Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Clin Oral Investig ; 23(12): 4213-4222, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30806799

RESUMEN

OBJECTIVES: Therapy of osteomyelitis and osteonecrosis very often requires surgery. Proper preoperative radiological evaluation of a lesion's localization and extent is a key in planning surgical bone resection. This study aims to assess the differences between single-photon emission computed tomography and cone beam computed tomography when detecting an osteomyelitis/osteonecrosis lesion as well as the lesion's qualitative parameters, extent, and localization. MATERIAL AND METHODS: Identification of candidates was performed retrospectively following a search for patients with histologically or clinically confirmed osteomyelitis or osteonecrosis. They were matched with a list of patients whose disease extent and localization had been evaluated using single-photon emission computed tomography and cone beam computed tomography in the context of clinical investigations. Subsequently, two experienced examiners for each imaging technique separately performed de novo readings. Detection rate, localization, extent, and qualitative parameters of a lesion were then compared. RESULTS: Twenty-one patients with mandibular osteomyelitis and osteonecrotic lesions were included. Cone beam computed tomography detected more lesions than single-photon emission computed tomography (25 vs. 23; 100% vs. 92%). Cone beam computed tomography showed significantly greater depth, area, and volume, whereas length and width did not differ statistically between the two groups. CONCLUSION: Both single-photon emission computed tomography and cone beam computed tomography could sensitively detect osteomyelitis/osteonecrosis lesions. Only single-photon emission computed tomography showed metabolic changes, whereas cone beam computed tomography seemed to display anatomic morphological reactions more accurately. The selection of the most adequate three-dimensional imaging and the correct interpretation of preoperative imaging remains challenging for clinicians. CLINICAL RELEVANCE: In daily clinical practice, three-dimensional imaging is an important tool for evaluation of osteomyelitis/osteonecrosis lesions. In this context, clinicians should be aware of differences between single-photon emission computed tomography and cone beam computed tomography when detecting and assessing an osteomyelitis/osteonecrosis lesion, especially if a surgical bone resection is planned.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/diagnóstico por imagen , Osteomielitis/diagnóstico por imagen , Osteonecrosis/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
2.
Hematol Oncol ; 34(3): 133-9, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25689832

RESUMEN

Early relapse is common in patients with mantle cell lymphoma (MCL) highlighting the unmet need for further improvement of therapeutic options for these patients. CD20 inhibition combined with induction chemotherapy as well as consolidation with high-dose chemotherapy (HDCT) is increasingly considered cornerstones within current therapy algorithms of MCL whereas the role of radioimmunotherapy is unclear. This retrospective single center study compared 46 consecutive MCL patients receiving HDCT in first or second remission. Thirty-five patients had rituximab and BEAM (R-BEAM), and 11 patients received ibritumomab tiuxetan (Zevalin®), an Yttrium-90 labeled CD20 targeting antibody, prior to BEAM (Z-BEAM) followed by autologous stem cell transplantation (ASCT). We observed that the 5-year overall survival (OS) in the R-BEAM and Z-BEAM groups was 55% and 71% (p = 0.288), and the 4-year progression free survival (PFS) was 32% and 41%, respectively (p = 0.300). There were no treatment related deaths in both groups, and we observed no differences in toxicities, infection rates or engraftment. Our data suggest that the Z-BEAM conditioning regimen followed by ASCT is well tolerated, but was not associated with significantly improved survival compared to R-BEAM. Copyright © 2015 John Wiley & Sons, Ltd.


Asunto(s)
Algoritmos , Anticuerpos Monoclonales/administración & dosificación , Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Linfoma de Células del Manto , Rituximab/administración & dosificación , Trasplante de Células Madre , Acondicionamiento Pretrasplante , Adulto , Anciano , Autoinjertos , Carmustina/administración & dosificación , Citarabina/administración & dosificación , Supervivencia sin Enfermedad , Femenino , Humanos , Linfoma de Células del Manto/mortalidad , Linfoma de Células del Manto/terapia , Masculino , Melfalán/administración & dosificación , Persona de Mediana Edad , Podofilotoxina/administración & dosificación , Tasa de Supervivencia
3.
BMC Med Imaging ; 13: 6, 2013 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-23391039

RESUMEN

BACKGROUND: The heart is subject to structural and functional changes with advancing age. However, the magnitude of cardiac age-dependent transformation has not been conclusively elucidated. METHODS: This retrospective cardiac magnetic resonance (CMR) study included 183 subjects with normal structural and functional ventricular values. End systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) were obtained from the left and the right ventricle in breath-hold cine CMR. Patients were classified into four age groups (20-29, 30-49, 50-69, and ≥70 years) and cardiac measurements were compared using Pearson's rank correlation over the four different groups. RESULTS: With advanced age a slight but significant decrease in ESV (r=-0.41 for both ventricles, P<0.001) and EDV (r=-0.39 for left ventricle, r=-0.35 for right ventricle, P<0.001) were observed associated with a significant increase in left (r=0.28, P<0.001) and right (r=0.27, P<0.01) ventricular EF reaching a maximal increase in EF of +8.4% (P<0.001) for the left and +6.1% (P<0.01) for the right ventricle in the oldest compared to the youngest patient group. Left ventricular myocardial mass significantly decreased over the four different age groups (P<0.05). CONCLUSIONS: The aging process is associated with significant changes in left and right ventricular EF, ESV and EDV in subjects with no cardiac functional and structural abnormalities. These findings underline the importance of using age adapted values as standard of reference when evaluating CMR studies.


Asunto(s)
Envejecimiento/patología , Envejecimiento/fisiología , Algoritmos , Ventrículos Cardíacos/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Eur J Nucl Med Mol Imaging ; 39(12): 1920-6, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22926710

RESUMEN

PURPOSE: The aim of the present study was to evaluate the accuracy of hypodense regions in non-contrast-enhanced cardiac computed tomography (unenhanced CT) to identify nonviable myocardial scar tissue. METHODS: Hypodense areas were visually identified in unenhanced CT of 80 patients in the left ventricular anterior, apical, septal, lateral and inferior myocardium and CT density was measured in Hounsfield units (HU). Findings were compared to (18)F-fluorodeoxyglucose uptake by positron emission tomography (FDG PET), which served as the standard of reference to distinguish scar (<50 % FDG uptake) from viable tissue (≥50 % uptake). RESULTS: Visually detected hypodense regions demonstrated a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 74, 97, 84 and 94 %, respectively. A receiver-operating characteristic (ROC) curve analysis revealed a cutoff value of mean HU at <28.8 for predicting scar tissue with an area under the curve of 0.93 yielding a sensitivity, specificity, PPV and NPV of 94, 90, 67 and 99 %, respectively. CONCLUSION: Hypodense regions in unenhanced cardiac CT scans allow accurate identification of nonviable myocardial scar tissue.


Asunto(s)
Cicatriz/diagnóstico por imagen , Corazón/diagnóstico por imagen , Miocardio/patología , Tomografía de Emisión de Positrones , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos
5.
JBJS Case Connect ; 11(2)2021 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-34101664

RESUMEN

CASE: A 70-year-old female patient underwent total hip arthroplasty (HA) using a stem cemented line-to-line without centralizer. Postoperatively, she complained of load-dependent thigh pain. Conventional radiographs identified cortical overload because of a distal cement mantle discontinuity at the level of the stem's tip, confirmed by single-photon emission computed tomography/computed tomography scan (SPECT/CT). After cement-in-cement revision using a stem with centralizer, pain ceased rapidly. The cortical overload disappeared, as confirmed on a following SPECT/CT performed for low back pain. CONCLUSION: In HA, the stem's tip may cause overload on the bone's cortex if the cement mantle is incomplete. Implanting a stem with centralizer avoids or cures this.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Cementación/métodos , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Diseño de Prótesis , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único
6.
Clin Transl Radiat Oncol ; 31: 8-13, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34504959

RESUMEN

BACKGROUND: Patients diagnosed with locoregionally advanced head and neck squamous cell carcinoma (LAHNSCC) regularly undergo staging with 18F-FDG PET/CT in our center. In cases of delays in radiotherapy (RT) planning CT more than 4 weeks after initial PET/CT or clinically suspected progress, PET/CT is repeated for restaging and as an RT planning reference. Our aim was to determine the impact of second-look PET/CT on stage migration, treatment change and RT planning. METHODS: Consequent treatment changes were categorized as minor and major. Minor changes were defined as PET/CT-based modifications of RT plans, e.g., the addition of anatomical compartments, changes in high- and low-risk dose levels or both. Major changes included changes from curative to palliative treatment intent and alterations of interdisciplinary treatment plans, such as the addition of induction chemotherapy, switch to primary surgery, no treatment and/or the necessity of additional diagnostic work-up resulting in the postponement or cancellation of treatment. RESULTS: Thirty-two newly diagnosed LAHNSCC patients who were treated between 2014 and 2018 underwent second-look PET/CT (median interval 42.5 days). Second-look PET/CT led to locoregional and distant upstaging in 3/32 and 1/32 patients, respectively. In 1/32 patients (3%), second-look PET/CT led to a palliative approach with systemic treatment. New lymph node metastases were discovered in 16 patients, 6 of whom also showed significant progression of the primary tumor, resulting in minor changes in 16 of the remaining 31 patients (52%) who were treated curatively. CONCLUSION: If RT treatment planning of LAHNSCC was delayed by more than 4 weeks after initial PET/CT staging or when progression was clinically suspected, a second look at 18FDG-PET/CT was performed. This led to changes in treatment planning in more than half of the cases, which is expected to directly influence oncologic outcomes.

7.
Nuklearmedizin ; 60(1): 7-9, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33080626

RESUMEN

While FDG-PET imaging of the brain for the differential diagnosis of dementia has been covered by the compulsory health insurance in Switzerland for more than a decade, beta-amyloid-PET just recently has been added to the catalogue of procedures that have been cleared for routine use, provided that a set of appropriate use criteria (AUC) be followed. To provide guidance to dementia care practitioners, the Swiss Society of Nuclear Medicine and the Swiss Memory Clinics jointly report a mini-review on beta-amyloid-PET and discuss the AUC set into effect by the Swiss Federal Office of Public Health, as well as their application and limitations.


Asunto(s)
Amiloide/metabolismo , Demencia/diagnóstico por imagen , Demencia/metabolismo , Medicina Nuclear , Sociedades Médicas , Humanos , Suiza
8.
Eur J Nucl Med Mol Imaging ; 37(11): 2027-36, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20680270

RESUMEN

PURPOSE: In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. METHODS: We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. RESULTS: Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. CONCLUSION: PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions-especially without a distinctive morphological correlate-accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions.


Asunto(s)
Biopsia/métodos , Neoplasias Óseas/metabolismo , Neoplasias Óseas/patología , Tomografía de Emisión de Positrones , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Anciano , Biopsia/efectos adversos , Neoplasias Óseas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Cirugía Asistida por Computador/efectos adversos
9.
Ther Umsch ; 67(10): 505-10, 2010 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-20886456

RESUMEN

Positron-Emission-Tomography (PET) has emerged as a diagnostic gold standard for most tumor entities during the last 20 years, especially for patients suffering from malignant lymphoma. The development and distribution of machines allowing for hybrid imaging, i.e. the simultaneous acquisition of PET and CT datasets, and the possibility to assess even small pathologic findings with fused PET/CT image visualization, once more significantly improved the diagnostic accuracy of PET. Based on an excellent sensitivity the metabolic imaging with PET or PET/CT allows for a reliable overall assessment of patients with malignant lymphoma before therapy, for the early identification of non-responders during therapy, and for the diagnosis of relapse after therapy.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Linfoma/diagnóstico , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Antineoplásicos/uso terapéutico , Progresión de la Enfermedad , Fluorodesoxiglucosa F18 , Humanos , Linfoma/tratamiento farmacológico , Linfoma/patología , Estadificación de Neoplasias , Neoplasia Residual/diagnóstico , Neoplasia Residual/tratamiento farmacológico , Neoplasia Residual/patología , Radiofármacos , Sensibilidad y Especificidad
10.
Case Rep Oncol ; 13(2): 729-732, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32774266

RESUMEN

Anaplastic lymphoma kinase (ALK) tyrosine kinase inhibitors (TKIs) are established effective therapies in patients with ALK-rearranged advanced non-small-cell lung cancer (NSCLC). Upon progressive disease, patients normally receive a subsequent ALK TKI. However, when disease progression occurs in a limited number of sites, an oligoprogressive approach is a treatment option. In our case, FDG-PET/CT scan detected a progressive site in a patient with ceritinib therapy. Biopsy of the lesion was not possible because of its location. Progression was therefore confirmed by liquid biopsy with identification of the resistant subclone ALK G1202R. Definitive radiotherapy of the progressive site led to the disappearance of the ALK-resistant mutation. Meanwhile, ceritinib therapy was continued. The absence of disease both on repeated imaging and liquid biopsy indicates that eradication of a resistant subclone with an oligoprogressive treatment approach might be possible.

11.
EJNMMI Phys ; 7(1): 22, 2020 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-32323035

RESUMEN

BACKGROUND: For multicenter clinical studies, PET/CT and SPECT/CT scanners need to be validated to ensure comparability between various scanner types and brands. This validation is usually performed using hollow phantoms filled with radioactive liquids. In recent years, 3D printing technology has gained increasing popularity for manufacturing of phantoms, as it is cost-efficient and allows preparation of phantoms of almost any shape. So far, however, direct 3D printing with radioactive building materials has not yet been reported. The aim of this work was to develop a procedure for preparation of 99mTc-containing building materials and demonstrate successful application of this material for 3D printing of several test objects. METHOD: The desired activity of a [99mTc]pertechnetate solution eluted from a 99Mo/99mTc-generator was added to the liquid 3D building material, followed by a minute amount of trioctylphosphine. The resulting two-phase mixture was thoroughly mixed. Following separation of the phases and chemical removal of traces of water, the radioactive building material was diluted with the required volume of non-radioactive building material and directly used for 3D printing. RESULTS: Using our optimized extraction protocol with trioctylphosphine as complex-forming phase transfer agent, technetium-99m was efficiently transferred from the aqueous 99Mo/99mTc-generator eluate into the organic liquid resin monomer. The observed radioactivity concentration ratio between the organic phase and the water phase was > 2000:1. The radioactivity was homogeneously distributed in the liquid resin monomer. We did not note differences in the 3D printing behavior of the radiolabeled and the unlabeled organic liquid resin monomers. Radio-TLC and SPECT studies showed homogenous 2D and 3D distribution of radioactivity throughout the printed phantoms. The radioactivity was stably bound in the resin, apart from a small amount of surface-extractable radioactivity under harsh conditions (ethanol at 50 °C). CONCLUSIONS: 3D printing of radioactive phantoms using 99mTc-containing building materials is feasible. Compared to the classical fillable phantoms, 3D printing with radioactive building materials allows manufacturing of phantoms without cold walls and in almost any shape. Related procedures with longer-lived radionuclides will enable production of phantoms for scanner validation and quality control.

12.
PLoS One ; 15(3): e0229560, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32176698

RESUMEN

PURPOSE: Image texture is increasingly used to discriminate tissues and lesions in PET/CT. For quantification or in computer-aided diagnosis, textural feature analysis must produce robust and comparable values. Because statistical feature values depend on image count statistics, we investigated in depth the stability of Haralick features values as functions of acquisition duration, and for common image resolutions and reconstructions. METHODS: A homogeneous cylindrical phantom containing 9.6 kBq/ml Ge-68 was repeatedly imaged on a Siemens Biograph mCT, with acquisition durations ranging from three seconds to three hours. Images with 1.5, 2, and 4 mm isometrically spaced voxels were reconstructed with filtered back-projection (FBP), ordered subset expectation maximization (OSEM), and the Siemens TrueX algorithm. We analysed Haralick features derived from differently quantized (3 to 8-bit) grey level co-occurrence matrices (GLCMs) as functions of exposure E, which we defined as the product of activity concentration in a volume of interest (VOI) and acquisition duration. The VOI was a 50 mm wide cube at the centre of the phantom. Feature stability was defined for df/dE → 0. RESULTS: The most stable feature values occurred in low resolution FBPs, whereas some feature values from 1.5 mm TrueX reconstructions ranged over two orders of magnitude. Within the same reconstructions, most feature value-exposure curves reached stable plateaus at similar exposures, regardless of GLCM quantization. With 8-bit GLCM, median time to stability was 16 s and 22 s for FBPs, 18 s and 125 s for OSEM, and 23 s, 45 s, and 76 s for PSF reconstructions, with longer durations for higher resolutions. Stable exposures coincided in OSEM and TrueX reconstructions with image noise distributions converging to a Gaussian. In FBP, the occurrence of stable values coincided the disappearance of negatives image values in the VOI. CONCLUSIONS: Haralick feature values depend strongly on exposure, but invariance exists within defined domains of exposure. Here, we present an easily replicable procedure to identify said stable exposure domains, where image noise does not substantially add to textural feature values. Only by imaging at predetermined feature-invariant exposure levels and by adjusting exposure to expected activity concentrations, can textural features have a quantitative use in PET/CT. The necessary exposure levels are attainable by modern PET/CT systems in clinical routine.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Algoritmos , Animales , Fluorodesoxiglucosa F18 , Humanos , Fantasmas de Imagen/estadística & datos numéricos , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Tomografía Computarizada por Tomografía de Emisión de Positrones/estadística & datos numéricos , Tomografía de Emisión de Positrones/métodos , Radiofármacos
13.
Eur Radiol ; 19(7): 1780-5, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19238391

RESUMEN

Positron emission tomography-computed tomography (PET-CT) has gained widespread acceptance as a staging investigation in the diagnostic workup of malignant tumours and may be used to visualize metabolic changes before the evolution of morphological changes. To make histology of PET findings without distinctive structural changes available for treatment decisions, we developed a protocol for multimodal image-guided interventions using an integrated PET-CT machine. We report our first experience in 12 patients admitted for staging and restaging of breast cancer, non-small cell lung cancer, cervical cancer, soft tissue sarcoma, and osteosarcoma. Patients were repositioned according to the findings in PET-CT and intervention was planned based on a subsequent single-bed PET-CT acquisition of the region concerned. The needle was introduced under CT guidance in a step-by-step technique and correct needle position in the centre of the FDG avid lesion was assured by repetition of a single-bed PET-CT acquisition before sampling. The metabolically active part of lesions was accurately targeted in all patients and representative samples were obtained in 92%. No major adverse effects occurred. We conclude that PET-CT guidance for interventions is feasible and may be promising to optimize the diagnostic yield of CT-guided interventions and to make metabolically active lesions without morphological correlate accessible to percutaneous interventions.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias/diagnóstico , Neoplasias/cirugía , Tomografía de Emisión de Positrones/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Radiofármacos , Sensibilidad y Especificidad , Técnica de Sustracción , Resultado del Tratamiento , Adulto Joven
14.
Onkologie ; 32(12): 724-30, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20016233

RESUMEN

BACKGROUND: Only responding patients benefit from preoperative therapy for locally advanced esophageal carcinoma. Early detection of non-responders may avoid futile treatment and delayed surgery. PATIENTS AND METHODS: In a multi-center phase ll trial, patients with resectable, locally advanced esophageal carcinoma were treated with 2 cycles of induction chemotherapy followed by chemoradiotherapy (CRT) and surgery. Positron emission tomography with 2[fluorine-18]fluoro-2-deoxy-d-glucose (FDG-PET) was performed at baseline and after induction chemotherapy. The metabolic response was correlated with tumor regression grade (TRG). A decrease in FDG tumor uptake of less than 40% was prospectively hypothesized as a predictor for histopathological non-response (TRG > 2) after CRT. RESULTS: 45 patients were included. The median decrease in FDG tumor uptake after chemotherapy correlated well with TRG after completion of CRT (p = 0.021). For an individual patient, less than 40% decrease in FDG tumor uptake after induction chemotherapy predicted histopathological non-response after completion of CRT, with a sensitivity of 68% and a specificity of 52% (positive predictive value 58%, negative predictive value 63%). CONCLUSIONS: Metabolic response correlated with histopathology after preoperative therapy. However, FDG-PET did not predict non-response after induction chemotherapy with sufficient clinical accuracy to justify withdrawal of subsequent CRT and selection of patients to proceed directly to surgery.


Asunto(s)
Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/terapia , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Pronóstico , Estudios Prospectivos , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Suiza , Resultado del Tratamiento
15.
Open Forum Infect Dis ; 6(4): ofz130, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31008142

RESUMEN

Cardiac implantable electronic device-related infection is clinically challenging. Curative treatment commonly includes system removal. A case caused by Granulicatella adiacens occurred in a 32-year-old woman. Clinical course, literature review, and biofilm investigations enabled successful antibiotic management without system removal.

16.
Gynecol Oncol ; 110(3): 324-8, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18582920

RESUMEN

OBJECTIVES: Lymph node status is an important prognostic factor in patients with squamous cell carcinoma (SCC) of the vulva. Complete inguinofemoral lymph node dissection (ILND) is accompanied by a high morbidity. Sentinel lymph node biopsy (SLNB) was established for less invasive lymph node (LN) staging. The aim of this study was to evaluate safety of SLNB in terms of accuracy and outcome in a clinical routine setting. METHODS: We retrospectively reviewed the data of patients who underwent SLNB and/or ILND for vulvar SCC in the years 1990-2007. Clinical follow-up was evaluated for histological nodal-negative patients with tumor stage T1 or T2. The false negative rate of SLNB was determined in patients who underwent both SLNB and ILND. RESULTS: Preoperative sentinel lymph node (SLN) visualization by scintigraphy was successful in 95% of all patients. SLNB was false negative in 1/45 inguinae (2.2%). All SLN were detected intraoperatively. During the follow-up period (median 24 months for SLNB and 111 months for ILND), no groin recurrences in initially nodal negative patients occurred (n=34, 59 inguinae). Transient lymph edema occurred in 7/18 patients after ILND (39%) and 2/16 patients (13%) after SLNB. No persistent edemas were found after SLNB and ILND. CONCLUSION: According to our experience SLNB is feasible and accurately predicts LN status of vulvar SCC under clinical routine conditions. SLNB in vulvar cancer seems to be a safe alternative to ILND in order to reduce morbidity of surgical treatment.


Asunto(s)
Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/cirugía , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Neoplasias de la Vulva/patología , Neoplasias de la Vulva/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/diagnóstico por imagen , Supervivencia sin Enfermedad , Reacciones Falso Negativas , Femenino , Estudios de Seguimiento , Humanos , Escisión del Ganglio Linfático/efectos adversos , Ganglios Linfáticos/diagnóstico por imagen , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Estadificación de Neoplasias , Cintigrafía , Radiofármacos , Estudios Retrospectivos , Biopsia del Ganglio Linfático Centinela/efectos adversos , Biopsia del Ganglio Linfático Centinela/métodos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Resultado del Tratamiento , Neoplasias de la Vulva/diagnóstico por imagen
18.
J Nucl Med ; 2018 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-29880508

RESUMEN

Rationale: (18F)fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) for staging Hodgkin lymphoma may allow for accurate and reliable assessment of the metabolic tumour volume (MTV) as baseline risk factor. Our aim was to analyse the prognostic impact of MTV measurements, obtained by different means in advanced-stage Hodgkin lymphoma patients treated within the German Hodgkin Study Group HD18 trial. Methods: Within the German Hodgkin Study Group trial HD18, 310 patients underwent 18F-FDG PET/CT scanning for staging which was available to the central review panel for quantitative analysis. We calculated the MTV by four different thresholding methods and performed receiver operating characteristic (ROC) analysis to evaluate the potential for prediction of early response determined by PET after two cycles (PET-2) dose-escalated bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone (eBEACOPP). Logistic regression was used to evaluate its prognostic value concerning progression-free survival (PFS) and overall survival (OS). Results: All different MTV calculations used predicted PET-2 response to a moderate and comparable degree (area under the curve = 0.62-0.63, P = 0.01-0.06). With none of the measuring methods did the ROC curves point to any unique cut-off values, but indicated a wide range of possible cut-offs. However, none of the MTV measurements was prognostic for PFS (Hazard ratio 1.2-1.5, P = 0.15-0.52) or OS (Hazard ratio 1.0-1.5, P = 0.95 - 0.27). Conclusion: Baseline MTV as determined by different means, is a predictive factor for early response to eBEACOPP after two cycles. However, value as a prognostic factor after highly effective PET-2 adapted treatment strategy could not be observed.

19.
Med Phys ; 44(4): 1558-1562, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28206679

RESUMEN

PURPOSE: To determine the thyroid clearance effective half-life T with a common handheld electronic dosimeter (ED) in patients undergoing radioiodine treatment for hyperthyroidism. METHODS: Dose rates from 12 inpatients were measured daily with an ED and with a clinical uptake counter. The ED was attached to the patient with two different setups, one using a cervical collar and another employing a neck strap. Estimation of T was performed by linear regression analysis of the log of both the ED and the uptake counter measurements versus time. The latter provided the reference data. RESULTS: Based on repeated neck strap dose rate measurements, individual Ts were determined with clinically required accuracy. The mean difference from the reference method equaled to -0.09 ± 0.35 days. CONCLUSIONS: Determination of individual T is feasible with a common handheld ED using the simple and easy to instruct neck strap measurement setup. This simple method complements stationary uptake counter measurements and thus may improve the accuracy of radioiodine treatment planning by adding an individual T for dose calculation.


Asunto(s)
Equipos y Suministros Eléctricos , Radiometría/instrumentación , Glándula Tiroides/metabolismo , Semivida , Humanos , Hipertiroidismo/metabolismo , Hipertiroidismo/radioterapia , Radioisótopos de Yodo/metabolismo , Radioisótopos de Yodo/uso terapéutico , Glándula Tiroides/efectos de la radiación
20.
Med Phys ; 44(7): 3761-3766, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28494090

RESUMEN

PURPOSE: Avoiding measurement variability from 18 F phantom preparation by using 68 Ge/68 Ga phantoms for the determination of 18 F recovery curves (RC) in clinical quality assurance measurements and for PET/CT site qualification in multicentre clinical trials. METHODS: RCs were obtained from PET/CT measurements of seven differently sized phantom spheres filled either with 18 F or with 68 Ga. RCs for the respective other isotope were then determined by two different methods: In the first method, images were convolved with positron range transconvolution functions derived from positron annihilation distributions found in literature. This method generated recasted images matching images using the respective other isotope. In the second method, the PET/CT system's isotope independent (intrinsic) point spread function was determined from said phantom measurements and convolved with numerical representations simulating hot spheres filled with the respective other isotope. These simulations included the isotope specific positron annihilation distributions. Recovered activity concentrations were compared between recasted images, simulated images, and the originally acquired images. RESULTS: 18 F and 68 Ga recovery was successfully determined from image acquisitions of the respective opposite isotope as well as from the simulations. 68 Ga RCs derived from 18 F data had a normalized root-mean-square deviation (NRMSD) from real 68 Ga measurements of 0.019% when using the first method and of 0.008% when using the second method. 18 F RCs derived from 68 Ga data had a NRMSD from real 18 F measurements of 0.036% when using the first method and of 0.038% when using the second method. CONCLUSIONS: Applying the principles of transconvolution, 18 F RCs can be recalculated from 68 Ga phantom measurements with excellent accuracy. The maximal additionally introduced error was below 0.4% of the error currently accepted for RCs in the site qualification of multicentre clinical trials by the EARL program of the European Association of Nuclear Medicine (EANM). Therefore, our methods legitimately allow for the use of long-lived solid state 68 Ge/68 Ga phantoms instead of manually prepared 18 F phantoms to characterize comparability of 18 F measurements across different imaging sites or of longitudinal 18 F measurements at a single PET/CT system.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Electrones , Humanos , Tomografía de Emisión de Positrones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA