Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 328
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Clin Chem ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38776253

RESUMEN

BACKGROUND: Reference change values (RCV) are used to indicate a change in analyte concentration that is unlikely to be due to random variation in the patient or the measurement. Current theory describes RCV relative to a first measurement result (X1). We investigate an alternative view predicting the starting point for RCV calculations from X1 and its location in the reference interval. METHODS: Data for serum sodium, calcium, and total protein from the European Biological Variation study and from routine clinical collections were analyzed for the effect of the position of X1 within the reference interval on the following result from the same patient. A model to describe the effect was determined, and an equation to predict the RCV for a sample in a population was developed. RESULTS: For all data sets, the midpoints of the RCVs were dependent on the position of X1 in the population. Values for X1 below the population mean were more likely to be followed by a higher result, and X1 results above the mean were more likely to be followed by lower results. A model using population mean, reference interval dispersion, and result diagnostic variation provided a good fit with the data sets, and the derived equation predicted the changes seen. CONCLUSIONS: We have demonstrated that the position of X1 within the reference interval creates an asymmetrical RCV. This can be described as a regression to the population mean. Adding this concept to the theory of RCVs will be an important consideration in many cases.

2.
Clin Chem Lab Med ; 62(8): 1512-1519, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38624006

RESUMEN

Analytical performance specifications (APS) are used for the quantitative assessment of assay analytical performance, with the aim of providing information appropriate for clinical care of patients. One of the major locations where APS are used is in the routine clinical laboratory. These may be used to assess and monitor assays in a range of settings including method selection, method verification or validation, external quality assurance, internal quality control and assessment of measurement uncertainty. The aspects of assays that may be assessed include imprecision, bias, selectivity, sample type, analyte stability and interferences. This paper reviews the practical use of APS in a routine clinical laboratory, using the laboratory I supervise as an example.


Asunto(s)
Laboratorios Clínicos , Control de Calidad , Humanos , Laboratorios Clínicos/normas , Técnicas de Laboratorio Clínico/normas
3.
Clin Chem Lab Med ; 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38436623

RESUMEN

OBJECTIVES: Laboratory results are increasingly interpreted against common reference intervals (CRIs), published clinical decision limits, or previous results for the same patient performed at different laboratories. However, there are no established systems to determine whether current analytical performance justifies these interpretations. We analysed data from a likely commutable external quality assurance program (EQA) to assess these interpretations. METHODS: The use of CRIs was assessed by evaluating instrument group medians against minimum specifications for bias. The use of clinical decision limits was assessed using specifications from professional bodies, and the monitoring of patients by testing at different laboratories was assessed by comparing all-laboratory imprecision to within-subject biological variation. RESULTS: Five of the 18 analytes with Australasian CRIs did not meet specification for all instrument groups. Among these, calcium and magnesium failed for one instrument group out of seven, while bicarbonate, chloride, and lipase failed for two instrument groups. Of the 18 analytes reviewed currently without CRIs in Australasia, 10 candidates were identified. Among analytes with clinical decision limits, i.e. lipids, glucose, and vitamin D, only triglycerides met both bias and imprecision specifications, while vitamin D met the imprecision specification. Monitoring patients by testing at different laboratories was supported for 15 of the 46 (33 %) analyte-method principles groups that met minimum imprecision specifications. CONCLUSIONS: Analysis of data from commutable EQA programs can provide a mechanism for monitoring whether analytical performance justifies the interpretations made in contemporary laboratory practice. EQA providers should establish systems for routinely providing this information to the laboratory community.

4.
Clin Chem Lab Med ; 62(8): 1531-1537, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38801089

RESUMEN

Analytical performance specifications (APS) are used for decisions about the required analytical quality of pathology tests to meet clinical needs. The Milan models, based on clinical outcome, biological variation, or state of the art, were developed to provide a framework for setting APS. An approach has been proposed to assign each measurand to one of the models based on a defined clinical use, physiological control, or an absence of quality information about these factors. In this paper we propose that in addition to such assignment, available information from all models should be considered using a risk-based approach that considers the purpose and role of the actual test in a clinical pathway and its impact on medical decisions and clinical outcomes in addition to biological variation and the state-of-the-art. Consideration of APS already in use and the use of results in calculations may also need to be considered to determine the most appropriate APS for use in a specific setting.


Asunto(s)
Control de Calidad , Humanos , Técnicas de Laboratorio Clínico/normas , Modelos Teóricos
5.
Clin Chem Lab Med ; 62(8): 1474-1482, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38836433

RESUMEN

Analytical performance specifications (APS) based on outcomes refer to how 'good' the analytical performance of a test needs to be to do more good than harm to the patient. Analytical performance of a measurand affects its clinical performance. Without first setting clinical performance requirements, it is difficult to define how good analytically the test needs to be to meet medical needs. As testing is indirectly linked to health outcomes through clinical decisions on patient management, often simulation-based studies are used to assess the impact of analytical performance on the probability of clinical outcomes which is then translated to Model 1b APS according to the Milan consensus. This paper discusses the related key definitions, concepts and considerations that should assist in finding the most appropriate methods for deriving Model 1b APS. We review the advantages and limitations of published methods and discuss the criteria for transferability of Model 1b APS to different settings. We consider that the definition of the clinically acceptable misclassification rate is central to Model 1b APS. We provide some examples and guidance on a more systematic approach for first defining the clinical performance requirements for tests and we also highlight a few ideas to tackle the future challenges associated with providing outcome-based APS for laboratory testing.


Asunto(s)
Técnicas de Laboratorio Clínico , Humanos , Técnicas de Laboratorio Clínico/normas
6.
Heart Lung Circ ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38705780

RESUMEN

Troponin is an important diagnostic tool, however, as the assay sensitivity and frequency of testing has increased in the COVID-19 era, a new cohort of patients with persistently elevated troponin has emerged. Interfering antibodies should be considered in patients with persistent and stable troponin elevation, where there is no ongoing cause.

7.
N Engl J Med ; 382(26): 2504-2513, 2020 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-32579811

RESUMEN

BACKGROUND: Elevated serum urate levels are associated with progression of chronic kidney disease. Whether urate-lowering treatment with allopurinol can attenuate the decline of the estimated glomerular filtration rate (eGFR) in patients with chronic kidney disease who are at risk for progression is not known. METHODS: In this randomized, controlled trial, we randomly assigned adults with stage 3 or 4 chronic kidney disease and no history of gout who had a urinary albumin:creatinine ratio of 265 or higher (with albumin measured in milligrams and creatinine in grams) or an eGFR decrease of at least 3.0 ml per minute per 1.73 m2 of body-surface area in the preceding year to receive allopurinol (100 to 300 mg daily) or placebo. The primary outcome was the change in eGFR from randomization to week 104, calculated with the Chronic Kidney Disease Epidemiology Collaboration creatinine equation. RESULTS: Enrollment was stopped because of slow recruitment after 369 of 620 intended patients were randomly assigned to receive allopurinol (185 patients) or placebo (184 patients). Three patients per group withdrew immediately after randomization. The remaining 363 patients (mean eGFR, 31.7 ml per minute per 1.73 m2; median urine albumin:creatinine ratio, 716.9; mean serum urate level, 8.2 mg per deciliter) were included in the assessment of the primary outcome. The change in eGFR did not differ significantly between the allopurinol group and the placebo group (-3.33 ml per minute per 1.73 m2 per year [95% confidence interval {CI}, -4.11 to -2.55] and -3.23 ml per minute per 1.73 m2 per year [95% CI, -3.98 to -2.47], respectively; mean difference, -0.10 ml per minute per 1.73 m2 per year [95% CI, -1.18 to 0.97]; P = 0.85). Serious adverse events were reported in 84 of 182 patients (46%) in the allopurinol group and in 79 of 181 patients (44%) in the placebo group. CONCLUSIONS: In patients with chronic kidney disease and a high risk of progression, urate-lowering treatment with allopurinol did not slow the decline in eGFR as compared with placebo. (Funded by the National Health and Medical Research Council of Australia and the Health Research Council of New Zealand; CKD-FIX Australian New Zealand Clinical Trials Registry number, ACTRN12611000791932.).


Asunto(s)
Alopurinol/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Nefropatías Diabéticas/tratamiento farmacológico , Inhibidores Enzimáticos/uso terapéutico , Tasa de Filtración Glomerular/efectos de los fármacos , Supresores de la Gota/uso terapéutico , Ácido Úrico/sangre , Xantina Oxidasa/antagonistas & inhibidores , Anciano , Alopurinol/efectos adversos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/fisiopatología , Nefropatías Diabéticas/fisiopatología , Progresión de la Enfermedad , Método Doble Ciego , Inhibidores Enzimáticos/efectos adversos , Femenino , Supresores de la Gota/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Renal Crónica/tratamiento farmacológico , Insuficiencia Renal Crónica/fisiopatología , Sistema Renina-Angiotensina , Insuficiencia del Tratamiento
8.
Clin Chem ; 69(1): 100-109, 2023 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-36373220

RESUMEN

BACKGROUND: Biological variation (BV) data may be used to develop analytical performance specifications (APS), reference change values (RCV), and support the applicability of population reference intervals. This study estimates within-subject BV (CVI) for several endocrine biomarkers using 3 different methodological approaches. METHODS: For the direct method, 30 healthy volunteers were sampled weekly for 10 consecutive weeks. Samples were analyzed in duplicate for 17-hydroxyprogesterone (17-OHP), androstenedione, cortisol, cortisone, estradiol, follicle-stimulating hormone (FSH), luteinizing hormone (LH), sex hormone-binding globulin (SHBG), and testosterone. A CV-ANOVA with outlier removal and a Bayesian model were applied to derive the CVI. For estradiol, FSH and LH, only the male subgroup was included. In the indirect method, using the same analytes and groups, pairs of sequential results were extracted from the laboratory information system. The total result variation for individual pairs was determined by identifying a central gaussian distribution in the ratios of the result pairs. The CVI was then estimated by removing the effect of analytical variation. RESULTS: The estimated CVI from the Bayesian model (µCVP(i)) in the total cohort was: 17-OHP, 23%; androstenedione, 20%; cortisol, 18%; cortisone, 11%; SHBG, 7.4%; testosterone, 16%; and for the sex hormones in men: estradiol, 14%; FSH, 8%; and LH, 26%. CVI-heterogeneity was present for most endocrine markers. Similar CVI data were estimated using the CV-ANOVA and the indirect method. CONCLUSIONS: Similar CVI data were obtained using 2 different direct and one indirect method. The indirect approach is a low-cost alternative ensuring implementation of CVI data applicable for local conditions.


Asunto(s)
Androstenodiona , Cortisona , Masculino , Humanos , Hidrocortisona , Teorema de Bayes , Hormonas Esteroides Gonadales , Hormona Luteinizante , Hormona Folículo Estimulante , Estradiol , Esteroides , Testosterona , Globulina de Unión a Hormona Sexual
9.
Clin Chem Lab Med ; 61(3): 402-406, 2023 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-36457149

RESUMEN

Reference intervals are established either by direct or indirect approaches. Whereas the definition of direct is well established, the definition of indirect is still a matter of debate. In this paper, a general definition that covers all indirect models presently in use is proposed. With the upcoming popularity of indirect models, it has become evident that further partitioning strategies are required to minimize the risk of patients' false classifications. With indirect methods, such partitions are much easier to execute than with direct methods. The authors believe that the future of reference interval estimation belongs to indirect models with big data pools either from one laboratory or combined from several regional centres (if necessary). Independent of the approach applied, the quality assurance of the pre-analytical and analytical phase, considering biological variables and other confounding factors, is essential.


Asunto(s)
Macrodatos , Laboratorios , Humanos , Valores de Referencia
10.
Clin Chem Lab Med ; 61(9): 1612-1618, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37272075

RESUMEN

OBJECTIVES: In clinical practice, steroid measurements are performed mainly by direct, non-extraction immunoassays adapted to high throughput, automated immunoassay platforms and employing secondary calibrators. The accuracy of such steroid immunoassays is limited by cross-reactivity with structurally related steroids and nonspecific matrix interference as well as the metrological traceability of manufacturer supplied calibrators. The accuracy of steroid immunoassay calibrators has been little investigated by independent chemical methods. METHODS: Steroid concentrations of 41 calibrators (4-6 replicates per calibrator) supplied by four manufacturers for use in testosterone (T), estradiol (E2), and progesterone (P4) commercial immunoassays were measured by ultra-pressure liquid chromatography-mass spectrometry (UPLC-MS). RESULTS: Among 14 non-zero T calibrators, six (43 %) deviated significantly from the label concentration with 29 % outside 20 % of it. Among 14 E2 calibrators, eight (57 %) deviated significantly, whereas seven (50 %) were outside 20 % of the label concentration. Among 11 P4 calibrators, eight (73 %) deviated significantly whereas four (36 %) were outside within 20 % of the label concentration. CONCLUSIONS: We conclude that inaccurate calibration of manufacturer's supplied standards may contribute to inaccuracy of commercial direct steroid immunoassays.


Asunto(s)
Estradiol , Testosterona , Humanos , Cromatografía Liquida/métodos , Progesterona , Calibración , Espectrometría de Masas en Tándem/métodos , Esteroides , Inmunoensayo
11.
Thorax ; 77(9): 900-912, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-34848555

RESUMEN

BACKGROUND: Risk factors for severe COVID-19 include older age, male sex, obesity, black or Asian ethnicity and underlying medical conditions. Whether these factors also influence susceptibility to developing COVID-19 is uncertain. METHODS: We undertook a prospective, population-based cohort study (COVIDENCE UK) from 1 May 2020 to 5 February 2021. Baseline information on potential risk factors was captured by an online questionnaire. Monthly follow-up questionnaires captured incident COVID-19. We used logistic regression models to estimate multivariable-adjusted ORs (aORs) for associations between potential risk factors and odds of COVID-19. RESULTS: We recorded 446 incident cases of COVID-19 in 15 227 participants (2.9%). Increased odds of developing COVID-19 were independently associated with Asian/Asian British versus white ethnicity (aOR 2.28, 95% CI 1.33 to 3.91), household overcrowding (aOR per additional 0.5 people/bedroom 1.26, 1.11 to 1.43), any versus no visits to/from other households in previous week (aOR 1.31, 1.06 to 1.62), number of visits to indoor public places (aOR per extra visit per week 1.05, 1.02 to 1.09), frontline occupation excluding health/social care versus no frontline occupation (aOR 1.49, 1.12 to 1.98) and raised body mass index (BMI) (aOR 1.50 (1.19 to 1.89) for BMI 25.0-30.0 kg/m2 and 1.39 (1.06 to 1.84) for BMI >30.0 kg/m2 versus BMI <25.0 kg/m2). Atopic disease was independently associated with decreased odds (aOR 0.75, 0.59 to 0.97). No independent associations were seen for age, sex, other medical conditions, diet or micronutrient supplement use. CONCLUSIONS: After rigorous adjustment for factors influencing exposure to SARS-CoV-2, Asian/Asian British ethnicity and raised BMI were associated with increased odds of developing COVID-19, while atopic disease was associated with decreased odds. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04330599).


Asunto(s)
COVID-19 , COVID-19/epidemiología , Estudios de Cohortes , Humanos , Estudios Longitudinales , Masculino , Estudios Prospectivos , Factores de Riesgo , SARS-CoV-2 , Reino Unido/epidemiología
12.
Amino Acids ; 54(7): 1001-1011, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35386060

RESUMEN

Hypertension is a major risk factor for kidney and cardiovascular disease. The treatment of hypertensive individuals by selected ACE inhibitors and certain di-and tripeptides halts the progression of renal deterioration and extends life-span. Renal reabsorption of these low molecular weight substrates are mediated by the PEPT1 and PEPT2 cotransporters. This study aims to investigate whether hypertension and ageing affects renal PEPT cotransporters at gene, protein expression and distribution as well as function in the superficial cortex and the outer medulla of the kidney. Membrane vesicles from the brush border (BBMV) and outer medulla (OMMV) were isolated from the kidneys of young Wistar Kyoto (Y-WKY), young spontaneously hypertensive (Y-SHR), and middle aged SHR (M-SHR) rats. Transport activity was measured using the substrate, ß-Ala-Lys (AMCA). Gene expression levels of PEPT genes were assessed with qRT-PCR while renal localisation of PEPT cotransporters was examined by immunohistochemistry with Western Blot validation. The Km and Vmax of renal PEPT1 were decreased significantly in SHR compared to WKY BBMV, whilst the Vmax of PEPT2 showed differences between SHR and WKY. By contrast to the reported cortical distribution of PEPT1, PEPT1-staining was detected in the outer medulla, whilst PEPT2 was expressed primarily in the cortex of all SHR; PEPT1 was significantly upregulated in the cortex of Y-SHR. These outcomes are indicative of a redistribution of PEPT1 and PEPT2 in the kidney proximal tubule under hypertensive conditions that has potential repercussions for nutrient handling and the therapeutic use of ACE inhibitors in hypertensive individuals.


Asunto(s)
Hipertensión , Simportadores , Inhibidores de la Enzima Convertidora de Angiotensina , Animales , Hipertensión/genética , Hipertensión/metabolismo , Riñón/metabolismo , Transportador de Péptidos 1/genética , Transportador de Péptidos 1/metabolismo , Péptidos/metabolismo , Ratas , Ratas Endogámicas SHR , Ratas Endogámicas WKY , Roedores/metabolismo , Simportadores/genética , Simportadores/metabolismo
13.
Ther Drug Monit ; 44(1): 121-132, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34882107

RESUMEN

ABSTRACT: Individualization of vancomycin dosing based on therapeutic drug monitoring (TDM) data is known to improve patient outcomes compared with fixed or empirical dosing strategies. There is increasing evidence to support area-under-the-curve (AUC24)-guided TDM to inform vancomycin dosing decisions for patients receiving therapy for more than 48 hours. It is acknowledged that there may be institutional barriers to the implementation of AUC24-guided dosing, and additional effort is required to enable the transition from trough-based to AUC24-based strategies. Adequate documentation of sampling, correct storage and transport, accurate laboratory analysis, and pertinent data reporting are required to ensure appropriate interpretation of TDM data to guide vancomycin dosing recommendations. Ultimately, TDM data in the clinical context of the patient and their response to treatment should guide vancomycin therapy. Endorsed by the International Association of Therapeutic Drug Monitoring and Clinical Toxicology, the IATDMCT Anti-Infectives Committee, provides recommendations with respect to best clinical practice for vancomycin TDM.


Asunto(s)
Antiinfecciosos , Vancomicina , Antibacterianos , Área Bajo la Curva , Monitoreo de Drogas/métodos , Humanos
14.
Clin Chem Lab Med ; 60(5): 669-674, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35179002

RESUMEN

The role of an External Quality Assurance (EQA) program is generally seen as providing a service to routine laboratories that their analytical performance is satisfactory and stimulating corrective action in the event of poor results. It is recognised that an ideal EQA program uses materials that are commutable with patient samples and have values assigned by higher-order reference methods. Despite this, most routine EQA programs use materials without verified commutability and use consensus means (based on either peer group or all laboratories) as target values. We propose an ongoing role for EQA programs using non-commutable materials and consensus targets to support the measurement services of routine laboratories. This is provided the relevant comparators supplied by the laboratory, e.g. reference intervals and clinical decision points, are based on the same or equivalent measurement system as is used by the laboratory. Materials without verified commutability often have certain practical advantages, which may include the range of analyte concentrations, verified stability, replicate samples and, significantly, lower costs. Laboratories using such programs need to be aware of the limitations, especially comparing results from different measurement systems. However, we also recognise that as well as individual laboratories, data from EQA programs informs manufacturers, professional organisations, clinical guideline writers and other medical bodies For consideration beyond an individual laboratory, proper assessment of differences between measurement systems (results harmonization) and demonstration of correct implementation of metrological traceability (methods trueness) become vital, and for that purpose, commutability of EQA materials and traceability of target values are required.


Asunto(s)
Laboratorios , Humanos , Control de Calidad , Estándares de Referencia
15.
Clin Chem Lab Med ; 60(11): 1736-1744, 2022 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-36036565

RESUMEN

OBJECTIVES: To assess interlaboratory variability of total serum bilirubin (TSB) results in newborns. Initiated following a clinical incident in which a neonate was transferred to a tertiary hospital for treatment of severe hyperbilirubinemia but on arrival was reclassified into a lower risk category due to a 20% difference in TSB between laboratories. METHODS: Fresh residual plasma samples from hospital-born infants were pooled to obtain 11 samples across a range of total bilirubin concentrations. Aliquots were light-protected and measured on 7 commercial platforms at 4 accredited medical laboratories. Data from The Royal College of Pathologists of Australasia Quality Assurance Programs' (RCPAQAP) Neonatal Bilirubin program was analysed. RESULTS: Twenty-four to 30% difference in results for individual samples, largely due to calibration differences between assays. When interpreted according to guidelines, results from different platforms would have led to different clinical interventions in some cases. RCPAQAP results showed significant within-method bias but were not shown to be commutable with patient samples. CONCLUSIONS: There are clinically significant method-dependent differences in TSB results from neonatal samples, consistent with our clinical incident. The differences are largely due to lack of standardisation of calibrator values. This has implications for healthcare resource use and possibly for the neurodevelopment of infants. Intervention is needed at a number of levels, including clinical reporting of incidents arising from discordant results, commitment by manufacturers to ensure metrological traceability of methods with sufficiently low uncertainty in the final measurements, and availability of commutable quality assurance material to monitor assay performance, especially at the clinical decision points for neonatal jaundice.


Asunto(s)
Hiperbilirrubinemia Neonatal , Ictericia Neonatal , Bilirrubina , Calibración , Humanos , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/terapia , Lactante , Recién Nacido , Ictericia Neonatal/terapia , Estándares de Referencia
16.
Eur Respir J ; 58(2)2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33446611

RESUMEN

Exercise-induced bronchoconstriction (EIBc) is a recognised response to exercise in asthmatic subjects and athletes but is less well understood in an unselected broad population. Exercise-induced bronchodilation (EIBd) has received even less attention. The objective of this study was to investigate the effects of age, sex, forced expiratory volume in 1 s (FEV1) and airflow limitation (FEV1/forced vital capacity (FVC) <0.7) on the prevalence of EIBc and EIBd.This was a retrospective study based on incremental cardiopulmonary exercise testing on cycle ergometry to symptom limitation performed between 1988 and 2012. FEV1 was measured before and 10 min after exercise. EIBc was defined as a percentage fall in FEV1 post-exercise below the 5th percentile, while EIBd was defined as a percentage increase in FEV1 above the 95th percentile.35 258 subjects aged 6-95 years were included in the study (mean age 53 years, 60% male) and 10.3% had airflow limitation (FEV1/FVC <0.7). The lowest 5% of subjects demonstrated a ≥7.6% fall in FEV1 post-exercise (EIBc), while the highest 5% demonstrated a >11% increase in FEV1 post-exercise (EIBd). The probability of both EIBc and EIBd increased with age and was highest in females across all ages (OR 1.76, 95% CI 1.60-1.94; p<0.0001). The probability of EIBc increased as FEV1 % pred declined (<40%: OR 4.38, 95% CI 3.04-6.31; p<0.0001), with a >2-fold increased likelihood in females (OR 2.31, 95% CI 1.71-3.11; p<0.0001), with a trend with airflow limitation (p=0.06). The probability of EIBd increased as FEV1 % pred declined, in the presence of airflow limitation (OR 1.55, 95% CI 1.24-1.95; p=0.0001), but sex had no effect.EIBc and EIBd can be demonstrated at the population level, and are influenced by age, sex, FEV1 % pred and airflow limitation.


Asunto(s)
Broncoconstricción , Pulmón , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Pruebas de Función Respiratoria , Estudios Retrospectivos , Espirometría , Capacidad Vital
17.
Amino Acids ; 53(2): 183-193, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33404911

RESUMEN

Some dipeptides have been implicated in myocardial protection, but little is known about their membrane transporter PEPT2. The aim of this study was to determine whether the expression and activity of the cardiac-type PEPT2 cotransporter could be affected by ageing and/or hypertension. Sarcolemmal vesicles (SV) were isolated from the hearts of all rat groups using a standard procedure to investigate the transport activity and protein abundance by fluorescence spectroscopy and Western blot, respectively. SLC15A2 "PEPT2" gene expression was relatively quantified by RT-qPCR. In the Wistar rat groups, the protein and gene expression of PEPT2 were upregulated with ageing. These changes were accompanied by corresponding increases in the competitive inhibition and the transport rate (Vmax) of ß-Ala-Lys (AMCA) into SV isolated from middle-aged hearts. Although, the transport rate of ß-Ala-Lys (AMCA) into SV isolated from old hearts was significantly the lowest compared to middle-aged and young adult hearts, the inhibition percentage of ß-Ala-Lys (AMCA) transport by Gly-Gln was the highest. In the WKY and SHR rat groups, Y-SHR hypertrophied hearts showed an increase in PEPT2 gene expression accompanied by a significant decrease in protein expression and activity. With advanced age, however, M-SHR hypertrophied hearts revealed significantly lower gene expression, but higher protein expression and activity than Y-SHR hearts. These findings suggest that increased expression of PEPT2 cotransporter in all types of middle-aged hearts could be exploited to facilitate di-and tripeptide transport by PEPT2 in these hearts, which subsequently could result in improved myocardial protection in these populations.


Asunto(s)
Envejecimiento/metabolismo , Cardiomegalia/metabolismo , Hipertensión/metabolismo , Simportadores/metabolismo , Animales , Transporte Biológico , Cardiomegalia/genética , Dipéptidos/metabolismo , Hipertensión/genética , Masculino , Ratas , Ratas Endogámicas SHR , Ratas Endogámicas WKY , Simportadores/genética
18.
Syst Biol ; 68(1): 19-31, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29800341

RESUMEN

This article focuses on the problem of estimating a species tree from multilocus data in the presence of incomplete lineage sorting and migration. I develop a mathematical model similar to IMa2 (Hey 2010) for the relevant evolutionary processes which allows both the population size parameters and the migration rates between pairs of species tree branches to be integrated out. I then describe a BEAST2 package DENIM (Divergence estimation notwithstanding ILS and migration) which is based on this model and which uses an approximation to sample from the posterior. The approximation is based on the assumption that migrations are rare, and it only samples from certain regions of the posterior which seem likely given this assumption. The method breaks down if there is a lot of migration. Using simulations, Leaché et al. (2014) showed that using the standard multispecies coalescent model to infer a species tree can result in poor accuracy if migration is present. I reanalyze this simulated data to explore DENIM's performance and demonstrate substantial improvements in accuracy over *BEAST. I also reanalyze an empirical data set.


Asunto(s)
Evolución Biológica , Clasificación/métodos , Modelos Biológicos , Simulación por Computador , Densidad de Población
19.
PLoS Comput Biol ; 15(4): e1006650, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30958812

RESUMEN

Elaboration of Bayesian phylogenetic inference methods has continued at pace in recent years with major new advances in nearly all aspects of the joint modelling of evolutionary data. It is increasingly appreciated that some evolutionary questions can only be adequately answered by combining evidence from multiple independent sources of data, including genome sequences, sampling dates, phenotypic data, radiocarbon dates, fossil occurrences, and biogeographic range information among others. Including all relevant data into a single joint model is very challenging both conceptually and computationally. Advanced computational software packages that allow robust development of compatible (sub-)models which can be composed into a full model hierarchy have played a key role in these developments. Developing such software frameworks is increasingly a major scientific activity in its own right, and comes with specific challenges, from practical software design, development and engineering challenges to statistical and conceptual modelling challenges. BEAST 2 is one such computational software platform, and was first announced over 4 years ago. Here we describe a series of major new developments in the BEAST 2 core platform and model hierarchy that have occurred since the first release of the software, culminating in the recent 2.5 release.


Asunto(s)
Teorema de Bayes , Evolución Biológica , Filogenia , Programas Informáticos , Animales , Biología Computacional , Simulación por Computador , Evolución Molecular , Humanos , Cadenas de Markov , Modelos Genéticos , Método de Montecarlo
20.
J Immunol ; 201(2): 782-791, 2018 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-29802128

RESUMEN

Tumor hypoxia-driven accumulation of extracellular adenosine was shown to facilitate tumor evasion by engaging the immunosuppressive, intracellular cAMP-elevating A2 adenosine receptors (A2R) on tumor-reactive effector T cells, but there remains a need for careful evaluation of the limiting factors and properties of A2R blockade-enabled antitumor immunity. In studies of A2AR and/or A2BR gene-deficient mice, we found that A2AR deletion-but not A2BR deletion-liberates endogenous CD8+ T cell antitumor immunity against weakly immunogenic MCA205 sarcomas. Studies of adoptively transferred A2AR-/-, A2BR-/-, or A2AR-/-/A2BR-/- tumor-reactive T cells confirmed that immunosuppression in the tumor microenvironment was mediated by A2AR on CD8+ T cells. Treatment with A2AR antagonist mimicked A2AR gene deletion in adoptive T cell immunotherapy. This therapeutic benefit of targeting A2AR was independent of the anatomical location of tumor growth. The enhanced antitumor reactivity also led to the eradication of established intracranial tumors, which was associated with mouse survival and the maintenance of long-lasting, tumor-specific immunological memory. The blockade of the A2AR on adoptively transferred T cells by synthetic A2AR antagonist led to higher levels of IFN-γ secretion by tumor-infiltrating CD8+ T cells. These data clarify the mechanism of hypoxia-driven immunosuppression in the tumor microenvironment by A2AR on tumor-reactive CD8+ T cells and show that selective A2AR antagonists can be effective in improving the outcomes of T cell-based immunotherapies. Demonstration of the T cell dose dependency of tumor rejection points to a major limitation of current cancer immunotherapies, in which the presence of sufficient numbers of tumor-reactive T cells in a patient is not known.


Asunto(s)
Neoplasias Encefálicas/inmunología , Linfocitos T CD8-positivos/inmunología , Hipoxia/inmunología , Inmunoterapia Adoptiva/métodos , Receptor de Adenosina A2A/metabolismo , Sarcoma/inmunología , Adenosina/metabolismo , Antagonistas del Receptor de Adenosina A2/farmacología , Animales , Linfocitos T CD8-positivos/trasplante , Línea Celular Tumoral , Modelos Animales de Enfermedad , Femenino , Humanos , Tolerancia Inmunológica , Inmunidad , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Receptor de Adenosina A2A/genética , Escape del Tumor , Microambiente Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA