall high detection rate of the intraparotid facial nerve and its branches. • Higher detection rate was observed in studies that used a slice thickness of < 1 mm and steady-state sequences with diffusion-weighted imaging.


Asunto(s)
Nervio Facial , Imagen por Resonancia Magnética , Adulto , Imagen de Difusión por Resonancia Magnética , Nervio Facial/diagnóstico por imagen , Humanos
9.
Eur Radiol ; 31(4): 2084-2093, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33006658

RESUMEN

OBJECTIVES: To evaluate the additional prognostic value of multiparametric MR-based radiomics in patients with glioblastoma when combined with conventional clinical and genetic prognostic factors. METHODS: In this single-center study, patients diagnosed with glioblastoma between October 2007 and December 2019 were retrospectively screened and grouped into training and test sets with a 7:3 distribution. Segmentations of glioblastoma using multiparametric MRI were performed automatically via a convolutional-neural network. Prognostic factors in the clinical model included age, sex, type of surgery/post-operative treatment, and tumor location; those in the genetic model included statuses of isocitrate dehydrogenase-1 mutation and O-6-methylguanine-DNA-methyltransferase promoter methylation. Univariate and multivariate Cox proportional hazards analyses were performed for overall survival (OS) and progression-free survival (PFS). Integrated time-dependent area under the curve (iAUC) for survival was calculated and compared between prognostic models via the bootstrapping method (performances were validated with prediction error curves). RESULTS: Overall, 120 patients were included (training set, 85; test set, 35). The mean OS and PFS were 25.5 and 18.6 months, respectively. The prognostic performances of multivariate models improved when radiomics was added to the clinical model (iAUC: OS, 0.62 to 0.73; PFS, 0.58 to 0.66), genetic model (iAUC: OS, 0.59 to 0.67; PFS, 0.59 to 0.65), and combined model (iAUC: OS, 0.65 to 0.73; PFS, 0.62 to 0.67). In the test set, the combined model (clinical, genetic, and radiomics) demonstrated robust validation for risk prediction of OS and PFS. CONCLUSIONS: Radiomics increased the prognostic value when combined with conventional clinical and genetic prognostic models for OS and PFS in glioblastoma patients. KEY POINTS: • CNN-based automatic segmentation of glioblastoma on multiparametric MRI was useful in extracting radiomic features. • Patients with glioblastoma with high-risk radiomics scores had poor overall survival (hazards ratio 8.33, p < 0.001) and progression-free survival (hazards ratio 3.76, p < 0.001). • MR-based radiomics improved the survival prediction when combined with clinical and genetic factors (overall and progression-free survival iAUC from 0.65 to 0.73 and 0.62 to 0.67, respectively; both p < 0.001).


Asunto(s)
Neoplasias Encefálicas , Glioblastoma , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/genética , Glioblastoma/diagnóstico por imagen , Glioblastoma/genética , Humanos , Imagen por Resonancia Magnética , Pronóstico , Estudios Retrospectivos
10.
Stroke ; 51(8): 2558-2562, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32586224

RESUMEN

BACKGROUND AND PURPOSE: Differentiation between pseudo-occlusion and true occlusion of internal carotid artery (ICA) is important in treatment planning for acute ischemic stroke patients. We compared the findings of multiphasic computed tomography angiography between cervical ICA pseudo-occlusion and true occlusion at the cervical ICA in patients with anterior circulation acute ischemic stroke to determine their diagnostic value. METHODS: Thirty patients with nonvisualization of the proximal ICA were included. Diagnosis of pseudo- or true occlusion of the ICA was made based on digital subtraction angiography. Diagnostic performances of multiphasic computed tomography angiography findings-(1) a flame-shaped stump and (2) delayed contrast filling at the cervical ICA- were evaluated and compared. The Fisher exact test, χ2 test, or Wilcoxon rank-sum test and McNemar test were used in the data analysis. RESULTS: Twelve patients had true proximal ICA occlusion and 18 had pseudo-occlusion. Delayed contrast filling at the cervical ICA on multiphasic computed tomography angiography was found in all patients with pseudo-occlusion of the ICA, while 1 case of true occlusion showed delayed contrast filling (P<0.001). The presence of a flame-shaped stump was not significantly different between the pseudo- and true occlusion groups. The sensitivity of delayed contrast filling (0.94 [95% CI, 0.73-1]) was significantly higher than that of flame-shaped stump (0.75 [95% CI, 0.36-0.83]). CONCLUSIONS: We demonstrated that the delayed filling sign on multiphasic computed tomography angiography could be a useful and readily available finding for differentiating proximal ICA pseudo-occlusion from true occlusion.


Asunto(s)
Arteria Carótida Interna/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/tendencias , Femenino , Humanos , Masculino , Estudios Retrospectivos
11.
Hum Brain Mapp ; 41(18): 5313-5324, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-32897599

RESUMEN

We investigated the narrow-sense heritability of MRI-visible dilated perivascular spaces (dPVS) in healthy young adult twins and nontwin siblings (138 monozygotic, 79 dizygotic twin pairs, and 133 nontwin sibling pairs; 28.7 ± 3.6 years) from the Human Connectome Project. dPVS volumes within basal ganglia (BGdPVS) and white matter (WMdPVS) were automatically calculated on three-dimensional T2-weighted MRI. In univariate analysis, heritability estimates of BGdPVS and WMdPVS after age and sex adjustment were 65.8% and 90.2%. In bivariate analysis, both BGdPVS and WMdPVS showed low to moderate genetic correlations (.30-.43) but high shared heritabilities (71.8-99.9%) with corresponding regional volumes, intracranial volumes, and other regional dPVS volumes. Older age was significantly associated with larger dPVS volume in both regions even after adjusting for clinical and volumetric variables, while blood pressure was not associated with dPVS volume although there was weak genetic correlation. dPVS volume, particularly WMdPVS, was highly heritable in healthy young adults, adding evidence of a substantial genetic contribution in dPVS development and differential effect by location. Age affects dPVS volume even in young adults, while blood pressure might have limited role in dPVS development in its normal range.


Asunto(s)
Ganglios Basales/anatomía & histología , Aprendizaje Profundo , Sistema Glinfático/anatomía & histología , Patrón de Herencia , Neuroimagen/métodos , Gemelos , Sustancia Blanca/anatomía & histología , Adulto , Factores de Edad , Ganglios Basales/diagnóstico por imagen , Femenino , Sistema Glinfático/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Retrospectivos , Hermanos , Sustancia Blanca/diagnóstico por imagen , Adulto Joven
12.
Radiology ; 297(1): 143-150, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32692298

RESUMEN

Background The relationship between administration of macrocyclic gadolinium-based contrast agents and T1-weighted signal intensity (SI) change of the globus pallidus (GP) and dentate nucleus (DN) is, to the knowledge of the authors, not known. Purpose To determine if quantitative susceptibility mapping (QSM) can detect changes in magnetic susceptibility of the GP and DN after serial administration of macrocyclic gadobutrol in patients with primary brain tumors. Materials and Methods Patients diagnosed with primary brain tumors from August 2014 to February 2019 were eligible for this single-center retrospective study. Among 501 consecutive adult patients who were given at least one administration of gadobutrol, those who were previously administered an unknown or linear gadolinium-based contrast agent were excluded. Brain MRI scans with three-dimensional gradient-recalled-echo image phase data for QSM processing were reviewed. Regions of interest were drawn on the GP and DN on the basis of semiautomatic thresholding. Univariable generalized estimation equations were used to determine the associations between MRI measures (SI on T1-weighted images and magnetic susceptibility on QSM) and number of gadobutrol doses. Potential confounding factors were adjusted for in multivariable generalized estimating equation. Results Ninety patients (mean age, 51 years ± 17 [standard deviation]; 51 men) with 199 MRI scans were analyzed. In models adjusted for repeated observations between injections, the number of injections of gadobutrol was associated with the magnetic susceptibility of the GP (1.4 × 10-3 ppm/number of gadobutrol injections; P = .01) and DN (8.1 × 10-4 ppm/number of gadobutrol injections; P = .03). After adjustment for confounders, the number of gadobutrol injections remained an independent predictor of increased magnetic susceptibility in the GP (1.3 × 10-3 ppm/number of gadobutrol injections; 95% confidence interval: 0.39 × 10-3, -2.4 × 10-3; P = .006). There were no associations between number of gadobutrol injections and SI or magnetic susceptibility in the DN. Conclusion The magnetic susceptibility of the globus pallidus increased after serial administration of gadobutrol. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Wang and Prince in this issue.


Asunto(s)
Mapeo Encefálico/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Imagen por Resonancia Magnética/métodos , Compuestos Organometálicos/administración & dosificación , Núcleos Cerebelosos/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Globo Pálido/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Estudios Longitudinales , Masculino , Persona de Mediana Edad
13.
Neuroradiology ; 62(12): 1617-1626, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32621024

RESUMEN

PURPOSE: This study aimed to comprehensively evaluate the diagnostic performance of dual-energy CT (DECT) for differentiating acute intracranial hemorrhage (ICH) from contrast staining or small calcifications via a systematic review and meta-analysis. METHODS: The PubMed-MEDLINE, EMBASE, and Cochrane Library databases were searched up to November 10, 2019. Original studies (prospective or retrospective cohort studies) with the primary aim of detecting ICH using DECT were selected. The diagnostic performance of DECT was assessed using bivariate and hierarchical summary receiver operating characteristic models. Quality assessment was performed according to the Quality Assessment of Diagnostic Accuracy Studies-2, while between-study heterogeneity was assessed using Higgins' inconsistency index (I2). To explore heterogeneity, subgroup meta-regression analyses were performed. Deeks' funnel plot asymmetry test was used for assessing publication bias. RESULTS: Nine studies comprising 402 patients with 453 lesions were included for data synthesis. The overall pooled sensitivity and specificity of DECT for ICH detection were 96% (95% CI, 77-99%) and 98% (95 CI, 93%-100%), respectively. Substantial and moderate between-study heterogeneities were observed for sensitivity (I2 = 90.3%) and specificity (I2 = 57.9%), respectively. In meta-regression analysis, type of cohort affected heterogeneity-studies including only stroke patients showed lower sensitivity (43.5% vs. 94.2%) but higher specificity (98.7% vs. 92.6%) than those with mixed etiologies (P < 0.001). Deeks' funnel plot asymmetry test revealed publication bias (P = 0.020). CONCLUSION: DECT demonstrated excellent diagnostic performance in terms of differentiating acute ICH from contrast staining and small calcifications. However, publication bias suggests the possibility of overestimated diagnostic performance, warranting large-scale, prospective cohort studies.


Asunto(s)
Hemorragias Intracraneales/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/diagnóstico por imagen , Medios de Contraste , Diagnóstico Diferencial , Humanos , Sensibilidad y Especificidad
14.
Int J Hyperthermia ; 37(1): 742-748, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33480816

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the usefulness of CT for quantitative assessment of the neck structures after RFA in patients with benign thyroid nodules. MATERIALS AND METHODS: This single-center, retrospective cohort study included 38 patients with benign thyroid nodules who had received RFA and had available pre- and post-treatment CT images. Changes in the tracheal anteroposterior (AP)/transverse diameter ratio, cross-sectional tracheal area, midline deviation of the trachea, and anterior neck angle after RFA were quantitatively measured using CT. Volume reduction rates (VRRs) for the thyroid gland and nodules were measured using CT and US, respectively, and the intraclass correlation coefficient (ICC) was calculated. The paired Wilcoxon signed-rank test was used to compare pre- and post-treatment CT-based measurements, and univariate linear regression analysis was performed to determine the association of VRR with the mean delivered radiofrequency energy, number of RFA sessions, and initial thyroid volume. RESULTS: After RFA, the tracheal AP/transverse diameter ratio and midline deviation were significantly decreased while the tracheal area and anterior neck angle were significantly increased (all, p < 0.001). The thyroid volume reduction was also significant (VRR, 42.1% ± 21.1%, p < 0.001), with moderate consistency between the CT-based thyroid VRR and US-based nodule VRR (ICC = 0.68, 95% confidence interval = 0.38-0.83, p < 0.001). The mean delivered radiofrequency energy (p = 0.565), number of RFA sessions (p = 0.209), and initial thyroid volume (p = 0.363) showed no significant association with VRR. CONCLUSION: CT-based quantitative assessments may be useful for evaluating improvements in the neck structures after RFA for benign thyroid nodules.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Nódulo Tiroideo , Estudios Transversales , Humanos , Estudios Retrospectivos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
J Korean Med Sci ; 35(42): e379, 2020 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140591

RESUMEN

In recent years, artificial intelligence (AI) technologies have greatly advanced and become a reality in many areas of our daily lives. In the health care field, numerous efforts are being made to implement the AI technology for practical medical treatments. With the rapid developments in machine learning algorithms and improvements in hardware performances, the AI technology is expected to play an important role in effectively analyzing and utilizing extensive amounts of health and medical data. However, the AI technology has various unique characteristics that are different from the existing health care technologies. Subsequently, there are a number of areas that need to be supplemented within the current health care system for the AI to be utilized more effectively and frequently in health care. In addition, the number of medical practitioners and public that accept AI in the health care is still low; moreover, there are various concerns regarding the safety and reliability of AI technology implementations. Therefore, this paper aims to introduce the current research and application status of AI technology in health care and discuss the issues that need to be resolved.


Asunto(s)
Inteligencia Artificial , Atención a la Salud , Regulación Gubernamental , Política de Salud , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Administración de la Seguridad , Tomografía Computarizada por Rayos X
16.
Neuroophthalmology ; 44(6): 387-390, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33335345

RESUMEN

Leber's hereditary optic neuropathy (LHON) is a mitochondrial genetic disease that leads to acute or subacute, painless, bilateral loss of vision, caused by degeneration of retinal ganglion cells that most affects men in their second or third decade of life. We describe a woman with compressive optic neuropathy with a concurrent LHON-associated mitochondrial mutation. Temporal hemifield defect connected to central scotoma and concurrent abduction limitation are diagnostic clues in identifying chiasmal compression with craniopharyngioma. This case emphasizes an awareness of the possible coexistence of compressive and hereditary optic neuropathy.

17.
J Magn Reson Imaging ; 50(5): 1413-1423, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-30884007

RESUMEN

BACKGROUND: FLAIR (fluid attenuated inversion recovery) imaging via synthetic MRI methods leads to artifacts in the brain, which can cause diagnostic limitations. The main sources of the artifacts are attributed to the partial volume effect and flow, which are difficult to correct by analytical modeling. In this study, a deep learning (DL)-based synthetic FLAIR method was developed, which does not require analytical modeling of the signal. PURPOSE: To correct artifacts in synthetic FLAIR using a DL method. STUDY TYPE: Retrospective. SUBJECTS: A total of 80 subjects with clinical indications (60.6 ± 16.7 years, 38 males, 42 females) were divided into three groups: a training set (56 subjects, 62.1 ± 14.8 years, 25 males, 31 females), a validation set (1 subject, 62 years, male), and the testing set (23 subjects, 57.3 ± 20.4 years, 13 males, 10 females). FIELD STRENGTH/SEQUENCE: 3 T MRI using a multiple-dynamic multiple-echo acquisition (MDME) sequence for synthetic MRI and a conventional FLAIR sequence. ASSESSMENT: Normalized root mean square (NRMSE) and structural similarity (SSIM) were computed for uncorrected synthetic FLAIR and DL-corrected FLAIR. In addition, three neuroradiologists scored the three FLAIR datasets blindly, evaluating image quality and artifacts for sulci/periventricular and intraventricular/cistern space regions. STATISTICAL TESTS: Pairwise Student's t-tests and a Wilcoxon test were performed. RESULTS: For quantitative assessment, NRMSE improved from 4.2% to 2.9% (P < 0.0001) and SSIM improved from 0.85 to 0.93 (P < 0.0001). Additionally, NRMSE values significantly improved from 1.58% to 1.26% (P < 0.001), 3.1% to 1.5% (P < 0.0001), and 2.7% to 1.4% (P < 0.0001) in white matter, gray matter, and cerebral spinal fluid (CSF) regions, respectively, when using DL-corrected FLAIR. For qualitative assessment, DL correction achieved improved overall quality, fewer artifacts in sulci and periventricular regions, and in intraventricular and cistern space regions. DATA CONCLUSION: The DL approach provides a promising method to correct artifacts in synthetic FLAIR. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1413-1423.


Asunto(s)
Artefactos , Encéfalo/diagnóstico por imagen , Aprendizaje Profundo , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
18.
Int J Hyperthermia ; 36(1): 359-367, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30836037

RESUMEN

PURPOSE: To compare the efficacy and complication rates of radiofrequency ablation (RFA) and repeat surgery in the treatment of locally recurrent thyroid cancers. MATERIALS AND METHODS: A total of 221 patients with locally recurrent thyroid cancers who underwent either RFA (n = 96) or repeat surgery (n = 125) between March 2008 and March 2017 were retrospectively enrolled (range of follow-up, 1-10 years). Each cohort consisted of 70 patients after propensity score adjustment. Patients with more than three recurrent lesions were excluded. The primary and secondary end points were recurrence-free survival and complication rates, respectively. Recurrence-free survival curves were compared via the log-rank test. The complications-voice changes, hypocalcemia, and immediate procedural complications-were compared between the groups. In addition, pretreatment serum thyroglobulin (Tg) levels and those at the last follow-up were also compared between the two groups to examine therapeutic efficacy. RESULTS: After propensity score matching, both groups showed no significant differences in baseline characteristics. The recurrence-free survival rates were comparable between the RFA and surgery groups (p = .2). There were no significant differences in mean serum Tg levels and their mean decrease after treatment between the groups (p = .891 and p = .963, respectively). Immediate procedural complications and voice changes also showed no significant between-group differences (p = .316, p = .084, respectively). Hypocalcemia occurred only in the repeat surgery group (n = 18). Overall complications were significantly more frequent in the repeat surgery group (RFA, n = 7; surgery, n = 27; p < .001). CONCLUSION: RFA may be an effective and safe alternative to repeat surgery in the treatment of a small number of locally recurrent thyroid cancers.


Asunto(s)
Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/métodos , Neoplasias de la Tiroides/radioterapia , Neoplasias de la Tiroides/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Estudios Retrospectivos
20.
BMC Pediatr ; 19(1): 121, 2019 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-31014304

RESUMEN

BACKGROUND: Despite significant advances in neonatology, bronchopulmonary dysplasia (BPD) remains the most common cause of serious morbidity and mortality in premature infants. The aim of the present study was to determine associations between the respiratory severity score (RSS) with death or BPD in premature infants. METHODS: This was a retrospective study conducted between January 2010 and December 2014. We enrolled preterm infants with a gestational age of less than 28 weeks who were supported by mechanical ventilation for more than a week during the first 4 weeks of life. We collected the RSS scores on day of life 2, 7, 14, 21 and 28. The correlations between postnatal RSSs and death or severe BPD were analyzed using multivariate logistic regression. RESULTS: Of the 138 eligible infants, 66 infants (47.8%) either died or developed severe BPD. The RSS cut-off values for predicting severe BPD or death were 3.0 for postnatal day (PND) 14 with an odds ratio (OR) of 11.265 (p = 0.0006, 95% confidence interval (CI), 2.842 to 44.646), 3.6 for PND 21 with an OR of 15.162 (p = 0.0003, 95% CI, 3.467 to 66.316), and 3.24 for PND 28 with an OR of 10.713 (p = 0.0005, 95% CI, 2.825 to 40.630). CONCLUSION: Strong correlations were observed between the RSSs on PND 14, 21, and 28 and death or subsequent severe BPD. The RSS could provide a simple estimate of severe BPD or death., Further research with a larger study population is necessary to validate the usefulness of the RSS for predicting severe BPD or death.


Asunto(s)
Displasia Broncopulmonar/etiología , Displasia Broncopulmonar/mortalidad , Mortalidad Hospitalaria , Recien Nacido Extremadamente Prematuro , Respiración Artificial/efectos adversos , Área Bajo la Curva , Displasia Broncopulmonar/fisiopatología , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Hospitales Universitarios , Humanos , Incidencia , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Modelos Logísticos , Masculino , Análisis Multivariante , República de Corea , Respiración Artificial/métodos , Pruebas de Función Respiratoria , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA