Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 162-170, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38009545

RESUMEN

INTRODUCTION: Pulsed field ablation (PFA) represents a novel, nonthermal energy modality that can be applied for single-shot pulmonary vein isolation (PVI) in atrial fibrillation (AF). Comparative data with regard to deep sedation to established single-shot modalities such as cryoballoon (CB) ablation are scarce. The aim of this study was to compare a deep sedation protocol in patients receiving PVI with either PFA or CB. METHODS: Prospective, consecutive AF patients undergoing PVI with a pentaspline PFA catheter were compared to a retrospective CB-PVI cohort of the same timeframe. Study endpoints were the requirements of analgesics, cardiorespiratory stability, and sedation-associated complications. RESULTS: A total of 100 PVI patients were included (PFA n = 50, CB n = 50, mean age 66 ± 10.6, 61% male patients, 65% paroxysmal AF). Requirement of propofol, midazolam, and sufentanyl was significantly higher in the PFA group compared to CB [propofol 0.14 ± 0.04 mg/kg/min in PFA vs. 0.11 ± 0.04 mg/kg/min in CB (p = .001); midazolam 0.00086 ± 0.0004 mg/kg/min in PFA vs. 0.0006295 ± 0.0003 mg/kg/min in CB (p = .002) and sufentanyl 0.0013 ± 0.0007 µg/kg/min in PFA vs. 0.0008 ± 0.0004 µg/kg/min in CB (p < .0001)]. Sedation-associated complications did not differ between both groups (PFA n = 1/50 mild aspiration pneumonia, CB n = 0/50, p > .99). Nonsedation-associated complications (PFA: n = 2/50, 4%, CB: n = 1/50, 2%, p > .99) and procedure times (PFA 75 ± 31, CB 84 ± 32 min, p = .18) did not differ between groups. CONCLUSIONS: PFA is associated with higher sedation and especially analgesia requirements. However, the safety of deep sedation does not differ to CB ablation.


Asunto(s)
Analgesia , Fibrilación Atrial , Criocirugía , Propofol , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Midazolam/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos
2.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38513110

RESUMEN

AIMS: Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS: Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44 min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6 min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION: Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.

3.
J Cardiovasc Electrophysiol ; 33(12): 2467-2472, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36217995

RESUMEN

INTRODUCTION: Recently, the wide-band dielectric mapping system Kodex-EPD was introduced. This study reports the first clinical experience using a novel system to guide pulmonary vein isolation (PVI) with radiofrequency (RF) ablation. METHODS AND RESULTS: The study included 20 consecutive patients undergoing de-novo PVI for symptomatic paroxysmal or persistent atrial fibrillation guided by Kodex-EPD. The primary efficacy endpoint was successful PVI. Secondary endpoints included procedural parameters and complications. In all 20 patients (mean age 68 ± 8 years, 12 male patients, paroxysmal fibrillation in 14/20 [70%] patients), PVI was successfully completed. One patient underwent additional cavo-tricuspid isthmus ablation for concomitant typical atrial flutter and one patient required additional ablation of a focal atrial tachycardia. A conventional three-dimensional image of the left atrium as well as the innovative endocardial panoramic view were used to guide catheter manipulation and ablation. Median procedure time was 115 [1st; 3rd quartile 93,75; 140] min and median total fluoroscopy time was 9.9 [9.7; 11.2] min, of which a median of 0.8 [0.6; 0.9] min was required to create left atrial maps. Complete left atrial imaging using Kodex-EPD was achieved within a median of 7.1 [5.7; 8.3] min. Median RF ablation time was 45.1 [34.6; 58.7] min. No major complications were observed. CONCLUSION: RF ablation PVI guided by Kodex-EPD seems safe and feasible. The system provides effective three-dimensional guidance for PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Masculino , Persona de Mediana Edad , Anciano , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 33(12): 2431-2443, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36259717

RESUMEN

INTRODUCTION: Catheter-ablation (CA) of consecutive left atrial tachycardias (LAT) can be challenging. Pulsed field ablation (PFA) yields a novel nonthermal CA technology for treatment of atrial fibrillation (AF). There is no data regarding PFA of LAT. This study sought to investigate PFA of consecutive LAT following prior CA of AF. METHODS: Consecutive patients with LAT underwent ultrahigh-density (UHDx) mapping. Subsequent to identification of the AT mechanism, PFA was performed at the assumed critical sites for LAT maintenance. Continuous ablation lines were performed if required and evaluated with pre- and post-PFA HDx-mapping. RESULTS: Fifteen patients (age 70 ± 10, male 73%) who underwent 3.6 ± 2 prior AF-CA procedures were included. The total mean procedure and fluoroscopy times were 141 ± 43 and 18 ± 10 min, respectively. All 19 of 19 (100%) LAT were successfully ablated with PFA. Two AT located at the right atria required RF-ablation. LAT were identified as localized reentry (n = 1) and macro-reentry LAT (n = 18) and targeted with PFA. All LAT terminated with PFA either to sinus rhythm (9/15) or a secondary AT (6/15 and subsequently to SR); 63% (12/19) terminated with the first PFA-application. All lines (13 roof, 11 anterior, 1 mitral) were blocked. LA-posterior-wall isolation (LAPWI) was successfully achieved when performed (10/10). AF/AT free survival was 80% (12/15) after 153 [88-207] days of follow-up. No procedure-related complications occurred. CONCLUSION: PFA of consecutive LAT is feasible and safe. Successful creation of ablation lines and LAPWI can be achieved in a short time. PFA may offer the opportunity for effective ablation of atrial arrhythmias beyond AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Taquicardia , Resultado del Tratamiento , Venas Pulmonares/cirugía
5.
J Cardiovasc Electrophysiol ; 33(3): 345-356, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34978360

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrofisiología Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 31(5): 1051-1061, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32107811

RESUMEN

INTRODUCTION: The aim of this study was to investigate electrophysiological findings in patients with arrhythmia recurrence undergoing a repeat ablation procedure using ultra-high-density (UHDx) mapping following an index procedure using either contact-force (CF)-guided radiofrequency current (RFC) pulmonary vein isolation (PVI) or second-generation cryoballoon (CB) PVI for treatment of atrial fibrillation (AF). METHODS AND RESULTS: Fifty consecutive patients with recurrence of AF and/or atrial tachycardia (AT) following index CF-RFC PVI (n = 21) or CB PVI (n = 29) were included. A 64-pole mini-basket mapping catheter in combination with an UHDx-mapping system-guided ablation was used. RFC was applied using a catheter tip with three incorporated mini-electrodes. PV reconnection rates were higher after CF-RFC PVI (CF-RFC: 2.5 ± 1.3 PVs vs CB: 1.4 ± 0.9 PVs; P = .0025) and left PVs were more frequently reconnected (CF-RFC: 64% PVs vs CB: 35% PVs; P = .0077). Fractionated signals along the antral index ablation line (FS) were found in 30% of CB-PVI patients (CF-RFC: 9.5% vs CB:30%; P = .098) targeted for ablation. In five cases, FS were a critical part of maintaining consecutive AT. The main AT mechanism found during reablation (n = 45 ATs) was macroreentry (80% [36/45], CF-RFC: 78.9% vs CB: 80.8%; P = 1.0) with a variety of circuits throughout both atria. CONCLUSION: UHDx mapping is sensitive in detecting conduction gaps along the index ablation line. Left PVs are more frequently reconnected after initial CF-RFC PVI. FS are a common finding after CB PVI and can maintain certain forms of ATs. ATs after index PVI are mostly macroreentries with a broad spectrum of entities.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Taquicardia Supraventricular/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 31(10): 2645-2652, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32748442

RESUMEN

INTRODUCTION: Tailored catheter ablation of atrial tachycardias (ATs) is increasingly recommended as a potentially easy treatment strategy in the era of high-density mapping (HDM). As follow-up data are sparse, we here report outcomes after HDM-guided ablation of ATs in patients with prior catheter ablation or cardiac surgery. METHODS AND RESULTS: In 250 consecutive patients (age 66.5 ± 0.7 years, 58% male) with ATs (98% prior catheter ablation, 13% prior cardiac surgery) an HDM-guided catheter ablation was performed with the support of a 64-electrode mini-basket catheter. A total of 354 ATs (1.4 ± 0.1 ATs per patient; mean cycle length 304 ± 4.3 ms; 64% macroreentry, 27% localized reentry, and 9% focal) with acute termination of 95% were targeted in the index procedure. A similar AT as in the index procedure recurred in five patients (2%) after a median follow-up time of 535 days (interquartile range (IQR) 25th-75th percentile: 217-841). Tailored ablation of reentry ATs with freedom from any arrhythmia was obtained in 53% after a single procedure and in 73% after 1.4 ± 0.4 ablation procedures (range: 1-4). A total of 228 patients (91%) were free from any arrhythmia recurrence after 210 days (IQR: 152-494) when including optimal usual care. CONCLUSIONS: Tailored catheter ablation of ATs guided by HDM has a high acute success rate. The recurrence rate of the index AT is low. In patients with extensive atrial scaring further ablation procedures need to be considered to achieve freedom from any arrhythmia.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Anciano , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 31(1): 61-69, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31701589

RESUMEN

AIMS: Catheter contact and local tissue characteristics are relevant information for successful radiofrequency current (RFC)-ablation. Local impedance (LI) has been shown to reflect tissue characteristics and lesion formation during RFC-ablation. Using a novel ablation catheter incorporating three mini-electrodes, we investigated LI in relation to generator impedance (GI) in patients with ventricular tachycardia (VT) and its applicability as an indicator of effective RFC-ablation. METHODS AND RESULTS: Baseline impedance, Δimpedance during ablation and drop rate (Δimpedance/time) were analyzed for 625 RFC-applications in 28 patients with recurrent VT undergoing RFC-ablation. LI was lower in scarred (87.0 Ω [79.0-95.0]) compared to healthy myocardium (97.5 Ω ([82.75-111.50]; P = .03) while GI did not differ between scarred and healthy myocardium. ΔLI was higher (18 Ω [9.4-26.0]) for VT-terminating as compared to non-terminating RFC-ablation (ΔLI 13 Ω [8.85-18.0]; P = .03), but did not differ for ΔGI between terminating vs nonterminating RFC-ablation. Correspondingly, LI drop rate was higher for RFC-ablation terminating the VT compared with RFC-ablation not terminating the VT (0.63 Ω/s [0.52-0.76] vs 0.32 Ω [0.20-0.58]; P = .008) while there was no difference for GI drop rate. ΔLI was higher in patients with nonischemic cardiomyopathy vs patients with ischemic cardiomyopathy (16 Ω [11.0-20.0] vs 11.0 Ω [7.85-17.00]; P = .003). CONCLUSION: Our findings suggest that LI is a sensitive parameter to guide RFC-ablation in patients with VT. LI indicates differences in tissue characteristics and generally is higher in patients with nonischemic cardiomyopathy. Hence, the etiology of the underlying cardiomyopathy needs to be considered when adopting LI for monitoring catheter ablation of VT.


Asunto(s)
Ablación por Catéter , Impedancia Eléctrica , Taquicardia Ventricular/cirugía , Potenciales de Acción , Anciano , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 30(5): 679-687, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30821012

RESUMEN

INTRODUCTION: Long-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM). METHODS AND RESULTS: A total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. CONCLUSION: Our findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.


Asunto(s)
Arritmias Cardíacas/terapia , Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Marcapaso Artificial , Venas Pulmonares/cirugía , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Ablación por Catéter/efectos adversos , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
10.
Europace ; 21(Supplement_1): i34-i42, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30801126

RESUMEN

AIMS: A novel measure of local impedance (LI) has been found to predict lesion formation during radiofrequency current (RFC) catheter ablation. The aim of this study was to investigate the utility of this novel approach, while comparing LI to the well-established generator impedance (GI). METHODS AND RESULTS: In 25 consecutive patients with a history of atrial fibrillation, catheter ablation was guided by a 3D-mapping system measuring LI in addition to GI via an ablation catheter tip with three incorporated mini-electrodes. Local impedance and GI before and during RFC applications were studied. In total, 381 RFC applications were analysed. The baseline LI was higher in high-voltage areas (>0.5 mV; LI: 110.5 ± 13.7 Ω) when compared with intermediate-voltage sites (0.1-0.5 mV; 90.9 ± 10.1 Ω, P < 0.001), low-voltage areas (<0.1 mV; 91.9 ± 16.4 Ω, P < 0.001), and blood pool LI (91.9 ± 9.9 Ω, P < 0.001). During ablation, mean LI drop (△LI; 13.1 ± 9.1 Ω) was 2.15 times higher as mean GI drop (△GI) (6.1 ± 4.2 Ω, P < 0.001). Baseline LI correlated with △LI: a mean LI of 99.9 Ω predicted a △LI of 12.9 Ω [95% confidence interval (12.1-13.6), R2 0.41; P < 0.001]. This relationship was weak for baseline GI predicting △GI (R2 0.06, P < 0.001). Catheter movements were represented by rapid LI changes. The duration of an RFC application was not predictive for catheter-tissue coupling with no further change of △LI (P = 0.247) nor △GI (P = 0.376) during prolonged ablation. CONCLUSION: Local impedance can be monitored during ablation. Compared with the sole use of GI, baseline LI is a better predictor of impedance drops during ablation and may provide useful insights regarding lesion formation. However, further studies are needed to investigate if this novel approach is useful to guide catheter ablation.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Impedancia Eléctrica , Anciano , Mapeo Epicárdico , Femenino , Humanos , Masculino , Proyectos Piloto , Ondas de Radio
11.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29377448

RESUMEN

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Trombosis/prevención & control , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Ecocardiografía Doppler de Pulso , Ecocardiografía Transesofágica , Cardioversión Eléctrica , Electrocardiografía , Femenino , Estado de Salud , Humanos , Incidencia , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Factores de Tiempo , Resultado del Tratamiento
12.
Europace ; 20(3): 520-527, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28340078

RESUMEN

Aims: During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Methods and results: Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Conclusion: Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.


Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Técnicas Electrofisiológicas Cardíacas , Ventrículos Cardíacos/cirugía , Imagenología Tridimensional , Interpretación de Imagen Radiográfica Asistida por Computador , Seno Aórtico/cirugía , Potenciales de Acción , Adulto , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/efectos adversos , Estudios de Factibilidad , Femenino , Fluoroscopía , Frecuencia Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Riesgo , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/fisiopatología , Resultado del Tratamiento , Función Ventricular Izquierda
13.
Europace ; 20(1): 43-49, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-27742775

RESUMEN

Introduction: Comparative data of early recurrence rates of atrial fibrillation (ERAF) following second-generation cryoballoon (CB-G2) and radiofrequency current (RFC) ablation for pulmonary vein isolation (PVI) in paroxysmal AF (PAF) are rare. We randomized PAF patients into either PVI with CB-G2 (group 1) or PVI with a combined RFC-approach applying contact force (CF) with the endpoint of unexcitability (group 2) to investigate ERAF. Methods and results: In group 1 (n = 30), CB-G2-PVI was performed. After CF-PVI in group 2 (n = 30), bipolar pacing on the ablation line and additional ablation until unexcitability was conducted. Follow-up included 48 h of in-hospital monitoring followed by 5-day Holter ECGs 1, 2, 3, 6, 12 months postablation to evaluate ERAF. Acute PVI was reached in 100% of group 2 and in 99% of group 1. Shorter procedure durations (98.0 ± 21.9 vs. 114.3 ± 18.7 min, P < 0.05) but extended fluoroscopy times (15.4 ± 3.9 vs. 10.0 ± 4.3 min, P < 0.05) were found in the CB-G2 group. Ten non-severe complications occurred (6 vs. 4 in group 1 and 2, P = 0.73). In group 2, five patients suffered from ERAF vs. seven patients in group 1 (P = 0.67). The time until the occurrence of ERAF was shorter in group 2 (1 day (q1-q3: 1-4.5)) when compared with group 1 (22 (q1-q3: 6-54) days, P = 0.025). Conclusion: ERAF rates were equal among groups; however, they occurred earlier in the initial phase after RFC ablation when compared with CB-G2. PVI utilizing cryoablation is associated with shorter procedure durations but extended fluoroscopy time while being similarly secure.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Fluoroscopía , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Proyectos Piloto , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Radiografía Intervencional , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 28(9): 1058-1067, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28597532

RESUMEN

BACKGROUND: Ablation of scar-related ventricular tachycardia (VT), especially in noninducible VT or hemodynamically unstable patients, can be challenging. Thus, we evaluated feasibility of an ultra high-density 3-D mapping approach to characterize the ventricular substrate and, if possible, to map VT. METHODS AND RESULTS: Twenty-two patients (67 ± 2 years, mean LV-EF 36 ± 3%) with both ischemic and nonischemic cardiomyopathy and documented VT underwent mapping and catheter ablation using a 64-electrode mini-basket catheter. Substrate characterization included ultra high-density voltage maps, identification of areas of slow conduction and late potentials. Whenever VT was inducible activation mapping was performed. In 13 of 22 patients, the presumed clinical VT (in 16 of 22 any VT) was inducible. A total of 50 maps were generated (22 substrate maps, 28 during VT), mapping time was 33 ± 4 minutes, number of points was 10,937 ± 1,923. Low voltage areas were related with the site of origin in all mapped VT. Isochronal maps indicated areas of slow conduction in 14 of 22 patients, all in border zone scar. In 95% of patients, late potentials were found. Mapping time during VT was 9 ± 2 minutes, number of points 6,740 ± 1,140. Covered cycle length was 82 ± 5% (16 re-entry, 10 focal, and two undetermined). During 4 months follow-up, 90% remained free from VT recurrence. CONCLUSION: Ultra high-density mapping in patients with scar-related VT is feasible, safe and enables detailed insight into tachycardia mechanisms. Critical sites can be identified (1) by precise substrate characterization when VT is not inducible or hemodynamically not tolerated and (2) during short lasting episodes of VT in order to guide catheter ablation.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Cardiomiopatías/complicaciones , Ablación por Catéter/métodos , Cicatriz/complicaciones , Frecuencia Cardíaca/fisiología , Imagenología Tridimensional/métodos , Taquicardia Ventricular/cirugía , Anciano , Cardiomiopatías/diagnóstico , Cicatriz/diagnóstico , Electrocardiografía , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Curva ROC , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 28(10): 1127-1136, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28635023

RESUMEN

INTRODUCTION: The need for transesophageal echocardiography (TEE) before catheter ablation of atrial fibrillation (CA-AF) is still being questioned. The aim of this study is to analyze patients' (patients) risk factors of left atrial appendage thrombus (LAAT) prior to CA-AF in daily clinical practice, according to oral anticoagulation (OAC) strategies recommended by current guidelines. METHODS AND RESULTS: All patients scheduled for CA-AF from 01/2015 to 12/2016 in our center were included and either treated with NOACs (novel-OAC; paused 24-hours preablation) or continuous vitamin K antagonists (INR 2.0-3.0). All patients received a preprocedural TEE at the day of ablation. Two groups were defined: (1) patients without LAAT, (2) patients with LAAT. The incidence of LAAT was 0.78% (13 of 1,658 patients). No LAAT was detected in patients with a CHA2 DS2 -VASc score of ≤1 (n = 640 patients) irrespective of the underlying AF type. Independent predictors for LAAT are: higher CHA2 DS2 -VASc scores (odds ratio [OR] 1.54, 95%-confidence interval [CI]: 1.07-2.23, P = 0.0019), a history of nonparoxysmal AF (OR 7.96, 95%-CI: 1.52-146.64, P = 0.049), hypertrophic cardiomyopathy (HCM; OR 9.63, 95% CI: 1.36-43.05, P = 0.007), and a left ventricular ejection fraction (LVEF) < 30% (OR 8.32, 95% CI: 1.18-36.29, P = 0.011). The type of OAC was not predictive (P = 0.70). CONCLUSIONS: The incidence of LAAT in patients scheduled for CA-AF is low. Therefore, periprocedural OAC strategies recommended by current guidelines seem feasible. Preprocedural TEE may be dispensed in patients with a CHA2 DS2 -VASc score ≤1. However, a CHA2 DS2 -VASc score ≥2, reduced LVEF, HCM, or history of nonparoxysmal AF are independently associated with an increased risk for LAAT.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Ecocardiografía Transesofágica/métodos , Trombosis/diagnóstico por imagen , Anciano , Antiarrítmicos/uso terapéutico , Anticoagulantes/uso terapéutico , Fibrilación Atrial/epidemiología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Medicina de Precisión , Valor Predictivo de las Pruebas , Medición de Riesgo , Volumen Sistólico , Trombosis/tratamiento farmacológico , Trombosis/epidemiología , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
16.
J Cardiovasc Electrophysiol ; 27(10): 1139-1150, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27325527

RESUMEN

INTRODUCTION: Conventional mapping of complex atrial tachycardias (ATs) can be challenging. Thus, we evaluated feasibility and utility of a novel, ultra high-density 3D mapping approach to characterize and map AT in these cases. METHODS AND RESULTS: Overall, 21 patients (67.4 ± 7.6 years; male: 52.4%, 1.9 ± 1.4 previous ablation procedures) with documented AT referred to our center underwent catheter ablation including ultra high-density mapping using a novel 64-electrode mini-basket catheter and an adjunctive 3D mapping system. A total of 24 AT (20 left atrial, 4 right atrial AT) were analyzed in 19 cases. In 2 patients, map acquisition failed due to scarce local electrograms and unstable AT cycle length, respectively. Underlying mechanisms were focal (n = 3), as well as local (n = 8) and macro (n = 13) reentry tachycardias with a mean cycle length of 311.8 ± 67.7 milliseconds. The analysis of propagation waves, activation and voltage revealed complex activation patterns and allowed for the identification of critical sites of AT initiation or maintenance without the need for further mapping techniques. In all cases critical sites could be verified by successful consecutive ablation. Mean mapping time was 19.4 ± 7.6 minutes, mean number of mapping points was 19,217 ± 10,270. Radiofrequency application until first effect was 165.1 ± 374.2 seconds; total procedure time was 157.6 ± 51.4 minutes, fluoroscopy time 21.7 ± 13.8 minutes, and total radiofrequency duration 1,016 ± 951.9 seconds, respectively. No severe complications occurred. CONCLUSION: Ultra high-density mapping of complex AT is safe and feasible. Further, it enables detailed insight into AT mechanisms. Critical AT sites can be identified precisely in order to guide successful catheter ablation.


Asunto(s)
Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Anciano , Ablación por Catéter/efectos adversos , Electrocardiografía , Estudios de Factibilidad , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radiografía Intervencional , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 26(7): 747-53, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25807878

RESUMEN

INTRODUCTION: Recently, a new image integration module (IIM, CartoUnivu™ Module) has been introduced to combine and merge fluoroscopy images with 3-dimensional-(3D)-electroanatomical maps (Carto® 3 System) into an accurate 3D view. The aim of the study was to investigate the influence of IIM on the fluoroscopy exposure during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial. METHODS AND RESULTS: Between June and November 2014, a total of 60 patients with PAF (73.3% male, 64.0 ± 9.2 years), who underwent PVI with the endpoint of unexcitability of the ablation line, were randomized to either a conventional 3D mapping system (Carto® 3 System) or to an additional IIM on the basis of an assumed reduction of fluoroscopy exposure by the use of IIM. There were no significant differences in baseline characteristics. The median ablation procedure time was identical in both groups (140.7 ± 27.8 minutes vs. 140.8 ± 39.5 minutes; P = 0.851). A significant decrease of mean fluoroscopy time from 11.9 ± 2.1 to 7.4 ± 2.6 minutes (P < 0.0006) and median fluoroscopy dose from 882.9 to 476.5 cGycm(2) (P < 0.001) was achieved. The main reduction of radiation could be realized during creation of the 3D-map. No major complications occurred during the procedures. After a median follow-up of 125.7 ± 45.6 days 80% of the patients were free from any atrial arrhythmias. CONCLUSION: CartoUnivu™ module easily integrates into the workflow of PVI with the endpoint of unexcitability of the ablation line without prolonging the procedure time. It is associated with a marked reduction in fluoroscopic dose when compared to a conventional 3D mapping system.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Intervencional/métodos , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estudios de Factibilidad , Femenino , Fluoroscopía , Alemania , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Flujo de Trabajo
18.
J Clin Med ; 12(19)2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37834948

RESUMEN

BACKGROUND: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. OBJECTIVE: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. METHODS: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. RESULTS: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62-95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. CONCLUSION: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.

19.
Arch Med Sci ; 16(5): 1022-1030, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32863990

RESUMEN

INTRODUCTION: Respiratory sinus arrhythmia (RSA) describes heart rate (HR) changes in synchrony with respiration. It is relevant for exercise capacity and mechanistically linked with the cardiac autonomic nervous system. After pulmonary vein isolation (PVI), the current therapy of choice for patients with paroxysmal atrial fibrillation (AF), the cardiac vagal tone is often diminished. We hypothesized that RSA is modulated by PVI in patients with paroxysmal AF. MATERIAL AND METHODS: Respiratory sinus arrhythmia, measured by using a deep breathing test and heart rate variability parameters, was studied in 10 patients (64 ±3 years) with paroxysmal AF presenting in stable sinus rhythm for their first catheter-based PVI. Additionally, heart rate dynamics before and after PVI were studied during sympathetic/parasympathetic coactivation by using a cold-face test. All tests were performed within 24 h before and 48 h after PVI. RESULTS: After PVI RSA (E/I difference: 7.9 ±1.0 vs. 3.5 ±0.6 bpm, p = 0.006; E/I ratio: 1.14 ±0.02 vs. 1.05 ±0.01, p = 0.003), heart rate variability (SDNN: 31 ±3 vs. 14 ±3 ms, p = 0.006; RMSSD: 17 ±2 vs. 8 ±2 ms, p = 0.002) and the HR response to sympathetic/parasympathetic coactivation (10.2 ±0.7% vs. 5.7 ±1.1%, p = 0.014) were diminished. The PVI-related changes in RSA correlated with the heart rate change during sympathetic/parasympathetic coactivation before vs. after PVI (E/I difference: r = 0.849, p = 0.002; E/I ratio: r = 0.786, p = 0.007). One patient with vagal driven arrhythmia experienced AF recurrence during follow-up (mean: 6.5 ±0.6 months). CONCLUSIONS: Respiratory sinus arrhythmia is reduced after PVI in patients with paroxysmal AF. Our findings suggest that this is related to a decrease in cardiac vagal tone. Whether and how this affects the clinical outcome including exercise capacity need to be determined.

20.
Eur J Med Res ; 25(1): 4, 2020 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-32183887

RESUMEN

BACKGROUND: Catheter ablation of non-reentrant, commonly termed "idiopathic" ventricular arrhythmias (VA) is highly effective in patients without structural heart disease (SHD). Meanwhile, the outcome of catheter ablation of these arrhythmias in patients with SHD remains unclear. This study sought to characterize the outcome of patients with and without SHD undergoing catheter ablation of non-reentrant VA. METHODS: In this single-centre study the acute and long-term outcome of 266 consecutive patients undergoing catheter ablation of non-reentrant VA was investigated. In 41.0% of patients a SHD was present (n = 109, 80.7% male, age 59.1 ± 14.7 years), 59.0% had no SHD (n = 157; 44.0% male, age 49.9 ± 16.5 years). RESULTS: Acute procedural success (absence of spontaneous or provoked VA at the end of procedure and within 48 h after the procedure) was achieved in 89.9% of patients with SHD vs. 94.3% without SHD (p = 0.238). During a mean follow-up of 34.7 ± 15.1 months a repeat catheter ablation was performed in 19.6% of patients with SHD vs. 13.0% without SHD (p = 0.179). Patients with dilated cardiomyopathy (DCM) were the most likely to require a repeat ablation procedure (32.0% of patients with DCM vs. 13.0% without SHD; p = 0.022). Periprocedural complications occurred in 5.5% of patients with SHD vs. 5.7% without SHD (p > 0.999). All complications were managed without sequelae. CONCLUSIONS: The outcome of catheter ablation of non-reentrant VA in patients with SHD appears good and is comparable to patients without SHD. A slightly higher rate of repeat ablations was observed in patients with DCM.


Asunto(s)
Cardiomiopatía Dilatada/cirugía , Ablación por Catéter , Cardiopatías/cirugía , Taquicardia Ventricular/cirugía , Adulto , Cardiomiopatía Dilatada/etiología , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA