Resultados 1 - 13 de 13
Filtrar
1.
Neurosurg Focus ; 49(1): E6, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32610297

RESUMEN

The development of closed-loop deep brain stimulation (DBS) systems represents a significant opportunity for innovation in the clinical application of neurostimulation therapies. Despite the highly dynamic nature of neurological diseases, open-loop DBS applications are incapable of modifying parameters in real time to react to fluctuations in disease states. Thus, current practice for the designation of stimulation parameters, such as duration, amplitude, and pulse frequency, is an algorithmic process. Ideal stimulation parameters are highly individualized and must reflect both the specific disease presentation and the unique pathophysiology presented by the individual. Stimulation parameters currently require a lengthy trial-and-error process to achieve the maximal therapeutic effect and can only be modified during clinical visits. The major impediment to the development of automated, adaptive closed-loop systems involves the selection of highly specific disease-related biomarkers to provide feedback for the stimulation platform. This review explores the disease relevance of neurochemical and electrophysiological biomarkers for the development of closed-loop neurostimulation technologies. Electrophysiological biomarkers, such as local field potentials, have been used to monitor disease states. Real-time measurement of neurochemical substances may be similarly useful for disease characterization. Thus, the introduction of measurable neurochemical analytes has significantly expanded biomarker options for feedback-sensitive neuromodulation systems. The potential use of biomarker monitoring to advance neurostimulation approaches for treatment of Parkinson's disease, essential tremor, epilepsy, Tourette syndrome, obsessive-compulsive disorder, chronic pain, and depression is examined. Further, challenges and advances in the development of closed-loop neurostimulation technology are reviewed, as well as opportunities for next-generation closed-loop platforms.


Asunto(s)
Encéfalo/fisiopatología , Estimulación Encefálica Profunda , Enfermedades del Sistema Nervioso/terapia , Trastorno Obsesivo Compulsivo/terapia , Estimulación Encefálica Profunda/métodos , Temblor Esencial/terapia , Humanos , Enfermedad de Parkinson/terapia , Síndrome de Tourette/fisiopatología
2.
Analyst ; 137(6): 1428-35, 2012 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-22299131

RESUMEN

Although fast-scan cyclic voltammetry (FSCV) has contributed to important advances in neuroscience research, the technique is encumbered by significant analytical challenges. Confounding factors such as pH change and transient effects at the microelectrode surface make it difficult to discern the analytes represented by complex voltammograms. Here we introduce paired-pulse voltammetry (PPV), that mitigates the confounding factors and simplifies the analytical task. PPV consists of a selected binary waveform with a specific time gap between each of its two comprising pulses, such that each binary wave is repeated, while holding the electrode at a negative potential between the waves. This allows two simultaneous yet very different voltammograms (primary and secondary) to be obtained, each corresponding to the two pulses in the binary waveform. PPV was evaluated in the flow cell to characterize three different analytes, (dopamine, adenosine, and pH changes). The peak oxidation current decreased by approximately 50%, 80%, and 4% for dopamine, adenosine, and pH, in the secondary voltammogram compared with the primary voltammogram, respectively. Thus, the influence of pH changes could be virtually eliminated using the difference between the primary and secondary voltammograms in the PPV technique, which discriminates analytes on the basis of their adsorption characteristics to the carbon fiber electrode. These results demonstrate that PPV can be effectively used for differentiating complex analytes.


Asunto(s)
Adenosina/análisis , Dopamina/análisis , Técnicas Electroquímicas/métodos , Animales , Química Encefálica , Electrodos , Concentración de Iones de Hidrógeno , Masculino , Oxidación-Reducción , Ratas , Ratas Sprague-Dawley
3.
IEEE Int Symp Med Meas Appl ; 2017: 349-354, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-29202131

RESUMEN

The ability to measure neurotransmitter activity using implanted electrochemical sensors offers researchers a potent technique for analyzing neural activity across specific neural circuitry. We have developed a wirelessly controlled device, WINCS Harmoni, to observe and measure neurotransmitter dynamics at up to four separate sensors, with high temporal and spatial resolution. WINCS Harmoni also incorporates a versatile neurostimulator that can be synchronized with electrochemical recording. The WINCS Harmoni platform is thus optimally suited for probing the neurochemical effects of neurostimulation, and may in turn enable the development of personalized therapies for multiple brain disorders.

4.
Sci Rep ; 7: 46675, 2017 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-28452348

RESUMEN

There has been significant progress in understanding the role of neurotransmitters in normal and pathologic brain function. However, preclinical trials aimed at improving therapeutic interventions do not take advantage of real-time in vivo neurochemical changes in dynamic brain processes such as disease progression and response to pharmacologic, cognitive, behavioral, and neuromodulation therapies. This is due in part to a lack of flexible research tools that allow in vivo measurement of the dynamic changes in brain chemistry. Here, we present a research platform, WINCS Harmoni, which can measure in vivo neurochemical activity simultaneously across multiple anatomical targets to study normal and pathologic brain function. In addition, WINCS Harmoni can provide real-time neurochemical feedback for closed-loop control of neurochemical levels via its synchronized stimulation and neurochemical sensing capabilities. We demonstrate these and other key features of this platform in non-human primate, swine, and rodent models of deep brain stimulation (DBS). Ultimately, systems like the one described here will improve our understanding of the dynamics of brain physiology in the context of neurologic disease and therapeutic interventions, which may lead to the development of precision medicine and personalized therapies for optimal therapeutic efficacy.


Asunto(s)
Técnicas Biosensibles/métodos , Encéfalo/fisiología , Estimulación Encefálica Profunda/métodos , Técnicas Electroquímicas/métodos , Neurotransmisores/metabolismo , Animales , Encéfalo/metabolismo , Encefalopatías/diagnóstico , Encefalopatías/metabolismo , Encefalopatías/fisiopatología , Dopamina/metabolismo , Estimulación Eléctrica , Femenino , Humanos , Macaca mulatta , Masculino , Ratones , Ratas Sprague-Dawley , Porcinos , Telemetría/métodos
5.
J Neurosurg ; 123(1): 232-242, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25479124

RESUMEN

OBJECT: Despite a promising outlook, existing intraspinal microstimulation (ISMS) techniques for restoring functional motor control after spinal cord injury are not yet suitable for use outside a controlled laboratory environment. Thus, successful application of ISMS therapy in humans will require the use of versatile chronic neurostimulation systems. The objective of this study was to establish proof of principle for wireless control of ISMS to evoke controlled motor function in a rodent model of complete spinal cord injury. METHODS: The lumbar spinal cord in each of 17 fully anesthetized Sprague-Dawley rats was stimulated via ISMS electrodes to evoke hindlimb function. Nine subjects underwent complete surgical transection of the spinal cord at the T-4 level 7 days before stimulation. Targeting for both groups (spinalized and control) was performed under visual inspection via dorsal spinal cord landmarks such as the dorsal root entry zone and the dorsal median fissure. Teflon-insulated stimulating platinum-iridium microwire electrodes (50 µm in diameter, with a 30- to 60-µm exposed tip) were implanted within the ventral gray matter to an approximate depth of 1.8 mm. Electrode implantation was performed using a free-hand delivery technique (n = 12) or a Kopf spinal frame system (n = 5) to compare the efficacy of these 2 commonly used targeting techniques. Stimulation was controlled remotely using a wireless neurostimulation control system. Hindlimb movements evoked by stimulation were tracked via kinematic markers placed on the hips, knees, ankles, and paws. Postmortem fixation and staining of the spinal cord tissue were conducted to determine the final positions of the stimulating electrodes within the spinal cord tissue. RESULTS: The results show that wireless ISMS was capable of evoking controlled and sustained activation of ankle, knee, and hip muscles in 90% of the spinalized rats (n = 9) and 100% of the healthy control rats (n = 8). No functional differences between movements evoked by either of the 2 targeting techniques were revealed. However, frame-based targeting required fewer electrode penetrations to evoke target movements. CONCLUSIONS: Clinical restoration of functional movement via ISMS remains a distant goal. However, the technology presented herein represents the first step toward restoring functional independence for individuals with chronic spinal cord injury.


Asunto(s)
Estimulación Eléctrica/métodos , Parálisis/terapia , Traumatismos de la Médula Espinal/terapia , Médula Espinal/fisiopatología , Tecnología Inalámbrica , Animales , Potenciales Evocados Motores/fisiología , Femenino , Microelectrodos , Modelos Animales , Movimiento/fisiología , Músculo Esquelético/inervación , Músculo Esquelético/fisiología , Parálisis/fisiopatología , Ratas , Ratas Sprague-Dawley , Traumatismos de la Médula Espinal/fisiopatología , Resultado del Tratamiento
6.
J Neurosurg ; 119(6): 1556-65, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24116724

RESUMEN

OBJECT: Conventional deep brain stimulation (DBS) devices continue to rely on an open-loop system in which stimulation is independent of functional neural feedback. The authors previously proposed that as the foundation of a DBS "smart" device, a closed-loop system based on neurochemical feedback, may have the potential to improve therapeutic outcomes. Alterations in neurochemical release are thought to be linked to the clinical benefit of DBS, and fast-scan cyclic voltammetry (FSCV) has been shown to be effective for recording these evoked neurochemical changes. However, the combination of FSCV with conventional DBS devices interferes with the recording and identification of the evoked analytes. To integrate neurochemical recording with neurostimulation, the authors developed the Mayo Investigational Neuromodulation Control System (MINCS), a novel, wirelessly controlled stimulation device designed to interface with FSCV performed by their previously described Wireless Instantaneous Neurochemical Concentration Sensing System (WINCS). METHODS: To test the functionality of these integrated devices, various frequencies of electrical stimulation were applied by MINCS to the medial forebrain bundle of the anesthetized rat, and striatal dopamine release was recorded by WINCS. The parameters for FSCV in the present study consisted of a pyramidal voltage waveform applied to the carbon-fiber microelectrode every 100 msec, ramping between -0.4 V and +1.5 V with respect to an Ag/AgCl reference electrode at a scan rate of either 400 V/sec or 1000 V/sec. The carbon-fiber microelectrode was held at the baseline potential of -0.4 V between scans. RESULTS: By using MINCS in conjunction with WINCS coordinated through an optic fiber, the authors interleaved intervals of electrical stimulation with FSCV scans and thus obtained artifact-free wireless FSCV recordings. Electrical stimulation of the medial forebrain bundle in the anesthetized rat by MINCS elicited striatal dopamine release that was time-locked to stimulation and increased progressively with stimulation frequency. CONCLUSIONS: Here, the authors report a series of proof-of-principle tests in the rat brain demonstrating MINCS to be a reliable and flexible stimulation device that, when used in conjunction with WINCS, performs wirelessly controlled stimulation concurrent with artifact-free neurochemical recording. These findings suggest that the integration of neurochemical recording with neurostimulation may be a useful first step toward the development of a closed-loop DBS system for human application.


Asunto(s)
Estimulación Encefálica Profunda/instrumentación , Equipos y Suministros/normas , Retroalimentación Fisiológica/fisiología , Neurotransmisores/fisiología , Animales , Técnicas Biosensibles/normas , Cuerpo Estriado/metabolismo , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/normas , Dopamina/metabolismo , Técnicas Electroquímicas/normas , Diseño de Equipo/normas , Masculino , Haz Prosencefálico Medial/fisiología , Microelectrodos/estadística & datos numéricos , Ratas , Ratas Sprague-Dawley
7.
Mayo Clin Proc ; 87(8): 760-5, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22809886

RESUMEN

Essential tremor is often markedly reduced during deep brain stimulation simply by implanting the stimulating electrode before activating neurostimulation. Referred to as the microthalamotomy effect, the mechanisms of this unexpected consequence are thought to be related to microlesioning targeted brain tissue, that is, a microscopic version of tissue ablation in thalamotomy. An alternate possibility is that implanting the electrode induces immediate neurochemical release. Herein, we report the experiment performing with real-time fast-scan cyclic voltammetry to quantify neurotransmitter concentrations in human subjects with essential tremor during deep brain stimulation. The results show that the microthalamotomy effect is accompanied by local neurochemical changes, including adenosine release.


Asunto(s)
Adenosina/metabolismo , Estimulación Encefálica Profunda , Temblor Esencial/terapia , Anciano , Anciano de 80 o más Años , Encéfalo/patología , Técnicas Electroquímicas , Electroquímica , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Tecnología Inalámbrica
8.
Artículo en Inglés | MEDLINE | ID: mdl-22254400

RESUMEN

Deep brain stimulation (DBS) within the basal ganglia complex is an effective neurosurgical approach for treating symptoms of Parkinson's disease (PD), Essential Tremor, Dystonia, Depression, Obssessive Compulsive Disorder, and Tourette's Syndrome, among others. Elucidating DBS mechanism has become a critical clinical and research goal in stereotactic and functional neurosurgery and in neural engineering. Along with electro-physiological and microdialysis techniques, two additional powerful technologies, notably functional Magnetic Resonance Imaging (fMRI) and in vivo neurochemical monitoring have recently been used to investigate DBS-mediated activation of basal ganglia network circuitry. For this purpose, we have previously developed WINCS (Wireless Instantaneous Neurotransmitter Concentration Sensor System), which is an MRI-compatible wireless monitoring device to obtain chemically resolved neurotransmitter measurements at implanted microsensors in a large mammalian model (pig) as well as in human patients. This device supports an array of electrochemical measurements that includes fast-scan cyclic voltammetry (FSCV) for real-time simultaneous in vivo monitoring of dopamine and adenosine release at carbon-fiber microelectrodes as well as fixed potential amperometry for monitoring of glutamate at enzyme-linked biosensors. In addition, we have utilized fMRI to investigate subthalamic nucleus (STN) DBS activation in the pig with 3Tesla MR scanner. We demonstrate the activation of specific basal ganglia circuitry during STN DBS using both fMRI and FSCV in the pig model. Our results suggest that fMRI and electrochemistry are important emerging techniques for use in elucidating mechanism of action of DBS.


Asunto(s)
Ganglios Basales/fisiopatología , Estimulación Encefálica Profunda/métodos , Imagen por Resonancia Magnética/tendencias , Animales , Humanos
9.
J Neurosurg ; 112(3): 539-48, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19731995

RESUMEN

OBJECT: The authors of previous studies have demonstrated that local adenosine efflux may contribute to the therapeutic mechanism of action of thalamic deep brain stimulation (DBS) for essential tremor. Real-time monitoring of the neurochemical output of DBS-targeted regions may thus advance functional neurosurgical procedures by identifying candidate neurotransmitters and neuromodulators involved in the physiological effects of DBS. This would in turn permit the development of a method of chemically guided placement of DBS electrodes in vivo. Designed in compliance with FDA-recognized standards for medical electrical device safety, the authors report on the utility of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for real-time comonitoring of electrical stimulation-evoked adenosine and dopamine efflux in vivo, utilizing fast-scan cyclic voltammetry (FSCV) at a polyacrylonitrile-based (T-650) carbon fiber microelectrode (CFM). METHODS: The WINCS was used for FSCV, which consisted of a triangle wave scanned between -0.4 and +1.5 V at a rate of 400 V/second and applied at 10 Hz. All voltages applied to the CFM were with respect to an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single T-650 carbon fiber (r = 2.5 microm) into a glass capillary and pulling to a microscopic tip using a pipette puller. The exposed carbon fiber (the sensing region) extended beyond the glass insulation by approximately 50 microm. Proof of principle tests included in vitro measurements of adenosine and dopamine, as well as in vivo measurements in urethane-anesthetized rats by monitoring adenosine and dopamine efflux in the dorsomedial caudate putamen evoked by high-frequency electrical stimulation of the ventral tegmental area and substantia nigra. RESULTS: The WINCS provided reliable, high-fidelity measurements of adenosine efflux. Peak oxidative currents appeared at +1.5 V and at +1.0 V for adenosine, separate from the peak oxidative current at +0.6 V for dopamine. The WINCS detected subsecond adenosine and dopamine efflux in the caudate putamen at an implanted CFM during high-frequency stimulation of the ventral tegmental area and substantia nigra. Both in vitro and in vivo testing demonstrated that WINCS can detect adenosine in the presence of other easily oxidizable neurochemicals such as dopamine comparable to the detection abilities of a conventional hardwired electrochemical system for FSCV. CONCLUSIONS: Altogether, these results demonstrate that WINCS is well suited for wireless monitoring of high-frequency stimulation-evoked changes in brain extracellular concentrations of adenosine. Clinical applications of selective adenosine measurements may prove important to the future development of DBS technology.


Asunto(s)
Adenosina/metabolismo , Encéfalo/metabolismo , Dopamina/metabolismo , Equipos y Suministros Eléctricos , Telemetría/instrumentación , Telemetría/métodos , Resinas Acrílicas , Animales , Estimulación Eléctrica , Electrodos Implantados , Diseño de Equipo , Estudios de Factibilidad , Masculino , Microelectrodos , Oxidación-Reducción , Ratas , Ratas Sprague-Dawley
10.
J Neurosurg ; 113(3): 656-65, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20415521

RESUMEN

OBJECT: The authors previously reported the development of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for measuring dopamine and suggested that this technology may be useful for evaluating deep brain stimulation-related neuromodulatory effects on neurotransmitter systems. The WINCS supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially resolved neurotransmitter measurements. The FSCV parameters used to establish WINCS dopamine measurements are not suitable for serotonin, a neurotransmitter implicated in depression, because they lead to CFM fouling and a loss of sensitivity. Here, the authors incorporate into WINCS a previously described N-shaped waveform applied at a high scan rate to establish wireless serotonin monitoring. METHODS: Optimized for the detection of serotonin, FSCV consisted of an N-shaped waveform scanned linearly from a resting potential of +0.2 to +1.0 V, then to -0.1 V and back to +0.2 V, at a rate of 1000 V/second. Proof-of-principle tests included flow injection analysis and electrically evoked serotonin release in the dorsal raphe nucleus of rat brain slices. RESULTS: Flow cell injection analysis demonstrated that the N waveform, applied at a scan rate of 1000 V/second, significantly reduced serotonin fouling of the CFM, relative to that observed with FSCV parameters for dopamine. In brain slices, WINCS reliably detected subsecond serotonin release in the dorsal raphe nucleus evoked by local high-frequency stimulation. CONCLUSIONS: The authors found that WINCS supported high-fidelity wireless serotonin monitoring by FSCV at a CFM. In the future such measurements of serotonin in large animal models and in humans may help to establish the mechanism of deep brain stimulation for psychiatric disease.


Asunto(s)
Técnicas Electroquímicas/instrumentación , Monitoreo Fisiológico/instrumentación , Neurotransmisores/metabolismo , Núcleos del Rafe/metabolismo , Serotonina/metabolismo , Telemetría/instrumentación , Animales , Calibración , Carbono , Fibra de Carbono , Dopamina/metabolismo , Estimulación Eléctrica , Técnicas Electroquímicas/métodos , Diseño de Equipo , Técnicas In Vitro , Masculino , Microelectrodos , Monitoreo Fisiológico/métodos , Ratas , Ratas Sprague-Dawley , Telemetría/métodos , Factores de Tiempo
11.
J Neurosurg ; 111(4): 712-23, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19425890

RESUMEN

OBJECT: Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. METHODS: The FSCV study consisted of a triangle wave scanned between -0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 mum) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by approximately 100 microm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. RESULTS: The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus-connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. CONCLUSIONS: Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.


Asunto(s)
Encéfalo/metabolismo , Técnicas Electroquímicas/instrumentación , Monitoreo Intraoperatorio/instrumentación , Neurotransmisores/metabolismo , Telemetría/instrumentación , Animales , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Estimulación Encefálica Profunda , Dopamina/metabolismo , Estimulación Eléctrica , Técnicas Electroquímicas/métodos , Masculino , Modelos Animales , Monitoreo Intraoperatorio/métodos , Neurocirugia/instrumentación , Neurocirugia/métodos , Norepinefrina/metabolismo , Ratas , Ratas Sprague-Dawley , Serotonina/metabolismo , Telemetría/métodos
12.
J Neurosurg ; 111(4): 701-11, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19425899

RESUMEN

OBJECT: In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. METHODS: The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme-linked electrode to measure glutamate; and 3) a multiple enzyme-linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. RESULTS: The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. CONCLUSIONS: By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.


Asunto(s)
Adenosina/metabolismo , Encéfalo/metabolismo , Dopamina/metabolismo , Técnicas Electroquímicas/instrumentación , Ácido Glutámico/metabolismo , Monitoreo Intraoperatorio/instrumentación , Neurocirugia/instrumentación , Animales , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Estimulación Encefálica Profunda , Técnicas Electroquímicas/métodos , Femenino , Masculino , Modelos Animales , Monitoreo Intraoperatorio/métodos , Corteza Motora/metabolismo , Neurocirugia/métodos , Ratas , Ratas Sprague-Dawley , Porcinos , Telemetría/instrumentación , Telemetría/métodos , Tálamo/metabolismo
13.
Artículo en Inglés | MEDLINE | ID: mdl-19963865

RESUMEN

The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans - a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Monitoreo Intraoperatorio/instrumentación , Monitoreo Intraoperatorio/métodos , Encéfalo/metabolismo , Dopamina/metabolismo , Humanos , Serotonina/metabolismo , Programas Informáticos