RESUMEN
This study investigates the dissolution behavior of oxide layers containing radionuclides using perfluorocarbon (PFC) emulsion as a reusable medium. Chemicals such as PFC, anionic surfactant, and H2SO4 are used for preparing the PFC emulsion, and emulsified using an ultrasonication process. The FTIR results show O-H stretching that is formed by the interaction of the carboxyl group of the anionic surfactant with the hydroxyl group of water containing H2SO4, and find that the H2SO4 can be homogeneously dispersed in the PFC-anionic surfactant-H2SO4 emulsion. The dissolution test of the simulated Cr2O3 specimen is conducted using PFC emulsion containing KMnO4. Through the weight losses of specimens and Scanning Electron Microscope-Energy Dispersive X-ray Spectrometer (SEM-EDS) analysis, it is confirmed that the Cr2O3 layer on the SUS304 specimen is easily dissolved using PFC emulsion. During the dissolution of the Cr2O3, it is observed that the dispersed H2SO4-KMnO4 became unstable and separated from PFC emulsion. Based on these results, the behavior of the PFC emulsion during the dissolution of the oxide layer is explained.
Asunto(s)
Emulsiones , Fluorocarburos/química , Óxidos/química , Tensoactivos/química , Agua/químicaRESUMEN
We described the novel nanocomposite of silver doped ZrO2 combined graphene-based mesoporous silica (ZrO2-Ag-G-SiO2,) in bases of low-cost and self-assembly strategy. Synthesized ZrO2-Ag-G-SiO2 were characterized through X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDX), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), Raman spectroscopy, Nitrogen adsorption-desorption isotherms, X-ray photoelectron spectroscopy (XPS), and Diffuse Reflectance Spectroscopy (DRS). The ZrO2-Ag-G-SiO2 as an enzyme-free glucose sensor active material toward coordinate electro-oxidation of glucose was considered through cyclic voltammetry in significant electrolytes, such as phosphate buffer (PBS) at pH 7.4 and commercial urine. Utilizing ZrO2-Ag-G-SiO2, glucose detecting may well be finished with effective electrocatalytic performance toward organically important concentrations with the current reaction of 9.0 × 10-3 mAcm-2 and 0.05 mmol/L at the lowest potential of +0.2 V, thus fulfilling the elemental prerequisites for glucose detecting within the urine. Likewise, the ZrO2-Ag-G-SiO2 electrode can be worked for glucose detecting within the interferometer substances (e.g., ascorbic corrosive, lactose, fructose, and starch) in urine at proper pH conditions. Our results highlight the potential usages for qualitative and quantitative electrochemical investigation of glucose through the ZrO2-Ag-G-SiO2 sensor for glucose detecting within the urine concentration.
RESUMEN
The stabilization of decontamination foams containing a chemical reagent is a crucial requirement for their use in the decontamination of nuclear power plants. We have investigated the effects on decontamination foam stability of adding silica nanoparticles (NPs) modified with various functional groups, namely propyl (-CH3), amine (-NH2), and thiol (-SH) groups. The surface properties of these silica NPs were characterized with ATR-FTIR, solid NMR, and TGA analyses. We also established that the agglomeration in such foams of the amine-modified silica NPs is weaker than that of the other modified silica NPs due to their thorough dispersion in the liquid film. Further, the foam containing amine-modified silica NPs was found to be stable for 60 min at a pH of 2, i.e. under decontamination conditions. The bubble structure analysis showed that this decontamination foam has a bubble count that is approximately 5-8 times higher than the foams containing NPs modified with the other functional groups, which indicates that the decontamination foam with amine-modified silica NPs has the best foam structure of the three investigated foams. The well-dispersed and smaller amine-modified silica NPs enhance the foam stability by providing a barrier between the gas bubbles and delaying their coalescence. In contrast, the thiol- and propyl-modified silica NPs form aggregates with large diameters that reduce the maximum capillary pressure of coalescence and hence decrease the foam stability.
RESUMEN
The surfactant and colloidal nanoparticles has been considered for various applications because of interaction of both complex mixtures. The hydrophilic SiO2 nanoparticle could not be surface active behavior at the liquid/air interface. In this study, the SiO2 nanoparticles have been modified with 3-isocyanatopropyltriethoxy-silane (ICP), and the effect of foam stability has been investigated. The physical properties of surface modified SiO2 nanoparticle were analyzed by XRD, TGA, FT-IR, and SEM. After surface modification of SiO2 nanoparticles, the contact angle of SiO2 nanoparticle was also increased from 62° to 82° with increased ICP concentration. The experimental result has shown that SiO2 nanoparticle with ICP was positive effect and improved foam stability could be obtained at proper ICP concentration compared with un-modified SiO2 nanoparticle.
RESUMEN
In the present study, electrochemical sensing for urea was proposed utilizing graphene-based quaternary nanocomposites YInWO4-G-SiO2 (YIWGS). These YIWGS nanocomposites were utilized due to their exceptionally delicate determination of urea with the lowest detection limit (0.01 mM). These YIWGS composites were developed through a simple self-assembly method. From physical characterization, we found that the YIWGS composites are crystalline in nature (powdered X-ray diffraction), and Fourier transform infrared (FTIR) spectroscopy analysis provided the surface functionality and bonding. Scanning electron microscopy (SEM) studies indicated the morphology characteristics of the as-synthesized composites and the high-resolution transmission electron microscopy (HRTEM) image supported the formation of cubic or hexagonal morphology of the YIW nanocomposites. The YIWGS sensor showed a great electroanalytical sensing performance of 0.07 mM urea with a sensitivity of 0.06 mA cm-2, an expansive linear range of 0.7-1.5 mM with a linear response (R2 1/4 0.99), and an eminent reaction time of around 2 s. It also displayed a good linear response toward urea with negligible interferences from normal coinciding species in urine samples.