RESUMEN
BACKGROUND: Dry eye syndrome has been recently reported in patients who underwent whole brain radiotherapy (WBRT). WBRT based on a couch with three-degrees of freedom (3D) can occasionally be performed in which the rotational head motion is not corrected. This study assessed the dependency of the rotational errors on the mask and the dose variation of the lens and lacrimal gland in WBRT patients. METHODS: Translational and rotational setup errors were obtained at the first treatment with cone-beam CT (CBCT) for patients under WBRT and frameless stereotactic radiosurgery (SRS) (n = 20 each) immobilized using a conventional WB mask and an SRS mask with a bite block, respectively. For the CT sets of SRS cases, WBRT plans were generated for the study. To simulate the rotational error, rotated CT images were created with each rotational error, on which initial WBRT plans were copied and doses were recalculated. The lens and lacrimal gland doses with and without rotation errors were compared. RESULTS: Despite similar translational setup errors for the two masks, the SRS mask showed a dramatic reduction in rotational errors compared to those of the WB mask. The errors varied within -2.9° to 2.9° and -1.2° to 0.7° for the WB and SRS masks, respectively. Accordingly, the SRS mask confined the change in the maximum lens dose, mean dose of the lacrimal gland, and lacrimal volume receiving 15 Gy to one-third of those using the WB mask. CONCLUSION: When the six-degrees of freedom (6D) couch is not available, the frameless SRS mask is beneficial to WBRT for the faithful treatment as it was planned.
Asunto(s)
Neoplasias Encefálicas , Aparato Lagrimal , Radiocirugia , Humanos , Errores de Configuración en Radioterapia , Rotación , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Encéfalo , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirugía , Tomografía Computarizada de Haz Cónico/métodosRESUMEN
BACKGROUND/AIM: To investigate the association between the thyroid dysfunction and thyroid radiation dose in regional nodal irradiation (RNI) using volumetric modulated arc therapy (VMAT) for breast cancer. PATIENTS AND METHODS: We reviewed medical data of 67 patients with breast cancer who underwent curative surgery followed by adjuvant radiotherapy, including RNI using VMAT, between 2018 and 2021. All patients had normal thyroid functional test results, including thyroid stimulating hormone (TSH), T3, and free-T4. We defined subclinical hypothyroidism as increased TSH with or without decreased levels of free-T4 and T3 after the completion of VMAT. We calculated dose-volume histogram parameters (DVHPs), including the mean dose and relative thyroid volume receiving at least 10, 20, 30, and 40 Gy. RESULTS: The median follow-up time was 23.2 months. The 3-year locoregional failure-free survival, progression-free survival, and overall survival rates were 96.3%, 94.7%, and 96.2%, respectively. The mean thyroid dose was 21.4 Gy (range=11.5-29.4 Gy). Subclinical hypothyroidism was noted in 14 patients (20.9%) and the median time to the event was 4.1 months. Among the DVHPs, the relative volume receiving ≥20 Gy (V20Gy) was associated with subclinical hypothyroidism. The 2-year rates of subclinical hypothyroidism were 24.8% and 59.1% in patients with V20Gy ≤46.3% and >46.3%, respectively. CONCLUSION: A significant proportion of patients with breast cancer developed subclinical hypothyroidism after undergoing VMAT for RNI. Our findings highlight the importance of considering the thyroid as an organ at risk for VMAT planning, and suggest that V20Gy could be a useful dose-volume constraint.
Asunto(s)
Neoplasias de la Mama , Hipotiroidismo , Radioterapia de Intensidad Modulada , Humanos , Femenino , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Dosis de Radiación , Hipotiroidismo/etiología , TirotropinaRESUMEN
BACKGROUND/AIM: To evaluate the early effect of radiation dose on liver function in breast cancer patients undergoing free-breathing volumetric modulated arc therapy (FB-VMAT). PATIENTS AND METHODS: Medical records of 125 patients with breast cancer who underwent curative surgery followed by postoperative radiotherapy using FB-VMAT during 2018-2021 were reviewed. Results of the liver function test (LFT), performed within 1-week before and 6-months after radiotherapy, were collected and compared. The LFTs analyzed albumin, total and direct bilirubin, aspartate transaminase, alanine transferase, and alkaline phosphatase levels. The mean dose and relative liver volume receiving at least 10 Gy, 20 Gy, or 30 Gy were calculated. RESULTS: Median follow-up time was 21.4 months. One patient experienced locoregional and distant failures. The mean liver irradiation dose was 325.9 centigray (cGy) for all patients. The liver irradiation dose was higher in patients with right breast cancer than in those with left breast cancer (mean, 434.1 cGy vs. 260.6 cGy, p<0.001). Direct bilirubin and aspartate transaminase levels showed significant differences after FB-VMAT. LFT results outside normal limits were noted in 31 patients at follow-up, but nobody met the criteria of radiation-induced liver disease. Underlying liver disease, breast laterality, systemic treatment, or dose-volume histogram parameters were not associated with abnormal LFT results. CONCLUSION: FB-VMAT can deliver radiation doses safely without adversely affecting the liver. The mean dose ≤4 Gy could be a useful dose criterium of the liver for FB-VMAT plans.