Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Phys Rev Lett ; 124(8): 084802, 2020 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-32167312

RESUMEN

Acceleration of particles from the interaction of ultraintense laser pulses up to 5×10^{21} W cm^{-2} with thin foils is investigated experimentally. The electron beam parameters varied with decreasing spot size, not just laser intensity, resulting in reduced temperatures and divergence. In particular, the temperature saturated due to insufficient acceleration length in the tightly focused spot. These dependencies affected the sheath-accelerated protons, which showed poorer spot-size scaling than widely used scaling laws. It is therefore shown that maximizing laser intensity by using very small foci has reducing returns for some applications.

2.
Opt Express ; 22(2): 2060-9, 2014 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-24515215

RESUMEN

We demonstrate the performance of an efficient insertable pulse cleaning module (IPCM) that uses a saturable absorber (SA) pair with a compensating multi-pass amplifier. IPCM consists of a first SA, a grating compressor, a second SA, a stretcher and a compensating Ti:sapphire amplifier. It is implemented with a conventional chirped pulse amplification (CPA) Ti:sapphire laser system, resulting in a double CPA system architecture, and suppresses the amplified spontaneous emission (ASE) level of the pulse pedestal by about three orders of magnitude while preserving the output pulse energy and repetition-rate of the overall laser system. The duration of recompressed cleaned pulses is comparable to that obtained without the cleaning module. The effectiveness of the cleaning module is confirmed in laser-driven proton acceleration experiments. At the 10(9) W/cm2 pedestal level, the surface structure and electrical resistivity of an insulator target (100 nm silicon nitride) are preserved prior to the arrival of the intense ultrashort pulse.

3.
Phys Rev Lett ; 108(13): 135004, 2012 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-22540709

RESUMEN

We demonstrate a new high-order harmonic generation mechanism reaching the "water window" spectral region in experiments with multiterawatt femtosecond lasers irradiating gas jets. A few hundred harmonic orders are resolved, giving µJ/sr pulses. Harmonics are collectively emitted by an oscillating electron spike formed at the joint of the boundaries of a cavity and bow wave created by a relativistically self-focusing laser in underdense plasma. The spike sharpness and stability are explained by catastrophe theory. The mechanism is corroborated by particle-in-cell simulations.

4.
Sci Rep ; 12(1): 2346, 2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35173182

RESUMEN

Graphene is known as an atomically thin, transparent, highly electrically and thermally conductive, light-weight, and the strongest 2D material. We investigate disruptive application of graphene as a target of laser-driven ion acceleration. We develop large-area suspended graphene (LSG) and by transferring graphene layer by layer we control the thickness with precision down to a single atomic layer. Direct irradiations of the LSG targets generate MeV protons and carbons from sub-relativistic to relativistic laser intensities from low contrast to high contrast conditions without plasma mirror, evidently showing the durability of graphene.

5.
Opt Express ; 19(5): 4560-5, 2011 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-21369288

RESUMEN

Kα line emissions from Mo and Ag plates were experimentally studied using clean, ultrahigh-intensity femtosecond laser pulses. The absolute yields of Kα x-rays at 17 keV from Mo and 22 keV from Ag were measured as a function of the laser pulse contrast ratio and irradiation intensity. Significantly enhanced Kα yields were obtained for both Mo and Ag by employing high contrast ratios and irradiances. Conversion efficiencies of 4.28×10⁻5/sr for Mo and 4.84×10⁻5/sr for Ag, the highest values obtained to date, were demonstrated with contrast ratios in the range 10⁻¹° to 10⁻¹¹.


Asunto(s)
Rayos Láser , Rayos X , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación
6.
Sci Rep ; 11(1): 7338, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33795713

RESUMEN

We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.

7.
Phys Rev Lett ; 103(23): 235003, 2009 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-20366154

RESUMEN

Laser light reflection by a relativistically moving electron density modulation (flying mirror) in a wake wave generated in a plasma by a high intensity laser pulse is investigated experimentally. A counterpropagating laser pulse is reflected and upshifted in frequency with a multiplication factor of 37-66, corresponding to the extreme ultraviolet wavelength. The demonstrated flying mirror reflectivity (from 3 x 10(-6) to 2 x 10(-5), and from 1.3 x 10(-4) to 0.6 x 10(-3), for the photon number and pulse energy, respectively) is close to the theoretical estimate for the parameters of the experiment.

8.
Phys Rev Lett ; 103(19): 194803, 2009 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-20365929

RESUMEN

A high stability electron bunch is generated by laser wakefield acceleration with the help of a colliding laser pulse. The wakefield is generated by a laser pulse; the second laser pulse collides with the first pulse at 180 degrees and at 135 degrees realizing optical injection of an electron bunch. The electron bunch has high stability and high reproducibility compared with single pulse electron generation. In the case of 180 degrees collision, special measures have been taken to prevent damage. In the case of 135 degrees collision, since the second pulse is countercrossing, it cannot damage the laser system.

9.
Rev Sci Instrum ; 88(7): 073304, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28764503

RESUMEN

A high repetition rate scintillator-based transverse beam profile diagnostic for laser-plasma accelerated proton beams has been designed and commissioned. The proton beam profiler uses differential filtering to provide coarse energy resolution and a flexible design to allow optimisation for expected beam energy range and trade-off between spatial and energy resolution depending on the application. A plastic scintillator detector, imaged with a standard 12-bit scientific camera, allows data to be taken at a high repetition rate. An algorithm encompassing the scintillator non-linearity is described to estimate the proton spectrum at different spatial locations.

10.
Sci Rep ; 7(1): 17968, 2017 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-29269841

RESUMEN

Burst Intensification by Singularity Emitting Radiation (BISER) is proposed. Singularities in multi-stream flows of emitting media cause constructive interference of emitted travelling waves, forming extremely localized sources of bright coherent emission. Here we for the first time demonstrate this extreme localization of BISER by direct observation of nano-scale coherent x-ray sources in a laser plasma. The energy emitted into the spectral range from 60 to 100 eV is up to ~100 nJ, corresponding to ~1010 photons. Simulations reveal that these sources emit trains of attosecond x-ray pulses. Our findings establish a new class of bright laboratory sources of electromagnetic radiation. Furthermore, being applicable to travelling waves of any nature (e.g. electromagnetic, gravitational or acoustic), BISER provides a novel framework for creating new emitters and for interpreting observations in many fields of science.

11.
Phys Rev E Stat Nonlin Soft Matter Phys ; 71(1 Pt 2): 015403, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15697651

RESUMEN

We study experimentally the interaction of the shortest at present (23-fs) , relativistically intense (20-TW), tightly focused laser pulses with underdense plasma. MeV electrons constitute a two-temperature distribution due to different plasma wave-breaking processes at a plasma density of 10(20) cm(-3). These two groups of electrons are shown numerically to constitute bunches with very distinctive time durations.

12.
FEBS Lett ; 450(1-2): 95-100, 1999 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-10350064

RESUMEN

A gene named epk2 that encodes the amino acid sequence of a protein kinase was identified from the photosynthetic flagellate, Euglena gracilis Z. Homology search and phylogenetic analysis revealed that the deduced amino acid sequence of epk2 is most similar to that of the catalytic subunit of cAMP-dependent protein kinase (PKA). Northern blot analysis showed that Euglena cells express a 1.4-kb transcript of this gene. When the EPK2 protein was coexpressed with the rat regulatory subunit of PKA in cultured mammalian cells, these two proteins were coimmunoprecipitated. The association of EPK2 and the rat regulatory subunit of PKA was not detected in the cell lysate incubated with cAMP. EPK2 immunoprecipitated from the transfected cells phosphorylated Kemptide, a synthetic peptide substrate for PKA, and the phosphorylation was inhibited by PKI, a PKA-selective protein kinase inhibitor. These results indicate that EPK2 is a PKA homologue in the photosynthetic flagellate, and this is the first evidence for the occurrence of the PKA catalytic subunit in photosynthetic organisms.


Asunto(s)
Proteínas Quinasas Dependientes de AMP Cíclico/genética , Euglena gracilis/enzimología , Secuencia de Aminoácidos , Animales , Secuencia de Bases , Células COS , Clonación Molecular , Proteínas Quinasas Dependientes de AMP Cíclico/química , Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Inhibidores Enzimáticos/farmacología , Datos de Secuencia Molecular , Oligopéptidos/metabolismo , Fosforilación , Fotosíntesis , Filogenia , Pruebas de Precipitina , Proteínas Protozoarias/química , Proteínas Protozoarias/genética , ARN Mensajero/metabolismo , Ratas , Homología de Secuencia de Aminoácido , Transfección
13.
Intern Med ; 33(10): 624-7, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7827380

RESUMEN

A 65-year-old man with an occupational history of asbestos exposure developed dysphagia and vomiting. Clinical examinations at onset revealed a dilated esophagus with smooth narrowing at the gastroesophageal junction and no apparent tumor in and around the esophagus. Achalasia was suspected. Dysphagia progressed gradually and examinations performed three months after the onset disclosed a tumor in the pleural and the peritoneal cavities. At laparotomy, the tumor extended from the pleural cavity into the peritoneal cavity. Histological examination of the biopsied specimen demonstrated malignant mesothelioma. We report the first case of malignant pleural mesothelioma presenting as achalasia.


Asunto(s)
Asbestosis/complicaciones , Acalasia del Esófago/etiología , Mesotelioma/complicaciones , Neoplasias Pleurales/complicaciones , Anciano , Humanos , Masculino , Mesotelioma/diagnóstico , Mesotelioma/etiología , Pleura/patología , Neoplasias Pleurales/diagnóstico , Neoplasias Pleurales/etiología
14.
Rev Sci Instrum ; 85(2): 02A705, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593439

RESUMEN

High intensity laser-plasma interaction has attracted considerable interest for a number of years. The laser-plasma interaction is accompanied by generation of various charged particle beams, such as high-energy proton and ions with high charge to mass ratio (Q/M; same as multi-charged ions). Results of simultaneous novel measurements of electron-induced photonuclear neutrons (photoneutron), which are a diagnostic of the laser-plasma interaction, are proposed to use for optimization of the laser-plasma ion generation. The proposed method is demonstrated by the laser irradiation with the intensity of 1 × 10(21) W/cm(2) on the metal foil target. The photoneutrons are measured by using NE213 liquid scintillation detectors. Heavy-ion signal is registered with the CR-39 track detector simultaneously. The measured signals of the electron-induced photoneutrons are well reproduced by using the Particle and Heavy Ion Transport code System. The results obtained provide useful approach for analyzing the various laser based ion beams.

15.
Rev Sci Instrum ; 85(2): 02B904, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593609

RESUMEN

Experimental demonstration of multi-charged heavy ion acceleration from the interaction between the ultra-intense short pulse laser system and the metal target is presented. Al ions are accelerated up to 12 MeV/u (324 MeV total energy). To our knowledge, this is far the highest energy ever reported for the case of acceleration of the heavy ions produced by the <10 J laser energy of 200 TW class Ti:sapphire laser system. Adding to that, thanks to the extraordinary high intensity laser field of ∼10(21) W cm(-2), the accelerated ions are almost fully stripped, having high charge to mass ratio (Q/M).


Asunto(s)
Aluminio , Iones Pesados , Rayos Láser , Aceleradores de Partículas/instrumentación
16.
Rev Sci Instrum ; 83(5): 053502, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22667617

RESUMEN

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

18.
Am J Physiol ; 263(4 Pt 2): R976-80, 1992 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1415811

RESUMEN

Amounts of colostral proteins in lymph and plasma were estimated by an enzyme-linked immunosorbent assay (ELISA) after infusion of bovine colostrum into the duodenal lumen in nonsuckling neonatal pigs. The rate of immunoglobulin (Ig) G transport in lymph of the thoracic duct reached the maximal level (4.7 +/- 1.3 mg.15 min-1.kg body wt-1) within 3 h after the duodenal infusion. The rate of small protein (SP) transport more slowly increased than that of IgG. On the contrary, casein remained in the much lower level in lymph. IgG concentration in plasma increased gradually and reached a plateau level (2.5 +/- 0.9 g/l) 5 h after the infusion, but the levels of SP and casein were slowly and slightly increased in plasma. The IgG-to-casein and SP-to-casein ratios in lymph and plasma were 161:15:1 and 128:12:1 4 h after the infusion, respectively, and much higher than the value in the colostrum (IgG/SP/casein = 15:4:1). These results indicate 1) that IgG transported via lymph flow after absorption through the small intestine is faster than that via blood flow, 2) that the concentration of absorbed IgG is higher than that of absorbed SP and much higher than the concentration of absorbed casein both in the lymph and plasma, and 3) that total amount of colostral protein transported via blood flow is larger than that transported via lymph flow.


Asunto(s)
Animales Recién Nacidos/metabolismo , Calostro/metabolismo , Inmunoglobulina G/metabolismo , Linfa/metabolismo , Porcinos/metabolismo , Animales , Transporte Biológico , Caseínas/sangre , Bovinos , Duodeno , Ensayo de Inmunoadsorción Enzimática , Inmunoglobulina G/sangre , Inyecciones , Concentración Osmolar , Factores de Tiempo
19.
J Dairy Sci ; 72(2): 398-406, 1989 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-2703564

RESUMEN

Enzyme-linked immunosorbent assay method was improved to monitor the concentrations of colostral proteins in the range of 10 to 10(3) ng/ml in calf serum. Colostral proteins were purified from fat-free colostrum, and antibodies against them were prepared from the rabbit anti-colostrum protein sera. Concentration of each protein was determined by enzyme-linked immunosorbent assay without interference by calf serum proteins in a mixture of colostrum and precolostral calf serum. Changes in the colostral protein concentrations in the sera of five postcolostral calves were monitored by enzyme-linked immunosorbent assay. After feeding colostrum to the neonatal calf, serum IgG concentration increased rapidly within 16 h to 8.1 to 36.8 mg/ml and gradually declined until 3 d to the steady levels, 4.7 to 23.6 mg/ml. The concentrations of casein and P2 (colostral small proteins, which were eluted at the second peak in Sephadex G-100 gel filtration) also increased more rapidly within 16 h to 9.6 to 264.0 micrograms/ml and 31.5 to 1600 micrograms/ml, respectively, and steeply decreased to near the detection limit on 3 d after feeding. These results indicate that enzyme-linked immunosorbent assay is useful to measure and monitor the absorbed colostral proteins and also to survey calves receiving and not receiving colostrum.


Asunto(s)
Bovinos/sangre , Calostro/inmunología , Inmunoglobulina G/análisis , Animales , Ensayo de Inmunoadsorción Enzimática , Femenino , Embarazo
20.
Artículo en Inglés | MEDLINE | ID: mdl-2461832

RESUMEN

1. The secretory responses of bile and exocrine pancreas were studied in various aged piglets. 2. At 3 days old the bile and exocrine pancreas could be reacted by various stimulations. The response by secretin was the same as that in the 28 day old. 3. Protein concentration in pancreatic juice by CCK-8 increased steeply after 6 days old, but the ratio of amylase to protein rose abruptly at 28 days old. 4. These findings indicate that (1) the secretory capacity of bile and pancreatic juice developed predominantly at an early period of postnatal life; (2) the formation of bile acids and pancreatic digestive enzymes developed gradually during the suckling period.


Asunto(s)
Bilis/metabolismo , Páncreas/metabolismo , Factores de Edad , Amilasas/metabolismo , Animales , Animales Lactantes , Bilis/efectos de los fármacos , Electrólitos/metabolismo , Masculino , Páncreas/efectos de los fármacos , Páncreas/crecimiento & desarrollo , Jugo Pancreático/efectos de los fármacos , Jugo Pancreático/metabolismo , Proteínas/metabolismo , Secretina/farmacología , Sincalida/farmacología , Porcinos , Nervio Vago/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA