Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Oncol Lett ; 14(5): 5249-5256, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29113160

RESUMEN

Certain patients with lymphoma may harbor mutations in perforin 1 (PRF1), unc-13 homolog D (UNC13D), syntaxin 11 (STX11), STXBP2 (syntaxin binding protein 2) or SH2 domain containing 1A (SH2D1A), which causes functional defects of cytotoxic lymphocytes. Data regarding the association between genetic defects and the development of lymphoma in Chinese patients are limited to date. In the present study, 90 patients with lymphoma were analyzed for UNC13D, PRF1, STXBP2, STX11, SH2D1A and X-linked inhibitor of apoptosis. Mutations were observed in 24 (26.67%) patients; 16 patients exhibited mutations in UNC13D, 7 exhibited PRF1 mutations, and 1 exhibited monoallelic mutation in STX11. UNC13D c.2588G>A/p.G863D mutation was detected in 9 patients (10.00%) and in 4/210 controls (1.90%). This mutation was predicted to be pathogenic and it predominantly existed in the Chinese population. These findings suggest that impaired cytotoxic machinery may represent a predisposing factor for the development of lymphoma. Furthermore, these data describe a distinct mutation spectrum in Chinese patients with lymphoma, whereby UNC13D is the most frequently mutated gene. In addition, these findings suggest UNC13D c.2588G>A mutation is a founder mutation in Chinese patients.

2.
Sci Total Environ ; 557-558: 542-50, 2016 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-27037875

RESUMEN

Batch experiments were conducted to investigate the effects of cathode materials and anions (Cl(-), SO4(2-), NO3(-), and CO3(2-)/HCO3(-)) on perfluorooctanoate (PFOA) removal in electrocoagulation process using zinc anode. The results indicated that the hydroxide flocs generated in-situ in the electrocoagulation process using the stainless steel rod as cathode were more effective than those using aluminum rod as cathode for the removal of PFOA after 20min of electrocoagulation at a current density of 0.5mAcm(-2). Hydroxide flocs generated in-situ in the electrocoagulation in the presence of Cl(-)/NO3(-) could effectively remove PFOA from aqueous solution with the removal ratios of 99.7%/98.1% and 98.9%/97.3% using stainless steel rod and aluminum rod as cathode, respectively. However, the PFOA removal ratios were 96.2%/4.1% and 7.4%/4.6% using stainless steel rod and aluminum rod as cathode, respectively, in the presence of SO4(2-) and CO3(2-)/HCO3(-). The different removal ratios of PFOA during the electrocoagulation process were primarily due to the fact that the hydroxide flocs generated in-situ were different in the presence of diverse cathodes and anions. We firstly demonstrated that Zn0.70Al0.30(OH)2(CO3)0.15·xH2O and ZnO generated in-situ in the electrocoagulation process (except for CO3(2-)/HCO3(-)) using zinc anode and aluminum/stainless steel rod cathode governed the sorption of PFOA. The adsorbent hydroxide flocs in-situ generated in the presence of Cl(-) could effectively remove PFOA from aqueous solution containing CO3(2-)/HCO3(-) anion at the initial hydroxide flocs concentration of 2000mgL(-1). These results provided an effective and alternative method to remove PFOA from aqueous solution containing CO3(2-)/HCO3(-) anion.


Asunto(s)
Caprilatos/química , Fluorocarburos/química , Contaminantes Químicos del Agua/química , Purificación del Agua/métodos , Zinc/química , Electroquímica/métodos , Electrodos , Concentración de Iones de Hidrógeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA