Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Eng Sci Med Diagn Ther ; 4(2): 021007, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35832635

RESUMEN

Piezoelectric tube actuators with cantilevered optical fibers have enabled the miniaturization of scanning image acquisition techniques for endoscopic implementation. To achieve raster scanning for such a miniaturized system, the first resonant frequency should be of the order of 10 s of Hz. We explore adding a mass at an intermediate location along the length of the fiber to alter the resonant frequencies of the system. We provide a mathematical model to predict resonant frequencies for a cantilevered beam with an intermediate mass. The theoretical and measured data match well for various fiber lengths, mass sizes, and mass attachment locations along the fiber.

2.
J Biomed Opt ; 26(7)2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34216135

RESUMEN

SIGNIFICANCE: Most cases of high-grade serous ovarian carcinoma originate as serous tubal intraepithelial carcinoma (STIC) lesions in the fallopian tube epithelium (FTE), enabling early endoscopic detection. AIM: The cell-acquiring fallopian endoscope (CAFE) was built to meet requirements for locating potentially pathological tissue indicated by an alteration in autofluorescence or presence of a targeted fluorophore. A channel was included for directed scrape biopsy of cells from regions of interest. APPROACH: Imaging resolution and fluorescence sensitivity were measured using a standard resolution target and fluorescence standards, respectively. A prototype was tested in ex vivo tissue, and collected cells were counted and processed. RESULTS: Measured imaging resolution was 88 µm at a 5-mm distance, and full field of view was ∼45 deg in air. Reflectance and fluorescence images in ex vivo porcine reproductive tracts were captured, and fit through human tracts was verified. Hemocytometry counts showed that on the order of 105 cells per scrape biopsy could be collected from ex vivo porcine tissue. CONCLUSIONS: All requirements for viewing STIC in the FTE were met, and collected cell counts exceeded input requirements for relevant analyses. Our benchtop findings suggest the potential utility of the CAFE device for in vivo imaging and cell collection in future clinical trials.


Asunto(s)
Carcinoma in Situ , Neoplasias Ováricas , Animales , Endoscopios , Trompas Uterinas/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Imagen Óptica , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA