Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 92(1): 319-331, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38308149

RESUMEN

PURPOSE: This study addresses the challenge of low resolution and signal-to-noise ratio (SNR) in diffusion-weighted images (DWI), which are pivotal for cancer detection. Traditional methods increase SNR at high b-values through multiple acquisitions, but this results in diminished image resolution due to motion-induced variations. Our research aims to enhance spatial resolution by exploiting the global structure within multicontrast DWI scans and millimetric motion between acquisitions. METHODS: We introduce a novel approach employing a "Perturbation Network" to learn subvoxel-size motions between scans, trained jointly with an implicit neural representation (INR) network. INR encodes the DWI as a continuous volumetric function, treating voxel intensities of low-resolution acquisitions as discrete samples. By evaluating this function with a finer grid, our model predicts higher-resolution signal intensities for intermediate voxel locations. The Perturbation Network's motion-correction efficacy was validated through experiments on biological phantoms and in vivo prostate scans. RESULTS: Quantitative analyses revealed significantly higher structural similarity measures of super-resolution images to ground truth high-resolution images compared to high-order interpolation (p < $$ < $$ 0.005). In blind qualitative experiments, 96 . 1 % $$ 96.1\% $$ of super-resolution images were assessed to have superior diagnostic quality compared to interpolated images. CONCLUSION: High-resolution details in DWI can be obtained without the need for high-resolution training data. One notable advantage of the proposed method is that it does not require a super-resolution training set. This is important in clinical practice because the proposed method can easily be adapted to images with different scanner settings or body parts, whereas the supervised methods do not offer such an option.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética , Fantasmas de Imagen , Próstata , Neoplasias de la Próstata , Relación Señal-Ruido , Humanos , Masculino , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Próstata/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Asistida por Computador/métodos , Redes Neurales de la Computación , Movimiento (Física) , Reproducibilidad de los Resultados
2.
Radiology ; 305(2): 399-407, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35880981

RESUMEN

Background Variability of acquisition and interpretation of prostate multiparametric MRI (mpMRI) persists despite implementation of the Prostate Imaging Reporting and Data System (PI-RADS) version 2.1 due to the range of reader experience and subjectivity of lesion characterization. A quantitative method, hybrid multidimensional MRI (HM-MRI), may introduce objectivity. Purpose To compare performance, interobserver agreement, and interpretation time of radiologists using mpMRI versus HM-MRI to diagnose clinically significant prostate cancer. Materials and Methods In this retrospective analysis, men with prostatectomy or MRI-fused transrectal US biopsy-confirmed prostate cancer underwent mpMRI (triplanar T2-weighted, diffusion-weighted, and dynamic contrast-enhanced imaging) and HM-MRI (with multiple echo times and b value combinations) from August 2012 to February 2020. Four readers with 1-20 years of experience interpreted mpMRI and HM-MRI examinations independently, with a 4-week washout period between interpretations. PI-RADS score, lesion location, and interpretation time were recorded. mpMRI and HM-MRI interpretation time, interobserver agreement (Cronbach alpha), and performance of area under the receiver operating characteristic curve (AUC) analysis were compared for each radiologist with use of bootstrap analysis. Results Sixty-one men (mean age, 61 years ± 8 [SD]) were evaluated. Per-patient AUC was higher for HM-MRI for reader 4 compared with mpMRI (AUCs for readers 1-4: 0.61, 0.71, 0.59, and 0.64 vs 0.66, 0.60, 0.50, and 0.46; P = .57, .20, .32, and .04, respectively). Per-patient specificity was higher for HM-MRI for readers 2-4 compared with mpMRI (specificity for readers 1-4: 48%, 78%, 48%, and 46% vs 37%, 26%, 0%, and 7%; P = .34, P < .001, P < .001, and P < .001, respectively). Diagnostic performance improved for the reader least experienced with HM-MRI, reader 4 (AUC, 0.64 vs 0.46; P = .04). HM-MRI interobserver agreement (Cronbach alpha = 0.88 [95% CI: 0.82, 0.92]) was higher than that of mpMRI (Cronbach alpha = 0.26 [95% CI: 0.10, 0.52]; α > .60 indicates reliability; P = .03). HM-MRI mean interpretation time (73 seconds ± 43 [SD]) was shorter than that of mpMRI (254 seconds ± 133; P = .03). Conclusion Radiologists had similar or improved diagnostic performance, higher interobserver agreement, and lower interpretation time for clinically significant prostate cancer with hybrid multidimensional MRI than multiparametric MRI. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Persona de Mediana Edad , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Radiólogos
3.
Radiology ; 302(2): 368-377, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34751615

RESUMEN

Background Tissue estimates obtained by using microstructure imaging techniques, such as hybrid multidimensional (HM) MRI, may improve prostate cancer diagnosis but require histologic validation. Purpose To validate prostate tissue composition measured by using HM MRI, with quantitative histologic evaluation from whole-mount prostatectomy as the reference standard. Materials and Methods In this HIPAA-compliant study, from December 2016 to July 2018, prospective participants with biopsy-confirmed prostate cancer underwent 3-T MRI before radical prostatectomy. Axial HM MRI was performed with all combinations of echo times (57, 70, 150, and 200 msec) and b values (0, 150, 750, and 1500 sec/mm2). Data were fitted by using a three-compartment signal model to generate volumes for each tissue component (stroma, epithelium, lumen). Quantitative histologic evaluation was performed to calculate volume fractions for each tissue component for regions of interest corresponding to MRI. Tissue composition measured by using HM MRI and quantitative histologic evaluation were compared (paired t test) and correlated (Pearson correlation coefficient), and agreement (concordance correlation) was assessed. Receiver operating characteristic curve analysis for cancer diagnosis was performed. Results Twenty-five participants (mean age, 60 years ± 7 [standard deviation]; 30 cancers and 45 benign regions of interest) were included. Prostate tissue composition measured with HM MRI and quantitative histologic evaluation did not differ (stroma, 45% ± 11 vs 44% ± 11 [P = .23]; epithelium, 31% ± 15 vs 34% ± 15 [P = .08]; and lumen, 24% ± 13 vs 22% ± 11 [P = .80]). Between HM MRI and histologic evaluation, there was excellent correlation (Pearson r: overall, 0.91; stroma, 0.82; epithelium, 0.93; lumen, 0.90 [all P < .05]) and agreement (concordance correlation coefficient: overall, 0.91; stroma, 0.81; epithelium, 0.90; and lumen, 0.87). High areas under the receiver operating characteristic curve obtained with HM MRI (0.96 for epithelium and 0.94 for lumen, P < .001) and histologic evaluation (0.94 for epithelium and 0.88 for lumen, P < .001) were found for differentiation between benign tissue and prostate cancer. Conclusion Tissue composition measured by using hybrid multidimensional MRI had excellent correlation with quantitative histologic evaluation as the reference standard. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Muglia in this issue.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Diagnóstico Diferencial , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Próstata/diagnóstico por imagen , Próstata/patología , Prostatectomía , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía
4.
Magn Reson Med ; 88(5): 2298-2310, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35861268

RESUMEN

PURPOSE: To evaluate and quantify inter-directional and inter-acquisition variation in diffusion-weighted imaging (DWI) and emphasize signals that report restricted diffusion to enhance cancer conspicuity, while reducing the effects of local microscopic motion and magnetic field fluctuations. METHODS: Ten patients with biopsy-proven prostate cancer were studied under an Institutional Review Board-approved protocol. Individual acquisitions of DWI signal intensities were reconstructed to calculate inter-acquisition distributions and their statistics, which were compared for healthy versus cancer tissue. A method was proposed to detect and filter the acquisitions affected by motion-induced signal loss. First, signals that reflect restricted diffusion were separated from the acquisitions that suffer from signal loss, likely due to microscopic motion, by imposing a cutoff value. Furthermore, corrected apparent diffusion coefficient maps were calculated by employing a weighted sum of the multiple acquisitions, instead of conventional averaging. These weights were calculated by applying a soft-max function to the set of acquisitions per-voxel, making the analysis immune to acquisitions with significant signal loss, even if the number of such acquisitions is high. RESULTS: Inter-acquisition variation is much larger than the Rician noise variance, local spatial variations, and the estimates of diffusion anisotropy based on the current data, as well as the published values of anisotropy. The proposed method increases the contrast for cancers and yields a sensitivity of 98 . 8 % $$ 98.8\% $$ with a false positive rate of 3 . 9 % $$ 3.9\% $$ . CONCLUSION: Motion-induced signal loss makes conventional signal-averaging suboptimal and can obscure signals from areas with restricted diffusion. Filtering or weighting individual acquisitions prior to image analysis can overcome this problem.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de la Próstata , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Movimiento (Física) , Próstata , Neoplasias de la Próstata/diagnóstico por imagen
5.
BMC Med Imaging ; 22(1): 171, 2022 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-36175878

RESUMEN

BACKGROUND: Thresholding apparent diffusion coefficient (ADC) maps obtained from Diffusion-Weighted-Imaging (DWI) has been proposed for identifying benign lesions that can safely avoid biopsy. The presence of malignancies with high ADC values leads to high thresholds, limiting numbers of avoidable biopsies. PURPOSE: We evaluate two previously reported methods for identifying avoidable biopsies: using case-set dependent ADC thresholds that assure 100% sensitivity and using negative likelihood ratio (LR-) with a fixed ADC threshold of 1.50 × 10-3 mm2/s. We evaluated improvements in efficacy obtained by excluding non-mass lesions and lesions with anisotropic intra-lesion morphologic characteristics. STUDY TYPE: Prospective. POPULATION: 55 adult females with dense breasts with 69 BI-RADS 4 or 5 lesions (38 malignant, 31 benign) identified on ultrasound and mammography and imaged with MRI prior to biopsy. FIELD STRENGTH/SEQUENCE: 1.5 T and 3.0 T. DWI. ASSESSMENT: Analysis of DWI, including directional images was done on an ROI basis. ROIs were drawn on DWI images acquired prior to biopsy, referencing all available images including DCE, and mean ADC was measured. Anisotropy was quantified via variation in ADC values in the lesion core across directional DWI images. STATISTICAL TESTS: Improvement in specificity at 100% sensitivity was evaluated with exact McNemar test with 1-sided p-value < 0.05 indicating statistical significance. RESULTS: Using ADC thresholding that assures 100% sensitivity, non-mass and directional variance filtering improved the percent of avoidable biopsies to 42% from baseline of 10% achieved with ADC thresholding alone. Using LR-, filtering improved outcome to 0.06 from baseline 0.25 with ADC thresholding alone. ADC thresholding showed a lower percentage of avoidable biopsies in our cohort than reported in prior studies. When ADC thresholding was supplemented with filtering, the percentage of avoidable biopsies exceeded those of prior studies. DATA CONCLUSION: Supplementing ADC thresholding with filters excluding non-mass lesions and lesions with anisotropic characteristics on DWI can result in an increased number of avoidable biopsies.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Adulto , Biopsia , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Estudios Prospectivos , Sensibilidad y Especificidad
6.
Magn Reson Med ; 85(2): 667-677, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32783262

RESUMEN

PURPOSE: Dysmyelinating diseases are characterized by abnormal myelin formation and function. Such microstructural abnormalities in myelin have been demonstrated to produce measurable effects on the MR signal. This work examines these effects on measurements of voxel-wise, high-resolution water spectra acquired using a 3D echo-planar spectroscopic imaging (EPSI) pulse sequence from both postmortem fixed control mouse brains and a dysmyelination mouse brain model. METHODS: Perfusion fixed, resected control (n = 5) and shiverer (n = 4) mouse brains were imaged using 3D-EPSI with 100 µm isotropic resolution. The free induction decay (FID) was sampled every 2.74 ms over 192 echoes, for a total sampling duration of 526.08 ms. Voxel-wise FIDs were Fourier transformed to produce water spectra with 1.9 Hz resolution. Spectral asymmetry was computed and compared between the two tissue types. RESULTS: The water resonance is more asymmetrically broadened in the white matter of control mouse brain compared with dysmyelinated white matter. In control brain, this is modulated by and consistent with previously reported orientationally dependent effects of white matter relative to B0 . Similar sensitivity to orientation is observed in dysmyelinated white matter as well; however, the magnitude of the resonance asymmetry is much lower across all directions. CONCLUSION: Results demonstrate that components of the spectra are specifically differentially affected by myelin concentration. This suggests that water proton spectra may be sensitive to the presence of myelin, and as such, could serve as a MRI-based biomarker of dysmyelinating disease, free of mathematical models.


Asunto(s)
Vaina de Mielina , Sustancia Blanca , Animales , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar , Imagen por Resonancia Magnética , Ratones , Agua , Sustancia Blanca/diagnóstico por imagen
7.
Magn Reson Med ; 86(3): 1505-1513, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33963782

RESUMEN

PURPOSE: High spectral and spatial resolution (HiSS) MRI is a spectroscopic imaging method focusing on water and fat resonances that has good diagnostic utility in breast imaging. The purpose of this work was to assess the feasibility and potential utility of HiSS MRI for the diagnosis of prostate cancer. METHODS: HiSS MRI was acquired at 3 T from six patients who underwent prostatectomy, yielding a train of 127 phase-coherent gradient echo (GRE) images. In the temporal domain, changes in voxel intensity were analyzed and linear (R) and quadratic (R1, R2) quantifiers of signal logarithm decay were calculated. In the spectral domain, three signal scaling-independent parameters were calculated: water resonance peak width (PW), relative peak asymmetry (PRA), and relative peak distortion from ideal Lorentzian shape (PRD). Seven cancer and five normal tissue regions of interest were identified in correlation with pathology and compared. RESULTS: HiSS-derived quantifiers, except R2, showed high reproducibility (coefficients of variation, 5%-14%). Spectral domain quantifiers performed better than temporal domain quantifiers, with receiver operator characteristic areas under the curve ranging from of 0.83 to 0.91. For temporal domain parameters, the range was 0.74 to 0.91. Low absolute values of the coefficients of correlation between monoexponential decay markers (R, PW) and resonance shape markers (PRA, PRD) were observed (range, 0.23-0.38). CONCLUSION: The feasibility and potential diagnostic utility of HiSS MRI in the prostate at 3 T without an endorectal coil was confirmed. Weak correlation between well-performing markers indicates that complementary information could be leveraged to further improve diagnostic accuracy.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Humanos , Masculino , Proyectos Piloto , Neoplasias de la Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
8.
Eur Radiol ; 31(1): 325-332, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32785769

RESUMEN

OBJECTIVES: To evaluate utility of T2*-weighted (T2*W) MRI as a tool for intra-operative identification of ablation zone extent during focal laser ablation (FLA) of prostate cancer (PCa), as compared to the current standard of contrast-enhanced T1-weighted (T1W) MRI. METHODS: Fourteen patients with biopsy-confirmed low- to intermediate-risk localized PCa received MRI-guided (1.5 T) FLA thermotherapy. Following FLA, axial multiple-TE T2*W images, diffusion-weighted images (DWI), and T2-weighted (T2W) images were acquired. Pre- and post-contrast T1W images were also acquired to assess ablation zone (n = 14) extent, as reference standard. Apparent diffusion coefficient (ADC) maps and subtracted contrast-enhanced T1W (sceT1W) images were calculated. Ablation zone regions of interest (ROIs) were outlined manually on all ablated slices. The contrast-to-noise ratio (CBR) of the ablation site ROI relative to the untreated contralateral prostate tissue was calculated on T2*W images and ADC maps and compared to that in sceT1W images. RESULTS: CBRs in ablation ROIs on T2*W images (TE = 32, 63 ms) did not differ (p = 0.33, 0.25) from those in sceT1W images. Bland-Altman plots of ROI size and CBR in ablation sites showed good agreement between T2*W (TE = 32, 63 ms) and sceT1W images, with ROI sizes on T2*W (TE = 63 ms) strongly correlated (r = 0.64, p = 0.013) and within 15% of those in sceT1W images. CONCLUSIONS: In detected ablation zone ROI size and CBR, non-contrast-enhanced T2*W MRI is comparable to contrast-enhanced T1W MRI, presenting as a potential method for intra-procedural monitoring of FLA for PCa. KEY POINTS: • T2*-weighted MR images with long TE visualize post-procedure focal laser ablation zone comparably to the contrast-enhanced T1-weighted MRI. • T2*-weighted MRI could be used as a plausible method for repeated intra-operative monitoring of thermal ablation zone in prostate cancer, avoiding potential toxicity due to heating of contrast agent.


Asunto(s)
Hipertermia Inducida , Terapia por Láser , Neoplasias de la Próstata , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía
9.
NMR Biomed ; 33(10): e4363, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32881124

RESUMEN

Breast cancer is the second most commonly diagnosed malignancy among women globally. Past MRI studies have linked a high animal fat diet (HAFD) to increased mammary cancer risk in the SV40Tag mouse model of triple-negative breast cancer. Here, serial MRI examines tumor progression and measures the arterial blood volume feeding mammary glands in low fat diet (LFD) or HAFD fed mice. Virgin female C3(1)SV40Tag mice (n = 8), weaned at 3 weeks old, were assigned to an LFD (n = 4, 3.7 kcal/g, 17.2% kcal from vegetable oil) or an HAFD (n = 4, 5.3 kcal/g, 60% kcal from lard) group. From ages 8 to 12 weeks, weekly fast spin echo MR images and time-of-flight (TOF) MR angiography of inguinal mammary glands were acquired at 9.4 T. Following in vivo MRI, mice were sacrificed. Inguinal mammary glands were excised and fixed for ex vivo MRI and histology. Tumor, blood, and mammary gland volumes for each time point were measured from manually traced regions of interest; tumors were classified as invasive by histopathology-blinded observers. Our analysis confirmed a strong correlation between total tumor volume and blood volume in the mammary gland. Tumor growth rates from weeks 8-12 were twice as high in HAFD-fed mice (0.42 ± 0.14/week) as in LFD-fed mice (0.21 ± 0.03/week), p < 0.004. Mammary gland blood volume growth rate was 2.2 times higher in HAFD mice (0.29 ± 0.11/week) compared with LFD mice (0.13 ± 0.06/week), p < 0.02. The mammary gland growth rate of HAFD-fed mice (0.071 ± 0.011/week) was 2.7 times larger than that of LFD-fed mice (0.026 ± 0.009/week), p < 0.01. This is the first non-invasive, in vivo MRI study to demonstrate a strong correlation between an HAFD and increased cancer burden and blood volume in mammary cancer without using contrast agents, strengthening the evidence supporting the adverse effects of an HAFD on mammary cancer. These results support the potential future use of TOF angiography to evaluate vasculature of suspicious lesions.


Asunto(s)
Arterias/diagnóstico por imagen , Carcinogénesis/patología , Dieta Alta en Grasa , Conducta Alimentaria , Angiografía por Resonancia Magnética , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Neoplasias de la Mama Triple Negativas/patología , Animales , Modelos Animales de Enfermedad , Femenino , Imagenología Tridimensional , Glándulas Mamarias Animales/diagnóstico por imagen , Glándulas Mamarias Animales/patología , Neoplasias Mamarias Animales/diagnóstico por imagen , Neoplasias Mamarias Animales/patología , Ratones , Invasividad Neoplásica , Tamaño de los Órganos , Flujo Sanguíneo Regional , Carga Tumoral
10.
BMC Med Imaging ; 20(1): 61, 2020 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-32517657

RESUMEN

BACKGROUND: There is an increasing interest in non-contrast-enhanced magnetic resonance imaging (MRI) for detecting and evaluating breast lesions. We present a methodology utilizing lesion core and periphery region of interest (ROI) features derived from directional diffusion-weighted imaging (DWI) data to evaluate performance in discriminating benign from malignant lesions in dense breasts. METHODS: We accrued 55 dense-breast cases with 69 lesions (31 benign; 38 cancer) at a single institution in a prospective study; cases with ROIs exceeding 7.50 cm2 were excluded, resulting in analysis of 50 cases with 63 lesions (29 benign, 34 cancers). Spin-echo echo-planar imaging DWI was acquired at 1.5 T and 3 T. Data from three diffusion encoding gradient directions were exported and processed independently. Lesion ROIs were hand-drawn on DWI images by two radiologists. A region growing algorithm generated 3D lesion models on augmented apparent-diffusion coefficient (ADC) maps and defined lesion core and lesion periphery sub-ROIs. A lesion-core and a lesion-periphery feature were defined and combined into an overall classifier whose performance was compared to that of mean ADC using receiver operating characteristic (ROC) analysis. Inter-observer variability in ROI definition was measured using Dice Similarity Coefficient (DSC). RESULTS: The region-growing algorithm for 3D lesion model generation improved inter-observer variability over hand drawn ROIs (DSC: 0.66 vs 0.56 (p < 0.001) with substantial agreement (DSC > 0.8) in 46% vs 13% of cases, respectively (p < 0.001)). The overall classifier improved discrimination over mean ADC, (ROC- area under the curve (AUC): 0.85 vs 0.75 and 0.83 vs 0.74 respectively for the two readers). CONCLUSIONS: A classifier generated from directional DWI information using lesion core and lesion periphery information separately can improve lesion discrimination in dense breasts over mean ADC and should be considered for inclusion in computer-aided diagnosis algorithms. Our model-based ROIs could facilitate standardization of breast MRI computer-aided diagnostics (CADx).


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Mama/patología , Densidad de la Mama , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Variaciones Dependientes del Observador , Sensibilidad y Especificidad
11.
Magn Reson Med ; 81(1): 79-89, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30014543

RESUMEN

PURPOSE: This work was performed to investigate the effects of tissue microstructure from postmortem rat brain on the shape of the water proton spectrum. METHODS: Perfusion-fixed, resected rat brains (N = 4) were imaged at 9.4T. 3D DTI and 3D echo-planar spectroscopic imaging (EPSI) data were acquired with 150 µm isotropic resolution. DTI data were acquired over 60 directions with b = 3000 s/mm2 . Water spectra were produced from EPSI data acquired over 128 echoes, with 2.9 Hz spectral resolution. A voxel-wise metric reflecting spectral asymmetry about the peak of the resonance was computed and compared with orientation estimates from DTI data by fitting data with the susceptibility anisotropy model. RESULTS: Asymmetric broadening of the water resonance was computed for mixed populations of grey and/or white matter as determined by thresholding the fractional anisotropy. Asymmetry was shown to be differentially affected by tract orientation relative to B0 in high FA voxels, whereas low FA voxels exhibited little sensitivity. Anatomic structures in the hippocampus were also found to produce distinct changes in the water resonance. CONCLUSION: Present results demonstrate that structural variations in tissue architecture cause characteristic, reproducible changes in the water resonance shape. This suggests that water spectra are sensitive to cytoarchitectural variations in brain tissue.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen Eco-Planar , Espectroscopía de Resonancia Magnética , Animales , Anisotropía , Encéfalo/patología , Sustancia Gris/diagnóstico por imagen , Hipocampo/diagnóstico por imagen , Imagenología Tridimensional , Protones , Ratas , Espectrofotometría , Agua/química , Sustancia Blanca/diagnóstico por imagen
12.
Magn Reson Med ; 81(3): 2147-2160, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30368906

RESUMEN

PURPOSE: We propose a novel methodology to integrate morphological and functional information of tumor-associated vessels to assist in the diagnosis of suspicious breast lesions. THEORY AND METHODS: Ultrafast, fast, and high spatial resolution DCE-MRI data were acquired on 15 patients with suspicious breast lesions. Segmentation of the vasculature from the surrounding tissue was performed by applying a Hessian filter to the enhanced image to generate a map of the probability for each voxel to belong to a vessel. Summary measures were generated for vascular morphology, as well as the inputs and outputs of vessels physically connected to the tumor. The ultrafast DCE-MRI data was analyzed by a modified Tofts model to estimate the bolus arrival time, Ktrans (volume transfer coefficient), and vp (plasma volume fraction). The measures were compared between malignant and benign lesions via the Wilcoxon test, and then incorporated into a logistic ridge regression model to assess their combined diagnostic ability. RESULTS: A total of 24 lesions were included in the study (13 malignant and 11 benign). The vessel count, Ktrans , and vp showed significant difference between malignant and benign lesions (P = 0.009, 0.034, and 0.010, area under curve [AUC] = 0.76, 0.63, and 0.70, respectively). The best multivariate logistic regression model for differentiation included the vessel count and bolus arrival time (AUC = 0.91). CONCLUSION: This study provides preliminary evidence that combining quantitative characterization of morphological and functional features of breast vasculature may provide an accurate means to diagnose breast cancer.


Asunto(s)
Neoplasias de la Mama/irrigación sanguínea , Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Anciano , Área Bajo la Curva , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Modelos Logísticos , Microcirculación , Persona de Mediana Edad , Análisis Multivariante , Curva ROC , Análisis de Regresión , Factores de Tiempo
13.
AJR Am J Roentgenol ; 212(2): 351-356, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30540213

RESUMEN

OBJECTIVE: The objective of our study was to investigate the comparative effectiveness of different MRI sequences for the estimation of index lesion volume in patients with prostate cancer (PCa) compared with ground truth volume measured on whole-mount pathology. MATERIALS AND METHODS: Patients with PCa underwent multiparametric MRI (mpMRI) on a 3-T MRI scanner before radical prostatectomy. Forty PCa index lesions were identified and outlined on histology by a pathologist. Two radiologists who were informed about the presence of PCa but were not aware of lesion outlines on histology worked in consensus to delineate PCa lesions on T2-weighted imaging, apparent diffusion coefficient (ADC) maps, and early-phase dynamic contrast-enhanced MRI (DCE-MRI). The lesion volumes from different mpMRI sequences and the percentage of volume underestimation compared with pathology were calculated and correlated with volume at pathology. The repeated-measures ANOVA with the posthoc Bonferroni test was performed to evaluate whether the difference between the estimated tumor volumes was statistically significant. RESULTS: The mean PCa lesion volume estimated from pathology, T2-weighted imaging, DWI (ADC maps), and DCE-MRI were 4.61 ± 4.99 (SD) cm3, 2.03 ± 2.96 cm3, 1.81 ± 2.76 cm3, and 3.48 ± 4.06 cm3, respectively. The lesion volumes on T2-weighted images (p = 0.000002), ADC maps (p = 0.000003), and DCE-MR images (p = 0.004412) were significantly lower than those from pathology. PCa lesion volume was significantly underestimated on T2-weighted images, ADC maps, and DCE-MR images compared with pathology by 54.98% ± 22.60% (mean ± SD), 58.59% ± 18.58%, and 18.33% ± 30.11%, respectively; underestimation using T2-weighted imaging (p = 1.01 × 10-11) and DWI (p = 2.94 × 10-11) was significantly higher than underestimation using DCE-MRI. Correlations between lesion volume estimated on T2-weighted images, ADC maps, and DCE-MR images with pathology were 0.91 (p = 9.03 × 10-16), 0.86 (p = 7.32 × 10-13), and 0.93 (p = 8.22 × 10-18), respectively. CONCLUSION: DCE-MRI performed better than T2-weighted imaging and DWI for estimation of index PCa volume and therefore can be preferred over these other two sequences for volume estimation.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Correlación de Datos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Carga Tumoral
14.
AJR Am J Roentgenol ; 213(2): W66-W75, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31039019

RESUMEN

OBJECTIVE. The purpose of this study was to develop a new quantitative image analysis tool for estimating the risk of cancer of the prostate by use of quantitative multiparametric MRI (mpMRI) metrics. MATERIALS AND METHODS. Thirty patients with biopsy-confirmed prostate cancer (PCa) who underwent preoperative 3-T mpMRI were included in the study. Quantitative mpMRI metrics-apparent diffusion coefficient (ADC), T2, and dynamic contrast-enhanced (DCE) signal enhancement rate (α)-were calculated on a voxel-by-voxel basis for the whole prostate and coregistered. A normalized risk value (0-100) for each mpMRI parameter was obtained, with high risk values associated with low T2 and ADC and high signal enhancement rate. The final risk score was calculated as a weighted sum of the risk scores (ADC, 40%; T2, 40%; DCE, 20%). Data from five patients were used as training set to find the threshold for predicting PCa. In the other 25 patients, any region with a minimum of 30 con-joint voxels (≈ 4.8 mm2) with final risk score above the threshold was considered positive for cancer. Lesion-based and sector-based analyses were performed by matching prostatectomyverified malignancy and PCa predicted with the risk analysis tool. RESULTS. The risk map tool had sensitivity of 76.6%, 89.2%, and 100% for detecting all lesions, clinically significant lesions (≥ Gleason 3 + 4), and index lesions, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value for PCa detection for all lesions in the sector-based analysis were 78.9%, 88.5%, 84.4%, and 84.1%, respectively, with an ROC AUC of 0.84. CONCLUSION. The risk analysis tool is effective for detecting clinically significant PCa with reasonable sensitivity and specificity in both peripheral and transition zones.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Biopsia , Medios de Contraste , Imagen de Difusión por Resonancia Magnética , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Prostatectomía , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Estudios Retrospectivos , Medición de Riesgo , Sensibilidad y Especificidad
15.
AJR Am J Roentgenol ; 212(1): 124-129, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30403532

RESUMEN

OBJECTIVE: This study investigates the multiparametric MRI (mpMRI) characteristics and pathologic outcome of wedge-shaped lesions observed on T2-weighted images. MATERIALS AND METHODS: Seventy-six patients with histologically confirmed prostate cancer underwent preoperative 3-T MRI before undergoing radical prostatectomy. Two radiologists worked in consensus to mark wedge-shaped regions of hypointensity on T2-weighted images and assess their appearance on apparent diffusion coefficient (ADC) maps (to determine the degree of hypointensity) and dynamic contrast-enhanced (DCE) MRI (DCE-MRI) (to assess whether they showed early enhancement). The pathologic outcome of wedge-shaped lesions was assessed by matching MR images with whole-mount histologic specimens retrospectively. The difference in quantitative ADC values between malignant and benign wedge-shaped lesions was assessed using a t test. RESULTS: Thirty-five wedge-shaped regions were identified, 12 (34%) of which were found be malignant. Most malignant wedge-shaped regions were highly hypointense (10/12; 83%) on ADC maps and showed early enhancement on DCE-MRI (7/12; 58%). However, benign wedge-shaped lesions were predominantly mildly hypointense (13/23; 57%) on ADC maps and showed no early enhancement (15/23; 65%). Histologic correlates of the benign wedge-shaped regions showed prostatitis (acute inflammation [7/23; 30%] or chronic inflammation [9/23; 39%]), hemosiderin-laden macrophages (6/23; 26%), prominent blood vessels (7/23; 30%), intraluminal blood (6/23; 26%), and nonspecific atrophy (6/23; 26%). The mean (± SD) quantitative ADC value of malignant wedge-shaped regions (1.13 ± 0.11 µm2/ms) was significantly lower (p = 0.0001) than that of benign wedge-shaped regions (1.52 ± 0.27 µm2/ms). CONCLUSION: This study shows that a greater percentage of wedge-shaped features are malignant than was previously thought. Of importance, mpMRI (specifically, ADC maps) can distinguish between malignant and benign wedge-shaped features.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Adulto , Anciano , Medios de Contraste , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Prostatectomía , Neoplasias de la Próstata/cirugía , Estudios Retrospectivos
16.
Radiology ; 287(3): 864-873, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29393821

RESUMEN

Purpose To evaluate whether compartmental analysis by using hybrid multidimensional magnetic resonance (MR) imaging can be used to diagnose prostate cancer and determine its aggressiveness. Materials and Methods Twenty-two patients with prostate cancer underwent preoperative 3.0-T MR imaging. Axial images were obtained with hybrid multidimensional MR imaging by using all combinations of echo times (47, 75, 100 msec) and b values of 0, 750, 1500 sec/mm2, resulting in a 3 × 3 array of data associated with each voxel. Volumes of the tissue components stroma, epithelium, and lumen were calculated by fitting the hybrid data to a three-compartment signal model, with distinct, paired apparent diffusion coefficient (ADC) and T2 values associated with each compartment. Volume fractions and conventional ADC and T2 were measured for regions of interest in sites of prostatectomy-verified malignancy (n = 28) and normal tissue (n = 71). Receiver operating characteristic (ROC) analysis was used to evaluate the performance of various parameters in differentiating prostate cancer from benign tissue. Results Compared with normal tissue, prostate cancer showed significantly increased fractional volumes of epithelium (23.2% ± 7.1 vs 48.8% ± 9.2, respectively) and reduced fractional volumes of lumen (26.4% ± 14.1 vs 14.0% ± 5.2) and stroma (50.5% ± 15.7 vs 37.2% ± 9.1) by using hybrid multidimensional MR imaging. The fractional volumes of tissue components show a significantly higher Spearman correlation coefficient with Gleason score (epithelium: ρ = 0.652, P = .0001; stroma: ρ = -0.439, P = .020; lumen: ρ = -0.390, P = .040) compared with traditional T2 values (ρ = -0.292, P = .132) and ADCs (ρ = -0.315, P = .102). The area under the ROC curve for differentiation of cancer from normal prostate was highest for fractional volume of epithelium (0.991), followed by fractional volumes of lumen (0.800) and stroma (0.789). Conclusion Fractional volumes of prostatic lumen, stroma, and epithelium change significantly when cancer is present. These parameters can be measured noninvasively by using hybrid multidimensional MR imaging and have the potential to improve the diagnosis of prostate cancer and determine its aggressiveness. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Adulto , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Estudios Prospectivos , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
17.
AJR Am J Roentgenol ; 211(4): 933-939, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30063374

RESUMEN

OBJECTIVE: The purpose of this study was to validate a kinetic assessment based on visually identified peak enhancement, which is routinely used in clinical practice, for differentiating benign from malignant lesions during fast dynamic contrast-enhanced MRI. MATERIALS AND METHODS: Between January 2015 and December 2016, 90 consecutively registered patients with 105 breast lesions (40 benign, 65 malignant) underwent dynamic contrast-enhanced 1.5-T MRI that included one unenhanced and eight contrast-enhanced fast temporal resolution (10 seconds) whole-breast acquisitions. Histogram analysis was performed to measure the voxel-based enhancement of the entire lesion to obtain 90th, 75th, and 50th percentile values at each time point and to generate kinetic curves. Two observers selected visually identified peak enhancement within the lesions to generate the kinetic curves. The kinetic curves from histogram and visually identified peak enhancement analyses were fitted by means of an empiric mathematic model (EMM): ΔS(t) = A × (1 - e-αt), where A is the upper limit of signal intensity, e indicates the exponential function, and α (min-1) is the rate of increase in signal intensity. The initial slope of the kinetic curve (A × α) and the initial AUC (AUC30) were calculated. These parameters were compared between benign and malignant lesions, and results from visually identified peak enhancement analysis were compared with those from histogram analysis. RESULTS: Benign lesions were successfully differentiated from malignant lesions in both visually identified peak enhancement and histogram analyses (90th and 75th percentile values) on the basis of α, A × α, and AUC30 from the EMM. There was no significant difference in ROC AUC in these EMM parameters between visually identified peak enhancement and histogram analyses (p = 0.21). CONCLUSION: Kinetic assessment with visually identified peak enhancement was acceptable for differentiating benign from malignant lesions.


Asunto(s)
Neoplasias de la Mama/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Biopsia , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
18.
NMR Biomed ; 30(10)2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28661075

RESUMEN

High animal fat consumption is associated with an increase in triple-negative breast cancer (TNBC) risk. Based on previous MRI studies demonstrating the feasibility of detecting very early non-palpable mammary cancers in simian virus 40 large T antigen (SV40TAg) mice, we examined the effect of dietary fat fed from weaning to young adulthood in this model of TNBC. Virgin female C3(1)SV40TAg mice (n = 16) were weaned at 3-4 weeks of age and then fed either a low fat diet (LFD) (n = 8, 3.7 kcal/g; 17.2% kcal from vegetable oil) or a high animal fat diet (HAFD) (n = 8, 5.3 kcal/g; 60% kcal from lard). After 8 weeks on the diet (12 weeks of age), fast spin echo MR images of inguinal mammary glands were acquired at 9.4 T. Following in vivo MRI, mice were sacrificed and inguinal mammary glands were excised and formalin fixed for ex vivo MRI. 3D volume-rendered MR images were then correlated with mammary gland histology to assess the glandular parenchyma and tumor burden. Using in vivo MRI, an average of 3.88 ± 1.03 tumors were detected per HAFD-fed mouse compared with an average of 1.25 ± 1.16 per LFD-fed mouse (p < 0.007). Additionally, the average tumor volume was significantly higher following HAFD feeding (0.53 ± 0.45 mm3 ) compared with LFD feeding (0.20 ± 0.08 mm3 , p < 0.02). Analysis of ex vivo MR and histology images demonstrated that HAFD mouse mammary glands had denser parenchyma, irregular and enlarged ducts, dilated blood vessels, increased white adipose tissue, and increased tumor invasion. MRI and histological studies of the SV40TAg mice demonstrated that HAFD feeding also resulted in higher cancer incidence and larger mammary tumors. Unlike other imaging methods for assessing environmental effects on mammary cancer growth, MRI allows routine serial measurements and reliable detection of small cancers as well as accurate tumor volume measurements and assessment of the three-dimensional distribution of tumors over time.


Asunto(s)
Carcinogénesis/patología , Grasas de la Dieta/efectos adversos , Imagen por Resonancia Magnética/métodos , Neoplasias Mamarias Animales/diagnóstico por imagen , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Adiposidad , Animales , Modelos Animales de Enfermedad , Femenino , Glándulas Mamarias Animales/diagnóstico por imagen , Glándulas Mamarias Animales/patología , Neoplasias Mamarias Animales/patología , Ratones , Neoplasias de la Mama Triple Negativas/patología , Carga Tumoral , Destete
19.
J Magn Reson Imaging ; 46(6): 1738-1747, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28295791

RESUMEN

PURPOSE: To evaluate the diagnostic value of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for patients with atypical ductal hyperplasia (ADH) in predicting malignant upgrade. MATERIALS AND METHODS: 3T DCE-MRI was performed for 17 patients with ADH (median age 52, range 42-76) proven by stereotactic biopsy (n = 15), and ultrasound-guided biopsy (n = 2) from January 2011 to April 2015. All patients underwent surgical excision after the MRI. Two radiologists prospectively reviewed the MRI to determine the presence or absence of suspicious findings at the site of biopsy, and evaluated the MR features of any lesion present according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon. MRI findings and clinical information were correlated with the final surgical pathology by multivariate analysis. RESULTS: Nine of 17 lesions were upgraded to malignancy. MRI demonstrated suspicious nonmass enhancement (NME) at the site of biopsy in all upgraded patients. The median size was 19.5 mm (range, 9-44 mm). In the eight patients without upgrade, no enhancement (n = 2), linear enhancement along the biopsy track (n = 4), thin rim enhancement around hematoma (n = 1), and a focal NME (n = 1) were seen. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI findings were 100, 87.5, 90, and 100%, respectively. Multivariate analysis revealed that the presence of suspicious enhancement on MRI was the most significant predictor of upgrade to malignancy (P = 0.0006) CONCLUSION: Our study revealed a high NPV of DCE-MRI for patients with ADH in terms of malignant upgrade at subsequent surgery. This suggests that patients with ADH without suspicious enhancement on DCE-MRI might be followed with DCE-MRI rather than undergoing surgical excision. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1738-1747.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/diagnóstico por imagen , Carcinoma Intraductal no Infiltrante/patología , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Adulto , Anciano , Biopsia , Mama , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
20.
J Magn Reson Imaging ; 46(5): 1341-1348, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28263425

RESUMEN

PURPOSE: To develop and assess a full-coverage, sensitivity encoding (SENSE)-accelerated breast high spatial and spectral resolution (HiSS) magnetic resonance imaging (MRI) within clinically reasonable times as a potential nonenhanced MRI protocol for breast density measurement or breast cancer screening. MATERIALS AND METHODS: Sixteen women with biopsy-proven cancer or suspicious lesions, and 13 women who were healthy volunteers or were screened for breast cancer, received 3T breast MRI exams, including SENSE-accelerated HiSS MRI, which was implemented as a submillimeter spatial resolution echo-planar spectroscopic imaging (EPSI) sequence. In postprocessing, fat and water resonance peak height and integral images were generated from EPSI data. The postprocessing software was custom-designed, and new algorithms were developed to enable processing of whole-coverage axial HiSS datasets. Water peak height HiSS images were compared to pre- and postcontrast T1 -weighted images. Fat suppression was quantified as parenchymal-to-suppressed-fat signal ratio in HiSS water peak height and nonenhanced T1 -weighted images, and artifact levels were scored. RESULTS: Approximately a 4-fold decrease in acquisition speed, with a concurrent 2.5-fold decrease in voxel size, was achieved, with low artifact levels, and with spectral signal-to-noise ratio (SNR) of 45:1. Fat suppression was 1.9 times more effective (P < 0.001) in HiSS images than in T1 -weighted images (SPAIR), and HiSS images showed higher SNR in the axilla. HiSS MRI visualized 10 of 13 malignant lesions identified on dynamic contrast-enhanced (DCE)-MRI, and did not require skin removal in postprocessing to generate maximum intensity projection images. CONCLUSION: We demonstrate full-coverage, SENSE-accelerated breast HiSS MRI within clinically reasonable times, as a potential protocol for breast density measurement or breast cancer screening. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1341-1348.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Adulto , Algoritmos , Biopsia , Densidad de la Mama , Medios de Contraste , Imagen Eco-Planar , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Relación Señal-Ruido , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA