Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Pak Med Assoc ; 64(12): 1370-4, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25842580

RESUMEN

OBJECTIVES: To investigate the contribution of Bispectralindex monitoring on the amount of used anaesthetic substance and the quality of anaesthesia in patients with persistent atrial fibrillation who would undergo cardioversion. METHODS: The prospective, randomised, controlled clinical study was conducted at Akdeniz University, Antalya, Turkey from October 2010 to November 2011 Sedation was performed on 50 adult patients using midazolam and fentanyl. Patients were randomised to group 1 and 2. In group 1 cardioversion was performed when the BispectralIndex value was seen to have decreased to <80 and the Ramsay sedation score was 5-6. In Group 2, BispectralIndex monitor was blinded to the investigator, and cardioversion was performed when Ramsay sedation score was 5-6. In both groups, blood pressure, heart rate and Bispectral index values were recorded. Total anaesthetic amount, awareness and pain were also assessed. SPSS 13 was used for statistical analysis. RESULTS: Overall, 23(46%) patients were male and 27(54%) were female and there was no significant difference in the two groups in terms of age (p>0.05). No statistically significant difference was detected between the groups in terms of induction time, anaesthetic need and Bispectral Index values (p>0.05). In both groups, 2(8%) patients perceived pain and 2(8%) perceived the procedure. CONCLUSION: In the presence of anaesthetist in the team, Bispectral Index monitoring did not contribute to the determining of anaesthetic drug dosage and the depth and quality of anaesthesia in patients with persistent atrial fibrillation during cardioversion.


Asunto(s)
Fibrilación Atrial/terapia , Sedación Consciente , Monitores de Conciencia , Cardioversión Eléctrica , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
4.
Kardiochir Torakochirurgia Pol ; 13(1): 64-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27212985

RESUMEN

Central venous catheterization as a frequent routine clinical procedure may have significant complications. Mechanical complications may occur during catheter placement, whereas thromboembolic and infectious complications can be seen during follow-up. Total parenteral nutrition (TPN) associated central venous catheterizations may result in early mechanical complications and thrombotic and infectious complications in the long term. This paper describes a patient diagnosed as mitochondrial neurogastrointestinal encephalomyopathy requiring long-term central venous catheterization for TPN implementation, who had an infected thrombus on the catheter tip resected by cardiac surgery.

5.
Braz J Cardiovasc Surg ; 31(2): 178-82, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-27556320

RESUMEN

INTRODUCTION: To obtain the optimal anesthesia depth is not easy in cardiovascular surgery patients where the haemodynamic reserve is limited, due to reasons such as not being able to give the desired dose of anesthetic agent, or the change in the pharmacokinetics of the agent in the heart-lung machine. This study was planned to assess the contribution of bispectral index (BIS) monitoring in the depth of anesthesia. METHODS: The patients were divided into 2 groups, and BIS monitoring was used for each patient. Group 1 (G1 n=35): keeping the BIS monitor screen open, the anesthesia need was set. Group 2 (G2 n=35): BIS monitor was tied to the patient and the monitor screen was closed in such a way that the anaesthesist couldn't see the BIS value. When the recording time came, the data on the monitor was recorded. The need for the anesthetic agent was set according to the parameters such as haemodynamics or follow up of pupils, instead of BIS value, by titrating the anesthetic infusion doses. RESULTS: BIS values were similar in both groups before the induction, BIS values in both groups showed a decrease, showing no significant statistical difference (P>0.05). One patient in each group said that he dreamt, and one patient in G2 said that he had heard a noise and felt that he was taken from one place to another. CONCLUSION: The management should be done with clinical evaluation, haemodynamics and other monitorization methods and BIS monitoring findings together.


Asunto(s)
Monitores de Conciencia/estadística & datos numéricos , Puente de Arteria Coronaria/instrumentación , Despertar Intraoperatorio/diagnóstico , Monitoreo Intraoperatorio/métodos , Anciano , Anestésicos Intravenosos/administración & dosificación , Monitores de Conciencia/normas , Fentanilo/administración & dosificación , Hemodinámica , Humanos , Persona de Mediana Edad , Monitoreo Intraoperatorio/estadística & datos numéricos , Propofol/administración & dosificación
6.
Clin Respir J ; 10(3): 342-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-25307158

RESUMEN

BACKGROUND AND AIMS: Laparoscopic cholecystectomy has many advantages such as shorter hospital stay of patients, minimal postoperative pain, rapid recovery after the operation; however, systemic disadvantages because intra-abdominal pressure, position and general anaesthesia may also appear. In this study, pressure-controlled ventilation (PCV) and volume-controlled ventilation (VCV) modes during laparoscopic cholecystectomy operations were compared in terms of their effects on haemodynamic, respiratory and blood gas parameters. METHODS: Patients were randomly assigned to two groups according to the modes of mechanical ventilation, either to the PCV group, group P (35 patients) or to the VCV group, group V (35 patients). A standard electrocardiogram, pulse oximetry, non-invasive blood pressure, end-tidal CO2 , BIS and TOF monitoring were performed. Anaesthesia was induced with propofol, fentanyl and rocuronium. Anaesthesia was maintained with 50% O2 + 50% N2 O, propofol infusion and fentanyl. Haemodynamic data, respiratory parameters, arterial blood gases of the patients were measured. Dynamic compliance of the respiratory system, oxygenation index, alveolar-arterial oxygen gradient and dead space ventilation to tidal volume ratio were calculated. RESULTS: No difference was detected between the groups in terms of descriptive data, operation, anaesthesia, pneumoperitoneum and recovery period (P > 0.05). Haemodynamic data and blood gas values were compared between the two groups, and no significant difference was found (P < 0.05). After pneumoperitoneum, lung compliance decreased in both groups, more importantly in the Group P (P > 0.05). Tidal volume increased 10 min and 20 min after insufflation in the Group V (P < 0.05). Alveolar dead space ventilation to tidal volume ratio before pneumoperitoneum and alveolar-arterial oxygen gradient after pneumoperitoneum were significantly higher in the Group P compared to the Group V (P < 0.05). Dynamic compliance of the respiratory system was similar in both groups. CONCLUSION: In this study, with volume-controlled ventilation anaesthesia in laparoscopic cholecystectomy, higher tidal volume and lower alveolar-arterial oxygen gradient were achieved after pneumoperitoneum. These findings indicated that VCV mode can provide a better alveolar ventilation than PCV mode in laparoscopic cholecystectomy operations.


Asunto(s)
Colecistectomía Laparoscópica/métodos , Intercambio Gaseoso Pulmonar/fisiología , Respiración Artificial/métodos , Adulto , Análisis de los Gases de la Sangre , Hemodinámica , Humanos , Persona de Mediana Edad , Fenómenos Fisiológicos Respiratorios
7.
Rev. bras. cir. cardiovasc ; 31(2): 178-182, Mar.-Apr. 2016. tab
Artículo en Inglés | LILACS | ID: lil-792654

RESUMEN

Abstract Introduction: To obtain the optimal anesthesia depth is not easy in cardiovascular surgery patients where the haemodynamic reserve is limited, due to reasons such as not being able to give the desired dose of anesthetic agent, or the change in the pharmacokinetics of the agent in the heart-lung machine. This study was planned to assess the contribution of bispectral index (BIS) monitoring in the depth of anesthesia. Methods: The patients were divided into 2 groups, and BIS monitoring was used for each patient. Group 1 (G1 n=35): keeping the BIS monitor screen open, the anesthesia need was set. Group 2 (G2 n=35): BIS monitor was tied to the patient and the monitor screen was closed in such a way that the anaesthesist couldn't see the BIS value. When the recording time came, the data on the monitor was recorded. The need for the anesthetic agent was set according to the parameters such as haemodynamics or follow up of pupils, instead of BIS value, by titrating the anesthetic infusion doses. Results: BIS values were similar in both groups before the induction, BIS values in both groups showed a decrease, showing no significant statistical difference (P>0.05). One patient in each group said that he dreamt, and one patient in G2 said that he had heard a noise and felt that he was taken from one place to another. Conclusion: The management should be done with clinical evaluation, haemodynamics and other monitorization methods and BIS monitoring findings together.


Asunto(s)
Humanos , Persona de Mediana Edad , Anciano , Puente de Arteria Coronaria/instrumentación , Monitoreo Intraoperatorio/métodos , Monitores de Conciencia/estadística & datos numéricos , Despertar Intraoperatorio/diagnóstico , Propofol/administración & dosificación , Fentanilo/administración & dosificación , Monitoreo Intraoperatorio/estadística & datos numéricos , Anestésicos Intravenosos/administración & dosificación , Monitores de Conciencia/normas , Hemodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA