Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Emerg Med J ; 41(1): 4-12, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-37739766

RESUMEN

BACKGROUND: Acute behavioural disturbance (ABD) is a term used in law enforcement and healthcare, but there is a lack of clarity regarding its meaning. Common language should be used across staff groups to support the identification, prioritisation and delivery of care to this group of patients. The terminology currently used is inconsistent and confusing. This study aimed to reach a consensus on the criteria for identification and management of ABD, and to agree when other care pathways or guidelines might be more appropriately used. METHODS: A modified Delphi study with participation from stakeholder organisation representatives was conducted in January-April 2023 online. In round 1, statements were generated by participants in response to broad questions. Participants then rated their level of agreement with statements in subsequent rounds, with statements achieving a consensus removed for inclusion in the final derived consensus statement. Non-consensus statement responses were assessed for stability. RESULTS: Of 430 unique statements presented for rating, 266 achieved a consensus among 30 participants representing eight stakeholder organisations. A derived consensus statement was generated from these statements. The median group response to statements which failed to achieve a consensus was reliable (Krippendorff's alpha=0·67). CONCLUSIONS: There is a consensus across stakeholder organisations that ABD is not a separate entity to agitation, and guidance should instead be altered to address the full range of presentations of agitation. While the features of concern in this severely agitated group of patients can be described, the advice for recognition may vary depending on staff group. Criteria for recognition are provided and potential new terminology is described.


Asunto(s)
Técnica Delphi , Humanos , Consenso , Reino Unido
2.
Opt Express ; 27(12): 16791-16797, 2019 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-31252899

RESUMEN

We report on the direct intensity modulation characteristics of a high-speed resonant tunneling diode-photodetector (RTD-PD) with an oscillation frequency of 79 GHz. This work demonstrates both electrical and optical modulation and shows that RTD-PD oscillators can be utilized as versatile optoelectronic/radio interfaces. This is the first demonstration of optical modulation of an RF carrier using integrated RTD-PD oscillators at microwave frequencies.

3.
Cochrane Database Syst Rev ; 9: CD007701, 2017 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-28901007

RESUMEN

BACKGROUND: Induction of labour is carried out for a variety of indications and using a range of methods. For women at low risk of pregnancy complications, some methods of induction of labour or cervical ripening may be suitable for use in outpatient settings. OBJECTIVES: To examine pharmacological and mechanical interventions to induce labour or ripen the cervix in outpatient settings in terms of effectiveness, maternal satisfaction, healthcare costs and, where information is available, safety. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 November 2016) and reference lists of retrieved studies. SELECTION CRITERIA: We included randomised controlled trials examining outpatient cervical ripening or induction of labour with pharmacological agents or mechanical methods. Cluster trials were eligible for inclusion. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. We assessed evidence using the GRADE approach. MAIN RESULTS: This updated review included 34 studies of 11 different methods for labour induction with 5003 randomised women, where women received treatment at home or were sent home after initial treatment and monitoring in hospital.Studies examined vaginal and intracervical prostaglandin E2 (PGE2), vaginal and oral misoprostol, isosorbide mononitrate, mifepristone, oestrogens, amniotomy and acupuncture, compared with placebo, no treatment, or routine care. Trials generally recruited healthy women with a term pregnancy. The risk of bias was mostly low or unclear, however, in 16 trials blinding was unclear or not attempted. In general, limited data were available on the review's main and additional outcomes. Evidence was graded low to moderate quality. 1. Vaginal PGE2 versus expectant management or placebo (5 studies)Fewer women in the vaginal PGE2 group needed additional induction agents to induce labour, however, confidence intervals were wide (risk ratio (RR) 0.52, 95% confidence interval (CI) 0.27 to 0.99; 150 women; 2 trials). There were no clear differences between groups in uterine hyperstimulation (with or without fetal heart rate (FHR) changes) (RR 3.76, 95% CI 0.64 to 22.24; 244 women; 4 studies; low-quality evidence), caesarean section (RR 0.80, 95% CI 0.49 to 1.31; 288 women; 4 studies; low-quality evidence), or admission to a neonatal intensive care unit (NICU) (RR 0.32, 95% CI 0.10 to 1.03; 230 infants; 3 studies; low-quality evidence).There was no information on vaginal birth within 24, 48 or 72 hours, length of hospital stay, use of emergency services or maternal or caregiver satisfaction. Serious maternal and neonatal morbidity or deaths were not reported. 2. Intracervical PGE2 versus expectant management or placebo (7 studies) There was no clear difference between women receiving intracervical PGE2 and no treatment or placebo in terms of need for additional induction agents (RR 0.98, 95% CI 0.74 to 1.32; 445 women; 3 studies), vaginal birth not achieved within 48 to 72 hours (RR 0.83, 95% CI 0.68 to 1.02; 43 women; 1 study; low-quality evidence), uterine hyperstimulation (with FHR changes) (RR 2.66, 95% CI 0.63 to 11.25; 488 women; 4 studies; low-quality evidence), caesarean section (RR 0.90, 95% CI 0.72 to 1.12; 674 women; 7 studies; moderate-quality evidence), or babies admitted to NICU (RR 1.61, 95% CI 0.43 to 6.05; 215 infants; 3 studies; low-quality evidence). There were no uterine ruptures in either the PGE2 group or placebo group.There was no information on vaginal birth not achieved within 24 hours, length of hospital stay, use of emergency services, mother or caregiver satisfaction, or serious morbidity or neonatal morbidity or perinatal death. 3. Vaginal misoprostol versus placebo (4 studies)One small study reported on the rate of perinatal death with no clear differences between groups; there were no deaths in the treatment group compared with one stillbirth (reason not reported) in the control group (RR 0.34, 95% CI 0.01 to 8.14; 77 infants; 1 study; low-quality evidence).There was no clear difference between groups in rates of uterine hyperstimulation with FHR changes (RR 1.97, 95% CI 0.43 to 9.00; 265 women; 3 studies; low-quality evidence), caesarean section (RR 0.94, 95% CI 0.61 to 1.46; 325 women; 4 studies; low-quality evidence), and babies admitted to NICU (RR 0.89, 95% CI 0.54 to 1.47; 325 infants; 4 studies; low-quality evidence).There was no information on vaginal birth not achieved within 24, 48 or 72 hours, additional induction agents required, length of hospital stay, use of emergency services, mother or caregiver satisfaction, serious maternal, and other neonatal, morbidity or death.No substantive differences were found for other comparisons. One small study found that women who received oral misoprostol were more likely to give birth within 24 hours (RR 0.65, 95% CI 0.48 to 0.86; 87 women; 1 study) and were less likely to require additional induction agents (RR 0.60, 95% CI 0.37 to 0.97; 127 women; 2 studies). Women who received mifepristone were also less likely to require additional induction agents (average RR 0.59, 95% CI 0.37 to 0.95; 311 women; 4 studies; I² = 74%); however, this result should be interpreted with caution due to high heterogeneity. One trial each of acupuncture and outpatient amniotomy were included, but few review outcomes were reported. AUTHORS' CONCLUSIONS: Induction of labour in outpatient settings appears feasible and important adverse events seem rare, however, in general there is insufficient evidence to detect differences. There was no strong evidence that agents used to induce labour in outpatient settings had an impact (positive or negative) on maternal or neonatal health. There was some evidence that compared to placebo or no treatment, induction agents administered on an outpatient basis reduced the need for further interventions to induce labour, and shortened the interval from intervention to birth.We do not have sufficient evidence to know which induction methods are preferred by women, the interventions that are most effective and safe to use in outpatient settings, or their cost effectiveness. Further studies where various women-friendly outpatient protocols are compared head-to-head are required. As part of such work, women should be consulted on what sort of management they would prefer.


Asunto(s)
Atención Ambulatoria , Trabajo de Parto Inducido/métodos , Terapia por Acupuntura/métodos , Cesárea/estadística & datos numéricos , Dinoprostona/administración & dosificación , Estudios de Factibilidad , Femenino , Humanos , Cuidado Intensivo Neonatal/estadística & datos numéricos , Misoprostol/administración & dosificación , Oxitócicos , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Appl Opt ; 56(4): 1079-1086, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28158115

RESUMEN

In this paper, we have experimentally investigated the optimized bias current of semiconductor optical amplifiers (SOAs) to achieve high-speed input pulse train amplification with high gain and low distortion. Variations of the amplified output pulse duration with the amplifier bias currents have been analyzed and, compared to the input pulse duration, the amplified output pulse duration is broadened. As the SOA bias current decreases from the high level (larger than the saturated bias current) to the low level, the broadened pulse duration of the amplified output pulse initially decreases slowly and then rapidly. Based on the analysis, an optimized bias current of SOA for high-speed pulse train amplification is introduced. The relation between the SOA optimized bias current and the parameters of the input pulse train (pulse duration, power, and repetition rate) are experimentally studied. It is found that the larger the input pulse duration, the lower the input pulse power or a higher repetition rate can lead to a larger SOA optimized bias current, which corresponds to a larger optimized SOA gain. The effects of assist light injection and different amplifier temperatures on the SOA optimized bias current are studied and it is found that assist light injection can effectively increase the SOA optimized bias current while SOA has a lower optimized bias current at the temperature 20°C than that at other temperatures.

5.
6.
Opt Express ; 24(23): 26838-26850, 2016 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-27857412

RESUMEN

Indoor visible light communications (VLC) combines illumination and communication by utilizing the high-modulation-speed of LEDs. VLC is anticipated to be complementary to radio frequency communications and an important part of next generation heterogeneous networks. In order to make the maximum use of VLC technology in a networking environment, we need to expand existing research from studies of traditional point-to-point links to encompass scheduling and resource allocation related to multi-user scenarios. This work aims to maximize the downlink throughput of an indoor VLC network, while taking both user fairness and time latency into consideration. Inter-user interference is eliminated by appropriately allocating LEDs to users with the aid of graph theory. A three-term priority factor model is derived and is shown to improve the throughput performance of the network scheduling scheme over those previously reported. Simulations of VLC downlink scheduling have been performed under proportional fairness scheduling principles where our newly formulated priority factor model has been applied. The downlink throughput is improved by 19.6% compared to previous two-term priority models, while achieving similar fairness and latency performance. When the number of users grows larger, the three-term priority model indicates an improvement in Fairness performance compared to two-term priority model scheduling.

7.
Opt Express ; 24(16): 18163-75, 2016 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-27505781

RESUMEN

The integration of light sources on a photonic platform is a key aspect of the fabrication of self-contained photonic circuits with a small footprint that does not have a definitive solution yet. Several approaches are being actively researched for this purpose. In this work we propose optoelectronic tweezers for the manipulation and integration of light sources on a photonic platform and report the positional and angular accuracy of the micromanipulation of standard Fabry-Pérot InP semiconductor laser die. These lasers are over three orders of magnitude bigger in volume than any previously assembled with optofluidic techniques and the fact that they are industry standard lasers makes them significantly more useful than previously assembled microdisk lasers. We measure the accuracy to be 2.5 ± 1.4 µm and 1.4 ± 0.4° and conclude that optoelectronic tweezers are a promising technique for the micromanipulation and integration of optoelectronic components in general and semiconductor lasers in particular.

8.
Cochrane Database Syst Rev ; 12: CD006901, 2016 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-27918616

RESUMEN

BACKGROUND: Sometimes it is necessary to bring on labour artificially because of safety concerns for the mother or baby. This review is one of a series of reviews of methods of labour induction using a standardised protocol. OBJECTIVES: To determine the effects of NO donors (isosorbide mononitrate (ISMN), isosorbide dinitrate (ISDN), nitroglycerin and sodium nitroprusside) for third trimester cervical ripening or induction of labour, in comparison with placebo or no treatment or other treatments from a predefined hierarchy. SEARCH METHODS: We searched Cochrane Pregnancy and Childbirth's Trials Register (15 August 2016) and the reference lists of trial reports. SELECTION CRITERIA: Clinical trials comparing NO donors for cervical ripening or labour induction with other methods listed above it on a predefined list of methods of labour induction. Interventions include NO donors (isosorbide mononitrate, isosorbide dinitrate, nitroglycerin and sodium nitroprusside) compared with other methods listed above it on a predefined list of methods of labour induction. DATA COLLECTION AND ANALYSIS: This review is part of a series of reviews focusing on methods of induction of labour, based on a generic protocol. Three review authors independently assessed trials for inclusion, assessed risk of bias and extracted data. In this update, the quality of the evidence for the main comparison was assessed using the GRADE approach. MAIN RESULTS: We included 23 trials (including a total of 4777 women). Included studies compared NO donors with placebo, vaginal prostaglandin E2 (PGE2), intracervical PGE2, vaginal misoprostol and intracervical Foley catheter. The majority of the included studies were assessed as being at low risk of bias. Nitric oxide versus placebo There was no evidence of a difference for any of the primary outcomes analysed: vaginal delivery not achieved in 24 hours (risk ratio (RR) 0.97, 95% confidence interval (CI) 0.83 to 1.15; one trial, 238 women; low-quality evidence), uterine hyperstimulation with fetal heart rate (FHR) changes (RR 0.09, 95% CI 0.01 to 1.62; two trials, 300 women; low-quality evidence), caesarean section (RR 0.99, 95% CI 0.88 to 1.11; nine trials, 2624 women; moderate-quality evidence) or serious neonatal morbidity/perinatal death (average RR 1.61, 95% CI 0.08 to 33.26; two trials, 1712 women; low-quality evidence). There were no instances of serious maternal morbidity or death (one study reported this outcome).There was a reduction in an unfavourable cervix at 12 to 24 hours in women treated with NO donors (average RR 0.78, 95% CI 0.67 to 0.90; four trials, 762 women), and this difference was observed in both subgroups of standard release and slow release formulation. Women who received NO donors were less likely to experience uterine hyperstimulation without FHR rate changes (RR 0.05, 95% CI 0.00 to 0.80; one trial, 200 women), and more likely to experience side effects, including nausea, headache and vomiting. Nitric oxide donors versus vaginal prostaglandins There was no evidence of any difference between groups for uterine hyperstimulation with FHR changes or caesarean section (RR 0.97, 95% CI 0.78 to 1.21; three trials, 571 women). Serious neonatal morbidity and serious maternal morbidity were not reported. There were fewer women in the NO donor group who did not achieve a vaginal delivery within 24 hours (RR 0.63, 95% CI 0.47 to 0.86; one trial, 400 primiparae women). Nitric oxide donors versus intracervical prostaglandins One study reported a reduction in the number of women who had not achieved a vaginal delivery within 24 hours with NO donors (RR 0.63, 95% CI 0.47 to 0.86; one trial, 400 women). This result should be interpreted with caution as the information was extracted from an abstract only and a full report of the study is awaited. No differences were observed between groups for uterine hyperstimulation with FHR changes (RR 0.33, 95% CI 0.01 to 7.74; one trial, 42 women) or serious neonatal morbidity/perinatal death (RR 0.33, 95% CI 0.01 to 7.74; one trial, 42 women). Fewer women in the NO donor group underwent a caesarean section in comparison to women who received intracervical prostaglandins (RR 0.63, 95% CI 0.44 to 0.90; two trials, 442 women). No study reported on the outcome serious maternal morbidity or death. Nitric oxide donors versus vaginal misoprostol There was a reduction in the rate of uterine hyperstimulation with FHR changes with NO donors (RR 0.07, 95% CI 0.01 to 0.37; three trials, 281 women). There were no differences in caesarean section rates (RR 1.00, 95% CI 0.82 to 1.21; 761 women; six trials) and no cases of serious neonatal morbidity/perinatal death were reported. One study found that women in the NO donor group were more likely to not deliver within 24 hours (RR 5.33, 95% CI 1.62 to 17.55; one trial, 150 women). Serious maternal morbidity or death was not reported.In terms of secondary outcomes, there was an increase in cervix unchanged/unfavourable with NO (RR 3.43, 95% CI 2.07 to 5.66; two trials, 151 women) and an increase in the need for oxytocin augmentation with NO induction (RR 2.67, 95% CI 1.31 to 5.45; 7 trials; 767 women), although there was evidence of significant heterogeneity which could not be fully explained. Uterine hyperstimulation without FHR was lower in the NO group, as was meconium-stained liquor, Apgar score less than seven at five minutes and analgesia requirements. Nitric oxide donors versus intracervical catheter There was no evidence on any difference between the effects of NO and the use of a Foley catheter for induction of labour for caesarean section (RR 1.00, 95% CI 0.39 to 2.59; one trial, 80 women). No other primary outcomes were reported. One study of 75 participants did not contribute any data to the review.For all comparisons, women who received NO donors were more likely to experience side effects such as headache, nausea or vomiting. AUTHORS' CONCLUSIONS: Available data suggests that NO donors can be a useful tool in the process of induction of labour causing the cervix to be more favourable in comparison to placebo. However, additional data are needed to assess the true impact of NO donors on all important labour process and delivery outcomes.


Asunto(s)
Maduración Cervical/efectos de los fármacos , Trabajo de Parto Inducido/métodos , Donantes de Óxido Nítrico , Administración Intravaginal , Maduración Cervical/fisiología , Dinoprostona , Femenino , Humanos , Misoprostol , Oxitócicos , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto , Cateterismo Urinario
9.
Cochrane Database Syst Rev ; (5): CD010607, 2016 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-27168518

RESUMEN

BACKGROUND: Hyperemesis gravidarum is a severe form of nausea and vomiting in pregnancy affecting 0.3% to 1.0% of pregnancies, and is one of the most common indications for hospitalization during pregnancy. While a previous Cochrane review examined interventions for nausea and vomiting in pregnancy, there has not yet been a review examining the interventions for the more severe condition of hyperemesis gravidarum. OBJECTIVES: To assess the effectiveness and safety, of all interventions for hyperemesis gravidarum in pregnancy up to 20 weeks' gestation. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register and the Cochrane Complementary Medicine Field's Trials Register (20 December 2015) and reference lists of retrieved studies. SELECTION CRITERIA: Randomized controlled trials of any intervention for hyperemesis gravidarum. Quasi-randomized trials and trials using a cross-over design were not eligible for inclusion.We excluded trials on nausea and vomiting of pregnancy that were not specifically studying the more severe condition of hyperemesis gravidarum. DATA COLLECTION AND ANALYSIS: Two review authors independently reviewed the eligibility of trials, extracted data and evaluated the risk of bias. Data were checked for accuracy. MAIN RESULTS: Twenty-five trials (involving 2052 women) met the inclusion criteria but the majority of 18 different comparisons described in the review include data from single studies with small numbers of participants. The comparisons covered a range of interventions including acupressure/acupuncture, outpatient care, intravenous fluids, and various pharmaceutical interventions. The methodological quality of included studies was mixed. For selected important comparisons and outcomes, we graded the quality of the evidence and created 'Summary of findings' tables. For most outcomes the evidence was graded as low or very low quality mainly due to the imprecision of effect estimates. Comparisons included in the 'Summary of findings' tables are described below, the remaining comparisons are described in detail in the main text.No primary outcome data were available when acupuncture was compared with placebo, There was no clear evidence of differences between groups for anxiodepressive symptoms (risk ratio (RR) 1.01, 95% confidence interval (CI) 0.73 to 1.40; one study, 36 women, very low-quality evidence), spontaneous abortion (RR 0.48, 95% CI 0.05 to 5.03; one study, 57 women, low-quality evidence), preterm birth (RR 0.12, 95% CI 0.01 to 2.26; one study, 36 women, low-quality evidence), or perinatal death (RR 0.57, 95% CI 0.04 to 8.30; one study, 36 women, low-quality evidence).There was insufficient evidence to identify clear differences between acupuncture and metoclopramide in a study with 81 participants regarding reduction/cessation in nausea or vomiting (RR 1.40, 95% CI 0.79 to 2.49 and RR 1.51, 95% CI 0.92 to 2.48, respectively; very low-quality evidence).In a study with 92 participants, women taking vitamin B6 had a slightly longer hospital stay compared with placebo (mean difference (MD) 0.80 days, 95% CI 0.08 to 1.52, moderate-quality evidence). There was insufficient evidence to demonstrate a difference in other outcomes including mean number of episodes of emesis (MD 0.50, 95% CI -0.40 to 1.40, low-quality evidence) or side effects.A comparison between metoclopramide and ondansetron identified no clear difference in the severity of nausea or vomiting (MD 1.70, 95% CI -0.15 to 3.55, and MD -0.10, 95% CI -1.63 to 1.43; one study, 83 women, respectively, very low-quality evidence). However, more women taking metoclopramide complained of drowsiness and dry mouth (RR 2.40, 95% CI 1.23 to 4.69, and RR 2.38, 95% CI 1.10 to 5.11, respectively; moderate-quality evidence). There were no clear differences between groups for other side effects.In a single study with 146 participants comparing metoclopramide with promethazine, more women taking promethazine reported drowsiness, dizziness, and dystonia (RR 0.70, 95% CI 0.56 to 0.87, RR 0.48, 95% CI 0.34 to 0.69, and RR 0.31, 95% CI 0.11 to 0.90, respectively, moderate-quality evidence). There were no clear differences between groups for other important outcomes including quality of life and other side effects.In a single trial with 30 women, those receiving ondansetron had no difference in duration of hospital admission compared to those receiving promethazine (MD 0.00, 95% CI -1.39 to 1.39, very low-quality evidence), although there was increased sedation with promethazine (RR 0.06, 95% CI 0.00 to 0.94, low-quality evidence) .Regarding corticosteroids, in a study with 110 participants there was no difference in days of hospital admission compared to placebo (MD -0.30, 95% CI -0.70 to 0.10; very low-quality evidence), but there was a decreased readmission rate (RR 0.69, 95% CI 0.50 to 0.94; four studies, 269 women). For other important outcomes including pregnancy complications, spontaneous abortion, stillbirth and congenital abnormalities, there was insufficient evidence to identify differences between groups (very low-quality evidence for all outcomes). In other single studies there were no clear differences between groups for preterm birth or side effects (very low-quality evidence).For hydrocortisone compared with metoclopramide, no data were available for primary outcomes and there was no difference in the readmission rate (RR 0.08, 95% CI 0.00 to 1.28;one study, 40 women).In a study with 80 women, compared to promethazine, those receiving prednisolone had increased nausea at 48 hours (RR 2.00, 95% CI 1.08 to 3.72; low-quality evidence), but not at 17 days (RR 0.81, 95% CI 0.58 to 1.15, very low-quality evidence). There was no clear difference in the number of episodes of emesis or subjective improvement in nausea/vomiting. There was insufficient evidence to identify differences between groups for stillbirth and neonatal death and preterm birth. AUTHORS' CONCLUSIONS: On the basis of this review, there is little high-quality and consistent evidence supporting any one intervention, which should be taken into account when making management decisions. There was also very limited reporting on the economic impact of hyperemesis gravidarum and the impact that interventions may have.The limitations in interpreting the results of the included studies highlights the importance of consistency in the definition of hyperemesis gravidarum, the use of validated outcome measures, and the need for larger placebo-controlled trials.


Asunto(s)
Terapia por Acupuntura/métodos , Corticoesteroides/uso terapéutico , Antieméticos/uso terapéutico , Hiperemesis Gravídica/terapia , Corticoesteroides/efectos adversos , Antieméticos/efectos adversos , Femenino , Humanos , Hidrocortisona/uso terapéutico , Metoclopramida/efectos adversos , Metoclopramida/uso terapéutico , Ondansetrón/efectos adversos , Ondansetrón/uso terapéutico , Efecto Placebo , Prednisolona/efectos adversos , Prednisolona/uso terapéutico , Embarazo , Prometazina/uso terapéutico , Piridoxina/efectos adversos , Piridoxina/uso terapéutico
10.
Cochrane Database Syst Rev ; (6): CD003101, 2014 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-24941907

RESUMEN

BACKGROUND: Prostaglandins have been used for induction of labour since the 1960s. This is one of a series of reviews evaluating methods of induction of labour. This review focuses on prostaglandins given per vaginam, evaluating these in comparison with placebo (or expectant management) and with each other; prostaglandins (PGE2 and PGF2a); different formulations (gels, tablets, pessaries) and doses. OBJECTIVES: To determine the effects of vaginal prostaglandins E2 and F2a for third trimester cervical ripening or induction of labour in comparison with placebo/no treatment or other vaginal prostaglandins (except misoprostol). SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (1 March 2014) and bibliographies of relevant papers. SELECTION CRITERIA: Clinical trials comparing vaginal prostaglandins used for third trimester cervical ripening or labour induction with placebo/no treatment, with each other, or other methods listed above it on a predefined list of labour induction methods. DATA COLLECTION AND ANALYSIS: We assessed studies and extracted data independently. MAIN RESULTS: Seventy randomised controlled trials (RCTs) (11,487 women) are included. In this update seven new RCTs (778 women) have been added. Two of these new trials compare PGE2 with no treatment, four compare different PGE2 formulations (gels versus tablets, or sustained release pessaries) and one trial compares PGF2a with placebo. The majority of trials were at unclear risk of bias for most domains.Overall, vaginal prostaglandin E2 compared with placebo or no treatment probably reduces the likelihood of vaginal delivery not being achieved within 24 hours. The risk of uterine hyperstimulation with fetal heart rate changes is increased (4.8% versus 1.0%, risk ratio (RR) 3.16, 95% confidence interval (CI) 1.67 to 5.98, 15 trials, 1359 women). The caesarean section rate is probably reduced by about 10% (13.5% versus 14.8%, RR 0.91, 95% CI 0.81 to 1.02, 36 trials, 6599 women). The overall effect on improving maternal and fetal outcomes (across a variety of measures) is uncertain.PGE2 tablets, gels and pessaries (including sustained release preparations) appear to be as effective as each other, small differences are detected between some outcomes, but these maybe due to chance. AUTHORS' CONCLUSIONS: Prostaglandins PGE2 probably increase the chance of vaginal delivery in 24 hours, they increase uterine hyperstimulation with fetal heart changes but do not effect or may reduce caesarean section rates. They increase the likelihood of cervical change, with no increase in operative delivery rates. PGE2 tablets, gels and pessaries appear to be as effective as each other, any differences between formulations are marginal but may be important.


Asunto(s)
Dinoprost/administración & dosificación , Dinoprostona/administración & dosificación , Trabajo de Parto Inducido/métodos , Oxitócicos/administración & dosificación , Administración Intravaginal , Femenino , Humanos , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto , Nacimiento a Término
11.
Longit Life Course Stud ; 15(3): 286-321, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38954421

RESUMEN

In the United Kingdom, the COVID-19 pandemic in 2020 and 2021 led to two extended periods of school closures. Research on inequality of learning opportunity as a result of these closures used a single indicator of socio-economic status, neglecting important determinants of remote learning. Using data from the Understanding Society (USoc) COVID-19 surveys we analysed the levels and differentials in the uptake of remote schoolwork using parental social class, information technology (IT) availability in the home and parental working patterns to capture the distinct resources that families needed to complete remote schoolwork. This is also the first study to assess the extent to which the differentials between socio-economic groups changed between the first and second school-closure periods caused by the pandemic. We found that each of the three factors showed an independent association with the volume of remote schoolwork and that their effect was magnified by their combination. Children in families where the main parent was in an upper-class occupation, where both parents worked from home and where the children had their own IT spent more time doing remote schoolwork than other groups, particularly compared to children of single parents who work from home, children in families where the main parent was in a working-class occupation, where the child had to share IT, and where the parents did not work regularly from home. The differentials between socio-economic groups in the uptake of schoolwork were found to be stable between the two school-closure periods.


Asunto(s)
COVID-19 , Instituciones Académicas , Factores Socioeconómicos , Humanos , COVID-19/epidemiología , Reino Unido/epidemiología , Niño , Masculino , Femenino , Adolescente , SARS-CoV-2 , Padres , Clase Social , Educación a Distancia , Encuestas y Cuestionarios , Pandemias , Teletrabajo
12.
Front Immunol ; 15: 1372079, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919625

RESUMEN

Background: Hip fractures in frail patients result in excess mortality not accounted for by age or comorbidities. The mechanisms behind the high risk of mortality remain undetermined but are hypothesized to be related to the inflammatory status of frail patients. Methods: In a prospective observational exploratory cohort study of hospitalized frail hip fracture patients, 92 inflammatory markers were tested in pre-operative serum samples and markers were tested against 6-month survival post-hip fracture surgery and incidence of acute kidney injury (AKI). After correcting for multiple testing, adjustments for comorbidities and demographics were performed on the statistically significant markers. Results: Of the 92 markers tested, circulating levels of fibroblast growth factor 23 (FGF-23) and interleukin-15 receptor alpha (IL15RA), both involved in renal disease, were significantly correlated with 6-month mortality (27.5% overall) after correcting for multiple testing. The incidence of postoperative AKI (25.4%) was strongly associated with 6-month mortality, odds ratio = 10.57; 95% CI [2.76-40.51], and with both markers plus estimated glomerular filtration rate (eGFR)- cystatin C (CYSC) but not eGFR-CRE. The effect of these markers on mortality was significantly mediated by their effect on postoperative AKI. Conclusion: High postoperative mortality in frail hip fracture patients is highly correlated with preoperative biomarkers of renal function in this pilot study. The effect of preoperative circulating levels of FGF-23, IL15RA, and eGFR-CYSC on 6-month mortality is in part mediated by their effect on postoperative AKI. Creatinine-derived preoperative renal function measures were very poorly correlated with postoperative outcomes in this group.


Asunto(s)
Lesión Renal Aguda , Biomarcadores , Factor-23 de Crecimiento de Fibroblastos , Fracturas de Cadera , Humanos , Fracturas de Cadera/cirugía , Fracturas de Cadera/mortalidad , Fracturas de Cadera/sangre , Masculino , Femenino , Biomarcadores/sangre , Anciano , Anciano de 80 o más Años , Lesión Renal Aguda/mortalidad , Lesión Renal Aguda/etiología , Lesión Renal Aguda/sangre , Lesión Renal Aguda/diagnóstico , Estudios Prospectivos , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/etiología , Factores de Crecimiento de Fibroblastos/sangre , Tasa de Filtración Glomerular , Inflamación/sangre , Periodo Preoperatorio
13.
Cochrane Database Syst Rev ; (7): CD003099, 2013 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-23881775

RESUMEN

BACKGROUND: Castor oil, a potent cathartic, is derived from the bean of the castor plant. Anecdotal reports, which date back to ancient Egypt have suggested the use of castor oil to stimulate labour. Castor oil has been widely used as a traditional method of initiating labour in midwifery practice. Its role in the initiation of labour is poorly understood and data examining its efficacy within a clinical trial are limited. This is one of a series of reviews of methods of cervical ripening and labour induction using standardised methodology. OBJECTIVES: To determine the effects of castor oil or enemas for third trimester cervical ripening or induction of labour in comparison with other methods of cervical ripening or induction of labour. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 April 2013) and bibliographies of relevant papers. SELECTION CRITERIA: Clinical trials comparing castor oil, bath or enemas used for third trimester cervical ripening or labour induction with placebo/no treatment or other methods listed above it on a predefined list of labour induction methods. DATA COLLECTION AND ANALYSIS: A strategy was developed to deal with the large volume and complexity of trial data relating to labour induction. This involved a two-stage method of data extraction. MAIN RESULTS: Three trials, involving 233 women, are included. There was no evidence of differences in caesarean section rates between the two interventions in the two trials reporting this outcome (risk ratio (RR) 2.04, 95% confidence interval (CI) 0.92 to 4.55). There were no data presented on neonatal or maternal mortality or morbidity.There was no evidence of a difference between castor oil and placebo/no treatment for the rate of instrumental delivery, meconium-stained liquor, or Apgar score less than seven at five minutes. The number of participants was too small to detect all but large differences in outcome. All women who ingested castor oil felt nauseous (RR 59.92, 95% CI 8.46 to 424.52). AUTHORS' CONCLUSIONS: The three trials included in the review contain small numbers of women. All three studies used single doses of castor oil. The results from these studies should be interpreted with caution due to the risk of bias introduced due to poor methodological quality. Further research is needed to attempt to quantify the efficacy of castor oil as an cervical priming and induction agent.


Asunto(s)
Aceite de Ricino , Maduración Cervical , Enema , Trabajo de Parto Inducido/métodos , Oxitócicos , Aceite de Ricino/administración & dosificación , Aceite de Ricino/efectos adversos , Cesárea/estadística & datos numéricos , Femenino , Humanos , Oxitócicos/administración & dosificación , Oxitócicos/efectos adversos , Embarazo , Tercer Trimestre del Embarazo , Prostaglandinas , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
Cochrane Database Syst Rev ; (11): CD007372, 2013 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-24222365

RESUMEN

BACKGROUND: More than 20% of women undergo induction of labour in some countries. The different methods used to induce labour have been the focus of previous reviews, but the setting in which induction takes place (hospital versus outpatient settings) may have implications for maternal satisfaction and costs. It is not known whether some methods of induction that are effective and safe in hospital are suitable in outpatient settings. OBJECTIVES: To assess the effects on outcomes for mothers and babies of induction of labour for women managed as outpatients versus inpatients. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 June 2013). SELECTION CRITERIA: Published and unpublished randomised and quasi-randomised trials in which inpatient and outpatient methods of cervical ripening or induction of labour have been compared. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial reports for inclusion. Two review authors carried out data extraction and assessment of risk of bias independently. MAIN RESULTS: We included four trials, with a combined total of 1439 women in the review; each trial examined a different method of induction and we were unable to pool the results from trials.1. Vaginal PGE2 (two studies including 1028 women). There were no differences between women managed as outpatients versus inpatients for most review outcomes. There was no evidence of a difference between the likelihood of women requiring instrumental delivery in either setting (risk ratio (RR) 1.29; 95% confidence interval (CI) 0.79 to 2.13). The overall length of hospital stay was similar in the two groups.2. Controlled release PGE2 10 mg (one study including 300 women). There was no evidence of differences between groups for most review outcomes, including success of induction. During the induction period itself, women in the outpatient group were more likely to report high levels of satisfaction with their care (satisfaction rated seven or more on a nine-point scale, RR 1.42; 95% CI 1.11 to 1.81), but satisfaction scores measured postnatally were similar in the two groups.3. Foley catheter (one study including 111 women). There was no evidence of differences between groups for caesarean section rates, total induction time and the numbers of babies admitted to neonatal intensive care. AUTHORS' CONCLUSIONS: The data available to evaluate the efficacy or potential hazards of outpatient induction are limited. It is, therefore, not yet possible to determine whether induction of labour is effective and safe in outpatient settings.


Asunto(s)
Atención Ambulatoria/métodos , Maduración Cervical , Hospitalización , Trabajo de Parto Inducido/métodos , Cateterismo , Cesárea/estadística & datos numéricos , Dinoprostona , Femenino , Humanos , Recién Nacido , Tiempo de Internación , Oxitócicos , Satisfacción del Paciente , Embarazo , Resultado del Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto
15.
Comput Struct Biotechnol J ; 21: 5326-5336, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37954149

RESUMEN

The gut microbiome is a significant contributor to mental health, with growing evidence linking its composition to anxiety and depressive disorders. Gut microbiome composition is associated with signs of anxiety and depression both in clinically diagnosed mood disorders and subclinically in the general population and may be influenced by dietary fibre intake and the presence of chronic pain. We provide an update of current evidence on the role of gut microbiome composition in depressive and anxiety disorders or symptoms by reviewing available studies. Analysing data from three independent cohorts (osteoarthritis 1 (OA1); n = 46, osteoarthritis 2 (OA2); n = 58, and healthy controls (CON); n = 67), we identified microbial composition signatures of anxiety and depressive symptoms at genus level and cross-validated our findings performing meta-analyses of our results with results from previously published studies. The genera Bifidobacterium (fixed-effect beta (95% CI) = -0.22 (-0.34, -0.10), p = 3.90e-04) and Lachnospiraceae NK4A136 group (fixed-effect beta (95% CI) = -0.09 (-0.13, -0.05), p = 2.53e-06) were found to be the best predictors of anxiety and depressive symptoms, respectively, across our three cohorts and published literature taking into account demographic and lifestyle covariates, such as fibre intake. The association with anxiety was robust in accounting for heterogeneity between cohorts and supports previous observations of the potential prophylactic effect of Bifidobacterium against anxiety symptoms.

16.
Opt Express ; 20(3): 3268-74, 2012 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-22330565

RESUMEN

Optical self seeding feedback techniques can be used to improve the noise characteristics of passively mode-locked laser diodes. External cavities such as fiber optic cables can increase the memory of the phase and subsequently improve the timing jitter. In this work, an improved optical feedback architecture is proposed using an optical fiber loop delay as a cavity extension of the mode-locked laser. We investigate the effect of the noise reduction as a function of the loop length and feedback power. The well known composite cavity technique is also implemented for suppressing supermode noise artifacts presented due to harmonic mode locking effects. Using this method, we achieve a record low radio frequency linewidth of 192 Hz for any high frequency (>1 GHz) passively mode-locked laser to date (to the best of the authors' knowledge), making it promising for the development of high frequency optoelectronic oscillators.


Asunto(s)
Amplificadores Electrónicos , Electrónica/instrumentación , Láseres de Semiconductores , Oscilometría/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Retroalimentación
17.
Opt Lett ; 37(3): 344-6, 2012 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-22297347

RESUMEN

High output power 40 GHz 1.55 µm passively mode-locked surface-etched distributed Bragg reflector (DBR) lasers with monolithically integrated semiconductor optical amplifiers are reported. These are based on an optimized AlGaInAs/InP epitaxial structure with a three quantum well active layer and an optical trap layer. The device produces near transform limited Gaussian pulses with a pulse duration of 3.3 ps. An average output power during mode-locked operation of 130 mW was achieved with a corresponding peak power of >1 W.

18.
Cochrane Database Syst Rev ; (3): CD001233, 2012 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-22419277

RESUMEN

BACKGROUND: Mechanical methods were the first methods developed to ripen the cervix and induce labour. During recent decades they have been substituted by pharmacological methods. Potential advantages of mechanical methods, compared with pharmacological methods, may include simplicity of preservation, lower cost and reduction of the side effects. OBJECTIVES: To determine the effects of mechanical methods for third trimester cervical ripening or induction of labour in comparison with placebo/no treatment, prostaglandins (vaginal and intracervical prostaglandin E2 (PGE2), misoprostol) and oxytocin. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 April 2011) and bibliographies of relevant papers. We updated this search on 16 January 2012 and added the results to the awaiting classification section of the review. SELECTION CRITERIA: Clinical trials comparing mechanical methods used for third trimester cervical ripening or labour induction with methods listed above it on a predefined list of methods of labour. A comparison with amniotomy will be added, should this comparison be made in future trials.Different types of intervention have been considered as mechanical methods: (1) introduction of laminaria tents, or their synthetic equivalent (Dilapan), into the cervical canal; (2) the introduction of a catheter through the cervix into the extra-amniotic space, with or without traction; (3) use of a catheter to inject fluidsin the extra-amniotic spaceIn addition, we made other comparisons: (1) specific mechanical methods (balloon catheter and laminaria tents) compared with any prostaglandins or with oxytocin; (2) addition of prostaglandins or oxytocin to mechanical methods compared with prostaglandins alone. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and assessed risk of bias. Two review authors independently extracted data. MAIN RESULTS: For this update we have included a further 27 studies. The review includes 71 randomised controlled trials (total of 9722 women), ranging from 39 to 588 women per study. Most studies reported on caesarean section, all other outcomes are based on substantially fewer women. Four additional studies are ongoing.Mechanical methods versus no treatment: one study (48 woman) reported on women who did not achieve vaginal delivery within 24 hours (risk ratio (RR) 0.90; 95% confidence interval (CI) 0.64 to 1.26). The risk of caesarean section was similar between groups (six studies; 416 women, RR 1.00; 95% CI 0.76 to 1.30). There were no cases of severe neonatal and maternal morbidity.Mechanical methods versus vaginal PGE2 (17 studies;1894 woman): The proportion of women who did not achieve vaginal delivery within 24 hours was not significantly different (three studies; 586 women RR 1.72; 95% CI 0.90 to 3.27); however, for the subgroup of multiparous women the risk of not achieving delivery within 24 hours was higher (one study; 147 women RR 4.38, 95% CI 1.74 to 10.98), with no increase in caesarean sections (RR 1.19, 95% CI 0.62-2.29). Compared with intracervical PGE2 (14 studies;1784 women and misoprostol there was no significant difference in the proportion of women not achieving vaginal delivery within 24 hours.Mechanical methods reduced the risk of hyperstimulation with fetal heart rate changes when compared with vaginal prostaglandins: vaginal PGE2 (eight studies; 1203 women, RR 0.16; 95% CI 0.06 to 0.39) and misoprostol (3% versus 9%) (nine studies; 1615 women, RR 0.37; 95% CI 0.25 to 0.54). Risk of caesarean section between mechanical methods and prostaglandins was comparable. Serious neonatal and maternal morbidity were infrequently reported and did not differ between the groups.Mechanical methods compared with induction with oxytocin (reduced the risk of caesarean section (five studies; 398 women, RR 0.62; 95% CI 0.42 to 0.90). The likelihood of vaginal delivery within 24 hours was not reported. Hyperstimulation with fetal heart rate changes was reported in one study (200 participants), and did not differ. There were no reported cases of severe maternal or neonatal morbidity. AUTHORS' CONCLUSIONS: Induction of labour using mechanical methods results in similar caesarean section rates as prostaglandins, for a lower risk of hyperstimulation. Mechanical methods do not increase the overall number of women not delivered within 24 hours, however the proportion of multiparous women who did not achieve vaginal delivery within 24 hours was higher when compared with vaginal PGE2. Compared with oxytocin, mechanical methods reduce the risk of caesarean section.


Asunto(s)
Cateterismo/métodos , Maduración Cervical , Trabajo de Parto Inducido/métodos , Laminaria , Oxitócicos , Cuello del Útero , Dinoprostona , Femenino , Humanos , Misoprostol , Oxitocina , Pesarios , Polímeros , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto
19.
Eur J Pain ; 26(3): 740-753, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34958702

RESUMEN

BACKGROUND: Neuropathic pain symptoms and signs of increased pain sensitization in osteoarthritis (OA) patients may explain persistent pain after total joint replacement (TJR). Therefore, identifying genetic markers associated with pain sensitization and neuropathic-like pain phenotypes could be clinically important in identifying targets for early intervention. METHODS: We performed a genome-wide gene-based association study (GWGAS) using pressure pain detection thresholds (PPTs) from distal pain-free sites (anterior tibia), a measure of distal sensitization, and from proximal pain-affected sites (lateral joint line), a measure of local sensitization, in 320 knee OA participants from the Knee Pain and related health in the Community (KPIC) cohort. We next performed gene-based fixed-effects meta-analysis of PPTs and a neuropathic-like pain phenotype using genome-wide association study (GWAS) data from KPIC and from an independent cohort of 613 post-TJR participants, respectively. RESULTS: The most significant genes associated with distal and local sensitization were OR5B3 and BRDT, respectively. We also found previously identified neuropathic pain-associated genes-KCNA1, MTOR, ADORA1 and SCN3B-associated with PPT at the anterior tibia and an inflammatory pain gene-PTAFR-associated with PPT at the lateral joint line. Meta-analysis results of anterior tibia and neuropathic-like pain phenotypes revealed genes associated with bone morphogenesis, neuro-inflammation, obesity, type 2 diabetes, cardiovascular disease and cognitive function. CONCLUSIONS: Overall, our results suggest that different biological processes might be involved in distal and local sensitization, and common genetic mechanisms might be implicated in distal sensitization and neuropathic-like pain. Future studies are needed to replicate these findings. SIGNIFICANCE: To the best of our knowledge, this is the first GWAS for pain sensitization and the first gene-based meta-analysis of pain sensitization and neuropathic-like pain. Higher pain sensitization and neuropathic pain symptoms are associated with persistent pain after surgery hence, identifying genetic biomarkers and molecular pathways associated with these traits is clinically relevant.


Asunto(s)
Diabetes Mellitus Tipo 2 , Neuralgia , Osteoartritis de la Rodilla , Diabetes Mellitus Tipo 2/complicaciones , Estudio de Asociación del Genoma Completo , Humanos , Articulación de la Rodilla , Umbral del Dolor
20.
Opt Express ; 19(10): 9737-43, 2011 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-21643230

RESUMEN

We measured the absorption recovery times in reverse biased AlInGaAs multiple quantum well material designed to emit at around 1.5 µm wavelength. Absorption recovery times as low as 2.5 ps were found at -4V bias, with values below 5 ps consistently found for biases above 3 V. The short absorption recovery times obtained under reverse bias were confirmed by using cross-absorption modulation in the material to demonstrate wavelength conversion of a 10 GHz pulse train, showing both up and down conversion of the incident pulses.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA