1.
Anal Chem ; 96(21): 8234-8242, 2024 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-38739527

RESUMEN

Mass spectrometry has been increasingly explored in intraoperative studies as a potential technology to help guide surgical decision making. Yet, intraoperative experiments using high-performance mass spectrometry instrumentation present a unique set of operational challenges. For example, standard operating rooms are often not equipped with the electrical requirements to power a commercial mass spectrometer and are not designed to accommodate their permanent installation. These obstacles can impact progress and patient enrollment in intraoperative clinical studies because implementation of MS instrumentation becomes limited to specific operating rooms that have the required electrical connections and space. To expand our intraoperative clinical studies using the MasSpec Pen technology, we explored the feasibility of transporting and acquiring data on Orbitrap mass spectrometers operating on battery power in hospital buildings. We evaluated the effect of instrument movement including acceleration and rotational speeds on signal stability and mass accuracy by acquiring data using direct infusion electrospray ionization. Data were acquired while rolling the systems in/out of operating rooms and while descending/ascending a freight elevator. Despite these movements and operating the instrument on battery power, the relative standard deviation of the total ion current was <5% and the magnitude of the mass error relative to the internal calibrant never exceeded 5.06 ppm. We further evaluated the feasibility of performing intraoperative MasSpec Pen analysis while operating the Orbitrap mass spectrometer on battery power during an ovarian cancer surgery. We observed that the rich and tissue-specific molecular profile commonly detected from ovarian tissues was conserved when running on battery power. Together, these results demonstrate that Orbitrap mass spectrometers can be operated and acquire data on battery power while in motion and in rotation without losses in signal stability or mass accuracy. Furthermore, Orbitrap mass spectrometers can be used in conjunction to the MasSpec Pen while on battery power for intraoperative tissue analysis.


Asunto(s)
Suministros de Energía Eléctrica , Humanos , Espectrometría de Masas/métodos , Femenino , Neoplasias Ováricas/cirugía
2.
JAMA Netw Open ; 7(3): e242684, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38517441

RESUMEN

Importance: Surgery with complete tumor resection remains the main treatment option for patients with breast cancer. Yet, current technologies are limited in providing accurate assessment of breast tissue in vivo, warranting development of new technologies for surgical guidance. Objective: To evaluate the performance of the MasSpec Pen for accurate intraoperative assessment of breast tissues and surgical margins based on metabolic and lipid information. Design, Setting, and Participants: In this diagnostic study conducted between February 23, 2017, and August 19, 2021, the mass spectrometry-based device was used to analyze healthy breast and invasive ductal carcinoma (IDC) banked tissue samples from adult patients undergoing breast surgery for ductal carcinomas or nonmalignant conditions. Fresh-frozen tissue samples and touch imprints were analyzed in a laboratory. Intraoperative in vivo and ex vivo breast tissue analyses were performed by surgical staff in operating rooms (ORs) within 2 different hospitals at the Texas Medical Center. Molecular data were used to build statistical classifiers. Main Outcomes and Measures: Prediction results of tissue analyses from classification models were compared with gross assessment, frozen section analysis, and/or final postoperative pathology to assess accuracy. Results: All data acquired from the 143 banked tissue samples, including 79 healthy breast and 64 IDC tissues, were included in the statistical analysis. Data presented rich molecular profiles of healthy and IDC banked tissue samples, with significant changes in relative abundances observed for several metabolic species. Statistical classifiers yielded accuracies of 95.6%, 95.5%, and 90.6% for training, validation, and independent test sets, respectively. A total of 25 participants enrolled in the clinical, intraoperative study; all were female, and the median age was 58 years (IQR, 44-66 years). Intraoperative testing of the technology was successfully performed by surgical staff during 25 breast operations. Of 273 intraoperative analyses performed during 25 surgical cases, 147 analyses from 22 cases were subjected to statistical classification. Testing of the classifiers on 147 intraoperative mass spectra yielded 95.9% agreement with postoperative pathology results. Conclusions and Relevance: The findings of this diagnostic study suggest that the mass spectrometry-based system could be clinically valuable to surgeons and patients by enabling fast molecular-based intraoperative assessment of in vivo and ex vivo breast tissue samples and surgical margins.


Asunto(s)
Neoplasias de la Mama , Adulto , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Márgenes de Escisión , Mama/cirugía , Mama/patología , Mastectomía , Espectrometría de Masas