Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Lasers Surg Med ; 49(3): 280-292, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27990658

RESUMEN

BACKGROUND: Metastasis of colorectal cancer to the liver is the most common indication for hepatic resection in a western population. Incomplete excision of malignancy due to residual microscopic disease normally results in worse patient outcome. Therefore, a method aiding in the real time discrimination of normal and malignant tissue on a microscopic level would be of benefit. MATERIAL AND METHODS: The ability of fluorescent probe-based confocal laser endomicroscopy (pCLE) to identify normal and malignant liver tissue was evaluated in an orthotopic murine model of colorectal cancer liver metastasis (CRLM). To maximise information yield, two clinical fluorophores, fluorescein and indocyanine green (ICG) were injected and imaged in a dual wavelength approach (488 and 660 nm, respectively). Visual tissue characteristics on pCLE examination were compared with histological features. Fluorescence intensity in both tissues was statistically analysed to elucidate if this can be used to differentiate between normal and malignant tissue. RESULTS: Fluorescein (488 nm) enabled good visualisation of normal and CRLM tissue, whereas ICG (660 nm) visualisation was limited to normal liver tissue only. Fluorescence intensity in areas of CRLM was typically 53-100% lower than normal hepatic parenchyma. Using general linear mixed modelling and receiver operating characteristic analysis, high fluorescence intensity was found to be statistically more likely in normal hepatic tissue. CONCLUSION: Real time discrimination between normal liver parenchyma and metastatic tissue with pCLE examination of fluorescein and ICG is feasible. Employing two (rather than a single) fluorophores allows a combination of qualitative and quantitative characteristics to be used to distinguish between hepatic parenchyma and CRLM. Lasers Surg. Med. 49:280-292, 2017. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Fluoresceína , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Microscopía Confocal/métodos , Animales , Biopsia con Aguja , Modelos Animales de Enfermedad , Femenino , Humanos , Inmunohistoquímica , Neoplasias Hepáticas/patología , Ratones , Ratones Endogámicos , Distribución Aleatoria , Valores de Referencia
2.
Lasers Surg Med ; 48(3): 299-310, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26718623

RESUMEN

BACKGROUND: Laparoscopic liver ablation therapy can be used for the treatment of primary and secondary liver malignancy. The increased incidence of cancer recurrence associated with this approach, has been attributed to the inability of monitoring the extent of ablated liver tissue. METHODS: The feasibility of assessing liver ablation with probe-based confocal laser endomicroscopy (CLE) was studied in a porcine model of laparoscopic microwave liver ablation. Following the intravenous injection of the fluorophores fluorescein and indocyanine green, CLE images were recorded at 488 nm and 660 nm wavelength and compared to liver histology. Statistical analysis was performed to assess if fluorescence intensity change can predict the presence of ablated liver tissue. RESULTS: CLE imaging of fluorescein at 488 nm provided good visualization of the hepatic microvasculature; whereas, CLE imaging of indocyanine green at 660 nm enabled detailed visualization of hepatic sinusoid architecture and interlobular septations. Fluorescence intensity as measured in relative fluorescence units was found to be 75-100% lower in ablated compared to healthy liver regions. General linear mixed modeling and ROC analysis found the decrease in fluorescence to be statistically significant. CONCLUSION: Laparoscopic, dual wavelength CLE imaging using two different fluorophores enables clinically useful visualization of multiple liver tissue compartments, in greater detail than is possible at a single wavelength. CLE imaging may provide valuable intraoperative information on the extent of laparoscopic liver ablation.


Asunto(s)
Técnicas de Ablación/métodos , Hepatectomía/métodos , Hígado/cirugía , Microondas/uso terapéutico , Animales , Endoscopía , Estudios de Factibilidad , Femenino , Fluoresceína , Colorantes Fluorescentes , Verde de Indocianina , Modelos Lineales , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Hígado/patología , Microscopía Confocal/métodos , Porcinos
3.
J Med Chem ; 58(15): 6058-80, 2015 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-26161456

RESUMEN

Increased activity of efflux transporters, e.g., P-glycoprotein (P-gp) and breast cancer resistance protein (BCRP), at the blood-brain barrier is a pathological hallmark of many neurological diseases, and the resulting multiple drug resistance represents a major clinical challenge. Noninvasive imaging of transporter activity can help to clarify the underlying mechanisms of drug resistance and facilitate diagnosis, patient stratification, and treatment monitoring. We have developed a metabolically activated radiotracer for functional imaging of P-gp/BCRP activity with positron emission tomography (PET). In preclinical studies, the tracer showed excellent initial brain uptake and clean conversion to the desired metabolite, although at a sluggish rate. Blocking with P-gp/BCRP modulators led to increased levels of brain radioactivity; however, dynamic PET did not show differential clearance rates between treatment and control groups. Our results provide proof-of-concept for development of prodrug tracers for imaging of P-gp/BCRP function in vivo but also highlight some challenges associated with this strategy.


Asunto(s)
Radioisótopos de Flúor/química , Proteínas de Transporte de Membrana/metabolismo , Tomografía de Emisión de Positrones/métodos , Animales , Barrera Hematoencefálica , Femenino , Ratones , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA