1.
Neuromodulation ; 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38819342

RESUMEN

OBJECTIVES: This study aimed to indicate the feasibility of a prototype electrical neuromodulation system using a closed-loop energy-efficient ultrasound-based mechanism for communication, data transmission, and recharging. MATERIALS AND METHODS: Closed-loop deep brain stimulation (DBS) prototypes were designed and fabricated with ultrasonic wideband (UsWB) communication technology and miniaturized custom electronics. Two devices were implanted short term in anesthetized Göttingen minipigs (N = 2). Targeting was performed using preoperative magnetic resonance imaging, and locations were confirmed postoperatively by computerized tomography. DBS systems were tested over a wide range of stimulation settings to mimic minimal, typical, and/or aggressive clinical settings, and evaluated for their ability to transmit data through scalp tissue and to recharge the DBS system using UsWB. RESULTS: Stimulation, communication, reprogramming, and recharging protocols were successfully achieved in both subjects for amplitude (1V-6V), frequency (50-250 Hz), and pulse width (60-200 µs) settings and maintained for ≥six hours. The precision of pulse settings was verified with <5% error. Communication rates of 64 kbit/s with an error rate of 0.05% were shown, with no meaningful throughput degradation observed. Time to recharge to 80% capacity was <9 minutes. Two DBS systems also were implanted in the second test animal, and independent bilateral stimulation was successfully shown. CONCLUSIONS: The system performed at clinically relevant implant depths and settings. Independent bilateral stimulation for the duration of the study with a 4F energy storage and full rapid recharge were achieved. Continuous function extrapolates to six days of continuous stimulation in future design iterations implementing application specific integrated circuit level efficiency and 15F storage capacitance. UsWB increases energy efficiency, reducing storage requirements and thereby enabling device miniaturization. The device can enable intelligent closed-loop stimulation, remote system monitoring, and optimization and can serve as a power/data gateway to interconnect the intrabody network with the Internet of Medical Things.

2.
Platelets ; 30(1): 112-119, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29182470

RESUMEN

Thrombosis and bleeding are devastating adverse events in patients supported with blood-contacting medical devices (BCMDs). In this study, we delineated that high non-physiological shear stress (NPSS) caused platelet dysfunction that may contribute to both thrombosis and bleeding. Human blood was subjected to NPSS with short exposure time. Levels of platelet surface GPIbα and GPVI receptors as well as activation level of GPIIb/IIIa in NPSS-sheared blood were examined with flow cytometry. Adhesion of sheared platelets on fibrinogen, von Willibrand factor (VWF), and collagen was quantified with fluorescent microscopy. Ristocetin- and collagen-induced platelet aggregation was characterized by aggregometry. NPSS activated platelets in a shear and exposure time-dependent manner. The number of activated platelets increased with increasing levels of NPSS and exposure time, which corresponded well with increased adhesion of sheared platelets on fibrinogen. Concurrently, NPSS caused shedding of GPIbα and GPVI in a manner dependent on shear and exposure time. The loss of intact GPIbα and GPVI increased with increasing levels of NPSS and exposure time. The number of platelets adhered on VWF and collagen decreased with increasing levels of NPSS and exposure time, respectively. The decrease in the number of platelets adhered on VWF and collagen corresponded well with the loss in GPIbα and GPVI on platelet surface. Both ristocetin- and collagen-induced platelet aggregation in sheared blood decreased with increasing levels of NPSS and exposure time. The study clearly demonstrated that high NPSS causes simultaneous platelet activation and receptor shedding, resulting in a paradoxical effect on platelet function via two distinct mechanisms. The results from the study suggested that the NPSS could induce the concurrent propensity for both thrombosis and bleeding in patients.


Asunto(s)
Plaquetas/metabolismo , Hemostáticos/farmacología , Resistencia al Corte , Trombosis/sangre , Adulto , Colágeno/metabolismo , Femenino , Fibrinógeno/metabolismo , Voluntarios Sanos , Humanos , Masculino , Activación Plaquetaria , Agregación Plaquetaria , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/metabolismo , Puntaje de Propensión , Adulto Joven , Factor de von Willebrand/metabolismo
3.
Mol Cell Biochem ; 433(1-2): 125-137, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28343311

RESUMEN

Non-surgical bleeding (NSB) is the most common clinical complication in heart failure (HF) patients supported by continuous-flow left ventricular assist devices (CF-LVADs). In this study, oxidative stress and alteration of signal pathways leading to platelet apoptosis were investigated. Thirty-one HF patients supported by CF-LVADs were divided into bleeder (n = 12) and non-bleeder (n = 19) groups. Multiple blood samples were collected at pre-implant (baseline) and weekly up to 1-month post-implant. A single blood sample was collected from healthy subjects (reference). Production of reactive oxygen species (ROS) in platelets, total antioxidant capacity (TAC), oxidized low-density lipoproteins (oxLDL), expression of Bcl-2 and Bcl-xL, Bax and release of cytochrome c (Cyt.c), platelet mitochondrial membrane potential (Δψ m), activation of caspases, gelsolin cleavage and platelet apoptosis were examined. Significantly elevated ROS, oxLDL and depleted TAC were evident in the bleeder group compared to non-bleeder group (p < 0.05). Platelet pro-survival proteins (Bcl-2, Bcl-xL) were significantly reduced in the bleeder group in comparison to the non-bleeder group (p < 0.05). Translocation of Bax into platelet mitochondria membrane and subsequent release of Cyt.c were more prevalent in the bleeder group. Platelet mitochondrial damage, activation of caspases, gelsolin cleavage, and ultimate platelet apoptosis in the bleeder group were observed. Oxidative stress and activation of both intrinsic and extrinsic pathways of platelet apoptosis may be linked to NSB in CF-LVAD patients. Additionally, biomarkers of oxidative stress, examination of pro-survivals and pro-apoptotic proteins in platelets, mitochondrial damage, caspase activation, and platelet apoptosis may be used to help identify HF patients at high risk of NSB post-implant.


Asunto(s)
Apoptosis , Plaquetas/metabolismo , Insuficiencia Cardíaca , Corazón Auxiliar/efectos adversos , Hemorragia , Estrés Oxidativo , Adulto , Anciano , Plaquetas/patología , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/terapia , Hemorragia/sangre , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad
4.
Artif Organs ; 40(7): 659-68, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26582038

RESUMEN

Blood can become hypercoagulable by shear-induced platelet activation and generation of microparticles. It has been reported that nonphysiological shear stress (NPSS) could induce shedding of platelet receptor glycoprotein (GP) Ibα, which may result in an opposite effect to hemostasis. The aim of this study was to investigate the influence of the NPSS on platelets and von Willebrand factor (vWF). Human blood was exposed to two levels of NPSS (25 Pa, 125 Pa) with an exposure time of 0.5 s, generated by using a novel blood-shearing device. Platelet activation (P-selectin expression, GPIIb/IIIa activation and generation of microparticles) and shedding of three platelet receptors (GPIbα, GPVI, GPIIb/IIIa) in sheared blood were quantified using flow cytometry. Aggregation capacity of sheared blood induced by ristocetin and collagen was evaluated using an aggregometer. Shear-induced vWF damage was characterized with Western blotting. Consistent with the published data, the NPSS caused significantly more platelets to become activated with increasing NPSS level. Meanwhile, the NPSS induced the shedding of platelet receptors. The loss of the platelet receptors increased with increasing NPSS level. The aggregation capacity of sheared blood induced by ristocetin and collagen decreased. There was a loss of high molecular weight multimers (HMWMs) of vWF in sheared blood. These results suggest that the NPSS induced a paradoxical effect. More activated platelets increase the risk of thrombosis, while the reduction in platelet receptors and the loss of HMWM-vWF increased the propensity of bleeding. The finding might provide a new perspective to understand thrombosis and acquired bleeding disorder in patients supported with blood contacting medical devices.


Asunto(s)
Plaquetas/metabolismo , Estrés Mecánico , Trombosis/etiología , Factor de von Willebrand/metabolismo , Adulto , Plaquetas/citología , Femenino , Hemorragia/sangre , Hemorragia/etiología , Hemorragia/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Activación Plaquetaria , Agregación Plaquetaria , Glicoproteínas de Membrana Plaquetaria/análisis , Glicoproteínas de Membrana Plaquetaria/metabolismo , Trombosis/sangre , Trombosis/metabolismo , Adulto Joven , Factor de von Willebrand/análisis
5.
Artif Organs ; 40(5): 434-43, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26416627

RESUMEN

The role of oxidative stress and leukocyte activation has not been elucidated in developing systemic inflammatory response syndrome (SIRS) in heart failure (HF) patients after continuous-flow left ventricular assist device (CF-LVAD) implantation. The objective of this study was to investigate the change of plasma redox status and leukocyte activation in CF-LVAD implanted HF patients with or without SIRS. We recruited 31 CF-LVAD implanted HF patients (16 SIRS and 15 non-SIRS) and 11 healthy volunteers as the control. Pre- and postimplant blood samples were collected from the HF patients. Plasma levels of oxidized low-density lipoprotein (oxLDL), malondialdehyde (MDA), total antioxidant capacity (TAC), superoxide dismutase (SOD) in erythrocyte, myeloperoxidase (MPO), and polymorphonuclear elastase (PMN-elastase) were measured. The HF patients had a preexisting condition of oxidative stress than healthy controls as evident from the higher oxLDL and MDA levels as well as depleted SOD and TAC. Leukocyte activation in terms of higher plasma MPO and PMN-elastase was also prominent in HF patients than controls. Persistent oxidative stress and reduced antioxidant status were found to be more belligerent in HF patients with SIRS after the implantation of CF-LVAD when compared with non-SIRS patients. Similar to oxidative stress, the activation of blood leukocyte was significantly highlighted in SIRS patients after implantation compared with non-SIRS. We identified that the plasma redox status and leukocyte activation became more prominent in CF-LVAD implanted HF patients who developed SIRS. Our findings suggest that plasma biomarkers of oxidative stress and leukocyte activation may be associated with the development of SIRS after CF-LVAD implant surgery.


Asunto(s)
Insuficiencia Cardíaca/complicaciones , Corazón Auxiliar/efectos adversos , Leucocitos/patología , Estrés Oxidativo , Síndrome de Respuesta Inflamatoria Sistémica/sangre , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/cirugía , Humanos , Lipoproteínas LDL/sangre , Masculino , Malondialdehído/sangre , Persona de Mediana Edad , Oxidación-Reducción , Síndrome de Respuesta Inflamatoria Sistémica/patología
6.
Mol Cell Biochem ; 409(1-2): 93-101, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26160282

RESUMEN

The purpose of this study was to investigate the influence of non-physiological high shear stress on activation and shedding of platelet GP IIb/IIIa receptors. The healthy donor blood was exposed to three levels of high shear stresses (25, 75, 125 Pa) from the physiological to non-physiological status with three short exposure time (0.05, 0.5, 1.5 s), created by a specific blood shearing system. The activation and shedding of the platelet GPIIb/IIIa were analyzed using flow cytometry and enzyme-linked immunosorbent assay. In addition, platelet P-selectin expression of sheared blood, which is a marker for activated platelets, was also analyzed. The results from the present study showed that the number of activated platelets, as indicated by the surface GPIIb/IIIa activation and P-selectin expression, increased with increasing the shear stress level and exposure time. However, the mean fluorescence of GPIIb/IIIa on the platelet surface, decreased with increasing the shear stress level and exposure time. The reduction of GPIIb/IIIa on the platelet surface was further proved by the reduction of further activated platelet GPIIb/IIIa surface expression induced by ADP and the increase in GPIIb/IIIa concentration in microparticle-free plasma with increasing the applied shear stress and exposure time. It is clear that non-physiological shear stress induce a paradoxical phenomenon, in which both activation and shedding of the GPIIb/IIIa on the platelet surface occur simultaneously. This study may offer a new perspective to explain the reason of both increased thrombosis and bleeding events in patients implanted with high shear blood-contacting medical devices.


Asunto(s)
Plaquetas/patología , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/metabolismo , Prótesis e Implantes/efectos adversos , Estrés Mecánico , Estrés Fisiológico/fisiología , Coagulación Sanguínea , Ensayo de Inmunoadsorción Enzimática , Femenino , Citometría de Flujo , Hemorragia/patología , Humanos , Masculino , Selectina-P/metabolismo , Activación Plaquetaria/fisiología , Agregación Plaquetaria/fisiología , Trombosis/patología
7.
ASAIO J ; 70(5): 338-347, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557701

RESUMEN

We characterize the anatomy and function of never before studied total artificial hearts (TAHs) using established methods for testing mechanical circulatory support (MCS) devices. A historical review of TAHs is also presented to aid in benchmarking performance metrics. Six TAHs, ranging from spooky Halloween beating hearts to a cute colorful plush heart, were imaged, instrumented (mock flow loops) to measure their pressure, volume, and flow, and qualitatively evaluated by 3rd party cardiac surgeons for anatomical accuracy and surgical considerations. Imaging of Claw, Beating, and Frankenstein TAHs revealed internal motors, circuit boards, and speakers. Gummy TAH was ranked favorite TAH for tactile realism, while Frankenstein TAH had the most favorable audible/visual indicators, including an illuminated Jacob's Ladder. Beating TAH demonstrated superior pulsatile hemodynamic performance compared to Claw TAH (16mL vs 1.3mL stroke volume). Light Up TAH and Gummy TAH functioned only as passive compliance chambers. Cute TAH rapidly exsanguinated due to its porosity (-3.0 L/min flow). These TAHs demonstrated a wide range of anatomical accuracy, surgeon appeal, unique features, and hemodynamic performance. While Claw TAH and Beating TAH successfully generated a modicum of pulsatility, we recommend the clinical community continue to support pre-clinical development of emerging or use of clinically-approved TAHs.


Asunto(s)
Corazón Artificial , Hemodinámica , Hemodinámica/fisiología , Humanos
8.
Artículo en Inglés | MEDLINE | ID: mdl-39037566

RESUMEN

PURPOSE: CoRISMA MCS Systems Inc (Hamden CT) is developing an innovative mechanical circulatory support system (CMCS) as a durable therapeutic option for heart failure (HF) patients. The CMCS system is comprised of an axial flow pump, non-contacting hydrodynamic bearings, and integrated DC motor designed to be fully implantable in a left atrial (LA) to aortic (Ao) configuration; this unloading strategy may be particularly beneficial for HF patients with preserved ejection fraction (HFpEF). The small (5.5 cm3), lightweight (20 g), and low power (5-7 W) device design should allow for a less invasive off-pump implant. We present early-stage engineering development and testing of the prototype CoRISMA pumps. METHODS: Computational fluid dynamics (CFD) modeling was performed to evaluate flow and shear in two impeller (3 blades, 0.5 mm thickness, 8.9 mm diameter, 0.15 mm gap, polished titanium) and diffusor (5 blades, polished titanium) candidate designs. Test apparatuses were custom built to expedite development of the impeller/diffuser designs and iteratively refine the CFD models. Two candidate impeller/diffusor designs were fabricated and tested in each of the two test apparatuses (n = 4 impeller/diffuser + test fixture configurations) in static mock flow loops (hydrodynamic H-Q curves, 3.5 cP glycerol solution at 37 °C), and in dynamic mock flow loops (hemodynamics, 3.5 cP glycerol solution at 37 °C) tuned to HF conditions (mean aortic pressure 50 mmHg, central venous pressure 15 mmHg, aortic flow 3.0 L/min, and heart rate 80 bpm). RESULTS: CFD predicted flows of 4.56 L/min and 4.82 L/min at 100 mmHg for impellers/diffusers 1 and 2, respectively. Impeller 2 required less torque to generate a 6% increase in fluidic flow, and the diffuser had a larger area of high pressure, indicative of lower friction, which likely contributed to the increased efficiency. Experimental testing for all four configurations in the static and dynamic mock loops met performance metrics as evidenced by generating 4.0-4.5 L/min flow against 70-76 mmHg pressure at 25,000 rpm and restoring hemodynamics in the dynamic mock flow loop (MAP = 80 mmHg, CVP = 0 mmHg, total flow = 5.5 L/min) from baseline simulated HF test conditions. CONCLUSION: These results demonstrate proof-of-concept of the early engineering design and performance of the prototype CoRISMA pumps. Engineering specifications, challenges observed, and proposed solutions for the next design iteration were identified for the continued development of an effective, reliable, and safe LA-to-Ao CMCS system for HF patients. Current design plans are underway for incorporating a wireless energy transfer system for communication and power, eliminating the need for and complications associated with an external driveline, to achieve a fully-implantable system.

9.
bioRxiv ; 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38659908

RESUMEN

Mechanical unloading and circulatory support with left ventricular assist devices (LVADs) mediate significant myocardial improvement in a subset of advanced heart failure (HF) patients. The clinical and biological phenomena associated with cardiac recovery are under intensive investigation. Left ventricular (LV) apical tissue, alongside clinical data, were collected from HF patients at the time of LVAD implantation (n=208). RNA was isolated and mRNA transcripts were identified through RNA sequencing and confirmed with RT-qPCR. To our knowledge this is the first study to combine transcriptomic and clinical data to derive predictors of myocardial recovery. We used a bioinformatic approach to integrate 59 clinical variables and 22,373 mRNA transcripts at the time of LVAD implantation for the prediction of post-LVAD myocardial recovery defined as LV ejection fraction (LVEF) ≥40% and LV end-diastolic diameter (LVEDD) ≤5.9cm, as well as functional and structural LV improvement independently by using LVEF and LVEDD as continuous variables, respectively. To substantiate the predicted variables, we used a multi-model approach with logistic and linear regressions. Combining RNA and clinical data resulted in a gradient boosted model with 80 features achieving an AUC of 0.731±0.15 for predicting myocardial recovery. Variables associated with myocardial recovery from a clinical standpoint included HF duration, pre-LVAD LVEF, LVEDD, and HF pharmacologic therapy, and LRRN4CL (ligand binding and programmed cell death) from a biological standpoint. Our findings could have diagnostic, prognostic, and therapeutic implications for advanced HF patients, and inform the care of the broader HF population.

10.
Pediatr Crit Care Med ; 14(9): e424-37, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24108116

RESUMEN

OBJECTIVES: Despite progress with adult ventricular assist devices, limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, extracorporeal membrane oxygenation was compared to intra-aortic balloon pump, pulsatile-flow ventricular assist device, or continuous-flow ventricular assist device support in a pediatric heart failure model. DESIGN: Experimental. SETTING: Large animal laboratory operating room. SUBJECTS: Yorkshire piglets (n = 47; 11.7 ± 2.6 kg). INTERVENTIONS: In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS AND MAIN RESULTS: Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired Student t tests compared baseline and heart failure conditions. One-way repeated-measures analysis of variance compared heart failure, device support mode(s), and extracorporeal membrane oxygenation. Statistically significant (p < 0.05) findings included 1) an improved left ventricular blood supply/demand ratio during pulsatile-flow ventricular assist device, continuous-flow ventricular assist device, and extracorporeal membrane oxygenation but not intra-aortic balloon pump support, 2) an improved global myocardial blood supply/demand ratio during pulsatile-flow ventricular assist device and continuous-flow ventricular assist device but not intra-aortic balloon pump or extracorporeal membrane oxygenation support, and 3) diminished pulsatility during extracorporeal membrane oxygenation and continuous-flow ventricular assist device but not intra-aortic balloon pump and pulsatile-flow ventricular assist device support. A profile of systems-based responses was established for each type of support. CONCLUSIONS: Each type of pediatric ventricular assist device provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hemodinámica , Contrapulsador Intraaórtico , Animales , Aorta/fisiopatología , Arterias Carótidas/fisiopatología , Vasos Coronarios/fisiopatología , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Consumo de Oxígeno , Flujo Pulsátil/fisiología , Circulación Renal , Porcinos
11.
Artif Organs ; 37(12): E202-14, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23876076

RESUMEN

Ventricular assist devices (VADs) have emerged as a successful treatment option for advanced heart failure. The objective of this study was to develop a clinically relevant model of chronic ischemic cardiomyopathy to investigate functional, histological, and molecular changes during mechanical circulatory support. In calves (n = 17, 94 ± 7 kg), 90 µm microspheres were injected percutaneously into the left coronary artery. Serial echocardiography was performed weekly to evaluate cardiac function. Sixty days after coronary microembolization, a terminal study was performed via thoracotomy to measure hemodynamics. Regional myocardial and end-organ blood flows were quantified with 15-µm fluorescent-labeled microspheres. Myocardial fibrosis, myocyte size, and myocardial apoptosis were quantified with histological stains. Eleven animals survived coronary microembolization and exhibited clinical and statistically significant echocardiographic and hemodynamic signs of severe systolic dysfunction. Statistically significant decreases in regional myocardial blood flow and increases in myocardial fibrosis, myocyte size, total myocardial apoptosis, and cardiac myocyte-specific apoptosis were observed. End-organ hypoperfusion was observed. Coronary microembolization induced stable and reproducible chronic left ventricular failure in calves. The anatomical size and physiology of the bovine heart and thorax are appropriate to study novel interventions for the clinical management of heart failure. This model is an appropriate physiological substrate in which to test VAD and adjunctive biological therapies.


Asunto(s)
Cardiomiopatías/terapia , Corazón Auxiliar , Isquemia Miocárdica/complicaciones , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Animales , Apoptosis , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Bovinos , Enfermedad Crónica , Circulación Coronaria , Modelos Animales de Enfermedad , Fibrosis , Hemodinámica , Humanos , Isquemia Miocárdica/fisiopatología , Miocardio/patología , Diseño de Prótesis , Especificidad de la Especie , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
12.
ASAIO J ; 69(6): 519-526, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36763814

RESUMEN

RT Cardiac Systems (RTCS, Raleigh, NC) is developing an intravascular percutaneous mechanical circulatory support (pMCS) device drive system for use during high-risk percutaneous coronary intervention and emergent cardiogenic shock. The proprietary pMCS device (US patent 10,780,206) consists of a miniaturized axial flow pump with an integrated motor connected via a short flexible drive system. This novel flexible drive system creates a flexible pump that is advantageous for percutaneous placement and conforming to anatomy. This design also has the benefit of not requiring a continuous external lubrication source. In this article, we present engineering development and feasibility testing of the prototype pMCS system. Computational fluid dynamics (CFD) modeling was performed to evaluate candidate blade set designs (impeller leading and trailing edges, diffuser) and predict hydrodynamic performance and hemolysis risk. Bench testing of candidate lip seal designs (radial interference, durometer, and seal angle) was evaluated for leak rate. Two 16Fr prototype devices were then fabricated and tested in a static mock flow loop. Experimental testing demonstrated 3 L/min flow against 110 mmHg and 4 L/min flow against 80 mmHg, which matched the CFD-predicted hydrodynamic performance. These results demonstrate feasibility of the engineering design and performance of the prototype devices.


Asunto(s)
Corazón Auxiliar , Intervención Coronaria Percutánea , Humanos , Estudios de Factibilidad , Corazón Auxiliar/efectos adversos , Hemólisis , Choque Cardiogénico/cirugía , Diseño de Equipo
14.
J Surg Res ; 172(1): e55-60, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22079842

RESUMEN

BACKGROUND: The Matrigel assay provides a versatile platform to examine vessel growth. Similarly, the microsphere method is used extensively in laboratory animals to measure tissue-specific blood flow. However, microsphere models have not been used with Matrigel to study angiogenesis in live animals. The goal of this study was to develop a novel technique to directly measure blood flow with microspheres in vessels grown in Matrigel in vivo. METHODS: In calves (n = 10, 110 ± 5 kg), 5 mL of Matrigel was injected subcutaneously. After 10 d, a percutaneous cardiac catheterization was performed. Fluorescent-labeled 15 µm microspheres were injected into the left ventricular chamber to distribute throughout the body based on systemic blood flow patterns. Afterwards, Matrigel plugs were removed, and animals were recovered. Flow cytometry was used to count microspheres and quantify blood flow within the plug. FITC-conjugated isolectin-B4 staining was performed to quantify Matrigel capillary density. Flow cytometry was performed to quantify circulating plasma CD34(+) cells. Linear regressions were used to determine relationships between Matrigel blood flow, Matrigel capillary density, and plasma CD34(+) cells. RESULTS: Over 10 d, small-caliber vessels grew into subcutaneous Matrigel plugs. Microspheres lodged throughout the plug and indicated that newly grown vessels in the Matrigel were functional and able to accommodate blood flow. Modest associations between Matrigel blood flow, Matrigel capillary density, and circulating plasma CD34(+) cells were noted. CONCLUSION: This method provides a novel and cost-effective technique to measure blood flow within vessels grown in Matrigel in vivo.


Asunto(s)
Colágeno , Laminina , Microesferas , Microvasos/fisiología , Neovascularización Fisiológica/fisiología , Proteoglicanos , Flujo Sanguíneo Regional/fisiología , Animales , Antígenos CD34/metabolismo , Capilares/fisiología , Bovinos , Combinación de Medicamentos , Citometría de Flujo , Masculino , Células Plasmáticas/citología , Células Plasmáticas/inmunología
15.
Artif Organs ; 36(8): 677-82, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22882437

RESUMEN

Mechanical circulatory assist devices that provide temporary support in heart failure patients are needed to enable recovery or provide a bridge to decision. Minimizing risk of blood damage (i.e., hemolysis) with these devices is critical, especially if the length of support needs to be extended. Hematologic responses of the RotaFlow (Maquet) and CentriMag (Thoratec) temporary support devices were characterized in an in vitro feasibility study. Paired static mock flow loops primed with fresh bovine blood (700 mL, hematocrit [Hct] = 25 ± 3%, heparin titrated for activated clotting time >300 s) pooled from a single-source donor were used to test hematologic responses to RotaFlow (n = 2) and CentriMag (n = 2) simultaneously. Pump differential pressures, temperature, and flow were maintained at 250 ± 10 mm Hg, 25 ± 2°C, and 4.2 ± 0.25 L/min, respectively. Blood samples (3 mL) were collected at 0, 60, 120, 180, 240, 300, and 360 min after starting pumps in accordance with recommended Food and Drug Administration and American Society for Testing and Materials guidelines. The CentriMag operated at a higher average pump speed (3425 rpm) than the RotaFlow (3000 rpm) while maintaining similar constant flow rates (4.2 L/min). Hematologic indicators of blood trauma (hemoglobin, Hct, platelet count, plasma free hemoglobin, and white blood cell) for all measured time points as well as normalized and modified indices of hemolysis were similar (RotaFlow: normalized index of hemolysis [NIH] = 0.021 ± 0.003 g/100 L, modified index of hemolysis [MIH] = 3.28 ± 0.52 mg/mg compared to CentriMag: NIH = 0.041 ± 0.010 g/100 L, MIH = 6.08 ± 1.45 mg/mg). In this feasibility study, the blood trauma performance of the RotaFlow was similar or better than the CentriMag device under clinically equivalent, worst-case test conditions. The RotaFlow device may be a more cost-effective alternative to the CentriMag.


Asunto(s)
Circulación Asistida/efectos adversos , Circulación Asistida/instrumentación , Hemólisis , Animales , Bovinos , Diseño de Equipo , Hematócrito , Humanos , Recuento de Leucocitos , Proyectos Piloto , Recuento de Plaquetas
16.
Artif Organs ; 36(7): 600-6, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22591355

RESUMEN

A counterpulsation device (Symphony) is being developed to provide long-term circulatory support for advanced heart failure (HF) patients. In acute animal experiments, flow waveform patterns in the aortic, carotid, and coronary arteries were compared during Symphony and intra-aortic balloon pump (IABP) support. Human data were examined for similarities. The 30-mL Symphony was compared to a 40-mL IABP in calves with cardiac dysfunction (80-100 kg, n = 8). Aortic pressures and aortic, carotid, and coronary artery flows were simultaneously recorded at baseline (devices off) and during 1:1 and 1:2 support. Forward, retrograde, and mean flows were calculated and compared for each test condition. Findings were also compared to aortic flow measurements recorded in HF patients (n = 21) supported by 40-mL IABP. IABP caused significant retrograde flows in the aorta, coronary (IABP: -24 ± 8 mL/min, Symphony: -6 ± 2 mL/min, baseline: -2 ± 1 mL/min, P < 0.05), and carotid arteries (IABP: -30 ± 5 mL/min, Symphony: -0 ± 0 mL/min, baseline: -0 ± 0 L/min, P < 0.05) during ventricular systole compared to the Symphony. IABP support produced higher diastolic pressure and flow augmentation compared to Symphony. Due to retrograde flows during IABP support, Symphony provided higher overall coronary, carotid, and aortic flows. Similar reduction in total aortic flows due to retrograde flow was observed in HF patients during IABP support. Counterpulsation with an IABP via aortic volume displacement produces retrograde flows during rapid balloon deflation that reduces total flow. Counterpulsation with Symphony via volume removal eliminates retrograde flow and improves total flow more than that achieved with IABP. The Symphony may provide long-term hemodynamic benefits in HF patients.


Asunto(s)
Contrapulsación/instrumentación , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Hemodinámica , Contrapulsador Intraaórtico/instrumentación , Animales , Aorta/fisiología , Aorta/fisiopatología , Arterias Carótidas/fisiología , Arterias Carótidas/fisiopatología , Bovinos , Vasos Coronarios/fisiología , Vasos Coronarios/fisiopatología , Contrapulsación/efectos adversos , Corazón Auxiliar/efectos adversos , Humanos , Contrapulsador Intraaórtico/efectos adversos , Masculino , Estudios Retrospectivos
17.
Artif Organs ; 36(8): 731-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22882443

RESUMEN

Heart failure (HF) is increasing worldwide and represents a major burden in terms of health care resources and costs. Despite advances in medical care, prognosis with HF remains poor, especially in advanced stages. The large patient population with advanced HF and the limited number of donor organs stimulated the development of mechanical circulatory support (MCS) devices as a bridge to transplant and for destination therapy. However, MCS devices require a major operative intervention, cardiopulmonary bypass, and blood component exposure, which have been associated with significant adverse event rates, and long recovery periods. Miniaturization of MCS devices and the development of an efficient and reliable transcutaneous energy transfer system may provide the vehicle to overcome these limitations and usher in a new clinical paradigm in heart failure therapy by enabling less invasive beating heart surgical procedures for implantation, reduce cost, and improve patient outcomes and quality of life. Further, it is anticipated that future ventricular assist device technology will allow for a much wider application of the therapy in the treatment of heart failure including its use for myocardial recovery and as a platform for support for cell therapy in addition to permanent long-term support.


Asunto(s)
Circulación Asistida/instrumentación , Miniaturización , Animales , Catéteres , Diseño de Equipo , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Humanos
18.
PLoS One ; 17(5): e0266822, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35544516

RESUMEN

Inspired Therapeutics (Merritt Island, FL) is developing a mechanical circulatory support (MCS) system designed as a single driver with interchangeable, extracorporeal, magnetically levitated pumps. The NeoMate system design features an integrated centrifugal rotary pump, motor, and controller that will be housed in a single compact unit. Conceptually, the primary innovation of this technology will be the combination of disposable, low-cost pumps for use with a single, multi-functional, universal controller to support multiple pediatric cardiopulmonary indications. In response to the paucity of clinically available pediatric devices, Inspired Therapeutics is specifically targeting the underserved neonate and infant heart failure (HF) patient population first. In this article, we present the development of the prototype Inspired Therapeutics NeoMate System for pediatric left ventricular assist device (LVAD) support, and feasibility testing in static mock flow loops (H-Q curves), dynamic mock flow loops (hemodynamics), and in an acute healthy ovine model (hemodynamics and clinical applicability). The resultant hydrodynamic and hemodynamic data demonstrated the ability of this prototype pediatric LVAD and universal controller to function over a range of rotary pump speeds (500-6000 RPM), to provide pump flow rates of up to 2.6 L/min, and to volume unload the left ventricle in acute animals. Key engineering challenges observed and proposed solutions for the next design iteration are also presented.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Animales , Niño , Diseño de Equipo , Estudios de Factibilidad , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Humanos , Recién Nacido , Ovinos
19.
Cardiovasc Eng Technol ; 13(2): 307-317, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34518953

RESUMEN

PURPOSE: Despite the availability of first-generation extracorporeal mechanical circulatory support (MCS) systems that are widely used throughout the world, there is a need for the next generation of smaller, more portable devices (designed without cables and a minimal number of connectors) that can be used in all in-hospital and transport settings to support patients in heart failure. Moreover, a system that can be universally used for all indications for use including cardiopulmonary bypass (CPB), uni- or biventricular support (VAD), extracorporeal membrane oxygenation (ECMO) and respiratory assist that is suitable for use for adult, neonate, and pediatric patients is desirable. Providing a single, well designed, universal technology could reduce the incidence of human errors by limiting the need for training of hospital staff on a single system for a variety of indications throughout the hospital rather than having to train on multiple complex systems. The objective of this manuscript is to describe preliminary research to develop the first prototype pump for use as a ventricular assist device for pediatric patients with the Inspired Universal MCS technology. The Inspired VAD Universal System is an innovative extracorporeal blood pumping system utilizing novel MagLev technology in a single portable integrated motor/controller unit which can power a variety of different disposable pump modules intended for neonate, pediatric, and adult ventricular and respiratory assistance. METHODS: A prototype of the Inspired Pediatric VAD was constructed to determine the hemodynamic requirements for pediatric applications. The magnitude/range of hydraulic torque of the internal impeller was quantified. The hydrodynamic performance of the prototype pump was benchmarked using a static mock flow loop model containing a heated blood analogue solution to test the pump over a range of rotational speeds (500-6000 RPM), flow rates (0-3.5 L/min), and pressures (0 to ~ 420 mmHg). The device was initially powered by a shaft-driven DC motor in lieu of a full MagLev design, which was also used to calculate the fluid torque acting on the impeller. RESULTS: The pediatric VAD produced flows as high as 4.27 L/min against a pressure of 127 mmHg at 6000 RPM and the generated pressure and flow values fell within the desired design specifications. CONCLUSIONS: The empirically determined performance and torque values establish the requirements for the magnetically levitated motor design to be used in the Inspired Universal MagLev System. This next step in our research and development is to fabricate a fully integrated and functional magnetically levitated pump, motor and controller system that meets the product requirement specifications and achieves a state of readiness for acute ovine animal studies to verify safety and performance of the system.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Animales , Niño , Diseño de Equipo , Insuficiencia Cardíaca/terapia , Hemodinámica , Humanos , Ovinos , Torque
20.
Cardiovasc Eng Technol ; 13(4): 624-637, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35013917

RESUMEN

PURPOSE: Pediatric heart failure patients remain in critical need of a dedicated mechanical circulatory support (MCS) solution as development efforts for specific pediatric devices continue to fall behind those for the adult population. The Inspired Pediatric VAD is being developed as a pediatric specific MCS solution to provide up to 30-days of circulatory or respiratory support in a compact modular package that could allow for patient ambulation during treatment. METHODS: Hydrodynamic performance (flows, pressures), impeller/rotor mechanical properties (torques, forces), and flow shear stress and residence time distributions of the latest design version, Inspired Pediatric VAD V3, were numerically predicted and investigated using computational fluid dynamics (CFD) software (SolidWorks Flow Simulator). RESULTS: Hydrodynamic performance was numerically predicted, indicating no change in flow and pressure head compared to the previous device design (V2), while displaying increased impeller/rotor torques and translation forces enabled by improved geometry. Shear stress and flow residence time volumetric distributions are presented over a range of pump rotational speeds and flow rates. At the lowest pump operating point (3000 RPM, 0.50 L/min, 75 mmHg), 79% of the pump volume was in the shear stress range of 0-10 Pa with < 1% of the volume in the critical range of 150-1000 Pa for blood damage. At higher speed and flow (5000 RPM, 3.50 L/min, 176 mmHg), 65% of the volume resided in the 0-10 Pa range compared to 2.3% at 150-1000 Pa. CONCLUSIONS: The initial computational characterization of the Inspired Pediatric VAD V3 is encouraging and future work will include device prototype testing in a mock circulatory loop and acute large animal model.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Animales , Diseño de Equipo , Insuficiencia Cardíaca/terapia , Humanos , Hidrodinámica , Presión , Estrés Mecánico