Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Nat Biotechnol ; 24(9): 1115-22, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16964225

RESUMEN

We have evaluated the performance characteristics of three quantitative gene expression technologies and correlated their expression measurements to those of five commercial microarray platforms, based on the MicroArray Quality Control (MAQC) data set. The limit of detection, assay range, precision, accuracy and fold-change correlations were assessed for 997 TaqMan Gene Expression Assays, 205 Standardized RT (Sta)RT-PCR assays and 244 QuantiGene assays. TaqMan is a registered trademark of Roche Molecular Systems, Inc. We observed high correlation between quantitative gene expression values and microarray platform results and found few discordant measurements among all platforms. The main cause of variability was differences in probe sequence and thus target location. A second source of variability was the limited and variable sensitivity of the different microarray platforms for detecting weakly expressed genes, which affected interplatform and intersite reproducibility of differentially expressed genes. From this analysis, we conclude that the MAQC microarray data set has been validated by alternative quantitative gene expression platforms thus supporting the use of microarray platforms for the quantitative characterization of gene expression.


Asunto(s)
Perfilación de la Expresión Génica/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Garantía de la Calidad de Atención de Salud/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Perfilación de la Expresión Génica/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
J Mol Diagn ; 5(3): 176-83, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12876208

RESUMEN

Morphological analysis of cytologic samples obtained by fine-needle aspirate (FNA) or bronchoscopy is an important method for diagnosing bronchogenic carcinoma. However, this approach has only about 65 to 80% diagnostic sensitivity. Based on previous studies, the c-myc x E2F-1/p21WAF1/CIP1 (p21 hereafter) gene expression index is highly sensitive and specific for distinguishing normal from malignant bronchial epithelial tissues. In an effort to improve sensitivity of diagnosing lung cancer in cytologic specimens, we used Standardized Reverse Transcriptase Polymerase Chain Reaction (StaRT-PCR) to measure the c-myc x E2F-1/p21 index in cDNA samples from 14 normal lung samples (6 normal lung parenchyma and 8 normal bronchial epithelial cell [NBEC] biopsies), and 16 FNA biopsies from 14 suspected tumors. Based on cytomorphologic criteria, 11 of the 14 suspected tumors were diagnosed as bronchogenic carcinoma and three specimens were non-diagnostic. Subsequent biopsy samples confirmed that the three non-diagnostic samples were derived from lung carcinomas. The index value for each bronchogenic carcinoma was above a cut-off value of 7000 and the index value of all but one normal sample was below 7000. Thus the c-myc x E2F-1/p21 index may augment cytomorphologic diagnosis of bronchogenic carcinoma biopsy samples, particularly those considered non-diagnostic by cytomorphologic criteria.


Asunto(s)
Biopsia con Aguja , Proteínas de Ciclo Celular , Ciclinas/genética , Proteínas de Unión al ADN , Genes myc , Neoplasias Pulmonares/diagnóstico , Factores de Transcripción/genética , Anciano , Inhibidor p21 de las Quinasas Dependientes de la Ciclina , Factores de Transcripción E2F , Factor de Transcripción E2F1 , Femenino , Expresión Génica , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
3.
Methods Mol Biol ; 258: 13-41, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14970455

RESUMEN

Standardized reverse transcriptase polymerase chain reaction (StaRT-PCR) is a modification of the competitive template (CT) RT method described by Gilliland et al. StaRT-PCR allows rapid, reproducible, standardized, quantitative measurement of data for many genes simultaneously. An internal standard CT is prepared for each gene, cloned to generate enough for 10(9) assays and CTs for up to 1,000 genes are mixed together. Each target gene is normalized to a reference gene to control for cDNA loaded in a standardized mixture of internal standards (SMIS) into the reaction. Each target gene and reference gene is measured relative to its respective internal standard within the SMIS. Because each target gene and reference gene is simultaneously measured relative to a known number of internal standard molecules in the SMIS, it is possible to report each gene expression measurement as a numerical value in units of target gene cDNA molecules/ 10(6) reference gene cDNA molecules. Calculation of data in this format allows for entry into a common databank, direct interexperimental comparison, and combination of values into interactive gene expression indices.


Asunto(s)
Expresión Génica , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/normas , ADN Complementario/análisis , Humanos , ARN Mensajero/análisis , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos
5.
Clin Chem ; 53(6): 1030-7, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17434908

RESUMEN

BACKGROUND: Transcript abundance (TA) measurement in whole blood frequently is conducted to identify potential biomarkers for disease risk and to predict or monitor drug response. Potential biomarkers discovered in this way must be validated by quantitative technology. In this study we assessed the use of standardized reverse transcription PCR (StaRT-PCR) to validate potential biomarkers discovered through whole blood TA profiling. METHODS: For each of 15 healthy volunteers, 6 blood samples were obtained, including 3 samples at each of 2 separate visits. Total variation in TA for each gene was partitioned into replicate, sample, visit, study participant, and residual components. RESULTS: Variation originating from technical processing was <5% of total combined variation and was primarily preanalytical. Interindividual biological sample variation was larger than technical variation. For 12 of 19 tests, the distribution of measured values was gaussian (Shapiro-Wilks test). CONCLUSION: For control or diseased population groups with variation rates as low as those observed in this control group, 17 individuals per group would be required to detect 1 SD change with 80% power with a 2-sided alpha = 0.05 statistical test for mean differences.


Asunto(s)
Biomarcadores/sangre , Perfilación de la Expresión Génica/normas , Variación Genética , Técnicas de Diagnóstico Molecular/normas , Interpretación Estadística de Datos , Perfilación de la Expresión Génica/estadística & datos numéricos , Humanos , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Control de Calidad , Valores de Referencia , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA