RESUMEN
We report on the case of a French citizen who was found dead in his home, 4 days after returning from Cameroon. The patient died of imported malaria, as revealed by the postmortem investigations. Few such cases have been reported throughout the world. This article reviews deaths due to malaria diagnosed at the time of autopsy in France between 1995 and 2005. We conclude that the nonspecific symptoms of malaria can lead to a misdiagnosis and the need for a forensic expert to intervene at the scene of death, which usually occurs in the home. We will remind forensic pathologists of the clinical, biologic, and forensic aspects of this infectious disease. In particular, the uses of microbiologic analyses, the QBC malaria test and the Core malaria Pan/Pv/pf test as well as brain tissue histology will be reviewed.
Asunto(s)
Errores Diagnósticos , Malaria Cerebral/diagnóstico , Viaje , Adulto , Encéfalo/parasitología , Encéfalo/patología , Camerún , Eritrocitos/parasitología , Patologia Forense , Francia , Humanos , Hígado/patología , Pulmón/patología , Macrófagos/patología , Masculino , Plasmodium falciparum/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Bazo/patologíaRESUMEN
Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum samples collected over a 2-month period in the hospital of Nice were examined for markers of HBV infection (HBsAg, anti-HBs and anti-HBc). One hundred seven samples with sufficient volume and with borderline reactivity by the ARCHITECT assay were tested by two other anti-HBc assays, a microparticle enzyme immunoassay (MEIA, AxSYM Core, Abbott Laboratories, IL, USA) and an enzyme linked fluorescent assay (ELFA, VIDAS Anti-HBc Total II, bioMérieux, Lyon, France). Only 46 samples were confirmed by the AxSYM and the VIDAS assays. Additional serological information linked to patient history showed that the remaining samples (61) were false positives (11), had low titer of anti-HBc antibodies (13), or were inconclusive (37). This comparative study highlighted the existence of a grey zone around the cut-off index. Confirmative results through a different immunoassay are needed to confirm the diagnosis of HBV on borderline reactive sera using the ARCHITECT anti-HBc assay.