Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 75(10): 1141-1149, 2019.
Artículo en Japonés | MEDLINE | ID: mdl-31631107

RESUMEN

PURPOSE: Ichihara et al. (Fujita Med J 2015; 1(1): 9-14) developed a method to simultaneously obtain both coronary computed tomography (CT) angiography and CT myocardial perfusion (CTP) using 64-multi detector CT (MDCT). An input-function (time enhancement curve, TEC) of the ascending aorta (Ao) and myocardial CT density are necessary to calculate absolute myocardial blood flow (ml/g/min) using a two-compartment model. Helical scan starting timing is important to capture the peak (P) of Ao time enhancement curve (TEC). The purpose is to search the optimal timing of starting helical scan to capture the P. METHODS: We performed 14 CTPs using Definition AS+ (SIEMENS). A dynamic scan at the Ao level was started at 7 s after contrast injection and helical scan was started at various trigger on bolus tracking. Definition AS+ needs 2 s (other scanner may need 4 s) for changing from a dynamic to helical scan mode. We created TECs of pulmonary artery (PA) and Ao using the fifth function fitting. We measured the time from trigger point to the P (t200, t250, t300 and tCP). RESULTS: Mean t200, t250, t300 and tCP were 9.1±1.9, 7.9±2.0, 6.6±1.9 and 3.9±1.2 s, respectively. In additional other 16 CTP studies using the cross point method, we can capture the P in all (100%) examinations. CONCLUSION: Scan starting at the cross point is best for Definition AS+, and the Ao=300 HU may be best for other scanner that needs 4 s for changing scan mode to obtain a fine input function for calculating absolute myocardial blood flow.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Angiografía Coronaria , Tomografía Computarizada Espiral , Tomografía Computarizada Multidetector , Cintigrafía , Factores de Tiempo , Tomografía Computarizada por Rayos X
2.
Circ J ; 82(11): 2837-2844, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30175800

RESUMEN

BACKGROUND: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress 99 mTc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest 99 mTc-tetrofosmin/stress 201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera.Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. CONCLUSIONS: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.


Asunto(s)
Angiografía Coronaria , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica , Compuestos Organofosforados/administración & dosificación , Compuestos de Organotecnecio/administración & dosificación , Radioisótopos de Talio/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Anciano de 80 o más Años , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA