1.
J Appl Clin Med Phys ; 22(10): 8-21, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34558774

RESUMEN

PURPOSE: Bolus electron conformal therapy (BECT) is a clinically useful, well-documented, and available technology. The addition of intensity modulation (IM) to BECT reduces volumes of high dose and dose spread in the planning target volume (PTV). This paper demonstrates new techniques for a process that should be suitable for planning and delivering IM-BECT using passive radiotherapy intensity modulation for electrons (PRIME) devices. METHODS: The IM-BECT planning and delivery process is an addition to the BECT process that includes intensity modulator design, fabrication, and quality assurance. The intensity modulator (PRIME device) is a hexagonal matrix of small island blocks (tungsten pins of varying diameter) placed inside the patient beam-defining collimator (cutout). Its design process determines a desirable intensity-modulated electron beam during the planning process, then determines the island block configuration to deliver that intensity distribution (segmentation). The intensity modulator is fabricated and quality assurance performed at the factory (.decimal, LLC, Sanford, FL). Clinical quality assurance consists of measuring a fluence distribution in a plane perpendicular to the beam in a water or water-equivalent phantom. This IM-BECT process is described and demonstrated for two sites, postmastectomy chest wall and temple. Dose plans, intensity distributions, fabricated intensity modulators, and quality assurance results are presented. RESULTS: IM-BECT plans showed improved D90-10 over BECT plans, 6.4% versus 7.3% and 8.4% versus 11.0% for the postmastectomy chest wall and temple, respectively. Their intensity modulators utilized 61 (single diameter) and 246 (five diameters) tungsten pins, respectively. Dose comparisons for clinical quality assurance showed that for doses greater than 10%, measured agreed with calculated dose within 3% or 0.3 cm distance-to-agreement (DTA) for 99.9% and 100% of points, respectively. CONCLUSION: These results demonstrated the feasibility of translating IM-BECT to the clinic using the techniques presented for treatment planning, intensity modulator design and fabrication, and quality assurance processes.


Asunto(s)
Neoplasias de la Mama , Radioterapia Conformacional , Electrones , Femenino , Humanos , Mastectomía , Fantasmas de Imagen
2.
J Appl Clin Med Phys ; 22(1): 59-67, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33300664

RESUMEN

PURPOSE: The annual quality assurance (QA) of Leksell Gamma Knife® (LGK) systems are typically performed using films. Film is a good candidate for small field dosimetry due to its high spatial resolution and availability. However, there are multiple challenges with using film; film does not provide real-time measurement and requires batch-specific calibration. Our findings show that active detector-based QA can simplify the procedure and save time without loss of accuracy. METHODS: Annual QA tests for a LGK Icon™ system were performed using both film-based and filmless techniques. Output calibration, relative output factors (ROF), radiation profiles, sector uniformity/source counting, and verification of the unit center point (UCP) and radiation focal point (RFP) coincidence tests were performed. Radiochromic films, two ionization chambers, and a synthetic diamond detector were used for the measurements. Results were compared and verified with the treatment planning system (TPS). RESULTS: The measured dose rate of the LGK Icon was within 0.4% of the TPS value set at the time of commissioning using an ionization chamber. ROF for the 8 and 4-mm collimators were found to be 0.3% and 1.8% different from TPS values using the MicroDiamond detector and 2.6% and 1.9% different for film, respectively. Excellent agreement was found between TPS and measured dose profiles using the MicroDiamond detector which was within 1%/1 mm vs 2%/1 mm for film. Sector uniformity was found to be within 1% for all eight sectors measured using an ionization chamber. Verification of UCP and RFP coincidence using the MicroDiamond detector and pinprick film test was within 0.3 mm at isocenter for both. CONCLUSION: The annual QA of a LGK Icon was successfully performed by employing filmless techniques. Comparable results were obtained using radiochromic films. Utilizing active detectors instead of films simplifies the QA process and saves time without loss of accuracy.


Asunto(s)
Radiocirugia , Calibración , Diamante , Dosimetría por Película , Humanos , Radiometría
3.
J Appl Clin Med Phys ; 21(1): 95-102, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31943756

RESUMEN

Current available secondary dose calculation software for Gamma Knife radiosurgery falls short in situations where the target is shallow in depth or when the patient is positioned with a gamma angle other than 90°. In this work, we evaluate a new secondary calculation software which utilizes an innovative method to handle nonstandard gamma angles and image thresholding to render the skull for dose calculation. 800 treatment targets previously treated with our GammaKnife Icon system were imported from our treatment planning system (GammaPlan 11.0.3) and a secondary dose calculation was conducted. The agreement between the new calculations and the TPS were recorded and compared to the original secondary dose calculation agreement with the TPS using a Wilcoxon Signed Rank Test. Further comparisons using a Mann-Whitney test were made for targets treated at a 90° gamma angle against those treated with either a 70 or 110 gamma angle for both the new and commercial secondary dose calculation systems. Correlations between dose deviations from the treatment planning system against average target depth were evaluated using a Kendall's Tau correlation test for both programs. The Wilcoxon Signed Rank Test indicated a significant difference in the agreement between the two secondary calculations and the TPS, with a P-value < 0.0001. With respect to patients treated at nonstandard gamma angles, the new software was largely independent of patient setup, while the commercial software showed a significant dependence (P-value < 0.0001). The new secondary dose calculation software showed a moderate correlation with calculation depth, while the commercial software showed a weak correlation (Tau = -.322 and Tau = -.217 respectively). Overall, the new secondary software has better agreement with the TPS than the commercially available secondary calculation software over a range of diverse treatment geometries.


Asunto(s)
Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Craneales/cirugía , Programas Informáticos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Neoplasias Craneales/diagnóstico por imagen , Neoplasias Craneales/patología , Tomografía Computarizada por Rayos X/métodos
4.
J Appl Clin Med Phys ; 20(5): 21-26, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31055877

RESUMEN

PURPOSE: Characterize the intra-fraction motion management (IFMM) system found on the Gamma Knife Icon (GKI), including spatial accuracy, latency, temporal performance, and overall effect on delivered dose. METHODS: A phantom was constructed, consisting of a three-axis translation mount, a remote motorized flipper, and a thermoplastic sphere surrounding a radiation detector. An infrared marker was placed on the translation mount secured to the flipper. The spatial accuracy of the IFMM was measured via the translation mount in all Cartesian planes. The detector was centered at the radiation focal point. A remote signal was used to move the marker out of the IFMM tolerance and pause the beam. A two-channel electrometer was used to record the signals from the detector and the flipper when motion was signaled. These signals determined the latency and temporal performance of the GKI. RESULTS: The spatial accuracy of the IFMM was found to be <0.1 mm. The measured latency was <200 ms. The dose difference with five interruptions was <0.5%. CONCLUSION: This work provides a quantitative characterization of the GKI IFMM system as required by the Nuclear Regulatory Commission. This provides a methodology for GKI users to satisfy these requirements using common laboratory equipment in lieu of a commercial solution.


Asunto(s)
Movimiento , Neoplasias/cirugía , Fantasmas de Imagen , Radiocirugia/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Diseño de Equipo , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
7.
Phys Imaging Radiat Oncol ; 29: 100549, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38380154

RESUMEN

Background and purpose: Spatially fractionated radiation therapy (SFRT) has demonstrated promising clinical response in treating large tumors with heterogeneous dose distributions. Lattice stereotactic body radiation therapy (SBRT) is an SFRT technique that leverages inverse optimization to precisely localize regions of high and lose dose within disease. The aim of this study was to evaluate an automated heuristic approach to sphere placement in lattice SBRT treatment planning. Materials and methods: A script-based algorithm for sphere placement in lattice SBRT based on rules described by protocol was implemented within a treatment planning system. The script was applied to 22 treated cases and sphere distributions were compared with manually placed spheres in terms of number of spheres, number of protocol violations, and time required to place spheres. All cases were re-planned using script-generated spheres and plan quality was compared with clinical plans. Results: The mean number of spheres placed excluding those that violate rules was greater using the script (13.8) than that obtained by either dosimetrist (10.8 and 12.0, p < 0.001 and p = 0.003) or physicist (12.7, p = 0.061). The mean time required to generate spheres was significantly less using the script (2.5 min) compared to manual placement by dosimetrists (25.0 and 29.9 min) and physicist (19.3 min). Plan quality indices were similar in all cases with no significant differences, and OAR constraints remained met on all plans except two. Conclusion: A script placed spheres for lattice SBRT according to institutional protocol rules. The script-produced placement was superior to that of manually-specified spheres, as characterized by sphere number and rule violations.

8.
Clin Transl Radiat Oncol ; 39: 100577, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36718251

RESUMEN

Two abdominal patients were treated with Lattice stereotactic body radiation therapy (SBRT) using magnetic resonance guided radiation therapy (MRgRT). This is one of the first reported treatments of Lattice SBRT with the use of MRgRT. A description of the treatment approach and planning considerations were incorporated into this report. MRgRT Lattice SBRT delivered similar planning quality metrics to established dosimetric parameters for Lattice SBRT. Increased signal intensity were seen in the MRI treatments for one of the patients during the course of treatment.

9.
Phys Med ; 111: 102616, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37311338

RESUMEN

PURPOSE: To provide clinical guidance for centers wishing to implement photon spatially fractionated radiation therapy (SFRT) treatments using either a brass grid or volumetric modulated arc therapy (VMAT) lattice approach. METHODS: We describe in detail processes which have been developed over the course of a 3-year period during which our institution treated over 240 SFRT cases. The importance of patient selection, along with aspects of simulation, treatment planning, quality assurance, and treatment delivery are discussed. Illustrative examples involving clinical cases are shown, and we discuss safety implications relevant to the heterogeneous dose distributions. RESULTS: SFRT can be an effective modality for tumors which are otherwise challenging to manage with conventional radiation therapy techniques or for patients who have limited treatment options. However, SFRT has several aspects which differ drastically from conventional radiation therapy treatments. Therefore, the successful implementation of an SFRT treatment program requires the multidisciplinary expertise and collaboration of physicians, physicists, dosimetrists, and radiation therapists. CONCLUSIONS: We have described methods for patient selection, simulation, treatment planning, quality assurance and delivery of clinical SFRT treatments which were built upon our experience treating a large patient population with both a brass grid and VMAT lattice approach. Preclinical research and patient trials aimed at understanding the mechanism of action are needed to elucidate which patients may benefit most from SFRT, and ultimately expand its use.


Asunto(s)
Neoplasias , Radioterapia de Intensidad Modulada , Humanos , Fraccionamiento de la Dosis de Radiación , Neoplasias/radioterapia , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
10.
Radiother Oncol ; 167: 172-178, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34896459

RESUMEN

PURPOSE: Lattice stereotactic body radiation therapy (SBRT) is a form of spatially fractionated radiation therapy (SFRT) using SBRT methods. This study reports clinical dosimetric endpoints achieved for Lattice SBRT plans delivering 20 Gy in 5 fractions to the periphery of a tumor with a simultaneous integrated boost (SIB) of 66.7 Gy, as part of a prospective Phase I clinical trial (NCT04133415). Additionally, it updates previously reported planning and delivery techniques based on extended experience with a broader patient population. METHODS: Patients were enrolled on a single-arm phase I trial conducted between November 2019 and August 2020. Eligibility was restricted to tumors >4.5 cm in the largest dimension. Characteristic SFRT dose gradients were achieved using a lattice of 1.5 cm diameter spheres spaced within the GTV in a regular pattern, with peak-to-valley dose varying from 66.7 Gy to 20 Gy within 1.5 cm. Organ-at-risk (OAR) sparing followed AAPM TG101 recommendations for 5-fraction SBRT. RESULTS: Twenty patients (22 plans) were enrolled on study, with one additional plan treated off study. All OAR and target coverage planning objectives were achieved, with the exception of a single small bronchus. Conformity of the 20 Gy isodose line significantly improved over the course of the study. The majority (85.2%) of treatment fractions were delivered in a 30 minutes timeslot, with 4 (3.5%) exceeding a total treatment time of 40 minutes. CONCLUSION: Lattice SBRT planning techniques produce consistent and efficient treatment plans. Refined techniques described here further improve the quality of the planning technique.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Estudios Prospectivos , Radiocirugia/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
11.
JCO Glob Oncol ; 8: e2100284, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35609229

RESUMEN

PURPOSE: Disparities in radiation oncology (RO) can be attributed to geographic location, socioeconomic status, race, sex, and other societal factors. One potential solution is to implement a fully mobile (FM) RO system to bring radiotherapy to rural areas and reduce barriers to access. We use Monte Carlo simulation to quantify techno-economic feasibility with uncertainty, using two rural Missouri scenarios. METHODS: Recently, a semimobile RO system has been developed by building an o-ring linear accelerator (linac) into a mobile coach that is used for temporary care, months at a time. Transitioning to a more FM-RO system, which changes location within a given day, presents technical challenges including logistics and quality assurance. This simulation includes cancer census in both northern and southeastern Missouri, multiple treatment locations within a given day, and associated expenditures and revenues. A subset of patients with lung, breast, and rectal diseases, treated with five fractions, was simulated in the FM-RO system. RESULTS: The FM-RO can perform all necessary quality assurance tests as suggested in national medical physics guidelines within 1.5 hours, thus demonstrating technological feasibility. In northern and southeastern Missouri, five-fraction simulations' net incomes were, in US dollars (USD), $1.55 ± 0.17 million (approximately 74 patients/year) and $3.65 USD ± 0.25 million (approximately 98 patients/year), respectively. The number of patients seen had the highest correlation with net income as well as the ability to break-even within the simulation. The model does not account for disruptions in care or other commonly used treatment paradigms, which may lead to differences in estimated economic return. Overall, the mobile system achieved a net benefit, even for the most negative simulation scenarios. CONCLUSION: Our simulations suggest technologic success and economic viability for a FM-RO system within rural Missouri and present an interesting solution to address other geographic disparities in access to radiotherapy.


Asunto(s)
Oncología por Radiación , Simulación por Computador , Estudios de Factibilidad , Humanos , Método de Montecarlo , Aceleradores de Partículas
12.
Radiother Oncol ; 167: 317-322, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34875286

RESUMEN

PURPOSE: Stereotactic body radiotherapy (SBRT) is an attractive treatment option for patients with metastatic and/or unresectable tumors, however its use is limited to smaller tumors. Lattice is a form of spatially fractionated radiotherapy that may allow safe delivery of ablative doses to bulky tumors. We previously described Lattice SBRT, which delivers 20 Gy in 5 fractions with a simultaneous integrated boost to 66.7 Gy in a defined geometric arrangement (Lattice boost). The goal of this study was to prospectively evaluate the acute toxicity and quality of life (QoL) of patients with large tumors (>5 cm) treated with Lattice SBRT. METHODS: This was a single-arm phase I trial conducted between October 2019 and August 2020. Patients with tumors > 4.5 cm were eligible. Lattice SBRT was delivered every other day. The primary outcome was the rate of 90-day treatment-associated (probably or definitely attributable) grade 3 + acute toxicity by Common Terminology Criteria for Adverse Events (CTCAE) version 5.0 criteria. Other outcomes included changes in patient reported toxicity and QoL inventories, GTV, and peripheral blood cytokines. RESULTS: Twenty patients (22 tumors) were enrolled. Median GTV was 579.2 cc (range: 54.2-3713.5 cc) in volume and 11.1 cm (range: 5.6-21.4 cm) in greatest axial diameter. Fifty percent of tumors were in the thorax, 45% abdomen/pelvis, and 5% extremity. There was no likely treatment-associated grade 3 + toxicity in the 90-day period (acute and sub-acute). There was one case of grade 4 toxicity possibly associated with Lattice SBRT. CONCLUSIONS: This phase I study met its primary endpoint of physician reported short-term safety. An ongoing phase II clinical trial of Lattice SBRT will evaluate late safety and efficacy of this novel technique.


Asunto(s)
Neoplasias , Radiocirugia , Humanos , Neoplasias/radioterapia , Calidad de Vida , Radiocirugia/efectos adversos , Radiocirugia/métodos
13.
J Neurosurg ; 135(3): 855-861, 2020 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-33307528

RESUMEN

OBJECTIVE: The internal high-dose volume varies widely for a given prescribed dose during stereotactic radiosurgery (SRS) to treat brain metastases (BMs). This may be altered during treatment planning, and the authors have previously shown that this improves local control (LC) for non-small cell lung cancer BMs without increasing toxicity. Here, they seek to identify potentially actionable dosimetric predictors of LC after SRS for melanoma BM. METHODS: The records of patients with unresected melanoma BM treated with single-fraction Gamma Knife RS between 2006 and 2017 were reviewed. LC was assessed on a per-lesion basis, defined as stability or a decrease in lesion size. Outcome-oriented approaches were utilized to determine optimal dichotomization for dosimetric variables relative to LC. Univariable and multivariable Cox regression analysis was implemented to evaluate the impact of collected parameters on LC. RESULTS: Two hundred eighty-seven melanoma BMs in 79 patients were identified. The median age was 56 years (range 31-86 years). The median follow-up was 7.6 months (range 0.5-81.6 months), and the median survival was 9.3 months (range 1.3-81.6 months). Lesions were optimally stratified by volume receiving at least 30 Gy (V30) greater than or equal to versus less than 25%. V30 was ≥ and < 25% in 147 and 140 lesions, respectively. For all patients, 1-year LC was 83% versus 66% for V30 ≥ and < 25%, respectively (p = 0.001). Stratifying by volume, lesions 2 cm or less (n = 215) had 1-year LC of 82% versus 70% (p = 0.013) for V30 ≥ and < 25%, respectively. Lesions > 2 to 3 cm (n = 32) had 1-year LC of 100% versus 43% (p = 0.214) for V30 ≥ and < 25%, respectively. V30 was still predictive of LC even after controlling for the use of immunotherapy and targeted therapy. Radionecrosis occurred in 2.8% of lesions and was not significantly associated with V30. CONCLUSIONS: For a given prescription dose, an increased internal high-dose volume, as indicated by measures such as V30 ≥ 25%, is associated with improved LC but not increased toxicity in single-fraction SRS for melanoma BM. Internal dose escalation is an independent predictor of improved LC even in patients receiving immunotherapy and/or targeted therapy. This represents a dosimetric parameter that is actionable at the time of treatment planning and warrants further evaluation.

14.
Int J Radiat Oncol Biol Phys ; 104(5): 1114-1123, 2019 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-31002942

RESUMEN

PURPOSE: A prospective phase 1/2 trial for electrophysiologic guided noninvasive cardiac radioablation treatment of ventricular tachycardia (ENCORE-VT) demonstrating efficacy for arrhythmia control has recently been reported. The treatment workflow, report dose-volume metrics, and overall process improvements are described here. METHODS AND MATERIALS: Patients receiving 25 Gy in a single fraction to the cardiac ventricular tachycardia substrate (identified on presimulation multimodality imaging) on the phase 1/2 trial were included for analysis. Planning target volume (PTV), R50, monitor unit ratio, and gradient measure values were compared over time using statistical process control. Outlier values in the dose-volume histogram (DVH) for PTV and organs at risk were identified by calculating inner fences based on the interquartile range. Median heart substructure doses are also reported. RESULTS: For the 16 trial patients included, the median target volumes for the gross "target" volumes, internal target volumes, and PTVs were 25.1 cm3 (minimum: 11.5 cm3, maximum: 54.9 cm3), 30.1 cm3 (17.7, 81.6), and 97.9 cm3 (66, 208.5), respectively. On statistical process control analysis, there was a significant decrease in PTV volume among the more recent cohort of cases and mean doses to the nontargeted heart (heart - PTV). Two patients had heart-minus-PTV, esophagus, and stomach DVH data significantly higher than inner fence, and 3 patients had spinal cord DVH data higher than the inner fence, but in all cases the deviations were clinically acceptable. Subjective decreases were seen in the R50, gradient measure, and treatment time from the first to last patient in this series. All plans were verified in phantom with ionization chamber measurements within 2.9% of the expected dose value. CONCLUSIONS: Over the duration of this trial, PTV volumes to the cardiac substrate target decreased significantly, and organ-at-risk constraints were met for all cases. Future directions for this clinical process will include incorporating knowledge-based planning techniques and evaluating the need for substructure optimization.


Asunto(s)
Corazón/efectos de la radiación , Órganos en Riesgo/efectos de la radiación , Radiocirugia/estadística & datos numéricos , Taquicardia Ventricular/radioterapia , Flujo de Trabajo , Esófago/efectos de la radiación , Humanos , Evaluación de Procesos, Atención de Salud , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Médula Espinal/efectos de la radiación , Estómago/efectos de la radiación
15.
Pract Radiat Oncol ; 9(2): e218-e227, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30562615

RESUMEN

PURPOSE: This study aimed to evaluate the feasibility of using a single-institution, knowledge-based planning (KBP) model as a dosimetric plan quality control (QC) for multi-institutional clinical trials. The efficacy of this QC tool was retrospectively evaluated using a subset of plans submitted to Radiation Therapy Oncology Group (RTOG) study 0617. METHODS AND MATERIALS: A single KBP model was created using commercially available software (RapidPlan; Varian Medical Systems, Palo Alto, CA) and data from 106 patients with non-small cell lung cancer who were treated at a single institution. All plans had prescriptions that ranged from 60 Gy in 30 fractions to 74 Gy in 37 fractions and followed the planning guidelines from RTOG 0617. Two sets of optimization objectives were created to produce different trade-offs using the single KBP model predictions: one prioritizing target coverage and a second prioritizing lung sparing (LS) while allowing an acceptable variation in target coverage. Three institutions submitted a high volume of clinical plans to RTOG 0617 and provided data on 25 patients, which were replanned using both sets of optimization objectives. Model-generated, dose-volume histogram predictions were used to identify patients who exceeded the lung clinical target volume (CTV) V20Gy >37% and would benefit from the LS objectives. Overall plan quality differences between KBP-generated plans and clinical plans were evaluated at RTOG 0617-defined dosimetric endpoints. RESULTS: Target coverage and organ at risk sparing was significantly improved for most KBP-generated plans compared with those from clinical trial data. The KBP model using prioritized target coverage objectives reduced heart Dmean and V40Gy by 2.1 Gy and 5.2%, respectively. Similarly, using LS objectives reduced the lung CTV Dmean and V20Gy by 2.0 Gy and 2.9%, respectively. The KBP predictions correctly identified all patients with lung CTV V20Gy > 37% (5 of 25 patients) and significantly reduced the dose to the lung CTV by applying the LS optimization objectives. CONCLUSIONS: A single-institution KBP model can be applied as a QC tool for multi-institutional clinical trials to improve overall plan quality and provide decision-support to determine the need for anatomy-based dosimetric trade-offs.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Bases del Conocimiento , Neoplasias Pulmonares/radioterapia , Modelos Biológicos , Planificación de la Radioterapia Asistida por Computador/métodos , Sistemas de Apoyo a Decisiones Clínicas , Fraccionamiento de la Dosis de Radiación , Estudios de Factibilidad , Humanos , Órganos en Riesgo/efectos de la radiación , Control de Calidad , Radiometría/métodos , Programas Informáticos
17.
Pract Radiat Oncol ; 9(5): 305-321, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30999000

RESUMEN

PURPOSE: Although the wind, rain, and flooding of Hurricane Maria in Puerto Rico abated shortly after its landfall on September 20, 2017, the disruption of the electrical, communications, transportation, and medical infrastructure of the island was unprecedented in scope and caused lasting harm for many months afterward. A compilation of recommendations from radiation oncologists who were in Puerto Rico during the disaster, and from a panel of American Society for Radiation Oncology (ASTRO) cancer experts was created. METHODS AND MATERIALS: Radiation oncologists throughout Puerto Rico collaborated and improvised to continue treating patients in the immediate aftermath of the storm and as routine clinical operations were restored gradually. Empirical lessons from the experience of radiation therapy administration in this profoundly altered context of limited resources, impaired communication, and inadequate transportation were organized into a recommended template, applicable to any radiation oncology practice. ASTRO disease-site experts provided evidence-guidelines for mitigating the impact of a 2- to 3-week interruption in radiation therapy. RESULTS: Practical measures to mitigate the medical impact of a disaster are summarized within the framework of "Prepare, Communicate, Operate, Compensate." Specific measures include the development of an emergency operations plan tailored to specific circumstances, prospective coordination with other radiation oncology clinics before a disaster, ongoing communications with emergency management organizations, and routine practice of alternate methods to disseminate information among providers and patients. CONCLUSIONS: These recommendations serve as a starting point to assist any radiation oncology practice in becoming more resiliently prepared for a local or regional disruption from any cause. Disease-site experts provide evidence-based guidelines on how to mitigate the impact of a 2- to 3-week interruption in radiation therapy for lung, head and neck, uterine cervix, breast, and prostate cancers through altered fractionation or dose escalation.


Asunto(s)
Tormentas Ciclónicas/mortalidad , Desastres Naturales/mortalidad , Oncología por Radiación/normas , Humanos , Puerto Rico
18.
Med Phys ; 40(2): 021724, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23387747

RESUMEN

PURPOSE: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. METHODS: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. RESULTS: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94.62%, respectively, for the bolus ECT plans and 89.2% and 95.1%, respectively, for the mixed beam plans. For all regions, pass rates for the parotid and CW plans were 98.8% and 97.3%, respectively, for the bolus ECT plans and 97.5% and 95.9%, respectively, for the mixed beam plans. For the IMXT component of the mixed beam plans, pass rates for the parotid and CW plans were 93.7% and 95.8%. CONCLUSIONS: Bolus ECT and mixed beam therapy dose delivery to the phantom were more accurate than IMXT delivery, adding confidence to the use of planning, fabrication, and delivery for bolus ECT tools either alone or as part of mixed beam therapy. The methodology reported in this work could serve as a basis for future standardization of the commissioning of bolus ECT or mixed beam therapy. When applying this technology to patients, it is recommended that an electron dose algorithm more accurate than the pencil beam algorithm, e.g., a Monte Carlo algorithm or analytical transport such as the pencil beam redefinition algorithm, be used for planning to ensure the desired accuracy.


Asunto(s)
Electrones/uso terapéutico , Radioterapia de Intensidad Modulada/métodos , Humanos , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador