Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Insights Imaging ; 15(1): 202, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120752

RESUMEN

OBJECTIVES: To generate pseudo-CT (pCT) images of the pelvis from zero echo time (ZTE) MR sequences and compare them to conventional CT. METHODS: Ninety-one patients were prospectively scanned with CT and MRI including ZTE sequences of the pelvis. Eleven ZTE image volumes were excluded due to implants and severe B1 field inhomogeneity. Out of the 80 data sets, 60 were used to train and update a deep learning (DL) model for pCT image synthesis from ZTE sequences while the remaining 20 cases were selected as an evaluation cohort. CT and pCT images were assessed qualitatively and quantitatively by two readers. RESULTS: Mean pCT ratings of qualitative parameters were good to perfect (2-3 on a 4-point scale). Overall intermodality agreement between CT and pCT was good (ICC = 0.88 (95% CI: 0.85-0.90); p < 0.001) with excellent interreader agreements for pCT (ICC = 0.91 (95% CI: 0.88-0.93); p < 0.001). Most geometrical measurements did not show any significant difference between CT and pCT measurements (p > 0.05) with the exception of transverse pelvic diameter measurements and lateral center-edge angle measurements (p = 0.001 and p = 0.002, respectively). Image quality and tissue differentiation in CT and pCT were similar without significant differences between CT and pCT CNRs (all p > 0.05). CONCLUSIONS: Using a DL-based algorithm, it is possible to synthesize pCT images of the pelvis from ZTE sequences. The pCT images showed high bone depiction quality and accurate geometrical measurements compared to conventional CT. CRITICAL RELEVANCE STATEMENT: pCT images generated from MR sequences allow for high accuracy in evaluating bone without the need for radiation exposure. Radiological applications are broad and include assessment of inflammatory and degenerative bone disease or preoperative planning studies. KEY POINTS: pCT, based on DL-reconstructed ZTE MR images, may be comparable with true CT images. Overall, the intermodality agreement between CT and pCT was good with excellent interreader agreements for pCT. Geometrical measurements and tissue differentiation were similar in CT and pCT images.

2.
EJNMMI Phys ; 11(1): 10, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38282050

RESUMEN

BACKGROUND: Positron emission tomography-magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65 s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis. METHODS: Ten patients being treated with ano-rectal radiotherapy received a [Formula: see text]F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired t tests with a significance level corrected for multiple testing of [Formula: see text]. Equivalence margins of [Formula: see text] were used. RESULTS: Mean whole-image SUV differences were -0.02% (sCTAC) compared to -3.0% (MRAC), with larger differences in the bone regions (-0.5% to -16.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients [Formula: see text]. However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in [Formula: see text] were [Formula: see text] (± standard error, sCTAC) and [Formula: see text] (MRAC), and [Formula: see text] (sCTAC) and [Formula: see text] (MRAC) in [Formula: see text]. The sCTAC was statistically equivalent to CTAC within a [Formula: see text] equivalence margin for [Formula: see text] and [Formula: see text] ([Formula: see text] and [Formula: see text]), whereas the MRAC was not ([Formula: see text] and [Formula: see text]). CONCLUSION: Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40 s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner.

3.
Cancer Gene Ther ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085630

RESUMEN

Cetuximab induces responses in about 13% of head and neck squamous cell carcinomas (HNSCC). We describe the molecular mechanism of acquired resistance to cetuximab, which could be overcome by switching to a different anti-EGFR antibody. Biopsies were collected at three different time points: before the start of cetuximab (PRE-cetux), at acquired resistance to cetuximab (AR-cetux), and at acquired resistance to duligotuzumab (AR-duligo). Biopsies were analyzed using tumor and normal whole-exome sequencing, RNASeq, and targeted panel sequencing with ultra-deep coverage to generate differential mutation and expression profiles. WES and targeted sequencing analysis identified an EGFR p.G465R extracellular domain mutation in AR-cetux biopsy. Furthermore, RNASeq confirmed the expression of this mutation in the tumor tissue. This mutation prevented the binding of cetuximab to EGFR and was not present in PRE-cetux and AR-duligo biopsies, suggesting a potential mechanism of acquired resistance to cetuximab. Molecular dynamic simulations confirmed that duligotuzumab effectively binds EGFR with a p.G465R mutation. Interestingly, the p.G465R mutation improved the stability of the duligotuzumab-EGFR complex as compared to the wild-type EGFR. This is the first report of an EGFR ECD mutation associated with acquired resistance to cetuximab, posing a need for further validation. We suggest appropriate serial mutational profiling to identify ECD mutations should be considered for select patients with initial cetuximab benefit.

4.
IEEE Trans Radiat Plasma Med Sci ; 6(6): 678-689, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38223528

RESUMEN

A major remaining challenge for magnetic resonance-based attenuation correction methods (MRAC) is their susceptibility to sources of magnetic resonance imaging (MRI) artifacts (e.g., implants and motion) and uncertainties due to the limitations of MRI contrast (e.g., accurate bone delineation and density, and separation of air/bone). We propose using a Bayesian deep convolutional neural network that in addition to generating an initial pseudo-CT from MR data, it also produces uncertainty estimates of the pseudo-CT to quantify the limitations of the MR data. These outputs are combined with the maximum-likelihood estimation of activity and attenuation (MLAA) reconstruction that uses the PET emission data to improve the attenuation maps. With the proposed approach uncertainty estimation and pseudo-CT prior for robust MLAA (UpCT-MLAA), we demonstrate accurate estimation of PET uptake in pelvic lesions and show recovery of metal implants. In patients without implants, UpCT-MLAA had acceptable but slightly higher root-mean-squared-error (RMSE) than Zero-echotime and Dixon Deep pseudo-CT when compared to CTAC. In patients with metal implants, MLAA recovered the metal implant; however, anatomy outside the implant region was obscured by noise and crosstalk artifacts. Attenuation coefficients from the pseudo-CT from Dixon MRI were accurate in normal anatomy; however, the metal implant region was estimated to have attenuation coefficients of air. UpCT-MLAA estimated attenuation coefficients of metal implants alongside accurate anatomic depiction outside of implant regions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA