Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37942843

RESUMEN

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula Esofágica , Venas Pulmonares , Animales , Humanos , Masculino , Femenino , Temperatura , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Frecuencia Cardíaca , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 34(1): 44-53, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36259713

RESUMEN

BACKGROUND: Renal denervation (RDN) can reduce cardiac sympathetic activity maintained by arterial hypertension (aHT). Its potential antiarrhythmic effect on rhythm outcome in patients with multi-drug resistant aHT undergoing catheter ablation for atrial fibrillation (AF) is unclear. METHODS: The RDN+AF study was a prospective, randomized, two-center trial. Patients with paroxysmal or persistent AF and uncontrolled aHT (mean systolic 24-h ambulatory BP > 135 mmHg) despite taking at least three antihypertensive drugs were enrolled. Patients were 1:2 randomized to either RDN+AF ablation or AF-only ablation. Primary endpoint was freedom from any AF episode > 2 min at 12 months assessed by implantable loop recorder (ILR) or 7d-holter electrocardiogram. Secondary endpoints included rhythm outcome at 24 months, blood pressure control, periprocedural complications, and renovascular safety. RESULTS: The study randomized 61 patients (mean age 65 ± 9 years, 53% men). At 12 months, RDN+AF patients tended to have a greater decrease in ambulatory BPs but did not reach statistical significance. No differences in rhythm outcome were observed. Freedom from AF recurrence in the RDN+AF and AF-only group measured 61% versus 53% p = .622 at 12 months and 39% versus 47% p = .927 at 24 months, respectively. Periprocedural complications occurred in 9/61 patients (15%). No patient died. CONCLUSION: Among patients with multidrug-resistant aHT and paroxysmal or persistent AF, concomitant RDN+AF ablation was not associated with better blood pressure control or rhythm outcome in comparison to AF-only ablation and medical therapy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Hipertensión , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Hipertensión/diagnóstico , Hipertensión/cirugía , Simpatectomía/efectos adversos , Ablación por Catéter/efectos adversos , Recurrencia
3.
Europace ; 25(3): 880-888, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36546582

RESUMEN

AIMS: The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the 'close protocol' has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter 'very-close protocol' of 3-4 mm of inter-lesion distance (ILD) at the anterior and 5-6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. METHODS AND RESULTS: A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). CONCLUSIONS: PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.


Asunto(s)
Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos , Venas Pulmonares/cirugía , Resultado del Tratamiento
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37589146

RESUMEN

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Asunto(s)
Ablación por Catéter , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Lactante , Venas Pulmonares/cirugía , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Temperatura
5.
Circ J ; 87(12): 1722-1726, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37532529

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal energy source with promising safety and efficacy advantages. We aimed to develop a convenient, safe, effective and fast method of pulmonary vein isolation (PVI) utilizing a penta-spline PFA catheter via a single femoral vein and a venous closure system.Methods and Results: Consecutive patients (n=50; mean age: 63.6±10.7 years, 38% female) presenting with AF (paroxysmal AF: 56%) underwent first-time PVI via PFA. A single ultrasound-guided femoral vein puncture and a single transseptal puncture were used. After PVI using the penta-spline PFA catheter, extra pulse trains were added to the posterior wall for wide antral circumferential ablation. A venous closure system was used and a Donati suture was performed. The pressure bandage was removed after 1 h. A total of 196 PVs were identified and isolated with PFA only. The mean procedural time was 27.4±6.6 min, and the mean dwelling time was 14.4±5.5 min. Time to ambulation was 3.3±3.1 h. No severe complications occurred. During a mean follow-up of 6.5±2.1 months, 41/50 patients (82%) remained in sinus rhythm. CONCLUSIONS: The combination of a single venous puncture, single transseptal puncture approach using PFA and vascular closure device resulted in a 100% rate of acute PVI and an extraordinarily fast procedure and time to ambulation. The rate of periprocedural complications was low.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Catéteres
6.
Vasa ; 52(5): 317-324, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37461314

RESUMEN

Background: Thoracic endovascular aortic repair (TEVAR) is a well-established technique for the management of blunt thoracic aortic injury (BTAI). Despite improvements in vascular imaging, graft material properties, and implant techniques, stent-graft deployment artificially induces aortic stiffening. This study aimed to evaluate the midterm effect of thoracic endovascular aortic repair after blunt thoracic aortic injury on aortic stiffness and cardiac function in young patients using cardiovascular magnetic resonance (CMR) imaging. Patients and methods: From all patients who underwent TEVAR for BTAI between 2009 and 2019 in a single institution, 10 patients with no other comorbidities affecting arterial stiffness were sex-, age-, height-, and body surface area-matched to 10 healthy controls. Comprehensive CMR examination was performed in all controls and patients. The mean follow-up period was 5.4±1.8 years; the mean age at the time of TEVAR was 30.3±8.7 years. Results: Four patients who underwent TEVAR developed arterial hypertension. 4D flow CMR-based analysis demonstrated higher global pulse wave velocity (PWV) in TEVAR patients than in controls (p=0.012). Segmental analysis showed a higher PWV in the descending and abdominal aorta. The indexed diameter of the ascending aorta was larger in TEVAR patients than in controls (p=0.007). The CINE acquisitions demonstrated increased left ventricular myocardial thickness (p<0.001). The 3D global diastolic strain rate and diastolic longitudinal velocity (e') decreased, and the A-wave velocity increased. Native myocardial T1 values were significantly higher in TEVAR patients (p=0.037). Conclusions: Young patients with TEVAR after BTAI are at an increased risk of developing vascular and myocardial dysfunction due to increased aortic stiffness. CMR follow-up allows for a comprehensive and radiation-free evaluation of vascular stiffness and associated myocardial changes, especially at the early and subclinical stages.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Lesiones del Sistema Vascular , Heridas no Penetrantes , Humanos , Adulto Joven , Adulto , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Análisis de la Onda del Pulso , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Implantación de Prótesis Vascular/efectos adversos , Imagen por Resonancia Magnética , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/cirugía , Aorta Abdominal , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/cirugía , Heridas no Penetrantes/etiología , Resultado del Tratamiento
7.
Europace ; 24(6): 921-927, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34907431

RESUMEN

AIMS: Cryoballoon (CB) based pulmonary vein isolation (PVI) is a widely used technique for treatment of atrial fibrillation (AF); however the ideal energy dosing has not yet been standardized. This was a single-centre randomized clinical trial aiming at assessing the safety, acute efficacy, and clinical outcome of an individualized vs. a fixed CB ablation protocol using the fourth-generation CB (CB4) guided by pulmonary vein (PV) potential recordings and CB temperature. METHODS AND RESULTS: Patients were randomized in a 1:1 fashion to two different dosing protocols: INDI-FREEZE group (individualized protocol): freeze-cycle duration of time to effect plus 90 s or interruption of the freeze-cycle and repositioning CB if a CB temperature of -30°C was not within 40 s. Control group (fixed protocol): freeze-cycle duration of 180 s. No-bonus freeze-cycle was applied in either patient group. The primary endpoint was freedom from atrial tachyarrhythmia at 12 months. Secondary end points included procedural parameters and complications. A total of 100 patients with paroxysmal AF were prospectively enrolled. No difference was seen in the primary endpoint [INDI-FREEZE group: 38/47 (81%) vs. control group: 40/47, (85%), P = 0.583]. The total freezing time was significantly shorter in the INDI-FREEZE group (157 ± 56 s vs. 212 ± 83 s, P < 0.001), while procedure duration (57.9 ± 17.9 min vs. 63.2 ± 20.2 min, P = 0.172) was similar. No differences were seen in the minimum CB and oesophageal temperatures as well as in periprocedural complications. CONCLUSION: Compared to the fixed protocol, the individualized approach provides a similar safety profile and clinical outcome, while reducing the total freezing time.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Congelación , Humanos , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
8.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
9.
J Cardiovasc Electrophysiol ; 32(6): 1553-1560, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33760304

RESUMEN

BACKGROUND: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The novel fourth-generation cryoballoon (CB4) incorporates a 40% shorter distal tip. This design change may translate into an increased rate of PVI real-time signal recording, facilitating an individualized ablation strategy using the time to effect (TTE). METHODS AND RESULTS: Three hundred consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled. The first 150 consecutive patients underwent CB2 based PVI (CB2 group) and the last 150 consecutive patients were treated with the CB4 (CB4 group). A total of 594/594 (100%, CB4) and 589/594 (99.2%, CB2) pulmonary veins (PVs) were successfully isolated utilizing the CB4 and CB2, respectively (p = .283). The real-time PVI visualization rate was 47% (CB4) and 39% (CB2; p = .005) and the mean freeze cycle duration 200 ± 90 s (CB4) and 228 ± 110 s (CB2; p < .001), respectively. The total procedure time did not differ between the groups (CB4: 64 ± 32 min) and (CB2: 62 ± 29 min, p = .370). No differences in periprocedural complications were detected. CONCLUSIONS: A higher rate of real-time electrical PV recordings are seen using the CB4 as compared to CB2, which may facilitate an individualized ablation strategy using the TTE.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
10.
Europace ; 23(9): 1400-1408, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33693595

RESUMEN

AIMS: To characterize the association of phasic left atrial (LA) transport function and LA fibrosis guided by multimodality imaging containing cardiac magnetic resonance imaging (CMR) feature tracking and bipolar voltage mapping. METHODS AND RESULTS: Consecutive patients presenting for first-time ablation of atrial fibrillation (AF) were prospectively enrolled. Each patient underwent CMR prior to the ablation procedure. LA phasic indexed volumes (LA-Vi) and emptying fractions (LA-EF) were calculated and CMR feature tracking guided LA wall motion analysis was performed. LA bipolar voltage mapping was carried out in sinus rhythm to find areas of low voltage as a surrogate for fibrosis and arrhythmogenesis. One hundred and sixty-eight patients were enrolled. Low-voltage areas (LVAs) were present in 70 patients (42%). Contrary to LA volume, CMR based LA-EF [odds ratio (OR) 0.88, 95% confidence interval (CI) 0.80-0.96, P = 0.005] and LA booster pump strain rate (SR) (OR 0.98, 95% CI 0.97-0.99, P = 0.001) significantly predicted presence and extent of LVA in multivariate logistic regression analysis for patients scanned in SR. In receiver operating characteristic analysis, LA-EF <40% carried a sensitivity of 83% and specificity of 76% (area under the curve 0.8; 95% CI 0.71-0.89) to predict presence of LVA. For patients scanned in AF only minimal LA-Vi on CMR (OR: 1.06; 95% CI: 1.02-1.10; P = 0.002) predicted presence of LVA. CONCLUSION: For patients scanned in SR LA-EF and LA booster pump SR are closely linked to the presence and extent of LA LVA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Fibrosis , Atrios Cardíacos/cirugía , Humanos , Espectroscopía de Resonancia Magnética
11.
Circ J ; 85(8): 1296-1304, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-33854004

RESUMEN

BACKGROUND: The arctic front cryoballoon (AF-CB) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The POLARx cryoballoon incorporates unique features and design changes that may translate into improved efficacy, safety and further simplified balloon-based procedures. Efficacy and safety of the novel POLARx cryoballoon was compared to the fourth generation AF-CB (AF-CB4).Methods and Results:Twenty-five consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled, underwent POLARx-based PVI (POLARx group) and were compared to 25 consecutive patients treated with the AF-CB4 (AF-CB4 group). All PVs were successfully isolated utilizing the POLARx and AF-CB4. A significant difference regarding the mean minimal cryoballoon temperatures reached using the AF-CB4 and POLARx (-50±6℃ vs. -57±7℃, P=0.004) was observed. Real-time PVI was visualized in 81% of POLARx patients and 42% of AF-CB4 patients (P<0.001). Utilizing the POLARx, a trend towards shorter median procedure time (POLARx: 45 [39, 53] min vs. AF-CB4: 55 [50, 60] min; P=0.062) was found. No differences were observed between AF-CB4 and POLARx concerning catheter maneuverability, catheter stability and periprocedural complications. CONCLUSIONS: The novel POLARx showed similar safety and efficacy compared to the AF-CB4. A higher rate of real-time PV recordings and significantly lower minimal balloon temperatures were observed using the POLARx.


Asunto(s)
Criocirugía , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 31(7): 1587-1594, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32412119

RESUMEN

BACKGROUND: Cryoballoon ablation (CBA) for pulmonary vein isolation (PVI) is an established modality for the treatment of atrial fibrillation (AF). We report feasibility of left atrial (LA) substrate modification in addition to PVI both using the cryoballoon. METHODS: LA substrates and CBA-induced scar were assessed at baseline and 3 months after ablation using late gadolinium enhancement magnetic resonance imaging (LGE-MRI). Common periprocedural data including postablation LGE-MRI for evaluation of esophageal thermal injury, and CBA-associated complications were collected. Freedom from AF recurrence at 12 months was assessed using Holter and 30-day rhythm monitors. RESULTS: In 26 patients (64 ± 11 years, 69% male; 27% persistent AF, CHADSVASC score: 2.3 ± 1.5; left ventricular ejection fraction: 56 ± 10%, oral anticoagulation with warfarin/direct oral anticoagulants: n = 11/15), referred for first-time AF ablation, CBA of the pulmonary veins and extrapulmonary LA substrates was performed (median: 12 [interquartile range {IQR}: 7-14] freezes over 1675 seconds [IQR: 1168-2160]). On LGE-MRI, significant postablation cryoballoon-induced LA scar (median: 19.4% [IQR: 13.4-24.7] in comparison to baseline preablation LA-LGE (median: 10.6% [IQR 3.1-13.1]; P = .01) was found. Freedom from AF recurrence at 12 months was 74.5% with median time-to-recurrence of 242 days (IQR: 172-298). In 15 of 26 (58%) patients, esophageal enhancement on the postablation MRI was present with full recovery after 3 months. No major periprocedural complications were observed. CONCLUSION: LA substrate modification in addition to PVI using LGE-MRI-guided CBA is feasible but still experimental. The efficacy and safety have to be investigated in a prospective randomized trial.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Imagen por Resonancia Magnética , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Medios de Contraste , Femenino , Gadolinio , Atrios Cardíacos/cirugía , Humanos , Masculino , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 31(4): 885-894, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32037614

RESUMEN

BACKGROUND: Left atrial substrate modification targeting low voltage zones (LVZ) is an ablation strategy that-in addition to pulmonary vein (PV) isolation-tries to eliminate arrhythmogenic mechanisms harbored in such tissue. Electrophysiological findings at reablation include (a) PV reconnection, (b) reconnection over previous substrate ablation, and (c) de-novo LVZ. OBJECTIVE: To study, prevalence and contribution of these arrhythmogenic electrophysiological entities in patients with atrial fibrillation (AF) recurrences. METHODS: Consecutive patients with highly symptomatic AF undergoing index and reablation were included (n = 113). In all patients' PV reconnection, reconnection over previous substrate ablation and spontaneous de-novo LVZ were quantitatively assessed and integrated into an individual reablation strategy. Follow-up was based on continuous device monitoring. RESULTS: At re-do procedure, 45 out of 113 (39.8%) patients showed PV reconnection as the only electrophysiological abnormality. Reconduction over previous lines was the only electrophysiological abnormality in 8 out of 113 (7.1%) patients. Spontaneous de-novo LVZ was the only electrophysiological abnormality in 12 out of 113 (10.6%) patients. Combined findings of PV reconnection, line reconduction, and/or spontaneous de-novo LVZ were seen in 40 out of 113 (35.4%) patients. No detectable electrophysiological abnormality was observed in 8 out of 113 (7.1%) patients. In univariate analysis, none of the tested electrophysiological characteristics independently predicted the outcome after re-do. CONCLUSIONS: In patients undergoing reablation, we could show that reconduction over previous substrate ablation as well as the development of new low voltage areas are frequent findings besides classical PV reconnection-without a clear leading cause for recurrences. These findings impact reablation strategies as well as the strategic focus during index procedures.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
Europace ; 22(12): 1812-1821, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-32830233

RESUMEN

AIMS: Atrial fibrillation (AF) and heart failure (HF) often coexist. Catheter ablation has been reported to restore left ventricular (LV) function but patients benefit differently. This study investigated the correlation between left atrial (LA) fibrosis extent and LV ejection fraction (LVEF) recovery after AF ablation. METHODS AND RESULTS: In this study, 103 patients [64 years, 69% men, 79% persistent AF, LVEF 33% interquartile range (IQR) (25-38)] undergoing first time AF ablation were investigated. Identification of LA fibrosis and selection of ablation strategy were based on sinus rhythm voltage mapping. Continuous rhythm monitoring was used to assess ablation success. Improvement in post-ablation LVEF was measured as primary study endpoint. An absolute increase in post-ablation LVEF ≥10% was defined as 'Super Response'. Left atrial fibrosis was present in 38% of patients. After ablation LVEF increased by absolute 15% (IQR 6-25) (P < 0.001). Left ventricular ejection fraction improvement was higher in patients without LA fibrosis [15% (IQR 10-25) vs. 10% (IQR 0-20), P < 0.001]. An inverse correlation between LVEF improvement and the extent of LA fibrosis was found (R2 = 0.931). In multivariate analysis, the presence of LA fibrosis was the only independent predictor for failing LVEF improvement [odds ratio 7.2 (95% confidence interval 2.2-23.4), P < 0.001]. Echocardiographic 'Super Response' was observed in 55/64 (86%) patients without and 21/39 (54%) patients with LA fibrosis, respectively (P < 0.001). CONCLUSION: Presence and extent of LA fibrosis predict LVEF response in HF patients undergoing AF ablation. The assessment of LA fibrosis may impact prognostic stratification and clinical management in HF patients with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Femenino , Fibrosis , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
15.
Europace ; 20(FI_3): f312-f320, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29688326

RESUMEN

Aims: To study device performance, arrhythmia recurrence characteristics, and methods of outcome assessment using a novel implantable cardiac monitor (ICM) in patients undergoing ablation for atrial fibrillation (AF). Methods and results: In 419 consecutive patients undergoing first-time catheter ablation for symptomatic paroxysmal (n = 224) or persistent (n = 195) AF an ICM was injected at the end of the procedure. Telemedicine staff ensured full episode transmission coverage and manually evaluated all automatic arrhythmia episodes. Device detection metrics were calculated for ≥2, ≥6, and ≥10 min AF detection durations. Four methods of outcome assessment were studied: continuous recurrence analysis, discontinuous recurrence analysis, AF-burden analysis, and analysis of individual rhythm profiles. A total of 43 673 automatic AF episodes were transmitted over a follow-up of 15 ± 6 months. Episode-based positive predictive values changed significantly with longer AF detection durations (70.5% for ≥2 min, 81.8% for ≥6 min, and 85.9% for ≥10 min). Patients with exclusive short episode recurrences (≥2 to <6 min) were rare and their arrhythmia detection was clinically irrelevant. Different methods of outcome assessment showed a large variation (46-79%) in ablation success. Individual rhythm characteristics and subclinical AF added to this inconsistency. Analysis of AF-burden and individual rhythm profiles were least influenced and showed successful treatment in 60-70% of the patients. Conclusion: We suggest AF detection duration >6 min and AF burden >0.1% as a standardized outcome definition for AF studies to come in the future.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Electrocardiografía Ambulatoria/métodos , Frecuencia Cardíaca , Telemedicina/métodos , Telemetría/métodos , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Equipo para Diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recurrencia , Telemedicina/instrumentación , Telemetría/instrumentación , Factores de Tiempo , Resultado del Tratamiento
16.
Eur Heart J Digit Health ; 5(3): 356-362, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38774365

RESUMEN

Aims: Electroanatomical mapping (EAM) systems are essential for the treatment of cardiac arrhythmias. The EAM system is usually operated by qualified staff or field technical engineers from the control room. Novel remote support technology allows for remote access of EAM via online services. Remote access increases the flexibility of the electrophysiological lab, reduces travel time, and overcomes hospital access limitations especially during the COVID-19 pandemic. Here, we report on the feasibility and safety of EAM remote access for cardiac ablation procedures. Methods and results: Mapping and ablation were achieved by combining the EnsiteX™ EAM system and the integrated Ensite™ Connect Remote Support software, together with an integrated audiovisual solution system for remote support (Medinbox). Communication between the operator and the remote support was achieved using an incorporated internet-based common communication platform (Zoom™), headphones, and high-resolution cameras. We investigated 50 remote access-assisted consecutive electrophysiological procedures from September 2022 to February 2023 (remote group). The data were compared with matched patients (n = 50) with onsite support from the control room (control group). The median procedure time was 100 min (76, 120; remote) vs. 86 min (60, 110; control), P = 0.090. The procedural success (both groups 100%, P = 0.999) and complication rate (remote: 2%, control: 0%, P = 0.553) were comparable between the groups. Travel burden could be reduced by 11 280 km. Conclusion: Remote access for EAM was feasible and safe in this single-centre study. Procedural data were comparable to procedures with onsite support. In the future, this new solution might have a great impact on facilitating electrophysiological procedures.

17.
Int J Cardiol Heart Vasc ; 50: 101325, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38419611

RESUMEN

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods: A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results: For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions: PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.

18.
Front Cardiovasc Med ; 10: 1217745, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37435050

RESUMEN

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.

19.
J Clin Med ; 11(23)2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36498531

RESUMEN

Aims/Objectives: Patients with bleeding disorders are a rare and complex population in catheter ablation (CA) procedures. The most common types of bleeding disorders are von Willebrand disease (VWD) and hemophilia A (HA). Patients with VWD or HA tend to have a higher risk of bleeding complications compared to other patients. There is a lack of data concerning peri- and postinterventional coagulation treatment. We sought to assess the optimal management of patients with VWD and HA referred for catheter ablation procedures. Methods and Results: In this study, we analyzed patients with VWD or HA undergoing CA procedures at two centers in Germany and Switzerland between 2016 and 2021. Clotting factors were administered in conjunction with hemostaseological recommendations. CA was performed as per the institutional standard. During the procedure, unfractionated heparin (UFH) was given intravenously with respect to the activated clotting time (ACT). Primary endpoints included the feasibility of the procedure, bleeding complications, and thromboembolic events during the procedure. Secondary endpoints included bleeding complications and thromboembolic events up to one year after catheter ablation. A total of seven patients (three VWD Type I, one VWD Type IIa, three HA) underwent 10 catheter ablation procedures (pulmonary vein isolation (PVI): two × radiofrequency (RF), one × laser balloon (LB), one × cryoballoon (CB); PVI + cavotricuspid isthmus (CTI): one × RF; PVI + left atrial appendage isolation (LAAI): one × RF; Premature ventricular contraction (PVC): three × RF; Atrioventricular nodal reentrant tachycardia (AVNRT): one × RF). VWD patients received 2000−3000 IE Wilate i.v. 30 to 45 min prior to ablation. Patients with HA received 2000−3000 IE factor VIII before the procedure. All patients undergoing PVI received UFH (cumulative dose 9000−18,000 IE) with a target ACT of >300 s. All patients after PVI were started on oral anticoagulation (OAC) 12 h after ablation. Two patients received aspirin (acetylsalicylic acid; ASA) for 4 weeks after the ablation of left-sided PVCs. No anticoagulation was prescribed after slow pathway modulation in a case with AVNRT. No bleeding complications or thromboembolic events were reported. During a follow-up of one year, one case of gastrointestinal bleeding occurred following OAC withdrawal after LAA occlusion. Conclusions: After the substitution of clotting factors, catheter ablation in patients with VWD and HA seems to be safe and feasible.

20.
Int J Cardiol Heart Vasc ; 40: 101042, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35573650

RESUMEN

Objectives: We sought to assess the efficacy, safety and short-term clinical outcome of very high-power short-duration (vHP-SD) radiofrequency (RF) catheter ablation for the treatment of idiopathic PVCs originating from the cardiac outflow tract (OT). Background: Power-controlled RF ablation is a widely used technique for the treatment of premature ventricular contractions (PVCs). A novel ablation catheter offers three microelectrodes and six thermocouples at its tip and provides temperature-controlled vHP-SD (90 Watts/4 s,) with the opportunity to switch to moderate-power mode. Methods: In this pilot study, twenty-four consecutive, prospectively enrolled patients underwent PVC ablation utilizing the vHP-SD ablation (study group) and were compared with 24 consecutive patients previously treated with power-controlled ablation (control group). Each group included 12 patients with PVCs originating from the right ventricular OT (RVOT) and 12 patients with PVCs originating from the left ventricular OT (LVOT). The acute endpoint was PVC elimination and was achieved in all patients. Results: In 16/24 (67%) patients (study group) it was achieved by using vHP-SD only. The median RF delivery time was 52 (interquartile range [IQR] 16, 156) seconds (study group) and 350 (IQR 240, 442) seconds (control group, p < 0.0001). No difference was observed regarding procedure duration (p = 0.489) as well as 6-months follow-up (p = 0.712). One (4%, study group) and 2 (8%, control group) severe adverse events occured (p = 0.551). Conclusion: In this study, vHP-SD PVC ablation was similarly effective and safe as compared to conventional power-controlled ablation. The RF time was significantly shorter.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA