J Cardiothorac Vasc Anesth ; 37(9): 1793-1800, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37286401

RESUMEN

Invasive pressure monitors are ubiquitous in cardiothoracic and vascular anesthesia. This technology allows beat-to-beat assessment of central venous, pulmonary, and arterial blood pressures during surgery, procedural interventions, and critical care. Education is commonly focused on the procedural aspects and the complications associated with the initial placement of these monitors without instruction on the technical concepts required for obtaining accurate data. Anesthesiologists must understand the fundamental concepts on which measurements are made to effectively use invasive pressure monitors, including pulmonary artery catheters, central venous catheters, intra-arterial catheters, external ventricular drains, and spinal or lumbar drains. This review will address important gaps in knowledge surrounding leveling and zeroing of invasive pressure monitors, emphasizing the impact of varied practice patterns on patient care.


Asunto(s)
Cateterismo Periférico , Catéteres Venosos Centrales , Humanos , Presión Arterial , Catéteres de Permanencia , Cuidados Críticos
2.
Perfusion ; 32(3): 179-182, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27794072

RESUMEN

Complications associated with long-term left ventricular assist device (LVAD) use may require pump exchange due to device thrombosis or thromboembolism. Minimally invasive off-pump procedures represent an advantageous alternative to standard full sternotomy exchanges and those performed with the use of cardiopulmonary bypass. By mitigating surgical invasion and trauma to the central chest, the potential for post-operative bleeding, transfusions and complications can be reduced. This case report describes the successful off-pump exchange of a HeartWare LVAD via left re-do-thoracotomy with the re-use of the original outflow graft.


Asunto(s)
Remoción de Dispositivos/métodos , Corazón Auxiliar/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Implantación de Prótesis/métodos , Toracotomía/métodos , Trombosis/etiología , Humanos , Masculino , Persona de Mediana Edad , Trombosis/terapia
3.
Bioengineering (Basel) ; 10(12)2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38136005

RESUMEN

Introduction: Obstructive sleep apnea (OSA) and loud snoring are conditions with increased cardiovascular risk and notably an association with stroke. Central in stroke are thrombosis and thromboembolism, all related to and initiaing with platelet activation. Platelet activation in OSA has been felt to be driven by biochemical and inflammatory means, including intermittent catecholamine exposure and transient hypoxia. We hypothesized that snore-associated acoustic vibration (SAAV) is an activator of platelets that synergizes with catecholamines and hypoxia to further amplify platelet activation. Methods: Gel-filtered human platelets were exposed to snoring utilizing a designed vibro-acoustic exposure device, varying the time and intensity of exposure and frequency content. Platelet activation was assessed via thrombin generation using the Platelet Activity State assay and scanning electron microscopy. Comparative activation induced by epinephrine and hypoxia were assessed individually as well as additively with SAAV, as well as the inhibitory effect of aspirin. Results: We demonstrate that snore-associated acoustic vibration is an independent activator of platelets, which is dependent upon the dose of exposure, i.e., intensity x time. In snoring, acoustic vibrations associated with low-frequency sound content (200 Hz) are more activating than those associated with high frequencies (900 Hz) (53.05% vs. 22.08%, p = 0.001). Furthermore, SAAV is additive to both catecholamines and hypoxia-mediated activation, inducing synergistic activation. Finally, aspirin, a known inhibitor of platelet activation, has no significant effect in limiting SAAV platelet activation. Conclusion: Snore-associated acoustic vibration is a mechanical means of platelet activation, which may drive prothrombosis and thrombotic risk clinically observed in loud snoring and OSA.

4.
J Cardiothorac Surg ; 11(1): 123, 2016 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-27487837

RESUMEN

BACKGROUND: Right ventricular failure is a serious complication after left ventricular assist device placement. CASE PRESENTATION: A 70-year-old male in decompensated heart failure with right ventricular failure after the placement of a left ventricular assist device. A single dual-lumen PROTEKDuo cannula was inserted percutaneously via the internal jugular vein to draw blood from the right atrium and return into the pulmonary artery using the CentriMag system, by passing the failing ventricle. The patient was successfully weaned from right ventricular assist device. CONCLUSIONS: In comparison to two-cannula conventional procedures, this right ventrivular assist device system improves patient rehabilitation and minimizes blood loss and risk of infection, while shortening procedure time and improving clinical outcomes in right ventricular failure.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Implantación de Prótesis/instrumentación , Disfunción Ventricular Derecha/cirugía , Anciano , Cánula , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Retrospectivos