Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 23(2): 205-215, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33205201

RESUMEN

AIMS: Thermal injury to the oesophagus is an important cause of life-threatening complication after ablation for atrial fibrillation (AF). Thermal protection of the oesophageal lumen by infusing cold liquid reduces thermal injury to a limited extent. We tested the ability of a more powerful method of oesophageal temperature control to reduce the incidence of thermal injury. METHODS AND RESULTS: A single-centre, prospective, double-blinded randomized trial was used to investigate the ability of the ensoETM device to protect the oesophagus from thermal injury. This device was compared in a 1:1 randomization with a control group of standard practice utilizing a single-point temperature probe. In the protected group, the device maintained the luminal temperature at 4°C during radiofrequency (RF) ablation for AF under general anaesthesia. Endoscopic examination was performed at 7 days post-ablation and oesophageal injury was scored. The patient and the endoscopist were blinded to the randomization. We recruited 188 patients, of whom 120 underwent endoscopy. Thermal injury to the mucosa was significantly more common in the control group than in those receiving oesophageal protection (12/60 vs. 2/60; P = 0.008), with a trend toward reduction in gastroparesis (6/60 vs. 2/60, P = 0.27). There was no difference between groups in the duration of RF or in the force applied (P value range= 0.2-0.9). Procedure duration and fluoroscopy duration were similar (P = 0.97, P = 0.91, respectively). CONCLUSION: Thermal protection of the oesophagus significantly reduces ablation-related thermal injury compared with standard care. This method of oesophageal protection is safe and does not compromise the efficacy or efficiency of the ablation procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Esófago/cirugía , Humanos , Estudios Prospectivos , Temperatura , Resultado del Tratamiento
2.
Europace ; 21(6): 886-892, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30649275

RESUMEN

AIMS: Protamine sulfate is commonly used to reverse the action of heparin after catheter ablation procedures. Serious protamine-related adverse effect is rare, but its recognition and appropriate management by electrophysiologists and intensivists is important. Direct ventricular fibrillation (VF) soon after a slow infusion of protamine has not been clearly described. METHODS AND RESULTS: We examined the records of all patients who suffered apparent adverse events after protamine administration in our electrophysiology lab from 2013 to 2018. We describe a series of three patients, all of whom suffered a precipitous fall in arterial pressure followed by VF within minutes after administration of protamine following ablation for atrial fibrillation. The same supplier of protamine was used in all three cases, but they were from different batches. Serum tryptase levels were measured in all cases, immediately post-cardiac arrest and at 2- and 6-h post-event. Immunoglobulin levels were not measured. Two patients recovered after aggressive supportive therapy; the third died despite similar support. CONCLUSION: We have encountered three cases of profound hypotension followed by VF soon after administration of protamine. Although protamine is safe in a large majority of patients, these adverse events have led our centre to exercise greater selectivity and caution in its use.


Asunto(s)
Paro Cardíaco/inducido químicamente , Antagonistas de Heparina/efectos adversos , Protaminas/efectos adversos , Anciano , Fibrilación Atrial/cirugía , Ablación por Catéter , Resultado Fatal , Humanos , Masculino , Persona de Mediana Edad
3.
Pacing Clin Electrophysiol ; 42(10): 1383-1389, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31482579

RESUMEN

INTRODUCTION: Atrial fibrillation is often asymptomatic and un-diagnosed in the community resulting in an increased risk of heart failure and stroke to those patients. We evaluated the effectiveness, tolerability, and accuracy of a novel six-channel electrocardiogram digital-health screening device, the RhythmPad, for the detection of atrial fibrillation. METHODS: Seven hundred and fifty-two participants attending the cardiology department were recruited. Two recordings were taken-a six-lead electrocardiogram using the RhythmPad device and a standard 12-lead electrocardiogram. Recorded traces were analyzed by two blinded cardiologists. The computer-generated automated diagnostic reports from both systems were also compared. Post-participation feedback was obtained from study participants using a three-part questionnaire. RESULTS: The sensitivity of the six-lead electrocardiogram compared to the 12-lead electrocardiogram, analyzed by two blinded cardiologists, for the detection of normal sinus rhythm was 95.9%, with a specificity of 97.2%. The sensitivity for the detection of atrial fibrillation using the six-lead ECG was 93.4%, with specificity 96.8%. The six-lead automated diagnostic report had a sensitivity and specificity of 97.5% and 98.6%, respectively, for correctly diagnosing normal sinus rhythm. For the correct diagnosis of atrial fibrillation, the six-lead automated diagnostic report had a sensitivity and specificity of 95.4% and 98.8%, respectively. A total of 95.4% of participants found RhythmPad to be comfortable, with only 0.5% preferring the 12-lead ECG device in comparison to six-lead ECG acquisitions. CONCLUSION: The RhythmPad digital health device and its automated diagnostic report were highly accurate in detecting atrial fibrillation when compared to a standard 12-lead electrocardiogram.


Asunto(s)
Fibrilación Atrial/diagnóstico , Electrocardiografía/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Automatización , Diagnóstico Diferencial , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Encuestas y Cuestionarios
4.
Pacing Clin Electrophysiol ; 36(2): e45-7, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21453333

RESUMEN

We present a case of a 76-year-old man with ischemic cardiomyopathy. Cardiac magnetic resonance imaging demonstrated severe left ventricular (LV) impairment with possibility of scar formation. Cardiac resynchronization therapy was employed with the aid of a novel quadripolar LV lead. The quadripolar LV lead can be programmed for 10 different pacing configurations, allowing the electrophysiologist freedom to optimize the vector around scar and also avoid phrenic nerve stimulation without the requirement of LV lead repositioning.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Electrodos Implantados , Ventrículos Cardíacos/cirugía , Implantación de Prótesis/métodos , Disfunción Ventricular Izquierda/prevención & control , Anciano , Cicatriz Hipertrófica/patología , Cicatriz Hipertrófica/cirugía , Humanos , Masculino , Resultado del Tratamiento , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/cirugía
5.
Open Heart ; 10(2)2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37419525

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) and atrial fibrillation (AF) are increasing in prevalence globally and share common risk factors.Our aim was to characterise real-world evidence on direct oral anticoagulant (DOAC) prescribing for people with AF and CKD, in terms of adherence, persistence and renal dose titration. METHODS: PubMed, EMBASE and CINAHL were searched from inception to June 2022. Our search terms included a combination of Medical Subject Headings (MeSH) terms and keywords including 'atrial fibrillation', 'chronic kidney disease', 'adherence', 'persistence', 'direct oral anticoagulants' and 'dosing'. Data extraction and quality assessment were undertaken by two reviewers independently. Meta-analyses for pooled estimates were performed using DerSimonian and Laird random-effects models. Age, sex, diabetes, hypertension and heart failure were chosen as variables of interest. RESULTS: From 19 studies, a total of 252 117 patients were included with CKD and AF. Meta-analysis was only possible in seven studies with 128 406 patients, five on DOAC dose titration and two on adherence. There were insufficient studies on persistence. Our meta-analysis of dosing showed that 68% of patients with CKD and AF had correct dosing. There was no evidence to show any association between correct DOAC dosing and variables of interest. Overall, 67% of patients were DOAC adherent. CONCLUSION: Adherence and correct dosing of DOACs were suboptimal compared with other medications in the pooled studies with respect to CKD and AF. Thus, further research is required as the lack of generalisation of findings is a rate-limiting factor for improved DOAC management in AF and CKD. PROSPERO REGISTRATION NUMBER: CRD;42022344491.


Asunto(s)
Fibrilación Atrial , Insuficiencia Renal Crónica , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/epidemiología , Anticoagulantes , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/tratamiento farmacológico , Factores de Riesgo
6.
Expert Opin Pharmacother ; 23(8): 947-958, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35575484

RESUMEN

INTRODUCTION: Rheumatoid Arthritis (RA) is a chronic inflammatory disorder associated with an increased incidence and prevalence of cardiovascular disease (CVD), including myocardial infarction and heart failure. In addition to traditional risk factors, evidence suggests inflammation is critical to the pathophysiology of both conditions. Despite the association being well-recognised, challenges remain in managing cardiovascular risk in RA. AREAS COVERED: This manuscript analyses the association between CVD and RA and explores the limitations in evaluating cardiovascular risk in RA with available risk assessment tools. The authors review the optimal management of traditional risk factors such as hypertension and dyslipidaemia and contemporary risk factors such as inflammation and analyse the cardiovascular impact of RA medications. EXPERT OPINION: Analysis points to the critical role of inflammation in the pathogenesis of RA and CVD. It is well established that conventional disease-modifying anti-rheumatic drugs (DMARDs) improve cardiovascular outcomes; however, underlying risk often remains underappreciated. The authors suggest there remains an opportunity to improve mortality and morbidity with the early recognition and of at-risk populations and the timely initiation of appropriate cardiovascular and anti-inflammatory medications. More research is necessary into the role that imaging may play in stratifying risk and in the longer-term cardiovascular impact of biological DMARDs.


Asunto(s)
Antirreumáticos , Artritis Reumatoide , Enfermedades Cardiovasculares , Antirreumáticos/efectos adversos , Artritis Reumatoide/complicaciones , Artritis Reumatoide/tratamiento farmacológico , Artritis Reumatoide/epidemiología , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/prevención & control , Humanos , Inflamación/tratamiento farmacológico , Factores de Riesgo
7.
Arrhythm Electrophysiol Rev ; 11: e12, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35846422

RESUMEN

The burden of AF is increasing in prevalence and healthcare resource usage in the UK and worldwide. It can result in impaired quality of life for affected patients, as well as increased risk of stroke, heart failure and mortality. A holistic, integrated approach to AF management is recommended, which may include a focus on reducing risk factors and on medical management with anticoagulation and anti-arrhythmic drugs. There are also various ablation strategies that may be considered when anti-arrhythmic drugs fail to alleviate symptoms and reduce AF burden. These ablation techniques range from standalone percutaneous endocardial catheter ablation to open surgical ablation procedures concomitant with cardiac surgery. More recently, hybrid ablation that combines aspects of both surgical and electrophysiologically targeted ablation has been described. This article reviews the evolution of ablation strategies, beginning with the origin of the Cox maze IV procedure and continuing to the recent hybrid convergent approach, and provides a summary of the associated outcomes.

8.
Int Heart J ; 52(3): 146-52, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21646736

RESUMEN

We have shown that the gene SCN10A encoding the sodium channel Na(v)1.8 is a susceptibility factor for heart block and serious ventricular arrhythmia. Since Na(v)1.8 is known to be present in nerve fibres that mediate pain, it may be related to both cardiac pain and dysrhythmia. The localisation of Na(v)1.8 and other key nociceptive ion channels, including Na(v)1.7, Na(v)1.9, capsaicin receptor TRPV1, and purinergic receptor P2X(3), have not been reported in human heart. The aim of this study was to determine the distribution of Na(v)1.8, related sodium and other sensory channels in human cardiac tissue, and correlate their density with sympathetic nerves, regenerating nerves (GAP-43), and vascularity. Human heart atrial appendage tissues (n = 13) were collected during surgery for valve disease. Tissues were investigated by immunohistology using specific antibodies to Na(v)1.8 and other markers. Na(v)1.8 immunoreactivity was detected in nerve fibres and fascicles in the myocardium, often closely associated with small capillaries. Na(v)1.8 nerve fibres per mm(2) correlated significantly with vascular markers. Na(v)1.8-immunoreactivity was present also in cardiomyocytes with a similar distribution pattern to that seen with connexins, the specialised gap junction proteins of myocardial intercalated discs. Na(v)1.5-immunoreactivity was detected in cardiomyocytes but not in nerve fibres. Na(v)1.7, Na(v)1.9, TRPV1, P2X(3)/P2X(2), and GAP43 positive nerve fibres were relatively sparse, whereas sympathetic innervation and connexin43 were abundant. We conclude that sodium channel Na(v)1.8 is present in sensory nerves and cardiomyocytes of human heart. Na(v)1.8 and other pain channels provide new targets for the understanding and treatment of cardiac pain and dysrhythmia.


Asunto(s)
Corazón/inervación , Dolor/metabolismo , Canales de Sodio/metabolismo , Anciano , Anciano de 80 o más Años , Femenino , Proteína GAP-43/metabolismo , Humanos , Inmunohistoquímica , Masculino , Glicoproteínas de Membrana/metabolismo , Persona de Mediana Edad , Canal de Sodio Activado por Voltaje NAV1.8 , Fibras Nerviosas/metabolismo , Proteínas del Tejido Nervioso/metabolismo , Dolor/genética , Dolor/fisiopatología , Receptores Purinérgicos P2/metabolismo , Canales de Sodio/genética , Canales de Sodio/fisiología , Sistema Nervioso Simpático/metabolismo , Canales Catiónicos TRPV/metabolismo , Canales Catiónicos TRPV/fisiología
9.
J Clin Med ; 10(14)2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-34300301

RESUMEN

Atrial fibrillation (AF) is a global disease with rapidly rising incidence and prevalence. It is associated with a higher risk of stroke, dementia, cognitive decline, sudden and cardiovascular death, heart failure and impairment in quality of life. The disease is a major burden on the healthcare system. Paroxysmal AF is typically managed with medications or endocardial catheter ablation to good effect. However, a large proportion of patients with AF have persistent or long-standing persistent AF, which are more complex forms of the condition and thus more difficult to treat. This is in part due to the progressive electro-anatomical changes that occur with AF persistence and the spread of arrhythmogenic triggers and substrates outside of the pulmonary veins. The posterior wall of the left atrium is a common site for these changes and has become a target of ablation strategies to treat these more resistant forms of AF. In this review, we discuss the role of the posterior left atrial wall in persistent and long-standing persistent AF, the limitations of current endocardial-focused treatment strategies, and future perspectives on hybrid epicardial-endocardial approaches to posterior wall isolation or ablation.

10.
Arrhythm Electrophysiol Rev ; 10(3): 198-204, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34777825

RESUMEN

Recent advances have been made in AF treatment, including the role of early rhythm control and landmark clinical trials using ablation therapy. However, some treatment gaps remain, including the creation of durable lesions outside the pulmonary veins and effective treatment of longstanding persistent AF. A novel epicardial-endocardial ablation approach - the hybrid convergent procedure - was developed to combine surgical and catheter ablation techniques into a collaborative, multidisciplinary approach to managing AF. In this review, the authors discuss recently published data on hybrid convergent ablation, including results of the CONVERGE clinical trial, in the context of current challenges to treatment of persistent and long-standing persistent AF. The review also aims to provide perspective on outstanding questions and future directions in this area.

11.
Heart Rhythm ; 18(2): 303-312, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33045430

RESUMEN

The absence of strategies to consistently and effectively address nonparoxysmal atrial fibrillation by nonpharmacological interventions has represented a long-standing treatment gap. A combined epicardial/endocardial ablation strategy, the hybrid Convergent procedure, was developed in response to this clinical need. A subxiphoid incision is used to access the pericardial space facilitating an epicardial ablation directed at isolation of the posterior wall of the left atrium. This is followed by an endocardial ablation to complete isolation of the pulmonary veins and for additional ablation as needed. Experience gained with the hybrid Convergent procedure during the last decade has led to the development and adoption of strategies to optimize the technique and mitigate risks. Additionally, a surgical and electrophysiology "team" approach including comprehensive training is believed critical to successfully develop the hybrid Convergent program. A recently completed randomized clinical trial indicated that this ablation strategy is superior to an endocardial-only approach for patients with persistent atrial fibrillation. In this review, we propose and describe best practice guidelines for hybrid Convergent ablation on the basis of a combination of published data, author consensus, and expert opinion. A summary of clinical outcomes, emerging evidence, and future perspectives is also given.


Asunto(s)
Fibrilación Atrial/cirugía , Endocardio/cirugía , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Pericardio/cirugía , Guías de Práctica Clínica como Asunto , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Humanos , Recurrencia
12.
BMC Physiol ; 8: 8, 2008 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-18460209

RESUMEN

BACKGROUND: Cardiac insults such as ischemia, infarction, hypertrophy and dilatation are often accompanied by altered abundance and/or localization of the connexin43 gap junction protein, which may predispose towards arrhythmic complications. Models of chronic dyssynchronous cardiac activation have also been shown to result in redistribution of connexin43 in cardiomyocytes. We hypothesized that alterations in connexin43 expression and localization in the mouse heart might be induced by ventricular pacing over a short period of time. RESULTS: The subdiaphragmatic approach was used to pace a series of wild type mice for six hours before the hearts were removed for analysis. Mice were paced at 10-15% above their average anesthetized sinus rate and monitored to ensure 1:1 capture. Short-term pacing resulted in a significant reduction in connexin43 mRNA abundance, a partial redistribution of connexin43 from the sarcolemma to a non-sarcolemmal fraction, and accumulation of ubiquitinated connexin43 without a significant change in overall connexin43 protein levels. These early pacing-induced changes in connexin43 expression were not accompanied by decreased cardiac function, prolonged refractoriness or increased inducibility into sustained arrhythmias. CONCLUSION: Our data suggest that short-term pacing is associated with incipient changes in the expression of the connexin43 gap junction, possibly including decreased production and a slowed rate of degradation. This murine model may facilitate the study of early molecular changes induced by pacing and may ultimately assist in the development of strategies to prevent gap junction remodeling and the associated arrhythmic complications of cardiac disease.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Conexina 43/fisiología , Regulación de la Expresión Génica/fisiología , Sistema de Conducción Cardíaco/fisiología , Frecuencia Cardíaca/fisiología , Adaptación Fisiológica/fisiología , Animales , Ratones , Ratones Endogámicos C57BL , Factores de Tiempo , Distribución Tisular
14.
Heart Rhythm ; 4(8): 1034-45, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17675078

RESUMEN

BACKGROUND: Infarct border zone (IBZ) geometry likely affects inducibility and characteristics of postinfarction reentrant ventricular tachycardia, but the connection has not been established. OBJECTIVE: The purpose of this study was to determine characteristics of postinfarction ventricular tachycardia in the IBZ. METHODS: A geometric model describing the relationship between IBZ geometry and wavefront propagation in reentrant circuits was developed. Based on the formulation, slow conduction and block were expected to coincide with areas where IBZ thickness (T) is minimal and the local spatial gradient in thickness (DeltaT) is maximal, so that the degree of wavefront curvature rho proportional, variant DeltaT/T is maximal. Regions of fastest conduction velocity were predicted to coincide with areas of minimum DeltaT. In seven arrhythmogenic postinfarction canine heart experiments, tachycardia was induced by programmed stimulation, and activation maps were constructed from multichannel recordings. IBZ thickness was measured in excised hearts from histologic analysis or magnetic resonance imaging. Reentrant circuit properties were predicted from IBZ geometry and compared with ventricular activation maps after tachycardia induction. RESULTS: Mean IBZ thickness was 231 +/- 140 microm at the reentry isthmus and 1440 +/- 770 microm in the outer pathway (P <0.001). Mean curvature rho was 1.63 +/- 0.45 mm(-1) at functional block line locations, 0.71 +/- 0.18 mm(-1) at isthmus entrance-exit points, and 0.33 +/- 0.13 mm(-1) in the outer reentrant circuit pathway. The mean conduction velocity about the circuit during reentrant tachycardia was 0.32 +/- 0.04 mm/ms at entrance-exit points, 0.42 +/- 0.13 mm/ms for the entire outer pathway, and 0.64 +/- 0.16 mm/ms at outer pathway regions with minimum DeltaT. Model sensitivity and specificity to detect isthmus location was 75.0% and 97.2%. CONCLUSIONS: Reentrant circuit features as determined by activation mapping can be predicted on the basis of IBZ geometrical relationships.


Asunto(s)
Mapeo del Potencial de Superficie Corporal , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Modelos Cardiovasculares , Infarto del Miocardio/patología , Taquicardia Ventricular/fisiopatología , Animales , Perros , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética
15.
BMJ Case Rep ; 20172017 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-29070619

RESUMEN

Lasso catheter (Biosense Webster) is one of the most commonly employed circular mapping catheters during pulmonary vein isolation (PVI) procedure for atrial fibrillation (AF). Although this catheter has greatly facilitated arrhythmia mapping, it can be associated with serious complications. We report a case of a 59-year-old man who underwent PVI procedure for persistent AF. During the procedure, the Lasso catheter inadvertently slipped into the left ventricular cavity and entangled in the mitral valve apparatus. Various percutaneous manoeuvres to release the catheter were unsuccessful and the patient ultimately required emergency open heart surgery to remove the catheter and repair the valve. To the best of our knowledge, such a case has not previously been reported in the UK necessitating an immediate open heart surgery, avoiding replacement of the valve.


Asunto(s)
Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter/efectos adversos , Catéteres/efectos adversos , Válvula Mitral/patología , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Catéteres/normas , Remoción de Dispositivos/métodos , Urgencias Médicas , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Resultado del Tratamiento
16.
Glob Cardiol Sci Pract ; 2014(2): 53-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25405179

RESUMEN

Radiofrequency ablation (RFA) for the treatment of paroxysmal Atrial Fibrillation (pAF) has a class 1 indication in patients who have not tolerated or responded to antiarrhythmic medications. Antiarrhythmic medications (AAM) are, however, limited not only by modest efficacy, but also by significant side effects. Discontinuation rates for AAM range from 11-40% in trials. The RAAFT-2 trial evaluates the use of RFA as a first line treatment for pAF compared to optimal pharmacological management (1).

17.
Glob Cardiol Sci Pract ; 2013(2): 173-84, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24689018

RESUMEN

Atrial fibrillation is a common, global problem, with great personal, economic and social burdens. As populations age it increases in prevalence and becomes another condition that requires careful chronic management to ensure its effects are minimised. Assessment of the risk of stroke using well established risk prediction models is being aided by modern computerised databases and the choice of drugs to prevent strokes is ever expanding to try and improve the major cause of morbidity in AF. In addition, newer drugs for controlling rhythm are available and guidelines are constantly changing to reflect this. As well as medications, modern techniques of electrophysiology are becoming more widely embraced worldwide to provide more targeted treatment for the underlying pathophysiology. In this review we consider these factors to concisely describe how AF can be successfully managed.

18.
J Interv Card Electrophysiol ; 31(3): 225-35, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21505797

RESUMEN

PURPOSE: There is an increasing need for catheter ablation procedures to treat complex atrial tachycardias (AT) and atrial fibrillation (AF), often requiring detailed endocardial mapping. The sequential point-to-point contact mapping of complex arrhythmias is time-consuming and may not always be feasible. We assessed the utility of a novel spiral duo-decapolar high-density (HD) mapping catheter to delineate complex arrhythmia substrates for ablation. METHODS: The patients underwent HD mapping using a spiral catheter (AFocusII) and the EnSite NavX system, during catheter ablation procedures, to treat atrial arrhythmias. RESULTS: In 26 patients, a total of 32 atrial arrhythmias were mapped and ablated, comprising of five focal AT, eight macroreentrant AT, 11 persistent AF and eight paroxysmal AF. The HD catheter was used to acquire endocardial surface geometries in all cases and to map the pulmonary veins in patients undergoing AF ablation. In persistent AF, HD catheter mapping permitted the creation of highly detailed complex fractionated electrogram maps (left atrium 449 ± 128 points in 7.2 ± 2.6 min; right atrium 411 ± 113 points in 6.7 ± 1.6 min). In AT, activation mapping was performed with the acquisition of 305 ± 158 timing points in 7.3 ± 2.6 min, guiding successful ablation in all cases. During the follow-up of 7.0 ± 2.6 months, all AT patients remained free of significant arrhythmia. CONCLUSIONS: High-density contact mapping with a novel spiral multipolar catheter allows rapid assessment of focal and macroreentrant AT, and complex fractionated electrical activity in the atria. It has further multi-functional capabilities as a pulmonary vein mapping catheter and for accurate geometry creation when used with a 3D mapping system.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Cirugía Asistida por Computador/instrumentación , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/cirugía , Adulto , Anciano , Ecocardiografía Transesofágica , Electrocardiografía , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
19.
Glob Cardiol Sci Pract ; 2014(1): 2, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25054113
20.
Glob Cardiol Sci Pract ; 2014(3): 254-6, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25763378
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA