RESUMEN
BACKGROUND: Cardiac surgery triggers a strong inflammatory reaction, which carries significant clinical consequences. Corticosteroids have been suggested as a potential perioperative strategy to reduce inflammation and help prevent postoperative complications. However, the safety and effectiveness of perioperative corticosteroid use in adult cardiac surgery is uncertain. This is an update of the 2011 review with 18 studies added. OBJECTIVES: Primary objective: to estimate the effects of prophylactic corticosteroid use in adults undergoing cardiac surgery with cardiopulmonary bypass on the: - co-primary endpoints of mortality, myocardial complications, and pulmonary complications; and - secondary outcomes including atrial fibrillation, infection, organ injury, known complications of steroid therapy, prolonged mechanical ventilation, prolonged postoperative stay, and cost-effectiveness. SECONDARY OBJECTIVE: to explore the role of characteristics of the study cohort and specific features of the intervention in determining the treatment effects via a series of prespecified subgroup analyses. SEARCH METHODS: We used standard, extensive Cochrane search methods to identify randomised studies assessing the effect of corticosteroids in adult cardiac surgery. The latest searches were performed on 14 October 2022. SELECTION CRITERIA: We included randomised controlled trials in adults (over 18 years, either with a diagnosis of coronary artery disease or cardiac valve disease, or who were candidates for cardiac surgery with the use of cardiopulmonary bypass), comparing corticosteroids with no treatments. There were no restrictions with respect to length of the follow-up period. All selected studies qualified for pooling of results for one or more endpoints. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were all-cause mortality, and cardiac and pulmonary complications. Secondary outcomes were infectious complications, gastrointestinal bleeding, occurrence of new post-surgery atrial fibrillation, re-thoracotomy for bleeding, neurological complications, renal failure, inotropic support, postoperative bleeding, mechanical ventilation time, length of stays in the intensive care unit (ICU) and hospital, patient quality of life, and cost-effectiveness. We used GRADE to assess the certainty of evidence for each outcome. MAIN RESULTS: This updated review includes 72 randomised trials with 17,282 participants (all 72 trials with 16,962 participants were included in data synthesis). Four trials (6%) were considered at low risk of bias in all the domains. The median age of participants included in the studies was 62.9 years. Study populations consisted mainly (89%) of low-risk, first-time coronary artery bypass grafting (CABG) or valve surgery. The use of perioperative corticosteroids may result in little to no difference in all-cause mortality (risk with corticosteroids: 25 to 36 per 1000 versus 33 per 1000 with placebo or no treatment; risk ratio (RR) 0.90, 95% confidence interval (CI) 0.75 to 1.07; 25 studies, 14,940 participants; low-certainty evidence). Corticosteroids may increase the risk of myocardial complications (68 to 86 per 1000) compared with placebo or no treatment (66 per 1000; RR 1.16, 95% CI 1.04 to 1.31; 25 studies, 14,766 participants; low-certainty evidence), and may reduce the risk of pulmonary complications (risk with corticosteroids: 61 to 77 per 1000 versus 78 per 1000 with placebo/no treatment; RR 0.88, 0.78 to 0.99; 18 studies, 13,549 participants; low-certainty evidence). Analyses of secondary endpoints showed that corticosteroids may reduce the incidence of infectious complications (risk with corticosteroids: 94 to 113 per 1000 versus 123 per 1000 with placebo/no treatment; RR 0.84, 95% CI 0.76 to 0.92; 28 studies, 14,771 participants; low-certainty evidence). Corticosteroids may result in little to no difference in incidence of gastrointestinal bleeding (risk with corticosteroids: 9 to 17 per 1000 versus 10 per 1000 with placebo/no treatment; RR 1.21, 95% CI 0.87 to 1.67; 6 studies, 12,533 participants; low-certainty evidence) and renal failure (risk with corticosteroids: 23 to 35 per 1000 versus 34 per 1000 with placebo/no treatment; RR 0.84, 95% CI 0.69 to 1.02; 13 studies, 12,799; low-certainty evidence). Corticosteroids may reduce the length of hospital stay, but the evidence is very uncertain (-0.5 days, 0.97 to 0.04 fewer days of length of hospital stay compared with placebo/no treatment; 25 studies, 1841 participants; very low-certainty evidence). The results from the two largest trials included in the review possibly skew the overall findings from the meta-analysis. AUTHORS' CONCLUSIONS: A systematic review of trials evaluating the organ protective effects of corticosteroids in cardiac surgery demonstrated little or no treatment effect on mortality, gastrointestinal bleeding, and renal failure. There were opposing treatment effects on cardiac and pulmonary complications, with evidence that corticosteroids may increase cardiac complications but reduce pulmonary complications; however, the level of certainty for these estimates was low. There were minor benefits from corticosteroid therapy for infectious complications, but the evidence on hospital length of stay was very uncertain. The inconsistent treatment effects across different outcomes and the limited data on high-risk groups reduced the applicability of the findings. Further research should explore the role of these drugs in specific, vulnerable cohorts.
Asunto(s)
Corticoesteroides , Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Complicaciones Posoperatorias , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Puente Cardiopulmonar/efectos adversos , Puente Cardiopulmonar/mortalidad , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/mortalidad , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Corticoesteroides/uso terapéutico , Corticoesteroides/efectos adversos , Sesgo , Adulto , Tiempo de Internación , Causas de Muerte , Fibrilación Atrial/prevención & control , Fibrilación Atrial/mortalidad , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/mortalidad , Respiración Artificial/efectos adversos , Respiración Artificial/estadística & datos numéricos , Persona de Mediana EdadRESUMEN
For whole-body sway patterns, a compound motor response following an external stimulus may comprise reflexes, postural adjustments (anticipatory or compensatory), and voluntary muscular activity. Responses to equilibrium destabilization may depend on both motor set and a subject`s expectation of the disturbing stimulus. To disentangle these influences on lower limb responses, we studied a model in which subjects (n = 14) were suspended in the air, without foot support, and performed a fast unilateral wrist extension (WE) in response to a passive knee flexion (KF) delivered by a robot. To characterize the responses, electromyographic activity of rectus femoris and reactive leg torque was obtained bilaterally in a series of trials, with or without the requirement of WE (motor set), and/or beforehand information about the upcoming velocity of KF (subject`s expectation). Some fast-velocity trials resulted in StartReact responses, which were used to subclassify leg responses. When subjects were uninformed about the upcoming KF, large rectus femoris responses concurred with a postural reaction in conditions without motor task, and with both postural reaction and postural adjustment when WE was required. WE in response to a low-volume acoustic signal elicited no postural adjustments. When subjects were informed about KF velocity and had to perform WE, large rectus femoris responses corresponded to anticipatory postural adjustment rather than postural reaction. In conclusion, when subjects are suspended in the air and have to respond with WE, the prepared motor set includes anticipatory postural adjustments if KF velocity is known, and additional postural reactions if KF velocity is unknown.
Asunto(s)
Postura , Muñeca , Humanos , Postura/fisiología , Electromiografía , Reflejo , Extremidad Inferior , Equilibrio Postural , Movimiento/fisiología , Músculo Esquelético/fisiologíaRESUMEN
OBJECTIVES: To investigate the effect of an audiovisual distraction system on the dose of remifentanil for perioperative sedation during transcatheter aortic valve implantation under monitored anesthesia care. DESIGN: Single-center prospective randomized nonblinded study. SETTING: Tertiary referral academic hospital. PARTICIPANTS: Ninety patients who underwent transfemoral transcatheter aortic valve implantation between July 2019 and July 2021. INTERVENTIONS: Patients were randomized to use either a novel audiovisual distraction system during the intervention (n = 45) or standard care without an audiovisual distraction system (n = 45). MEASUREMENTS AND MAIN RESULTS: Standardized questionnaires were given to each patient at admission and before and after the intervention to assess their levels of anxiety. Primary endpoints were the average and peak infusion rates of remifentanil. All patients were considered for the final analysis according to an intention-to-treat design. No relevant differences in pre- and postinterventional anxiety status were observed between the groups. Similarly, there were no significant differences in reported pain scores (p = 0.364). The average infusion rate (p = 0.028) and peak infusion rate (p = 0.025) of remifentanil were lower in the group with an audiovisual distraction system. CONCLUSIONS: Audiovisual distraction is a useful adjunct to reduce the dose of remifentanil under monitored anesthesia care during transcatheter aortic valve implantation. Larger studies are needed to evaluate potential positive effects on patient satisfaction, incidence of delirium, and possible economic benefits.
Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Estudios Prospectivos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Remifentanilo/administración & dosificación , Manejo del Dolor/métodos , Recursos Audiovisuales , Anestesia/métodosRESUMEN
BACKGROUND AND PURPOSE: Fatigue and cognitive difficulties are reported as the most frequently persistent symptoms in patients after mild SARS-CoV-2 infection. An extensive neurophysiological and neuropsychological assessment of such patients was performed focusing on motor cortex physiology and executive cognitive functions. METHODS: Sixty-seven patients complaining of fatigue and/or cognitive difficulties after resolution of mild SARS-CoV-2 infection were enrolled together with 22 healthy controls (HCs). Persistent clinical symptoms were investigated by means of a 16-item questionnaire. Fatigue, exertion, cognitive difficulties, mood and 'well-being' were evaluated through self-administered tools. Utilizing transcranial magnetic stimulation of the primary motor cortex (M1) resting motor threshold, motor evoked potential amplitude, cortical silent period duration, short-interval intracortical inhibition, intracortical facilitation, long-interval intracortical inhibition and short-latency afferent inhibition were evaluated. Global cognition and executive functions were assessed with screening tests. Attention was measured with computerized tasks. RESULTS: Post COVID-19 patients reported a mean of 4.9 persistent symptoms, high levels of fatigue, exertion, cognitive difficulties, low levels of well-being and reduced mental well-being. Compared to HCs, patients presented higher resting motor thresholds, lower motor evoked potential amplitudes and longer cortical silent periods, concurring with reduced M1 excitability. Long-interval intracortical inhibition and short-latency afferent inhibition were also impaired, indicating altered GABAB -ergic and cholinergic neurotransmission. Short-interval intracortical inhibition and intracortical facilitation were not affected. Patients also showed poorer global cognition and executive functions compared to HCs and a clear impairment in sustained and executive attention. CONCLUSIONS: Patients with fatigue and cognitive difficulties following mild COVID-19 present altered excitability and neurotransmission within M1 and deficits in executive functions and attention.
Asunto(s)
COVID-19 , Corteza Motora , COVID-19/complicaciones , Cognición , Potenciales Evocados Motores/fisiología , Fatiga/etiología , Humanos , Inhibición Neural/fisiología , SARS-CoV-2 , Estimulación Magnética TranscranealRESUMEN
Mitral annular calcification (MAC) complicates the management of mitral valve (MV) disease, regardless of its etiology. Strategies to address MV surgery in MAC include two main options with their own pros and cons; respect and resect strategy. Here, we present a case of minimally-invasive MV repair with partial annuloplasty in the management of noncircumferential MAC with respect to strategy. This technique may be an alternative option for rescuing high-risk patients without extensive decalcification.
Asunto(s)
Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/etiología , Calcinosis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del TratamientoRESUMEN
Transcatheter aortic valve replacement (TAVR) has already received the green light for high-, intermediate- and low-risk profiles and is an alternative for all patients regardless of age. It is clear that there has been a push towards the use of TAVR in younger and younger patients (<65 years), which has never been formally tested in randomized controlled trials but seems inevitable as TAVR technology makes steady progress. Lifetime management as a concept will set the tone in the field of the structural heart. Some subjects in this scenario arise, including the importance of optimized prosthetic hemodynamics for lifetime care; surgical procedures in the aortic root; management of structural valve degeneration with valve-in-valve procedures (TAVR-in-surgical aortic valve replacement [SAVR] and TAVR-in-TAVR) and redo SAVR; commissural alignment and cusp overlap for TAVR; the rise in the number of surgical procedures for TAVR explantation; and the renewed interest in the Ross procedure. This article reviews all these issues which will become commonplace during heart team meetings and preoperative conversations with patients in the coming years.
Asunto(s)
Enfermedad de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del TratamientoRESUMEN
Transcatheter mitral valve implantation (TMVI) has emerged as a less invasive approach potentially surmounting some of the current hurdles associated with transcatheter edge-to-edge repair and high-risk mitral valve surgery. In this review, we aimed to outline the main scenarios in the TMVI field, highlight current and upcoming devices, and describe challenges and clinical results. Finally, we briefly discuss the future perspectives for this emerging field and how TMVI might further advance the field of transcatheter treatments of mitral valve disease.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del TratamientoRESUMEN
Composite replacement of the aortic root and aortic valve is a valid surgical strategy in a case of annuloaortic ectasia. However, valve-sparing root replacement procedures have become the gold standard in cases with a morphologically intact or at least repairable aortic valve, and offer several advantages compared to conventional replacement techniques. Above all, the David procedure has become established as a well-known valve-sparing root replacement strategy with excellent short- and long-term outcomes, and it has been further applied to additional patient populations with characteristics like a bicuspid aortic valve or in the setting of acute type A aortic dissection. This narrative review offers an overview of the indications as well as the surgical steps of the T. David V procedure, and highlights important key points regarding the surgical feasibility and criteria of patient selection for valve-sparing root replacement.
RESUMEN
Over the past few decades, the field of minimally invasive cardiac surgery has significantly broadened. Novel surgical and endovascular techniques have been developed for the treatment of aortic valve pathologies. Surgical aortic valve replacement (SAVR) through a right antero-lateral (mini-)thoracotomy (RALT) has gained approval due to its limited postoperative trauma, faster rehabilitation and sufficient pain control. Nevertheless, SAVR RALT has not been adopted by a significant proportion of cardiac surgeons, due, in part, to its technical complexity and steep learning curve. In this review, we discuss the data for minimally invasive aortic valve surgery and describe our operative technique for SAVR RALT.
RESUMEN
There has been much debate concerning whether startling sensory stimuli can activate a fast-neural pathway for movement triggering (StartReact) which is different from that of voluntary movements. Activity in sternocleidomastoid (SCM) electromyogram is suggested to indicate activation of this pathway. We evaluated whether SCM activity can accurately identify trials which may differ in their neurophysiological triggering and assessed the use of cumulative distribution functions (CDFs) of reaction time (RT) data to identify trials with the shortest RTs for analysis. Using recent data sets from the StartReact literature, we examined the relationship between RT and SCM activity. We categorised data into short/longer RT bins using CDFs and used linear mixed-effects models to compare potential conclusions that can be drawn when categorising data on the basis of RT versus on the basis of SCM activity. The capacity of SCM to predict RT is task-specific, making it an unreliable indicator of distinct neurophysiological mechanisms. Classification of trials using CDFs is capable of capturing potential task- or muscle-related differences in triggering whilst avoiding the pitfalls of the traditional SCM activity-based classification method. We conclude that SCM activity is not always evident on trials that show the early triggering of movements seen in the StartReact phenomenon. We further propose that a more comprehensive analysis of data may be achieved through the inclusion of CDF analyses. These findings have implications for future research investigating movement triggering as well as for potential therapeutic applications of StartReact.
Asunto(s)
Movimiento , Reflejo de Sobresalto , Estimulación Acústica , Electromiografía , Músculos del Cuello , Tiempo de ReacciónRESUMEN
INTRODUCTION: The post-inhibition excitatory phase (E3) of the cutaneous silent period (CSP) is attributed to the resynchronization of motoneuron activity following the inhibitory period but there is also evidence that a somatosensory startle reflex may contribute to this phase. We hypothesized that the startle reflex component contained in E3 will decrease during vibration. METHODS: Sixteen healthy individuals were included in the study. CSP was recorded from slightly contracted right thenar muscles after painful index finger stimulation, before, during, and immediately after vibration. The values of the percentage change of E3 relative to pre-stimulus baseline (E3%) were compared before, during, and after vibration for each individual. RESULTS: There was a reduction in E3% during vibration and the values returned to normal immediately after vibration (153.1 ± 43.5%, 115.2 ± 30.2%, 154.9 ± 68.2%, respectively; p = 0.030). DISCUSSION: E3 is reduced during vibration in healthy individuals, presumably due to suppression of a reflex component, which is superimposed upon the known resynchronization of motoneurons.
Asunto(s)
Mano , Vibración , Estimulación Eléctrica , Electromiografía , Humanos , Neuronas Motoras , Músculo Esquelético , ReflejoRESUMEN
BACKGROUND AND AIM OF THE STUDY: The objective was to evaluate whether there is a decisive time interval for patients to undergo surgery and to analyze if a rapid response in acute aortic dissection type A (AADA) affects patient selection. METHODS: In 283 patients undergoing surgery for AADA, median time from onset of initial symptoms to skin incision was 6.9 hours (interquartile range [IQR], 5.0-11.7 hours). Patients were divided into three groups according to median time point of surgery (median ± 3 hours, i.e., 4-10; < 4; and >10 hours). RESULTS: Almost 50% of patients presented in a critical preoperative state at hospital admission. Subanalysis identified patients being operated within 4 hours as an exclusive high-risk cohort (higher rates of preoperative neurologic dysfunction, tamponade, and cardiopulmonary resuscitation). Patients undergoing surgery between 4 and 10 hours showed a significantly better long-term survival (p = 0.021). Surgery within this time interval had a clear protective effect on 30-day mortality (odds ratio [OR]: 0.448. 95% confidence interval [CI]: 0.219-0.915). High age (OR: 1.037; 95% CI: 1.008-1.067), preoperative malperfusion syndrome (OR: 2.802; 95% CI: 1.351-5.811), and preoperative tamponade (OR: 2.621; 95% CI: 1.171-5.866) were factors predicting 30-day mortality. CONCLUSION: Rapid response in AADA interacts with the natural course of the disease resulting in an overrepresentation of critical patients. While the cohort below 4 hours represents the high-risk patients, time from symptom onset to initiation of surgery should not exceed 10 hours.
Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Tiempo de Tratamiento , Procedimientos Quirúrgicos Vasculares , Enfermedad Aguda , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Toma de Decisiones Clínicas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidadRESUMEN
Implantable left ventricular assist devices (durable LVADs) have dramatically improved mortality and morbidity in patients with advanced heart failure. Originally designed as a bridge or candidacy to heart transplantation, the indications extend toward permanent support and palliation. Modern durable continuous flow LVADs are small, commercially available, and allow for different surgical approaches to a wide range of patients with various cardiac pathologies. We will review different surgical implantation techniques of modern continuous flow LVADs, as well as specific aspects of preoperative patient evaluation and planning.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos , HumanosRESUMEN
Acute type A aortic dissection (ATAAD) is a life-threatening event that requires immediate surgical treatment. Improvements in surgical treatment, graft technology, organ protection and imaging techniques have led to improved clinical outcomes. Individualized treatment concepts have emerged based on more advanced planning tools that allow for a tailored approach even in complex situations such as multi-level malperfusion. This review provides an overview of the current surgical treatment of ATAAD, focusing on new disease classifications, preoperative computed tomography angiography (CTA) assessment, new prosthesis and stent technologies, and organ-protection strategies.
Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Enfermedad Aguda , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Humanos , Estudios Retrospectivos , Stents , Resultado del TratamientoRESUMEN
The two current strategies for robotic-assisted, surgical myocardial revascularization are minimally invasive direct coronary artery bypass (MIDCAB) and totally endoscopic coronary artery bypass grafting (TECAB). We discuss the rationale underlying the benefits of robotic assistance in surgical myocardial revascularization, and detail the technical steps to safely and effectively perform these two procedures.
Asunto(s)
Enfermedad de la Arteria Coronaria , Procedimientos Quirúrgicos Robotizados , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Revascularización Miocárdica , Resultado del TratamientoRESUMEN
Transcatheter repair systems are becoming increasingly popular as a potential solution for high-risk and inoperable patients with mitral regurgitation. The cardioband (Edwards Lifesciences, Irvine, California) is a transcatheter direct annuloplasty device, based on the concept of an undersized ring annuloplasty. We report a case of minimally invasive surgical explantation of a failed cardioband device 21 months after its implantation. Intraoperatively, it was found that three anchors of the cardioband device were detached from the posterior annulus at P2. In this report, a "cut and unscrew" technique with some tips and tricks is presented for the removal of the device.
Asunto(s)
Cateterismo Cardíaco/métodos , Remoción de Dispositivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Femenino , HumanosRESUMEN
Less-invasive techniques for cardiothoracic surgical procedures are designed to limit surgical trauma, but the technical requirements and preoperative planning are more demanding than those for conventional sternotomy. Patient selection, interdisciplinary collaboration, and surgical skills are key factors for procedural success. Aortic valve replacement is frequently performed through an upper hemisternotomy, but the right anterior minithoracotomy represents an even less traumatic, technical advancement. Preoperative assessment of the ascending aorta in relation to the sternum is mandatory to select patients and the intercostal access site. This description of the surgical technique focuses on the specific procedural details including the obligatory planning with computed tomography and our cannulation strategy. We also sought to define the anatomical ascending aorta-sternal relationship, as it is of utmost importance in preoperative computed tomographic planning.
Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Toracotomía , Resultado del TratamientoRESUMEN
BACKGROUND: The aim of this study was to evaluate the impact of transcatheter aortic valve implantation (TAVI) on mitral valve geometry and function. METHODS: Eighty-four patients underwent TAVI. Forty-four (52%) patients received a balloon-expandable valve and 40 (48%) were implanted with a self-expandable valve. All patients underwent three-dimensional-volumetric transesophageal echocardiography of the mitral valve before and immediately after TAVI. A dedicated software was used for assisted semiautomatic measurement of mitral annular geometry. RESULTS: During systole, the anterior to posterior (AP) diameter was significantly reduced after the procedure (3.4 ± 0.5 cm vs 3.2 ± 0.5 cm; P < .05). The mitral annular area (10.8 ± 2.8cm2 vs 9.9 ± 2.6cm2 ; P < .05) as well as the tenting area (1.6 ± 0.7 cm2 vs 1.2 ± 0.6 cm2 ; P < .001) measured at mid-systole were reduced after TAVI. Diastolic measures were similar. Patients treated with balloon-expandable valves showed a significantly larger reduction in the AP diameter compared to self-expandable valves (-0.25 cm vs -0.11 cm; P < .05). The reduction of the annular area was higher in the balloon-expandable group (-1.2 ± 1.59 vs -0.22 ± 1.41; P < .05). Grade of mitral regurgitation did improve or remained stable after TAVI. CONCLUSION: TAVI significantly impacts the mitral valve and mitral annular geometry and morphology. The choice of the prosthesis (balloon- vs self-expandable) may be relevant for those changes.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del TratamientoRESUMEN
BACKGROUND: Acute type A aortic dissection (ATAAD) is a surgical emergency with high rates of morbidity and mortality. The treatment of ATAAD is highly individualized and mainly depends on anatomical and technical factors. Great efforts to reduce the time to diagnosis and technological innovations have led to improved surgical results with a lower rate of dissection-related reoperations during long-term follow up. The aim of this article is to introduce a novel hybrid device for the treatment of DeBakey I acute aortic dissection. CONCEPT: A non-covered hybrid stent from Ascyrus Medical (Boca Raton, FL, USA) aims to improve the current standard of care, without increasing technical complexity or device-related complications. The AMDS (Ascyrus Medical Dissection Stent) prolongs the hemiarch operation by only a few minutes, does not need endovascular skills to be deployed, and provides an anatomical and "haemodynamic" correction. The device is intended to reduce perfusion of the false lumen by sealing the distal anastomosis, and to restore distal perfusion of the true lumen. Obliteration of the false lumen at the distal anastomosis is likely to reduce aortic enlargement and the need for reoperations, mainly driven by a low-flow state and pressure reduction, which promote thrombosis. CONCLUSIONS: The AMDS provides a new concept to treat acute aortic dissection by moving the focus from resecting the dissected tissue to restoring adequate true-lumen flow and sealing the false lumen at the distal anastomosis. With a high rate of procedural success, AMDS represents a safe, reproducible and promising solution to treat DeBakey I aortic dissections.
Asunto(s)
Disección Aórtica , Aneurisma de la Aorta Torácica , Prótesis Vascular , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Complicaciones Posoperatorias , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del TratamientoRESUMEN
The cutaneous silent period (CSP) to noxious finger stimulation constitutes a robust spinal inhibitory reflex that protects the hand from injury. In certain conditions, spinal inhibition is interrupted by a brief burst-like electromyographic activity, dividing the CSP into two inhibitory phases (I1 and I2). This excitatory component is termed long-loop reflex (LLR) and is presumed to be transcortical in origin. Efficient defense from environmental threats requires sensorimotor integration between multimodal sensory afferents and planning of defensive movements. In the defensive peripersonal space (DPPS) immediately surrounding the body, we interact with objects and persons with increased alertness. We investigated whether CSP differs when the stimulated hand is in the DPPS of the face compared with a distant position. Furthermore, we investigated the possible role of vision in CSP modulation. Fifteen healthy volunteers underwent CSP testing with the handheld either within 5 cm from the nose (near) or away from the body (far). Recordings were obtained from first dorsal interosseous muscle following index (D2) or little finger (D5) stimulation with varying intensities. A subgroup of subjects underwent CSP recordings in near and far conditions, both with eyes open and with eyes closed. No inhibitory CSP parameter differed between stimulation in near and far conditions. LLRs occurring following D2 stimulation were significantly larger in near than far conditions at all stimulus intensities, irrespective of subjects seeing their hand. Similar to the hand-blink reflex, spinally organized protective reflexes may be modulated by corticospinal facilitatory input when the hand enters the DPPS of the face. NEW & NOTEWORTHY The present findings demonstrate for the first time that a spinally organized protective reflex, the cutaneous silent period (CSP), may be modulated by top-down corticospinal facilitatory input when the stimulated hand enters the defensive peripersonal space (DPPS) of the face. In particular, the cortically mediated excitatory long-loop reflex, which may interrupt the CSP, is facilitated when the stimulated hand is in the DPPS, irrespective of visual control over the hand. No spinal inhibitory CSP parameter differs significantly in or outside the DPPS.