Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 33(5): 953-961, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35175685

RESUMEN

BACKGROUND: Localization of atrioventricular accessory pathways (AP) from Electrocardiogram (ECG) is crucial for successful ablation. We analyzed the value of limb lead 2 versus 3 QRS vector discordance on surface ECG among right-sided pathways. METHODS: Data from consecutive patients undergoing successful ablation of manifest AP were analyzed. They were categorized into two groups-Gr I: Endocardial ablation from anterior and anterolateral tricuspid annulus (TA, 10-1 o'clock, right anterolateral [RAL]); Gr II: Ablation outside this region (1-10 o'clock of TA). Inferior lead discordance (ILD) was defined as positive QRS complex (monophasic R, Rs) in lead 2 with negative/equiphasic QRS vector in lead 3 (rS, S, RS). Maximally pre-excited ECGs during electrophysiology study were compared for presence of ILD. RESULT: Among total 22 cases (Age 36 ± 18 years, 12 males), ILD was noted in 4/4 cases of Gr I. It was absent among 17/18 cases of right-sided AP in Gr II. The only case in Gr II having ILD was ablated near 8 o'clock (posterolateral). In contrast to the other four cases, aVF was negative, along with lead 3. A close differential was mid-septal AP (MSAP). However, the MSAP had absence of r in V1 and lead 2 having rS/RS complex in contrast to strongly positive QRS in RAL pathways. The sensitivity and specificity of ILD for RAL are 100% and 95%, respectively. The positive, negative predictive value, and accuracy are 80%, 100%, and 95%, respectively. CONCLUSION: Positive QRS complex in lead 2 with negative QRS in lead 3 in maximally pre-excited ECG is often predictive of anterior and anterolateral location among right-sided pathways.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Síndromes de Preexcitación , Síndrome de Wolff-Parkinson-White , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/cirugía , Adolescente , Adulto , Fascículo Atrioventricular , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndromes de Preexcitación/cirugía , Adulto Joven
2.
Am J Otolaryngol ; 43(5): 103532, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35714497

RESUMEN

INTRODUCTION: Juvenile nasopharyngeal angiofibroma(JNA) are highly vascular benign tumours originating in the sphenopalatine fossa and may extend to the pterygopalatine fossa, paranasal sinuses, and nasal cavity. The management of JNA has evolved greatly with development of endoscopy. Treatment modality has changed from open approach to endoscopic approach due to various advantages offered by the endoscopic approach. Bleeding during the surgery can compromise the exposure and surgical excision of JNA endoscopically. There have been many techniques to decrease intraoperative bleeding including external carotid ligation, hypotensive anaesthesia and more recently embolization of the feeding vessels. Embolization of the tumour has made the endoscopic excision of JNA easier because of less bleeding. This study was taken to find out the outcomes of surgical excision of JNA after embolization. METHODOLOGY: We retrospectively reviewed 22 histopathological proven JNA cases that underwent preoperative embolization followed by resection during the period of June 2015 to December 2020 in our tertiary care hospital. From the records demographic, clinical, radiological imaging (CECT nose and PNS), angiographic, pre-operative embolization and operative details were evaluated. RESULT: In the present study a total of 22 cases of angiofibroma were taken up for surgical excision after embolization. A complete endonasal endoscopic resection could be done in 21/22 cases with average operative time of 141 minutes (80 minutes-190 minutes range). The mean blood loss during surgery was 1163 ml (Range 500 ml- 1900 ml). In 7/22 (31.81%) subjects required intraoperative blood transfusion. No perioperative surgical complications occurred. CONCLUSION: Endoscopic excision of JNA has now become the primary operative technique and pre operative embolization in such cases can reduce the intraoperative time, blood loss and tumour relapse rate. It is a relatively safe procedure in a hand of an expert and must be done where ever available.


Asunto(s)
Angiofibroma , Embolización Terapéutica , Neoplasias Nasofaríngeas , Angiofibroma/patología , Embolización Terapéutica/métodos , Endoscopía/métodos , Humanos , Neoplasias Nasofaríngeas/patología , Recurrencia Local de Neoplasia/patología , Estudios Retrospectivos
4.
Eur Heart J Case Rep ; 8(5): ytae215, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38756546

RESUMEN

Background: Acute fracture of a left main (LM) stent during angioplasty is a rare complication. Cardiologists should be aware of the risk of stent fracture (SF) following kissing balloon inflation (KBI) even if the effective diameter of the balloons does not exceed the recommended expansion limits of stents. Case summary: A 64-year-old female with hypertension and dyslipidaemia presented with crescendo angina since three months in spite of optimal medical therapy. Coronary angiogram showed a distal LM bifurcation lesion. The patient was admitted for LM bifurcation stenting by upfront two-stent technique (inverted double-kissing Culotte technique). Following first KBI of the stent placed from left circumflex artery (LCX) to LM, there was stent deformation in the LM shaft. As we had planned the Culotte technique, we decided to exclude the fractured segment by stenting from left anterior descending artery (LAD) to LM. The stent from LAD-LM successfully excluded the fractured part of the first stent from the lumen of LM. Optical coherence tomography done after final KBI from LCX-LM revealed successful exclusion of the deformed segment of the LCX stent with mild malapposition at the site of the deformed stent. A follow-up angiogram after six months showed normal in-stent flow with no evidence of restenosis or pseudoaneurysm. Discussion: Acute LM SF during coronary intervention can occur even if the effective cumulative diameter of the inflated balloons does not exceed the mentioned expansion limit of stents. Intravascular imaging is a helpful modality to define type of SF and its management.

5.
Indian Heart J ; 65(1): 91-4, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23438621

RESUMEN

Erosion of a peripancreatic artery into the pseudocyst as a result of enzymatic digestion of vessel wall gives rise to a pancreatic pseudoaneurysm (PSA), which is a rare complication seen in patients with chronic pancreatitis.(1) Angiographic embolization as a treatment method for acute hemorrhage from pancreatic PSA has become increasingly popular. Here we report a unique case with bleeding from a giant pancreatic PSA where the single PSA had blood supply originating from the branches of both the celiac artery and superior mesenteric artery.


Asunto(s)
Aneurisma Falso/terapia , Embolización Terapéutica/métodos , Enfermedades Pancreáticas/terapia , Adulto , Aneurisma Falso/diagnóstico por imagen , Angiografía , Diagnóstico Diferencial , Humanos , Masculino , Enfermedades Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X
6.
Indian Heart J ; 65(1): 100-3, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23438623

RESUMEN

The fibrous body between the mitral and aortic valve, known as mitral-aortic intervalvular fibrosa (MAIVF) is prone to infection and injury resulting in pseudo-aneurysm formation. Because of its relative rarity, we are far from making any conclusion regarding the natural history and appropriate therapeutic strategy for this condition. We report two cases of this condition with two different and rare etiologies with strikingly different natural courses, providing insight into the natural course and timing of surgery in this rare entity.


Asunto(s)
Aneurisma Falso/diagnóstico por imagen , Aneurisma Cardíaco/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Adulto , Diagnóstico Diferencial , Ecocardiografía , Resultado Fatal , Humanos , Masculino
7.
Indian Heart J ; 65(3): 323-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23809390

RESUMEN

Stent dislodgment during percutaneous coronary intervention is a rare complication. We report a case of successful retrieval of a deformed coronary stent through alternative transfemoral approach while performing transradial procedure when the stent could not be retrieved safely from transradial route.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Remoción de Dispositivos/métodos , Stents , Angioplastia Coronaria con Balón/instrumentación , Angiografía Coronaria , Estenosis Coronaria/terapia , Falla de Equipo , Humanos , Masculino , Persona de Mediana Edad
8.
J Innov Card Rhythm Manag ; 13(4): 4960-4963, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35474858

RESUMEN

A 55-year-old woman with a dual-chamber pacemaker presented with brief episodes of rapid palpitation. The device recorded several stored atrial high-rate and ventricular high-rate episodes. The atrial intervals showed an interesting railroad track pattern during a non-sustained episode of ventricular tachycardia. We discussed the differential diagnosis of railroad track patterns on the atrial channel. In our case, it was related to far-field R-wave oversensing.

9.
J Arrhythm ; 38(1): 166-170, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35222766

RESUMEN

Recurrent unexplained syncope in the background of bundle branch block (BBB) often requires a pacemaker. But the decision-making for pacemaker is difficult in case of single episode of syncope with intermittent bundle branch block. We encountered one such case with intermittent LBBB, where the results of invasive EP study were even normal, until intravenous isoproterenol unmasked the infra-Hisian disease during decremental atrial pacing.

10.
Indian Heart J ; 74(1): 63-65, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34958795

RESUMEN

We studied left atrial (LA) function in severe rheumatic mitral stenosis (MS) patients using two-dimensional speckle tracking echocardiography (STE). Eighty patients with isolated severe MS in sinus rhythm and 40 controls underwent comprehensive echocardiography including STE derived LA strain [reservoir strain (LASr), conduit strain (LAScd) and contractile strain (LASct)]. The mean MVA was 0.93 ± 0.21 cm2. The mean values of LASr (14.73 ± 8.59%), LAScd (-7.61 ± 4.47%) and LASct (-7.16 ± 5.15%) in patients were significantly lower (p < 0.001) vs. controls 44.11 ± 10.44%, -32.45 ± 7.63%, -11.85 ± 6.77% respectively and showed decreasing trend with increasing MS severity and higher NYHA class. In conclusion, LA dysfunction is prevalent in severe MS irrespective of NYHA functional class.


Asunto(s)
Hipertensión Pulmonar , Estenosis de la Válvula Mitral , Función del Atrio Izquierdo , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Estenosis de la Válvula Mitral/diagnóstico , Estenosis de la Válvula Mitral/diagnóstico por imagen
11.
Eur Heart J Case Rep ; 5(12): ytab491, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34909577

RESUMEN

BACKGROUND: Riata implantable cardioverter-defibrillator (ICD) leads are prone to a unique type of mechanical lead failure causing conductor externalization (CE) which may be complicated by a delayed-onset electrical lead failure (ELF). CASE SUMMARY: A 60-year-old male with symptomatic, severe ischaemic cardiomyopathy, and atrial fibrillation following a prior anterior wall myocardial infarction received a dual-chamber ICD with 7F-RiataST ventricular lead as a primary prevention strategy against sudden cardiac death in 2008. In 2017, a pulse generator replacement was performed for elective replacement indicator status. At that time, CE was noted in the ventricular lead but the electrical lead parameters were normal, hence lead replacement was decided against and the patient was closely followed up thereafter. Four years later, the patient presented with multiple ICD shocks within 48 h. Implantable cardioverter-defibrillator interrogation showed noise on the ventricular electrogram (EGM) channel that was detected as ventricular fibrillation (VF) episodes, triggering inappropriate ICD therapy (five ICD detected VF events within 24 h triggering three antitachycardia pacing therapies and one shock). Lead impedance and R-wave amplitude were within normal range in supine position but dramatically worsened in sitting posture. A new ventricular lead was implanted and the old lead abandoned. The patient has not experienced any device therapy in the follow-up period. DISCUSSION: An electrically inert CE of Riata ICD leads needs close follow-up because an ELF may occur even after several years. A careful analysis of EGMs including postural changes in lead parameters can aid in detection and better characterization of underlying electrical dysfunction following CE.

12.
J Bone Metab ; 28(2): 139-150, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34130366

RESUMEN

BACKGROUND: There are limited studies comparing the risk of osteoporosis and fractures between different direct oral anticoagulants (DOACs) and vitamin K antagonists (VKA) in non-valvular atrial fibrillation (AF). Using a network meta-analysis (NMA), we compared osteoporotic fractures among 5 different treatment arms, viz. dabigatran, rivaroxaban, apixaban, edoxaban, and VKA. METHODS: Ten studies, including 5 randomized control trials and 5 population-based studies, with a total of 321,844 patients (148,751 and 173,093 in the VKA and DOAC group, respectively) with a median follow-up of 2 years, were included. A Bayesian random-effects NMA model comparing fractures among the treatment arms was performed using MetInsight V3. Sensitivity analysis excluded studies with the highest residual deviances from the NMA model. RESULTS: The mean age of the patients was 70 years. The meta-analysis favored DOACs over VKA with significantly lower osteoporotic fracture (odds ratio [OR], 0.77; 95% credible interval [CrI], 0.70-0.86). The NMA demonstrated that fractures were significantly lower with apixaban compared with dabigatran (OR, 0.64; 95% CrI, 0.44-0.95); however, fractures were statistically similar between apixaban and rivaroxaban (OR, 0.84; 95% CrI, 0.58-1.24) and dabigatran and rivaroxaban (OR, 1.32; 95% CrI, 0.90-1.87). Based on the Bayesian model of NMA, the probability of osteoporotic fracture was highest with VKA and lowest with apixaban, followed by rivaroxaban, edoxaban, and dabigatran. CONCLUSIONS: The decision to prescribe anticoagulants in elderly patients with AF should be made not only based on thrombotic and bleeding risks but also on the risk of osteoporotic fracture; these factors should be considered and incorporated in contemporary cardiology practice.

13.
Int J Heart Fail ; 3(3): 179-193, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36262637

RESUMEN

Background and Objectives: Persistent atrial fibrillation (PeAF) with heart failure (HF) arguably constitutes the sickest subset of atrial fibrillation (AF) patients. Methods: A systematic search was made in PubMed, Embase, and Scopus databases. Network meta-analysis (NMA) of PeAF patients with systolic HF comparing all-cause mortality, change in HF-related quality of life (QoL) and hospitalization due to heart failure (HHF) were performed among catheter ablation (CA) of AF, rate-controlling drugs (RCDs), anti-arrhythmic drugs (AADs), and atrio-ventricular nodal ablation (AVNA) using Bayesian random effect model. Results: Ablation strategies resulted significantly lower mortality than medical therapies (odds ratio [OR], 0.51; 95% confidence interval [CI], 0.35 to 0.76). CA of AF was associated with lower trend of mortality (OR, 0.78; 95% credible interval [CrI], 0.08 to 7.63) in comparison to AVNA in the Bayesian NMA. Rhythm control strategies resulted significantly higher improvement of QoL than rate control strategies (mean difference [MD], -12.78; 95% CI, -21.26 to -4.31). Bayesian NMA showed that CA of AF was better than AAD (MD, -7.98; 95% CrI, -27.68 to 8.27), however ranked AVNA to be lowest. Ablation strategies provided significantly lower HHF than medical therapies (OR, 0.42; 95% CI, 0.30 to 0.58). Bayesian NMA showed that CA of AF performed not only better than AAD (OR, 0.33; 95% CrI, 0.09 to 1.3) to reduce HHF, but also than AVNA (OR, 0.20; 95% CrI, 0.00 to 4.76). Of note, RCD ranked lowest with regard to mortality and HHF. Conclusions: CA of AF remains the best strategy even for the sickest group of PeAF patients with systolic HF in regards to all-cause mortality, HF-related QoL and HHF.

14.
Indian Heart J ; 73(6): 674-681, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34673026

RESUMEN

OBJECTIVES: COVID-19 pandemic has led to unprecedented increase in rates of stress and burn out among healthcare workers (HCWs). Heart rate variability (HRV) has been shown to be reflective of stress and burnout. The present study evaluated the prevalence of burnout and attempted to develop a HRV based predictive machine learning (ML) model to detect burnout among HCWs during COVID-19 pandemic. METHODS: Mini-Z 1.0 survey was collected from 1615 HCWs, of whom 664, 512 and 439 were frontline, second-line and non-COVID HCWs respectively. Burnout was defined as score ≥3 on Mini-Z-burnout-item. A 12-lead digitized ECG recording was performed and ECG features of HRV were obtained using feature extraction. A ML model comprising demographic and HRV features was developed to detect burnout. RESULTS: Burnout rates were higher among second-line workers 20.5% than frontline 14.9% and non-COVID 13.2% workers. In multivariable analyses, features associated with higher likelihood of burnout were feeling stressed (OR = 6.02), feeling dissatisfied with current job (OR = 5.15), working in a chaotic, hectic environment (OR = 2.09) and feeling that COVID has significantly impacted the mental wellbeing (OR = 6.02). HCWs with burnout had a significantly lower HRV parameters like root mean square of successive RR intervals differences (RMSSD) [p < 0.0001] and standard deviation of the time interval between successive RR intervals (SDNN) [p < 0.001]) as compared to normal subjects. Extra tree classifier was the best performing ML model (sensitivity: 84%) CONCLUSION: In this study of HCWs from India, burnout prevalence was lower than reports from developed nations, and was higher among second-line versus frontline workers. Incorporation of HRV based ML model predicted burnout among HCWs with a good accuracy.


Asunto(s)
COVID-19 , Agotamiento Psicológico , Electrocardiografía , Personal de Salud , Humanos , India/epidemiología , Aprendizaje Automático , Pandemias , SARS-CoV-2
15.
Indian Heart J ; 73(1): 109-113, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33714394

RESUMEN

BACKGROUND: There is no large contemporary data from India to see the prevalence of burnout in HCWs in covid era. Burnout and mental stress is associated with electrocardiographic changes detectable by artificial intelligence (AI). OBJECTIVE: The present study aims to estimate the prevalence of burnout in HCWs in COVID-19 era using Mini Z-scale and to develop predictive AI model to detect burnout in HCWs in COVID-19 era. METHODS: This is an observational and cross-sectional study to evaluate the presence of burnout in HCWs in academic tertiary care centres of North India in the COVID-19 era. At least 900 participants will be enrolled in this study from four leading premier government-funded/public-private centres of North India. Each study centre will be asked to recruit HCWs by approaching them through various listed ways for participation in the study. Interested participants after initial screening and meeting the eligibility criteria, will be asked to fill the questionnaire (having demographic and work related with Mini Z questionnaire) to assess burnout. The healthcare workers will include physicians at all levels of training, nursing staff and paramedical staff who are involved directly or indirectly in COVID-19 care. The analysis of the raw electrocardiogram (ECG) data and development of algorithm using convolutional neural networks (CNN) will be done by experts. CONCLUSIONS: In Summary, we propose that ECG data generated from the people with burnout can be utilized to develop AI-enabled model to predict the presence of stress and burnout in HCWs in COVID-19 era.


Asunto(s)
Inteligencia Artificial , Agotamiento Profesional/epidemiología , COVID-19/psicología , Electrocardiografía , Personal de Salud , COVID-19/epidemiología , Estudios Transversales , Femenino , Humanos , India/epidemiología , Masculino , Prevalencia , Proyectos de Investigación , SARS-CoV-2
16.
Indian Heart J ; 72(6): 614-618, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33357656

RESUMEN

Seventy-five patients with isolated severe MS (mitral valve area: 1.10 ± 0.15 cm2) and pulmonary hypertension underwent regional and global longitudinal strain (GLS) measurements of left (LV) and right ventricle (RV) at baseline and within 48 h after percutaneous balloon mitral valvuloplasty (PBMV). PBMV resulted in significant improvement in LV GLS (-16.35 ± 1.67% vs -19.98 ± 2.17%) and RV GLS (-10.34 ± 2.38% vs -13.83 ± 2.04%), p < 0.001 for both. Absolute increase in strain of basal segments of LV was more compared to mid and apical segments. We also found significant positive correlation between decrease in mean LA pressure (pre PBMV 28.91 ± 4.21 mm Hg vs post PBMV 10.55 ± 3.04 mm Hg, difference of 16.36 mm Hg; p < 0.001) obtained invasively during PBMV for 62 patients with improvement in LV GLS (r = 0.257, p = 0.048), RV GLS (r = 0.267, p = 0.043), and fall in right ventricular systolic pressure (r = 0.308, p = 0.022) that occurred post PBMV. The LV dysfunction is predominantly because of altered hemodynamics due to restricted LV filling with additional contribution from rheumatic involvement of basal LV myocardial segments. The improvement in LV deformation after PBMV is likely due to increase in preload. RV afterload reduction because of LA pressure decrease improved RV deformation.


Asunto(s)
Valvuloplastia con Balón/métodos , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Estenosis de la Válvula Mitral/diagnóstico , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Adulto , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/fisiopatología , Masculino , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/cirugía , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
17.
Indian Heart J ; 60(4): 287-95, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19242004

RESUMEN

OBJECTIVE: The objective of our study was to evaluate the diagnostic accuracy of 64-slice computed tomography coronary angiography to detect haemodynamically significant stenosis (>50% luminal narrowing) in comparison to invasive coronary angiography and further analyze the result accounting for heart rate, coronary calcification and location of lesion in the coronary tree. METHODS AND RESULTS: Forty patients (39 male, 1 female; mean age 50.9 years) underwent both CT coronary angiography and invasive coronary angiography with in a gap of one day. All vessels were included in the study and no patient was excluded due to high heart rate. On per-segment based analysis with invasive coronary angiography as the gold standard, CT coronary angiography correctly identified 62 out of 78 significant stenoses with an overall sensitivity of 79.5% (62 of 78), specificity of 98.5% (532 of 540), positive predictive value of 88.6% (62 of 70) and negative predictive value of 97.1% (532 of 548). CONCLUSION: Our result suggests that 64-slice CT coronary angiography has high diagnostic accuracy to detect haemodynamically significant stenosis.


Asunto(s)
Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Factores de Tiempo
18.
Craniomaxillofac Trauma Reconstr ; 6(4): 271-4, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24436773

RESUMEN

Pseudoaneurysms are among very rare complications of maxillofacial trauma. When encountered, they have the potential to cause life-threatening hemorrhage. A wise surgeon should consider the possibility of underlying aneurysm even if the classic sign of pulsatile mass is not present. The role of interventional radiology is immaculate in the management of these aneurysms.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA