Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Ophthalmol ; 22(1): 292, 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35788211

RESUMEN

BACKGROUND: In the present study, we evaluated the correlation between meibomian gland dropout and meibum quality in the same central 8 meibomian glands of the eyelid. METHODS: Ninety-nine eyes of 91 patients with dry eye were included in the study. Dropout of the 8 central meibomian glands of the eyelids was graded as 0, 1, 2, or 3, according to the dropout area. The meibum quality was graded as follows: grade 0, no secretion; 1, inspissated/toothpaste consistency; 2, cloudy liquid secretion; and 3, clear liquid secretion. For 68 eyes of 68 patients, correlation analysis between dropout and meibum quality was performed. To precisely analyze the direct correlation between meibomian gland dropout in meibography and meibum quality, we evaluated 31 eyes of 23 patients with focal dropout in meibography. RESULTS: The median (interquartile range) meiboscore was 1.0 (2.0) in the upper eyelids and 0.0 (1.0) in the lower eyelids. The median (interquartile range) meibum quality grade was 3.0 (1.0) in the upper eyelids and 1.0 (1.0) in the lower eyelids. No significant correlation between the meiboscore and meibum quality grade was detected in the upper (p =0.746) or lower (p =0.551) eyelids. Analysis of the direct correlation between meibomian gland dropout in meibography and meibum quality in patients with focal dropout (loss of 1 or 2 adjacent meibomian glands), however, indicated that meibomian glands with dropout secreted little to no meibum. CONCLUSIONS: Overall analysis revealed no relationship between meibomian gland dropout and meibum quality, but more detailed investigation of each meibomian gland alone revealed that meibomian glands with dropout secrete little to no meibum.


Asunto(s)
Síndromes de Ojo Seco , Glándulas Tarsales , Síndromes de Ojo Seco/diagnóstico , Humanos , Glándulas Tarsales/diagnóstico por imagen , Examen Físico , Lágrimas
2.
BMC Ophthalmol ; 21(1): 203, 2021 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-33964915

RESUMEN

BACKGROUND: The aim of this study is to analyze and compare the clinical results of toric intraocular lens (IOL) and monofocal IOL implantation when the target refraction value is -3 diopter (D) in cataract patients with corneal astigmatism > 1.5 diopters (D). METHODS: We performed a retrospective chart review for patients with corneal astigmatism > 1.5D who underwent cataract surgery and their target refraction is -3D. 100 eyes (100 patients; monofocal IOL, 60; toric IOL, 40) were enrolled in the current study. Near and distant uncorrected visual acuity (UCVA), corrected VA, spherical equivalent and refractive, corneal astigmatism were evaluated before and after surgery. RESULTS: The near UCVA of the toric IOL group (0.26 ± 0.33) after cataract surgery was significantly better than that of the monofocal IOL group (0.48 ± 0.32) (p = 0.030). The distant UCVA of the toric IOL group (0.38 ± 0.14) was also significantly better than that of the monofocal IOL group (0.55 ± 0.22) (p = 0.026). Best-corrected visual acuity (p = 0.710) and mean spherical equivalent (p = 0.465) did not show significant differences between the toric IOL group and the monofocal IOL group. In the toric IOL group, postoperative refractive astigmatism was - 0.80 ± 0.46D and postoperative corneal astigmatism was - 1.50 ± 0.62D, whereas the corresponding values in the monofocal IOL group were - 1.65 ± 0.77D and - 1.45 ± 0.64D; residual refractive astigmatism was significantly lower with toric IOL implantation compared with monofocal IOL implantation (p = 0.001). There were no postoperative complications. CONCLUSIONS: When myopic refraction such as -3D was determined as the target power in patients with corneal astigmatism, toric IOL implantation led to excellent improvement in both near and distant UCVA.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Miopía , Facoemulsificación , Astigmatismo/cirugía , Humanos , Implantación de Lentes Intraoculares , Miopía/cirugía , Refracción Ocular , Estudios Retrospectivos
3.
BMC Ophthalmol ; 21(1): 444, 2021 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-34961511

RESUMEN

BACKGROUND: A polarization-directed flat (PDF) lens acts as a converging lens with a focal length (f) > 0 and a diverging lens with f < 0, depending on the polarization state of the incidental light. To produce a multifocal lens with two focal lengths, a PDF and a converging lens having shorter focal length were combined. In this study, we tested a bifocal PDF to determine its potential as a new multifocal intraocular lens (IOL). METHODS: Constructed a multifocal lens with a PDF lens (f = +/- 100 mm) and a converging lens (f = + 25 mm). In an optical bench test, we measured the defocus curve to test the multifocal function. The multifocal function and optical quality of the lens in various situations were tested. An Early Treatment Diabetic Retinopathy Study (ETDRS) chart as a near target and a building as a distant target were photographed using a digital single-lens reflex (DSLR) camera. Both lenses (multifocal and monofocal) were tested under the same conditions. RESULTS: For the 0 D and - 20 D focal points, the multifocal lens showed sharp images in the optical bench test. In the DSLR test using the multifocal lens, the building appeared slightly blurry compared with the results using the monofocal lens. With the multifocal lens, the ETDRS chart's images became blurry as the ETDRS chart's distance decreased, but became very clear again at a certain position. CONCLUSIONS: We confirmed the multifocal function of the multifocal lens using a PDF lens. This lens can be used as a multifocal IOL in the future.


Asunto(s)
Lentes Intraoculares , Lentes Intraoculares Multifocales , Facoemulsificación , Sensibilidad de Contraste , Humanos , Refracción Ocular , Visión Ocular
4.
BMC Ophthalmol ; 20(1): 180, 2020 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-32375711

RESUMEN

BACKGROUND: To show how the world appear to patients with multifocal intraocular lens (IOL) using a novel mobile model eye. METHODS: The mobile model eye was composed of an artificial cornea, IOL, IOL chamber, and a camera. A monofocal IOL (Tecnis monofocal IOL) and two diffractive multifocal IOL (ReSTOR, Tecnis multifocal IOL) were used in the study. We went outside to take a picture of the scenery. At night, we stood on a road and took pictures to see how the traffic lights and headlights of cars looked. For an indoor analysis, we approached the Early Treatment Diabetic Retinopathy Study (ETDRS) chart to the model eye from a distance of 95 cm to check the multifocal function of the lenses. In the car, we took pictures of the street and a cell phone in turn to check the multifocal function of the lenses. RESULTS: Two multifocal IOLs showed definite multifocal function. Far objects appeared either similarly clear or slightly hazier (depending on the IOL model) than those with the monofocal IOL. In the night vision, there was a mild or severe halo around light sources compared to those with the monofocal IOL. CONCLUSION: We believe that this mobile model eye can be used to evaluate how the real world appear to a patient with a multifocal IOL, to explain multifocal function of the IOLs, and possible complications in the patients, before performing a surgery.


Asunto(s)
Modelos Teóricos , Lentes Intraoculares Multifocales , Facoemulsificación/métodos , Refracción Ocular/fisiología , Agudeza Visual , Humanos , Diseño de Prótesis
5.
BMC Ophthalmol ; 20(1): 98, 2020 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-32169054

RESUMEN

BACKGROUND: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. METHODS: Thirty-one eyes of 31 patients who underwent cataract surgery with toric intraocular lens implantation were included. All patients had corneal opacity with astigmatism. Preoperative total corneal astigmatism was determined considering posterior astigmatism using a rotating Scheimpflug camera (Pentacam®: Oculus, Wetzlar, Germany). At 2 months after toric intraocular lens implantation, we evaluated residual astigmatism, uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA). RESULTS: Postoperative UCVA and BCVA (0.30 ± 0.17, 0.22 ± 0.16LogMAR) were statistically improved compared to preoperative UCVA and BCVA (1.2 ± 0.34, 1.1 ± 0.30LogMAR, respectively) (P < 0.01). Postoperative residual refractive astigmatism (1.2 ± 0.35D) was statistically reduced compared to preoperative refractive astigmatism (2.4 ± 0.65D) (P < 0.05). Preoperative and postoperative total corneal astigmatism values were not statistically different. All eyes achieved postoperative visual acuity as good as or better than preoperative one. The size of corneal opacity covering pupil had significant negative correlation with postoperative UCVA and BCVA (logMAR) (R = 0.91 P < 0.05 and R = 0.92 P < 0.05, respectively). CONCLUSION: Toric intraocular lens implantation can improve UCVA, BCVA, and refractive astigmatism in cataract patient with corneal opacity. The size of corneal opacity covering pupil is the major prognostic factor for postoperative visual improvement. Therefore, toric intraocular lens implantation should be considered for cataract patients who have corneal opacity with high astigmatism.


Asunto(s)
Catarata/complicaciones , Opacidad de la Córnea/cirugía , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Facoemulsificación/métodos , Refracción Ocular/fisiología , Opacidad de la Córnea/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
6.
BMC Ophthalmol ; 20(1): 438, 2020 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-33148200

RESUMEN

BACKGROUND: The tear film breakup time (tBUT) is a clinical evaluation of evaporative dry eye disease assessed by instilling topical fluorescein into the eyes. In the present study, we introduce a new diagnostic test, blinking tolerance time (BTT), for self-evaluation of tear-film stability. We compared the results with the tBUT and validated the BTT test for self-assessment of tear film instability. METHODS: This was a prospective controlled study involving 212 eyes of 106 participants 20-79 years of age. A total of 114 eyes of 57 dry eye patients and 98 eyes of 49 healthy subjects were included in the study. All patients and subjects were administered the following tests to diagnose dry eye disease: Ocular Surface Disease Index, BTT, tBUT, slit-lamp examination, corneal stain score, and Schirmer I test (without anesthesia). Patients and subjects were instructed not to blink for as long possible after reset blinking. The time interval between the reset blink and the next blink was measured. The mean of 3 tBUT values in both the right and left eyes was defined as tBUTBE. Correlations between the BTT and tBUTBE were also evaluated. To evaluate the diagnostic efficacy of the BTT and tBUT tests, receiver operating characteristic (ROC) curves were generated to obtain a cutoff score, and the sensitivities of the tests against the specificity at all possible thresholds were plotted. RESULTS: Spearman's correlation analysis revealed a significant weakly positive correlation between BTT and tBUTBE (r = 0.447; p = 0.000). The intraclass correlation coefficient (ICC) of the tBUT was 0.679 (95% confidence interval [CI]: 0.575-0.765) and the ICC of the BTT was 0.904 (95% CI: 0.867-0.932). The area under the ROC curve did not significantly differ between the tBUTBE (0.678) and BTT (0.628, p = 0.641). When the cutoff value of the BTT test was set to 8.1 s, the sensitivity was 63.3% and the specificity was 56.1%. CONCLUSION: The BTT test is a simple, inexpensive, and effective method for self-diagnosing dry eye that can also be used in the clinical setting.


Asunto(s)
Parpadeo , Síndromes de Ojo Seco , Síndromes de Ojo Seco/diagnóstico , Fluoresceína , Humanos , Estudios Prospectivos , Lágrimas
8.
BMC Ophthalmol ; 19(1): 169, 2019 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-31376834

RESUMEN

BACKGROUND: Accurate alignment of toric intraocular lens (TIOL) to steep corneal astigmatic axis is important to achieve effective postoperative results. The authors compare the accuracy of astigmatism correction using automated and manual marking in TIOL implantation during cataract surgery. METHODS: One hundred thirty-two eyes with nuclear density from Grade 2 to 4 were randomly subdivided into 2 groups (automated and manual marking). All patients underwent manual marking and the steep axis was compared to SensoMotoric Instruments (SMI). After phacoemulsification, 62 patients underwent toric IOL implantation using the SMI and 70 patients underwent toric IOL implantation using manual marking. Intraoperative measurement was the steep axis difference. Clinical measurements included preoperative and postoperative best corrected visual acuity (BCVA), and TIOL axis. RESULTS: The intraoperative steep axis difference between SMI and manual marking was 7.86 ± 6.4 degrees. The difference between the preoperative steep axis and the postoperative TIOL axis using SMI (3.63 ± 1.12 degrees) was significantly lower than that using manual marking (8.29 ± 2.23 degrees) (P < 0.05). CONCLUSIONS: The steep axis measurements may be different when using SMI vs. manual marking. The SMI is more accurate than manual marking for TIOL implantation during cataract surgery. TRIAL REGISTRATION: Current Controlled Trials ISRCTN12294725 , Retrospectively registered, on 20 July 2018.


Asunto(s)
Automatización/métodos , Catarata/fisiopatología , Lentes Intraoculares , Cuidados Preoperatorios/métodos , Refracción Ocular/fisiología , Agudeza Visual , Biometría/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis
9.
BMC Ophthalmol ; 19(1): 53, 2019 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-30777066

RESUMEN

BACKGROUND: To demonstrate that the Corvis ST could be used to quantify the biomechanical parameters of the orbital soft tissues by measuring and comparing whole eye movement (WEM) using the Corvis in normal eyes and in eyes of patients with Graves ophthalmopathy. METHODS: Forty four eyes of 44 ophthalmologically normal subjects and 28 eyes of 28 patients with Graves ophthalmopathy were included in the study. After Corvis test, the examiners recorded WEM by air puff. In the patients with Graves ophthalmopathy, the partial correlation coefficient adjusted for age and gender was calculated to analyze the correlation between exopthalmometry and WEM. Same analysis was repeated for the correlation between and the cross sectional area (%) of the extraocular muscles in the orbit CT and WEM. RESULTS: WEM was 0.314 ± 0.083 mm in the normal subjects and 0.227 ± 0.079 mm in the Graves ophthalmopathy group (p = 0.000). The exophthalmometry was not significantly correlated with WEM after adjusting for age and gender (R = 0.083, p = 0.688). In the 21 Graves ophthalmopathy patients examined by orbit CT, after adjusting for age and gender, WEM significantly decreased as the cross sectional area (%) of the extraocular muscles in the orbit increased (R = - 0.461, p = 0.047). CONCLUSIONS: WEM by Corvis could be used to quantify the biomechanical parameters of the orbital soft tissue. However, it is unclear whether WEM effectively represents the orbital biomechanical parameters, because WEM is only 0.6% of the orbital depth.


Asunto(s)
Córnea/fisiología , Técnicas de Diagnóstico Oftalmológico/instrumentación , Movimientos Oculares/fisiología , Oftalmopatía de Graves/fisiopatología , Músculos Oculomotores/fisiología , Órbita/fisiología , Adulto , Anciano , Fenómenos Biomecánicos , Femenino , Voluntarios Sanos , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
10.
BMC Ophthalmol ; 19(1): 131, 2019 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-31208393

RESUMEN

BACKGROUND: This study is aim to compare the clinical effectiveness between the two most prominent dry eye disease (DED)-specific eye drops, 0.05% cyclosporine (CN) and 3% diquafosol (DQ). METHODS: This is a multi-centered, randomized, masked, prospective clinical study. A total of 153 DED patients were randomly allocated to use CN twice per day or DQ six times daily. Cornea and conjunctival staining scores (NEI scale), tear break-up time (TBUT), Schirmer test scores, and ocular surface disease index (OSDI) score were measured at baseline, 4 and 12 weeks after treatment. RESULTS: At 12 weeks after treatment, NEI scaled scores were significantly reduced from the baseline by - 6.60 for CN and - 6.63 for DQ group (all P < 0.0001, P = 0.9739 between groups). TBUT and Schirmer values for CN were significantly improved from the baseline at 4 and 12 weeks (P = 0.0034, P < 0.0001 for TBUT, P = 0.0418, P = 0.0031 for Schirmer test). However, for DQ, TBUT showed significant improvement at 12 weeks only (P = 0.0281). Mean OSDI score differences from the baseline to 12 weeks were improved by - 13.03 ± 19.63 for CN and - 16.11 ± 20.87 for DQ, respectively (all P < 0.0001, P = 0.854 between groups). Regarding drug compliance, the mean instillation frequency of CN was less than that of DQ (P < 0.001). There were no statistically significant intergroup differences in safety evaluation. CONCLUSIONS: The level of improvement regarding NEI, TBUT, and OSDI scores were not significantly different between the two treatment groups. However, with regards to the early improvement of TBUT and patient compliance, patients using CN improved faster and with greater adherence to drug usage than did those treated with DQ. TRIAL REGISTRATION: KCT0002180 , retrospectively registered on 23 December 2016.


Asunto(s)
Ciclosporina/uso terapéutico , Síndromes de Ojo Seco/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Soluciones Oftálmicas/uso terapéutico , Polifosfatos/uso terapéutico , Nucleótidos de Uracilo/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Conjuntiva/patología , Femenino , Humanos , Gotas Lubricantes para Ojos/uso terapéutico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Lágrimas/fisiología , Adulto Joven
11.
Biotechnol Bioeng ; 114(4): 903-914, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27775170

RESUMEN

The in vitro generation of cell-based three dimensional (3D) nerve tissue is an attractive subject to improve graft survival and integration into host tissue for neural tissue regeneration or to model biological events in stem cell differentiation. Although 3D organotypic culture strategies are well established for 3D nerve tissue formation of pluripotent stem cells to study underlying biology in nerve development, cell-based nerve tissues have not been developed using human postnatal stem cells with therapeutic potential. Here, we established a culture strategy for the generation of in vitro cell-based 3D nerve tissue from postnatal stem cells from apical papilla (SCAPs) of teeth, which originate from neural crest-derived ectomesenchyme cells. A stem cell population capable of differentiating into neural cell lineages was generated during the ex vivo expansion of SCAPs in the presence of EGF and bFGF, and SCAPs differentiated into neural cells, showing neural cell lineage-related molecular and gene expression profiles, morphological changes and electrophysical property under neural-inductive culture conditions. Moreover, we showed the first evidence that 3D cell-based nerve-like tissue with axons and myelin structures could be generated from SCAPs via 3D organotypic culture using an integrated bioprocess composed of polyethylene glycol (PEG) microwell-mediated cell spheroid formation and subsequent dynamic culture in a high aspect ratio vessel (HARV) bioreactor. In conclusion, the culture strategy in our study provides a novel approach to develop in vitro engineered nerve tissue using SCAPs and a foundation to study biological events in the neural differentiation of postnatal stem cells. Biotechnol. Bioeng. 2017;114: 903-914. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Reactores Biológicos , Papila Dental/citología , Tejido Nervioso/citología , Células Madre/citología , Células Madre/fisiología , Ingeniería de Tejidos/métodos , Adolescente , Diferenciación Celular , Niño , Humanos , Diente Molar/citología , Esferoides Celulares/citología
12.
Exp Eye Res ; 127: 20-5, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24952277

RESUMEN

The present study evaluated survival effects of N-acetylcysteine (NAC) on cultured corneal endothelial cells exposed to oxidative and endoplasmic reticulum (ER) stress and in a mouse model of early-onset Fuchs endothelial corneal dystrophy (FECD). Cultured bovine corneal endothelial cell viability against oxidative and ER stress was determined by CellTiter-Glo(®) luminescent reagent. Two-month-old homozygous knock-in Col8a2(L450W/L450W) mutant (L450W) and C57/Bl6 wild-type (WT) animals were divided into two groups of 15 mice. Group I received 7 mg/mL NAC in drinking water and Group II received control water for 7 months. Endothelial cell density and morphology were evaluated with confocal microscopy. Antioxidant gene (iNos) and ER stress/unfolded protein response gene (Grp78 and Chop) mRNA levels and protein expression were measured in corneal endothelium by real time PCR and Western blotting. Cell viability of H2O2 and thapsigargin exposed cells pre-treated with NAC was significantly increased compared to untreated controls (p < 0.01). Corneal endothelial cell density (CD) was higher (p = 0.001) and percent polymegathism was lower (p = 0.04) in NAC treated L450W mice than in untreated L450W mice. NAC treated L450W endothelium showed significant upregulation of iNos, whereas Grp78 and Chop were downregulated compared to untreated L450W endothelium by real time PCR and Western blotting. NAC increases survival in cultured corneal endothelial cells exposed against ER and oxidative stress. Systemic NAC ingestion increases corneal endothelial cell survival which is associated with increased antioxidant and decreased ER stress markers in a mouse model of early-onset FECD. Our study presents in vivo evidence of a novel potential medical treatment for FECD.


Asunto(s)
Acetilcisteína/farmacología , Modelos Animales de Enfermedad , Endotelio Corneal/efectos de los fármacos , Depuradores de Radicales Libres/farmacología , Distrofia Endotelial de Fuchs/prevención & control , Animales , Western Blotting , Recuento de Células , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Chaperón BiP del Retículo Endoplásmico , Endotelio Corneal/metabolismo , Endotelio Corneal/patología , Distrofia Endotelial de Fuchs/metabolismo , Distrofia Endotelial de Fuchs/patología , Proteínas de Choque Térmico/genética , Peróxido de Hidrógeno/toxicidad , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Microscopía Confocal , Óxido Nítrico Sintasa de Tipo II/metabolismo , Estrés Oxidativo , Reacción en Cadena de la Polimerasa , ARN Mensajero/metabolismo , Tapsigargina/toxicidad , Factor de Transcripción CHOP/genética
13.
Can J Ophthalmol ; 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38889881

RESUMEN

OBJECTIVE: To evaluate the relationship between change of effective lens position (ELP) and toric intraocular lens (IOL) rotation in patients with increasing postoperative refractive astigmatism after successful toric IOL implantation. METHODS: The subjects include 61 people (61 eyes) with increasing residual astigmatism >0.5 D 3 months after successful toric IOL implantation. Clinical measurements included preoperative, 1-week, and 1-, 2-, and 3-month postoperative visual acuity; refraction; keratometer; anterior and posterior corneal astigmatism; ELP by Scheimpflug camera imaging; and IOL axis by slit-lamp biomicroscopic photograph with pupil dilation. RESULTS: Residual astigmatism in postoperative month 3 (0.81 ± 0.50 D) is higher than that at postoperative week 1 (0.41 ± 0.38 D; p < 0.05). ELP decreased by 264.44 ± 163.25 µm, and the IOL rotated by 2.91 ± 1.44 degrees from week 1 to month 3 (p < 0.05). The ELP change had a positive correlation with IOL rotation (R2 = 0.383; p = 0.006), and the postoperative refractive astigmatic change had a positive correlation with ELP change (R2 = 0.272; p = 0.027) and IOL rotation (R2 = 0.272; p = 0.0001) from week 1 to month 3. CONCLUSION: ELP change can influence toric IOL rotation and increase residual astigmatism after toric IOL implantation.

14.
Cornea ; 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38251908

RESUMEN

PURPOSE: The purpose of this study was to describe a new surgical technique for deep anterior lamellar keratoplasty. METHODS: All pupils in the recipient eyes were dilated preoperatively. Vertical grooving was performed using a crescent blade with a width of 5 mm and a depth of one-third to half corneal thickness on the temporal side of the limbus. Stromal dissection was performed as close as possible to Descemet membrane by observing the gap between the gold line by retinal reflex and the front edge of the crescent blade. Lamellar dissection was performed along the lamellar plane using corneal dissectors. The ophthalmic viscoelastic device was injected into the intrastromal pocket to separate the anterior and posterior stroma and an anterior corneal lamella was excised. A donor cornea was sutured into the recipient bed. RESULTS: In 18 eyes, none of the patients had Descemet membrane rupture during surgery. The mean postoperative residual stromal thickness was 80 ± 31 µm. The mean central corneal thickness after surgery was 660 ± 69 µm. At the last follow-up, the cornea was cleared in all 18 eyes on slit-lamp examination. CONCLUSIONS: We estimated the residual stromal thickness based on the gap between the gold line by the retinal reflex and crescent blade, and intrastromal lamellar dissection was performed using a smooth corneal dissector. Consequently, the surface of stromal dissection was smooth, and the residual stromal thickness was even.

15.
Korean J Ophthalmol ; 38(3): 227-235, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38665113

RESUMEN

PURPOSE: In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findings. METHODS: The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan. RESULTS: In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 µm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva. CONCLUSIONS: Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.


Asunto(s)
Aparato Lagrimal , Microscopía Acústica , Humanos , Microscopía Acústica/métodos , Aparato Lagrimal/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Adulto , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/diagnóstico por imagen , Anciano , Síndrome de Sjögren/diagnóstico por imagen , Síndrome de Sjögren/diagnóstico
16.
Korean J Ophthalmol ; 38(1): 64-70, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38148689

RESUMEN

PURPOSE: In the present study, we determined the prevalence of obstructive meibomian gland dysfunction (MGD), hyposecretory MGD, grossly normal MG, and hypersecretory MGD in patients with dry eye syndrome using lipid layer thickness (LLT) and MG dropout. METHODS: Eighty-eight patients with dry eye syndrome were included in the study. Patients were categorized into four groups according to the LLT and weighted total meiboscore. The proportion of patients in each group was calculated. The age, sex, Ocular Surface Disease Index, LLT, Schirmer, tear film breakup time, cornea stain, weighted total meiboscore, expressibility, and quality of meibum were compared between the four groups. RESULTS: Fifteen eyes (17.0%) had obstructive MGD, two eyes (2.3%) had hyposecretory MGD, 40 eyes (45.5%) had grossly normal MG, and 17 eyes (19.3%) had hypersecretory MGD. The obstructive MGD group was younger than the grossly normal MG group. In obstructive MGD, the ratio of men to women was higher than that of the other groups. However, Ocular Surface Disease Index, Schirmer, tear film breakup time, and corneal stain did not show statistically significant differences between the four groups. The meibum expressibility of the hyposecretoy MGD group was worse than those of the other groups. The meibum expressibility of the hyposecretoy MGD group was poor than those of the obstructive and hypersecretory MGD group. CONCLUSIONS: This categorization was expected to help determine the best treatment method for dry eye syndrome, according to the MG status.


Asunto(s)
Síndromes de Ojo Seco , Disfunción de la Glándula de Meibomio , Masculino , Humanos , Femenino , Disfunción de la Glándula de Meibomio/diagnóstico , Glándulas Tarsales/diagnóstico por imagen , Estudios Retrospectivos , Síndromes de Ojo Seco/diagnóstico , Lágrimas , Lípidos
17.
Plant Physiol ; 158(4): 1955-64, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22232383

RESUMEN

Sucrose-nonfermentation1-related protein kinase1 (SnRK1) is an evolutionarily conserved energy sensor protein that regulates gene expression in response to energy depletion in plants. Efforts to elucidate the functions and mechanisms of this protein kinase are hampered, however, by inherent growth defects of snrk1-null mutant plants. To overcome these limitations and study SnRK1 functions in vivo, we applied a method combining transient expression in leaf mesophyll protoplasts and stable expression in transgenic plants. We found that both rice (Oryza sativa) and Arabidopsis (Arabidopsis thaliana) SnRK1 activities critically influence stress-inducible gene expression and the induction of stress tolerance. Genetic, molecular, and chromatin immunoprecipitation analyses further revealed that the nuclear SnRK1 modulated target gene transcription in a submergence-dependent manner. From early seedling development through late senescence, SnRK1 activities appeared to modulate developmental processes in the plants. Our findings offer insight into the regulatory functions of plant SnRK1 in stress-responsive gene regulation and in plant growth and development throughout the life cycle.


Asunto(s)
Arabidopsis/enzimología , Arabidopsis/genética , Regulación de la Expresión Génica de las Plantas , Oryza/enzimología , Oryza/crecimiento & desarrollo , Proteínas Serina-Treonina Quinasas/metabolismo , Estrés Fisiológico/genética , Arabidopsis/efectos de los fármacos , Proteínas de Arabidopsis/metabolismo , Núcleo Celular/efectos de los fármacos , Núcleo Celular/enzimología , Núcleo Celular/genética , Inundaciones , Regulación del Desarrollo de la Expresión Génica/efectos de los fármacos , Regulación de la Expresión Génica de las Plantas/efectos de los fármacos , Oryza/efectos de los fármacos , Oxígeno/farmacología , Hojas de la Planta/efectos de los fármacos , Hojas de la Planta/enzimología , Hojas de la Planta/crecimiento & desarrollo , Unión Proteica/efectos de los fármacos , Unión Proteica/genética , Transporte de Proteínas/efectos de los fármacos , Plantones/efectos de los fármacos , Plantones/genética , Plantones/crecimiento & desarrollo , Estrés Fisiológico/efectos de los fármacos
18.
Clin Exp Ophthalmol ; 41(7): 694-701, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23433183

RESUMEN

BACKGROUND: To evaluate the effects of bevacizumab eye drops on corneal epithelial wound healing and the stromal response after epithelial injury in rats. METHODS: We divided 160 Sprague-Dawley male rats into two groups and de-epithelized corneas with a microblade. Five percent bevacizumab (Avastin) and antibiotic (Cravit) eyedrops were treated four times daily in the bevacizumab group and antibiotic eye drops only in the control group. Wound area evaluation, enzyme-linked immunosorbent assay, immunofluorescent staining, and real-time polymerase chain reaction were performed with rat corneas. RESULTS: The percentage of wound healing in the bevacizumab group was lower than in the control group at 24, 48 and 72 hours after epithelial debridement (P = 0.02, 0.01 and 0.01). Corneal matrix metalloproteinase-2 (P = 0.02, 0.01 and 0.02), matrix metalloproteinase-9 (P = 0.03, 0.01 and 0.01) and transforming growth factor-ß (P = 0.02, 0.02 and 0.01) proteins in the bevacizumab group were higher than control group at 24, 48, and 72 hours. Matrix metalloproteinase-2, matrix metalloproteinase-9, transforming growth factor-b and a-smooth muscle actin were strongly stained in the bevacizumab corneas compared with control corneas in immunofluorescent staining. Matrix metalloproteinase-2 (P = 0.04, 0.03 and 0.04), matrix metalloproteinase- 9 (P = 0.03, 0.01 and 0.02), transforming growth factor-b (P = 0.03, 0.03 and 0.03) and a-smooth muscle actin (P = 0.04, 0.01 and 0.04) messenger RNA levels in the bevacizumab group were also highly expressed compared with the control group at 24, 48, and 72 hours. CONCLUSIONS: The bevacizumab eye drops delay the wound healing and increase stromal response after corneal epithelial injury in rats.


Asunto(s)
Inhibidores de la Angiogénesis/uso terapéutico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Sustancia Propia/efectos de los fármacos , Epitelio Corneal/lesiones , Lesiones Oculares/tratamiento farmacológico , Cicatrización de Heridas/efectos de los fármacos , Heridas no Penetrantes/tratamiento farmacológico , Actinas/genética , Actinas/metabolismo , Animales , Bevacizumab , Sustancia Propia/metabolismo , Desbridamiento , Ensayo de Inmunoadsorción Enzimática , Epitelio Corneal/metabolismo , Lesiones Oculares/metabolismo , Técnica del Anticuerpo Fluorescente Indirecta , Masculino , Metaloproteinasa 2 de la Matriz/genética , Metaloproteinasa 2 de la Matriz/metabolismo , Metaloproteinasa 9 de la Matriz/genética , Metaloproteinasa 9 de la Matriz/metabolismo , Soluciones Oftálmicas , ARN Mensajero/metabolismo , Ratas , Ratas Sprague-Dawley , Reacción en Cadena en Tiempo Real de la Polimerasa , Factor de Crecimiento Transformador beta/genética , Factor de Crecimiento Transformador beta/metabolismo , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Heridas no Penetrantes/metabolismo
19.
Ann Med ; 55(1): 2228192, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37354028

RESUMEN

PURPOSE: We sought to evaluate the expression of matrix metalloproteinase-9 (MMP-9) in dry eyes treated with 0.05% cyclosporin A and 3.0% diquafosol tetrasodium. METHODS: One-hundred ninety-five eyes of 195 patients with dry eye were divided into three groups as follows: group 1, cyclosporin group (n = 69); group 2, diquafosol group (n = 59); and group 3, artificial tears eyes (n = 67). All eyes were treated and followed up for three months. Schirmer I Test, corneal staining, tear-film break-up time (TBUT), and tear-film MMP-9 content were measured at three months and compared between groups. The expression of MMP-9 was confirmed using a point-of-care test device (InflammaDry®; RPS Diagnostics, Sarasota, FL, USA) and graded as zero to four points. RESULTS: At the third month, MMP-9 expression was lower in group 1 as compared with in groups 2 and 3 (p = 0.020 and 0.006, respectively). The mean MMP-9 grade according to point-of-care testing was also lower in group 1 than in groups 2 or 3 (p = 0.002 and 0.038, respectively). MMP-9 showed a correlation with corneal staining in both groups 1 and 2 (all p < 0.001) and with Schirmer I Test and TBUT in group 1 (p = 0.018 and 0.015, respectively). CONCLUSIONS: MMP-9 expression and grade were lower after treatment with cyclosporin than after treatment with diquafosol in the dry eye disease. Anti-inflammatory treatment can decrease ocular MMP-9 levels in dry eye disease.


MMP-9 expression and grade were lower after treatment with cyclosporin than after treatment with diquafosol in the dry eye disease. Anti-inflammatory treatment can decrease ocular MMP-9 levels in dry eye disease.


Asunto(s)
Ciclosporina , Síndromes de Ojo Seco , Humanos , Ciclosporina/uso terapéutico , Metaloproteinasa 9 de la Matriz , Síndromes de Ojo Seco/tratamiento farmacológico , Nucleótidos de Uracilo/uso terapéutico
20.
Transl Vis Sci Technol ; 12(7): 5, 2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37405796

RESUMEN

Purpose: To use the revised model eye to observe and compare how the world is perceived by patients with monofocal intraocular lens (IOL), Eyhance, bifocal IOL, and Symfony, and check its performance. Methods: The new mobile model eye consists of an artificial cornea, an IOL, a wet cell, an adjustable lens tube, a lens tube, an objective lens, a tube lens, and a digital single-lens reflex camera. We collected photographs of distant buildings and streets at night, videos of the focusing process, and videos of United States Air Force resolution target from 6 m to 15 cm and analyzed them quantitatively. Results: In this revised model eye using an objective lens, an artificial cornea similar to the human cornea could be used. Using a digital single-lens reflex camera, high-resolution imaging was possible without an additional computer. Fine focusing was possible using an adjustable lens tube. For monofocal IOL, the contrast modulation was 0.39 at 6 m and decreased consistently. It was nearly 0 as the model eye got closer than 1.6 m. For Eyhance, the contrast modulation was 0.40 at 6 m. It then decreased and increased again. At 1.3 m, it was 0.07 and then decreased again. For Symfony, the contrast modulation was 0.18 at 6 m. Symfony showed the characteristics of a bifocal IOL with low add diopter. Halos (234 pixels) were observed around lights, although smaller than those seen with bifocal IOL (432 pixels). Conclusions: We could objectively observe and compare how patients with monofocal IOL, Eyhance, bifocal IOL, and Symfony perceived the world using this revised model eye. Translational Relevance: Data obtained by this new mobile model eye can be used to help patients select their IOLs before cataract surgeries.


Asunto(s)
Lentes Intraoculares , Humanos , Agudeza Visual , Visión Ocular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA