Eur Radiol ; 31(6): 4175-4183, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33211140

RESUMEN

OBJECTIVE: Assessing the advantage of x-ray dark-field contrast over x-ray transmission contrast in radiography for the detection of developing radiation-induced lung damage in mice. METHODS: Two groups of female C57BL/6 mice (irradiated and control) were imaged obtaining both contrasts monthly for 28 weeks post irradiation. Six mice received 20 Gy of irradiation to the entire right lung sparing the left lung. The control group of six mice was not irradiated. A total of 88 radiographs of both contrasts were evaluated for both groups based on average values for two regions of interest, covering (irradiated) right lung and healthy left lung. The ratio of these average values, R, was distinguished between healthy and damaged lungs for both contrasts. The time-point when deviations of R from healthy lung exceeded 3σ was determined and compared among contrasts. The Wilcoxon-Mann-Whitney test was used to test against the null hypothesis that there is no difference between both groups. A selection of 32 radiographs was assessed by radiologists. Sensitivity and specificity were determined in order to compare the diagnostic potential of both contrasts. Inter-reader and intra-reader accuracy were rated with Cohen's kappa. RESULTS: Radiation-induced morphological changes of lung tissue caused deviations from the control group that were measured on average 10 weeks earlier with x-ray dark-field contrast than with x-ray transmission contrast. Sensitivity, specificity, and accuracy doubled using dark-field radiography. CONCLUSION: X-ray dark-field radiography detects morphological changes of lung tissue associated with radiation-induced damage earlier than transmission radiography in a pre-clinical mouse model. KEY POINTS: • Significant deviations from healthy lung due to irradiation were measured after 16 weeks with x-ray dark-field radiography (p = 0.004). • Significant deviations occur on average 10 weeks earlier for x-ray dark-field radiography in comparison to x-ray transmission radiography. • Sensitivity and specificity doubled when using x-ray dark-field radiography instead of x-ray transmission radiography.


Asunto(s)
Pulmón , Animales , Femenino , Pulmón/diagnóstico por imagen , Ratones , Ratones Endogámicos C57BL , Radiografía , Sensibilidad y Especificidad , Rayos X
2.
Strahlenther Onkol ; 196(12): 1103-1115, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32748147

RESUMEN

BACKGROUND AND PURPOSE: Radiotherapy (RT) is persistently gaining significance in the treatment of pediatric tumors. However, individual features of a growing body and multifocal stages complicate this approach. Tomotherapy offers advantages in the treatment of anatomically complex tumors with low risks of side effects. Here we report on toxicity incidence and outcome of tomotherapy with a focus on multitarget RT (mtRT). MATERIALS AND METHODS: From 2008 to 2017, 38 children diagnosed with sarcoma were treated with tomotherapy. The median age was 15 years (6-19 years). Toxicity was graded according to the Common Terminology Criteria for Adverse Events v.4.03 and classified into symptoms during RT, acutely (0-6 months) and late (>6 months) after RT, and long-term sideeffects (>24 months). RESULTS: The main histologies were Ewing sarcoma (n = 23 [61%]) and alveolar rhabdomyosarcoma (n = 5 [13%]). RT was performed with a median total dose of 54 Gy (40.5-66.0 Gy) and a single dose of 2 Gy (1.80-2.27 Gy). Twenty patients (53%) received mtRT. Median follow-up was 29.7 months (95% confidence interval 15.3-48.2 months) with a 5-year survival of 55.2% (±9.5%). The 5­year survival rate of patients with mtRT (n = 20) was 37.1 ± 13.2%, while patients who received single-target RT (n = 18) had a 5-year survival rate of 75 ± 10.8%. Severe toxicities (grade 3 and 4) emerged in 14 patients (70%) with mtRT and 7 patients (39%) with single-target RT. Two non-hematological grade 4 toxicities occurred during RT: one mucositis and one radiodermatitis. After mtRT 5 patients had grade 3 toxicities acute and after single-target RT 4 patients. One patient had acute non-hematological grade 4 toxicities (gastritis, pericarditis, and pericardial effusion) after mtRT. Severe late effects of RT occurred in 2 patients after mtRT and in none of the single-target RT patients. No severe long-term side effects appeared. CONCLUSION: Our results showed acceptable levels of acute and late toxicities, considering the highly advanced diseases and multimodal treatment. Hence, tomotherapy is a feasible treatment method for young patients with anatomically complex tumors or multiple targets. Especially mtRT is a promising and innovative treatment approach for pediatric sarcomas, delivering unexpectedly high survival rates for patients with multifocal Ewing sarcomas in this study, whereby the limited number of patients should invariably be considered in the interpretation.


Asunto(s)
Radioterapia de Intensidad Modulada/métodos , Sarcoma/radioterapia , Adolescente , Neoplasias Óseas/radioterapia , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Radiodermatitis/etiología , Radioterapia de Intensidad Modulada/efectos adversos , Rabdomiosarcoma Alveolar/radioterapia , Sarcoma de Ewing/radioterapia , Adulto Joven
3.
BMC Cancer ; 20(1): 501, 2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-32487151

RESUMEN

BACKGROUND: The aim of our study was to assess the feasibility and oncologic outcomes in patients treated with spinal (SI) or craniospinal irradiation (CSI) in patients with leptomeningeal metastases (LM) and to suggest a prognostic score as to which patients are most likely to benefit from this treatment. METHODS: Nineteen patients treated with CSI at our institution were eligible for the study. Demographic data, primary tumor characteristics, outcome and toxicity were assessed retrospectively. The extent of extra-CNS disease was defined by staging CT-scans before the initiation of CSI. Based on outcome parameters a prognostic score was developed for stratification based on patient performance status and tumor staging. RESULTS: Median follow-up and overall survival (OS) for the whole group was 3.4 months (range 0.5-61.5 months). The median overall survival (OS) for patients with LM from breast cancer was 4.7 months and from NSCLC 3.3 months. The median OS was 7.3 months, 3.3 months and 1.5 months for patients with 0, 1 and 2 risk factors according to the proposed prognostic score (KPS < 70 and the presence of extra-CNS disease) respectively. Nonhematologic toxicities were mild. CONCLUSION: CSI demonstrated clinically meaningful survival that is comparable to the reported outcome of intrathecal chemotherapy. A simple scoring system could be used to better select patients for treatment with CSI in this palliative setting. In our opinion, the feasibility of performing CSI with modern radiotherapy techniques with better sparing of healthy tissue gives a further rationale for its use also in the palliative setting.


Asunto(s)
Irradiación Craneoespinal , Neoplasias Meníngeas/radioterapia , Cuidados Paliativos/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/mortalidad , Neoplasias de la Mama/patología , Neoplasias de la Mama/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/secundario , Toma de Decisiones Clínicas/métodos , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Masculino , Neoplasias Meníngeas/mortalidad , Neoplasias Meníngeas/secundario , Persona de Mediana Edad , Estadificación de Neoplasias , Selección de Paciente , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Strahlenther Onkol ; 195(6): 475-481, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30523417

RESUMEN

BACKGROUND: The goal of this study was to investigate if daily dose recalculations are necessary or if less time-consuming approaches can be used to identify dose differences to the planned dose in patients with head and neck cancers (H&N). METHODS: For 12 H&N patients treated with helical tomotherapy, daily dose calculations were performed retrospectively. Four different summation doses (SuDo) were calculated: DayDo (daily dose calculation), MVCTx2, MVCTx5, and MVCTx10 (dose calculations every second, fifth, and tenth fraction). Dose recalculations were depicted on the last contoured mega voltage CT (MVCT). The DayDo was compared to the planned dose and to the less time-consuming SuDo scenarios. The doses were assessed for the planning target volume (PTV) and the organs at risk (OARs): mandible (mand), spinal cord (SC), spinal cord +5 mm (SC+5 mm), parotid glands (PG). RESULTS: The ipsilateral PG, contralateral PG, and PTV volume decreased by -22.5% (range: -34.8 to 5.2%), -19.5% (-31.5 to 15.8%), and -2.6% (-16.7 to 0.2%), respectively. There was a significant median mean dose (Dmean) dose difference for DayDo compared to the planned dose for PG total of 1.9 Gy (-3.3 to 7.3 Gy). But less time-consuming SuDo compared to DayDo showed statistically significant but not clinically relevant (<2%) dose differences for several organs. Hence the small dose difference to the gold standard (DayDo), we recommend dose recalculations every fifth MVCT in order to identify the occurrence of dose differences compared to the planned dose. CONCLUSION: Daily dose calculations are the most precise to assess dose differences between actual and planned dose. Dose recalculations on every fifth MVCT (i. e., weekly control CTs) are an applicable and time-saving way of identifying patients with significant dose differences compared to the planned dose.


Asunto(s)
Neoplasias de Oído, Nariz y Garganta/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Factores de Tiempo
5.
J Neurooncol ; 127(3): 597-606, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26852221

RESUMEN

In this retrospective evaluation, we correlated radiation dose parameters with occurrence of optical radiation-induced toxicities. 213 meningioma patients received radiation between 2000 and 2013. Radiation dose and clinical data were extracted from planning systems and patients' files. The range of follow-up period was 2-159 months (median 75 months). Median age of patients was 60 years (range 23-86). There were 163 female and 50 male patients. In 140 cases, at least one of the neuro-optic structures (optic nerves and chiasm) was inside the irradiated target volumes. We found 15 dry eye (7 %) and 24 cataract (11.2 %) cases. Median dose to affected lachrymal glands was 1.47 Gy and median dose to affected lenses was 1.05 Gy. Age and blood cholesterol level in patients with cataract were significantly higher. Patients with dry eye were significantly older. Only two patients with visual problems attributable to radiation treatment were seen. They did not have any risk factors. Maximum and median delivered doses to neuro-optic structures were not higher than 57.30 and 54.60 Gy respectively. Low percentages of cases with radiation induced high grade optic toxicities show that modern treatment techniques and doses are safe. In very few patients with optic side effects, doses to organs at risk were higher than the defined constraint doses. This observation leads to the problem of additional risk factors coming into play. The role of risk factors and safety of higher radiation doses in high grade meningiomas should be investigated in more comprehensive studies.


Asunto(s)
Neoplasias Meníngeas/radioterapia , Meningioma/radioterapia , Enfermedades del Nervio Óptico/etiología , Nervio Óptico/efectos de la radiación , Traumatismos por Radiación/etiología , Radioterapia/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Neoplasias Meníngeas/patología , Meningioma/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Enfermedades del Nervio Óptico/diagnóstico , Pronóstico , Traumatismos por Radiación/diagnóstico , Dosificación Radioterapéutica , Estudios Retrospectivos , Adulto Joven
6.
BMC Cancer ; 15: 904, 2015 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-26573139

RESUMEN

BACKGROUND: The aim of the trial is to demonstrate that with the use of modern IMRT/IGRT and reduction of safety margins postoperative wound complications can be reduced. METHODS/ DESIGN: The trial is designed as a prospective, monocentric clinical phase II trial. The treatment is performed with helical IMRT on the Tomotherapy HiArt System© or with RapidArc© IMRT as available. All treatments are performed with 6 MV photons and daily online CT-based IGRT. A dose of 50 Gy in 2 Gy single fractions (5 fractions per week) is prescribed. Restaging including MRI of the primary tumor site as well as CT of the thorax/abdomen is planned 4 weeks after RT. PET-examinations or any other imaging can be performed as required clinically. In cases of R1 resection, brachytherapy is anticipated in the 2nd postoperative week. Brachytherapy catheters are implanted into the tumor bed depending on the size and location of the lesion. Surgery is planned 5-6 weeks after completion of neoadjuvant RT. All patients are seen for a first follow-up visit 2 weeks after wound healing is completed, thereafter every 3 months during the first 2 years. The endpoints of the study are evaluated in detail during the first (2 weeks) and second (3 months) follow-up. Functional outcome and QOL are documented prior to treatment and at year 1 and 2. Treatment response and efficacy will be scored according to the RECIST 1.1 criteria. A total patient number of 50 with an expected 20% rate of wound complications were calculated for the study, which translates into a 95% confidence interval of 10.0-33.7% for wound complication rate in a binomial distribution. DISCUSSION: The present study protocol prospectively evaluates the use of IMRT/IGRT for neoadjuvant RT in patients with soft tissue sarcomas of the extremity with the primary endpoint wound complications, which is the major concern with this treatment sequence. Besides complications rates, local control rates and survival rates, as well as QOL, functional outcome and treatment response parameters (imaging and pathology) are part of the protocol. The data of the present PREMISS study will enhance the current literature and support the hypothesis that neoadjuvant RT with IMRT/IGRT offers an excellent risk-benefit ratio in this patient population. TRIAL REGISTRATION: NCT01552239.


Asunto(s)
Terapia Neoadyuvante/métodos , Radioterapia de Intensidad Modulada/métodos , Sarcoma/radioterapia , Neoplasias de los Tejidos Blandos/radioterapia , Adulto , Braquiterapia/métodos , Relación Dosis-Respuesta en la Radiación , Extremidades , Femenino , Humanos , Masculino , Recurrencia Local de Neoplasia/radioterapia , Estudios Prospectivos , Radioterapia Adyuvante/métodos , Sarcoma/patología , Sarcoma/cirugía , Neoplasias de los Tejidos Blandos/patología , Neoplasias de los Tejidos Blandos/cirugía , Tasa de Supervivencia
7.
Strahlenther Onkol ; 190(8): 722-6, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24756138

RESUMEN

AIM: The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. METHODS: In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. RESULTS: A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were ≥ 8 mm in 13%, 5%, and 44% of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements ≥ 8 mm in 3%, 19%, and 1% of all setups; and ≥ 3 mm in 27%, 58%, and 18% of all fractions, respectively. For bone matching, the values were 1%, 1%, and 2% and 3%, 11%, and 34%, respectively. CONCLUSION: For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins ≤ 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Radioterapia Guiada por Imagen/métodos , Artefactos , Fraccionamiento de la Dosis de Radiación , Marcadores Fiduciales , Humanos , Masculino , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/métodos , Radioterapia de Intensidad Modulada/métodos
8.
Phys Med Biol ; 69(4)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38241727

RESUMEN

Objective.For fast neutron therapy with mixed neutron and gamma radiation at the fission neutron therapy facility MEDAPP at the research reactor FRM II in Garching, no clinical dose calculation software was available in the past. Here, we present a customized solution for research purposes to overcome this lack of three-dimensional dose calculation.Approach.The applied dose calculation method is based on two sets of decomposed pencil beam kernels for neutron and gamma radiation. The decomposition was performed using measured output factors and simulated depth dose curves and beam profiles in water as reference medium. While measurements were performed by applying the two-chamber dosimetry method, simulated data was generated using the Monte Carlo code MCNP. For the calculation of neutron dose deposition on CT data, tissue-specific correction factors were generated for soft tissue, bone, and lung tissue for the MEDAPP neutron spectrum. The pencil beam calculations were evaluated with reference to Monte Carlo calculations regarding accuracy and time efficiency.Main results.In water, dose distributions calculated using the pencil beam approach reproduced the input from Monte Carlo simulations. For heterogeneous media, an assessment of the tissue-specific correction factors with reference to Monte Carlo simulations for different tissue configurations showed promising results. Especially for scenarios where no lung tissue is present, the dose calculation could be highly improved by the applied correction method.Significance.With the presented approach, time-efficient dose calculations on CT data and treatment plan evaluations for research purposes are now available for MEDAPP.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tromboplastina , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Rayos gamma/uso terapéutico , Neutrones , Radiometría/métodos , Agua , Tomografía Computarizada por Rayos X , Método de Montecarlo , Algoritmos , Fantasmas de Imagen
9.
Z Med Phys ; 2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37225604

RESUMEN

In human radiotherapy a safety margin (PTV margin) is essential for successful irradiation and is usually part of clinical treatment planning. In preclinical radiotherapy research with small animals, most uncertainties and inaccuracies are present as well, but according to the literature a margin is used only scarcely. In addition, there is only little experience about the appropriate size of the margin, which should carefully be investigated and considered, since sparing of organs at risk or normal tissue is affected. Here we estimate the needed margin for preclinical irradiation by adapting a well-known human margin recipe from van Herck et al. to the dimensions and requirements of the specimen on a small animal radiation research platform (SARRP). We adjusted the factors of the described formula to the specific challenges in an orthotopic pancreatic tumor mouse model to establish an appropriate margin concept. The SARRP was used with its image-guidance irradiation possibility for arc irradiation with a field size of 10 × 10 mm2 for 5 fractions. Our goal was to irradiate the clinical target volume (CTV) of at least 90% of our mice with at least 95% of the prescribed dose. By carefully analyzing all relevant factors we gain a CTV to planning target volume (PTV) margin of 1.5 mm for our preclinical setup. The stated safety margin is strongly dependent on the exact setting of the experiment and has to be adjusted for other experimental settings. The few stated values in literature correspond well to our result. Even if using margins in the preclinical setting might be an additional challenge, we think it is crucial to use them to produce reliable results and improve the efficacy of radiotherapy.

10.
Comp Med ; 72(5): 336-341, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36127130

RESUMEN

Small-animal irradiators are widely used in oncologic research, and many experiments use mice to mimic radiation treatments in humans. To improve fractionated high-precision irradiation in mice with orthotopic pancreatic tumors, we evaluated 3 positioning methods: no positioning aid, skin marker, and immobilization devices (immobilization masks). We retrospectively evaluated the translation vector needed for optimal tumor alignment (by shifting the mouse in left-right, in cranio-caudal, and in anterior-posterior direction) on cone-beam CT from our small-animal radiotherapy system. Of the 3 methods, the skin marker method yielded the smallest mean translation vector (3.8 mm) and was the most precise method overall for most of the mice. In addition, the skin marker method required supplemental rotation (that is, roll, pitch, and yaw) for optimal tumor alignment only half as often as positioning without a positioning aid. Finally, the skin marker method had the highest scores for the quality of the fusion results. Overall, we preferred the skin marker method over the other 2 positioning methods with regard to optimal treatment planning and radiotherapy in an orthotopic mouse model of pancreatic cancer.


Asunto(s)
Neoplasias Pancreáticas , Planificación de la Radioterapia Asistida por Computador , Humanos , Animales , Ratones , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias Pancreáticas/radioterapia , Modelos Animales de Enfermedad , Neoplasias Pancreáticas
11.
Phys Med Biol ; 67(13)2022 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-35679845

RESUMEN

Objective.Dual energy computed tomography (DECT) has been shown to provide additional image information compared to conventional CT and has been used in clinical routine for several years. The objective of this work is to present a DECT implementation for a Small Animal Radiation Research Platform (SARRP) and to verify it with a quantitative analysis of a material phantom and a qualitative analysis with anex-vivomouse measurement.Approach.For dual energy imaging, two different spectra are required, but commercial small animal irradiators are usually not optimized for DECT. We present a method that enables dual energy imaging on a SARRP with sequential scanning and an Empirical Dual Energy Calibration (EDEC). EDEC does not require the exact knowledge of spectra and attenuation coefficients; instead, it is based on a calibration. Due to the SARRP geometry and reconstruction algorithm, the calibration is done using an artificial CT image based on measured values. The calibration yields coefficients to convert the measured images into material decomposed images.Main results.To analyze the method quantitatively, the electron density and the effective atomic number of a material phantom were calculated and compared with theoretical values. The electron density showed a maximum deviation from the theoretical values of less than 5% and the atomic number of slightly more than 6%. For use in mice, DECT is particularly useful in distinguishing iodine contrast agent from bone. A material decomposition of anex-vivomouse with iodine contrast agent was material decomposed to show that bone and iodine can be distinguished and iodine-corrected images can be calculated.Significance.DECT is capable of calculating electron density images and effective atomic number images, which are appropriate parameters for quantitative analysis. Furthermore, virtual monochromatic images can be obtained for a better differentiation of materials, especially bone and iodine contrast agent.


Asunto(s)
Medios de Contraste , Yodo , Animales , Calibración , Ratones , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos
12.
Z Med Phys ; 32(3): 261-272, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35370028

RESUMEN

In the field of preclinical radiotherapy, many new developments were driven by technical innovations. To make research of different groups comparable in that context and reliable, high quality has to be maintained. Therefore, standardized protocols and programs should be used. Here we present a guideline for a comprehensive and efficient quality assurance program for an image-guided small animal irradiation system, which is meant to test all the involved subsystems (imaging, treatment planning, and the irradiation system in terms of geometric accuracy and dosimetric aspects) as well as the complete procedure (end-to-end test) in a time efficient way. The suggestions are developed on a Small Animal Radiation Research Platform (SARRP) from Xstrahl (Xstrahl Ltd., Camberley, UK) and are presented together with proposed frequencies (from monthly to yearly) and experiences on the duration of each test. All output and energy related measurements showed stable results within small variation. Also, the motorized parts (couch, gantry) and other geometrical alignments were very stable. For the checks of the imaging system, the results are highly dependent on the chosen protocol and differ according to the settings. We received nevertheless stable and comparably good results for our mainly used protocol. All investigated aspects of treatment planning were exactly fulfilled and also the end-to-end test showed satisfying values. The mean overall time we needed for our checks to have a well monitored machine is less than two hours per month.


Asunto(s)
Radiometría , Radioterapia Guiada por Imagen , Animales , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos
13.
J Appl Clin Med Phys ; 12(4): 3596, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22089018

RESUMEN

Intensity-modulated radiation therapy (IMRT) requires more beam-on time than normal open field treatment. Consequently, the machines wear out and need more spare parts. A helical tomotherapy treatment unit needs a periodical tungsten target replacement, which is a time consuming event. To be able to predict the next replacement would be quite valuable. We observed unexpected variations towards the end of the target lifetime in the performed pretreatment measurements for patient plan verification. Thus, we retrospectively analyze the measurements of our quality assurance program. The time dependence of the quotient of two simultaneous dose measurements at different depths within a phantom for a fixed open field irradiation is evaluated. We also assess the time-dependent changes of an IMRT plan measurement and of a relative depth dose curve measurement. Additionally, we performed a Monte Carlo simulation with Geant4 to understand the physical reasons for the measured values. Our measurements show that the dose at a specified depth compared to the dose in shallower regions of the phantom declines towards the end of the target lifetime. This reproducible effect can be due to the lowering of the mean energy of the X-ray spectrum. These results are supported by the measurements of the IMRT plan, as well as the study of the relative depth dose curve. Furthermore, the simulation is consistent with these findings since it provides a possible explanation for the reduction of the mean energy for thinner targets. It could be due to the lowering of low energy photon self-absorption in a worn out and therefore thinner target. We state a threshold value for our measurement at which a target replacement should be initiated. Measurements to observe a change in the energy are good predictors of the need for a target replacement. However, since all results support the softening of the spectrum hypothesis, all depth-dependent setups are viable for analyzing the deterioration of the tungsten target. The suggested measurements and criteria to replace the target can be very helpful for every user of a TomoTherapy machine.


Asunto(s)
Radioterapia de Intensidad Modulada/métodos , Humanos , Método de Montecarlo , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica
14.
Cancers (Basel) ; 13(22)2021 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-34830813

RESUMEN

Pancreatic ductal adenocarcinoma (PDAC) is one of the most lethal human cancers. Innovative treatment concepts may enhance oncological outcome. Clinically relevant tumor models are essential in developing new therapeutic strategies. In the present study, we used two human PDAC cell lines for an orthotopic xenograft mouse model and compared treatment characteristics between this in vivo tumor model and PDAC patients. Tumor-bearing mice received stereotactic high-precision irradiation using arc technique after 3D-treatment planning. Induction of DNA damage in tumors and organs at risk (OARs) was histopathologically analyzed by the DNA damage marker γH2AX and compared with results after unprecise whole-abdomen irradiation. Our mouse model and preclinical setup reflect the characteristics of PDAC patients and clinical RT. It was feasible to perform stereotactic high-precision RT after defining tumor and OARs by CT imaging. After stereotactic RT, a high rate of DNA damage was mainly observed in the tumor but not in OARs. The calculated dose distributions and the extent of the irradiation field correlate with histopathological staining and the clinical example. We established and validated 3D-planned stereotactic RT in an orthotopic PDAC mouse model, which reflects the human RT. The efficacy of the whole workflow of imaging, treatment planning, and high-precision RT was proven by longitudinal analysis showing a significant improved survival. Importantly, this model can be used to analyze tumor regression and therapy-related toxicity in one model and will allow drawing clinically relevant conclusions.

15.
Radiat Oncol ; 15(1): 253, 2020 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-33138837

RESUMEN

BACKGROUND: The ESCALOX trial was designed as a multicenter, randomized prospective dose escalation study for head and neck cancer. Therefore, feasibility of treatment planning via different treatment planning systems (TPS) and radiotherapy (RT) techniques is essential. We hypothesized the comparability of dose distributions for simultaneous integrated boost (SIB) volumes respecting the constraints by different TPS and RT techniques. METHODS: CT data sets of the first six patients (all male, mean age: 61.3 years) of the pre-study (up to 77 Gy) were used for comparison of IMRT, VMAT, and helical tomotherapy (HT). Oropharynx was the primary tumor location. Normalization of the three step SIB (77 Gy, 70 Gy, 56 Gy) was D95% = 77 Gy. Coverage (CVF), healthy tissue conformity index (HTCI), conformation number (CN), and dose homogeneity (HI) were compared for PTVs and conformation index (COIN) for parotids. RESULTS: All RT techniques achieved good coverage. For SIB77Gy, CVF was best for IMRT and VMAT, HT achieved highest CN followed by VMAT and IMRT. HT reached good HTCI value, and HI compared to both other techniques. For SIB70Gy, CVF was best by IMRT. HTCI favored HT, consequently CN as well. HI was slightly better for HT. For SIB56Gy, CVF resulted comparably. Conformity favors VMAT as seen by HTCI and CN. Dmean of ipsilateral and contralateral parotids favor HT. CONCLUSION: Different TPS for dose escalation reliably achieved high plan quality. Despite the very good results of HT planning for coverage, conformity, and homogeneity, the TPS also achieved acceptable results for IMRT and VMAT. Trial registration ClinicalTrials.gov Identifier: NCT01212354, EudraCT-No.: 2010-021139-15. ARO: ARO 14-01.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Estudios Prospectivos , Dosificación Radioterapéutica
16.
Radiat Oncol J ; 37(2): 127-133, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31137087

RESUMEN

PURPOSE: The aim of this study was to identify volume changes and dose variations of rectum and bladder during radiation therapy in prostate cancer (PC) patients. MATERIALS AND METHODS: We analyzed 20 patients with PC treated with helical tomotherapy. Daily image guidance was performed. We re-contoured the entire bladder and rectum including its contents as well as the organ walls on megavoltage computed tomography once a week. Dose variations were analyzed by means of Dmedian, Dmean, Dmax, V10 to V75, as well as the organs at risk (OAR) volume. Further, we investigated the correlation between volume changes and changes in Dmean of OAR. RESULTS: During treatment, the rectal volume ranged from 62% to 223% of its initial volume, the bladder volume from 22% to 375%. The average Dmean ranged from 87% to 118% for the rectum and 58% to 160% for the bladder. The Pearson correlation coefficients between volume changes and corresponding changes in Dmean were -0.82 for the bladder and 0.52 for the rectum. The comparison of the dose wall histogram (DWH) and the dose volume histogram (DVH) showed that the DVH underestimates the percentage of the rectal and bladder volume exposed to the high dose region. CONCLUSION: Relevant variations in the volume of OAR and corresponding dose variations can be observed. For the bladder, an increase in the volume generally leads to lower doses; for the rectum, the correlation is weaker. Having demonstrated remarkable differences in the dose distribution of the DWH and the DVH, the use of DWHs should be considered.

17.
Radiat Oncol ; 14(1): 135, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31370876

RESUMEN

PURPOSE/OBJECTIVE(S): Along with breast-conserving surgery (BCS), adjuvant radiotherapy (RT) of patients with early breast cancer plays a crucial role in the oncologic treatment concept. Conventionally, irradiation is carried out with the aid of tangentially arranged fields. However, more modern and more complex radiation techniques such as IMRT (intensity-modulated radio therapy) are used more frequently, as they improve dose conformity and homogeneity and, in some cases, achieve better protection of adjacent risk factors. The use of this technique has implications for the incidental- and thus unintended- irradiation of adjacent loco regional lymph drainage in axillary lymph node levels I-III and internal mammary lymph nodes (IMLNs). A comparison of a homogeneous "real-life" patient collective, treated with helical tomotherapy (TT), patients treated with 3D conformal RT conventional tangentially arranged fields (3DCRT) and deep inspiration breath hold (3DCRT-DIBH), was conducted. MATERIALS/METHODS: This study included 90 treatment plans after BCS, irradiated in our clinic from January 2012 to August 2016 with TT (n = 30) and 3D-CRT (n = 30), 3DCRT DIBH (n = 30). PTVs were contoured at different time points by different radiation oncologists (> 7). TT was performed with a total dose of 50.4 Gy and a single dose of 1.8 Gy with a simultaneous integrated boost (SIB) to the tumor cavity (TT group). Patients irradiated with 3DCRT/3DCRT DIBH received 50 Gy à 2 Gy and a sequential boost. Contouring of lymph drainage routes was performed retrospectively according to RTOG guidelines. RESULTS: Average doses (DMean) in axillary lymph node Level I/Level II/Level III were 31.6 Gy/8.43 Gy/2.38 Gy for TT, 24.0 Gy/11.2 Gy/3.97 Gy for 3DCRT and 24.7 Gy/13.3 Gy/5.59 Gy for 3DCRT-DIBH patients. Internal mammary lymph nodes (IMLNs) Dmean were 27.8 Gy (TT), 13.5 Gy (3DCRT), and 18.7 Gy (3DCRT-DIBH). Comparing TT to 3DCRT-DIBH dose varied significantly in all axillary lymph node levels and the IMLNs. Comparing TT to 3DCRT significant dose difference in Level I and IMLNs was observed. CONCLUSION: Dose applied to locoregional lymph drainage pathways varies comparing tomotherapy plans to conventional tangentially arranged fields. Studies are warranted whether dose variations influence loco-regional spread and must have implications for target volume definition guidelines.


Asunto(s)
Neoplasias de la Mama/radioterapia , Ganglios Linfáticos/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/prevención & control , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Adyuvante/normas , Radioterapia Conformacional/normas , Contencion de la Respiración , Femenino , Humanos , Persona de Mediana Edad , Pronóstico , Dosificación Radioterapéutica , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada , Estudios Retrospectivos
18.
Radiat Oncol ; 14(1): 2, 2019 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-30626408

RESUMEN

BACKGROUND: Advanced radiotherapy (RT) techniques allow normal tissue to be spared in patients with extremity soft tissue sarcoma (STS). This work aims to evaluate toxicity and outcome after neoadjuvant image-guided radiotherapy (IGRT) as helical intensity modulated radiotherapy (IMRT) with reduced margins based on MRI-based target definition in patients with STS. METHODS: Between 2010 to 2014, 41 patients with extremity STS were treated with IGRT delivered as helical IMRT on a tomotherapy machine. The tumor site was in the upper extremity in 6 patients (15%) and lower extremity in 35 patients (85%). Reduced margins of 2.5 cm in longitudinal direction and 1.0 cm in axial direction were used to expand the MRI-defined gross tumor volume, including peritumoral edema, to the clinical target volume. An additional margin of 5 mm was added to receive the planning target volume. The full total dose of 50 Gy in 2 Gy fractions was sucessfully applied in 40 patients. Two patients received chemotherapy instead of surgery due to systemic progression. All patients were included into a strict follow-up program and were seen interdisciplinarily by the Departments of Orthopaedic Surgery and Radiation Oncology. RESULTS: Thirty eight patients that received total RT total dose and subsequent resection were analyzed for outcome. After a median follow-up of 38.5 months cumulative OS, local PFS and systemic PFS at 2 years were determined at 78.2, 85.2 and 54.5%, respectively. Two of 6 local recurrences were proximal marginal misses. Negative resection margins were achieved in 84% of patients. The rate of major wound complications was comparable to previous IMRT studies with 36.8%. RT was overall tolerable with low toxicity rates. CONCLUSIONS: IMRT-IGRT offers neoadjuvant treatment for extremity STS with reduced safety margins and thus low toxicity rates. Wound complication rates were comparable to previously reported frequencies. Two reported marginal misses suggest a word of caution for reduction of longitudinal safety margins.


Asunto(s)
Extremidades/efectos de la radiación , Terapia Neoadyuvante/métodos , Recurrencia Local de Neoplasia/radioterapia , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Sarcoma/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Extremidades/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Pronóstico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Adyuvante , Sarcoma/patología , Tasa de Supervivencia , Adulto Joven
19.
Z Med Phys ; 28(4): 303-309, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29858132

RESUMEN

The aim of this study was to investigate a single crystal diamond detector, the microDiamond detector from PTW (PTW-Freiburg, Freiburg, Germany), concerning the particular requirements in the set-up and energy range used in small animal radiotherapy (RT) research (around 220kV). We tested it to find out the minimal required pre-irradiation dose, the dose linearity, dose rate dependency and the angular response as well as usability in the small animal radiation research platform, SARRP (Xstrahl Ltd., Camberley, UK). For a stable signal in the range of energies used in the study, we found a required pre-irradiation dose of 10Gy. The dose linearity and dose rate dependence measurements showed a very good performance of the microDiamond detector. Regarding the effect of angular dependency, the variation of the response signal is less than 0.5% within the first 15° of the polar angle. In the azimuthal angle, however, there are differences in detector response up to 20%, depending on the range of energies used in the study. In addition, we compared the detector to a radiosensitive film for a profile measurement of a 5×5mm2 irradiation field. Both methods showed a good accordance with the field size, however, the film has a steeper dose gradient in the penumbra region but also a higher noise than the microDiamond detector. We demonstrated that the microDiamond detector is a useful measurement tool for small animal RT research due to its small size. Nevertheless, it seems to be very important to verify the response of the detector in the given set-up and energy range.


Asunto(s)
Dosímetros de Radiación , Radiometría/instrumentación , Radiometría/métodos , Diamante , Rayos X
20.
Radiat Oncol ; 13(1): 31, 2018 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-29471879

RESUMEN

BACKGROUND: Tumor-Treating Fields (TTFields) are a novel treatment strategy for glioblastoma (GBM) that is approved for the use concomitantly to adjuvant chemotherapy. Preclinical data suggest a synergistic interaction of TTFields and radiotherapy (RT). However, the dosimetric uncertainties caused by the highly dense arrays have led to caution of applying the TTF setup during RT. METHODS: In a RW3 slab phantom we compared the MV- and kV-CT based planned dose with the measured dose. VMAT-plans were optimized on MV-CTs of an Alderson head phantom without TTF arrays and then re-calculated on the same phantom equipped with TTF arrays. Dose at organs at risk (OAR) and target volumes (PTVs) were compared. RESULTS: Measurements at a depth of 2, 3 and 4 cm of a RW 3 slab phantom show an attenuation due to TTField arrays of 3.4, 3.7 and 2.7% respectively. This was in-line with calculated attenuations based on MV-CT (1.2, 2.5 and 2.5%) but not with the attenuation expected from kV-CT based calculations (7.1, 8.2 and 8.6%). Consecutive MV-CT based VMAT planning and re-calculation reveals, that the conformity and homogeneity are not affected by the presence of TTField arrays. The dose at organs at risk (OAR) can show increases or decreases by < 0.5 Gy, which should be considered especially in cases next to the scull base. CONCLUSION: MV-CT based dose calculation results in reliable dose distributions also in the presence of TTField arrays. There is a small but clinically not relevant interaction between the TTField arrays and VMAT dose application. Thus, daily replacement of TTField arrays is not necessary in regard to deeply located OARs. RT is feasible, when a VMAT treatment plan is optimized to an array free planning CT. As the biologic effect of a concomitant treatment especially on OARs is currently unknown, a concomitant treatment should be performed only within clinical trials.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Glioblastoma/radioterapia , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Transductores , Terapia por Estimulación Eléctrica/instrumentación , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica