Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 30(2): 1041-1044, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31529250

RESUMEN

OBJECTIVES: To assess the value of a T1-3D black-blood turbo spin echo (TSE) sequence for the diagnosis of abdominal large vessel vasculitis (LVV). MATERIALS AND METHODS: The study included 20 patients with abdominal LVV and 17 controls, who underwent a 3T-MRI scan using a modified T1-3D volumetric isotropic TSE acquisition and a segmented T1-3D turbo field echo sequence (T1-mVISTA/T1-eTHRIVE). Two radiologists independently analyzed the aorta for concentric contrast enhancement, concentric wall thickening, image quality, and flow artifact intensity (CCE/CWT/IQ/FAI; 4-point scales). The mean aortic wall thickness (MAWT) in post-contrast T1-mVISTA was compared between patients and controls. RESULTS: IQ of T1-mVISTA was rated good to excellent in 91.5% of 282 evaluated vessel segments with no or minor FAI present in 85.5%. The inter-observer reproducibility for the identification of CCE/CWT on T1-mVISTA was 0.92 and 0.93 (p < 0.001). The distribution of segmental inflammation in T1-mVISTA significantly correlated with T1-eTHRIVE (CCE, κ = 0.768; CWT, κ = 0.715; p < 0.001), resulting in a sensitivity, specificity, and positive predictive value of 100%, 81.3%, and 83.3%. The MAWT significantly differed between patients and controls (3.29 ± 0.81 vs. 2.24 ± 0.45 mm; p < 0.001). CONCLUSIONS: T1-mVISTA enables the evaluation of the MAWT and allows the detection of abdominal LVV. KEY POINTS: • 3D T1w-mVISTA accurately depicted the large abdominal vessels. • 3D T1w-mVISTA enables accurate measurements of the abdominal aortic wall thickness. • 3D T1w-mVISTA is useful for the detection of abdominal LVV.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Vasculitis/diagnóstico por imagen , Abdomen/irrigación sanguínea , Abdomen/diagnóstico por imagen , Adulto , Anciano , Aorta Abdominal/diagnóstico por imagen , Aortitis/diagnóstico por imagen , Artefactos , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Eur Radiol ; 30(2): 866-876, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31691123

RESUMEN

OBJECTIVES: To evaluate the diagnostic value of a contrast-enhanced 3D T1-weighted-modified volumetric isotropic turbo spin-echo acquisition sequence (T1-mVISTA) in comparison with a conventional 3D T1-weighted magnetization-prepared rapid gradient-echo (T1-MP-RAGE) sequence for the detection of meningeal enhancement in patients with meningitis. METHODS: Thirty patients (infectious meningitis, n = 12; neoplastic meningitis, n = 18) and 45 matched controls were enrolled in this retrospective case-control study. Sets of randomly selected T1-mVISTA and T1-MP-RAGE images (both with 0.8-mm isotropic resolution) were read separately 4 weeks apart. Image quality, leptomeningeal and dural enhancement, grading of visual contrast enhancement, and diagnostic confidence were compared using the Kruskal-Wallis rank sum test. RESULTS: Image quality was rated to be good to excellent in 75 out of 75 cases (100%) for T1-mVISTA and 74 out of 75 cases (98.7%) for T1-MP-RAGE. T1-mVISTA detected significantly more patients with leptomeningeal enhancement (p = 0.006) compared with T1-MP-RAGE (86.7 vs. 50.0%, p < 0.001), each with specificity of 100%. Similarly, sensitivity of T1-mVISTA for the detection of dural and/or leptomeningeal enhancement was also significantly higher compared with that of T1-MP-RAGE (96.7 vs. 80.0%, p = 0.025) without significant differences regarding specificity (97.8 vs. 95.6%, p = 0.317). No significant differences were found for dural enhancement alone. Diagnostic confidence in T1-mVISTA was significantly higher (p = 0.01). Visual contrast enhancement was tendentially higher in T1-mVISTA. CONCLUSIONS: T1-mVISTA may be an adequate and probably better alternative to T1-MP-RAGE for detection of leptomeningeal diseases. KEY POINTS: • Black-blood T1-mVISTA showed a significant higher sensitivity for the detection of leptomeningeal enhancement compared with MP-RAGE without losses regarding specificity. • Diagnostic confidence was assessed significantly higher in T1-mVISTA. • T1-mVISTA should be considered a supplement or an alternative to T1-MP-RAGE in patients with suspected leptomeningeal diseases.


Asunto(s)
Neoplasias Meníngeas/diagnóstico por imagen , Meningitis/diagnóstico por imagen , Adolescente , Adulto , Estudios de Casos y Controles , Niño , Preescolar , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Imagenología Tridimensional/métodos , Lactante , Imagen por Resonancia Magnética/métodos , Masculino , Neoplasias Meníngeas/secundario , Meningitis Bacterianas/diagnóstico por imagen , Meningitis Viral/diagnóstico por imagen , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
3.
Q J Nucl Med Mol Imaging ; 64(2): 194-202, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29307167

RESUMEN

BACKGROUND: We aimed to investigate the clinical value of a 3D-T1w turbo-spin-echo (TSE) sequence and [18F]fluorodeoxyglucose positron emission tomography/computed tomography ([18F]FDG-PET/CT) for the diagnosis of active large vessel vasculitis (LVV) and single-organ vasculitis (SOV) of the aorta. METHODS: Twenty-four patients with suspected vasculitis who underwent MRI and PET/CT were retrospectively evaluated. MRI was analyzed for concentric contrast enhancement and wall thickening, and flow artifact intensity (4-point-scales). PET/CT analysis comprised qualitative, quantitative and semiquantitative methods. Imaging findings were correlated with final diagnosis derived from the clinical follow-up data. RESULTS: Fifteen of 24 patients had a clinically confirmed active vasculitis, two had inactive vasculitis and 7 no vasculitis. [18F]FDG-PET/CT and 3D-T1w TSE-MRI revealed both a high diagnostic accuracy of 88% and 83%, respectively. In patients in whom both PET/CT and MRI showed concordant findings (19 patients), the accuracy increased to 95% with a high positive predictive value (92%) and negative predictive value (100%); thus, a correct diagnosis was obtained in 18 of 19 patients. Among the five patients with discordant findings PET/CT correctly identified the two patients without active vasculitis while rated false positive on MRI. Of the three remaining patients with active vasculitis, two were correctly identified by MRI and one by PET/CT. CONCLUSIONS: 3D-T1w TSE-MRI and [18F]FDG-PET/CT are both useful in the diagnosis of active vasculitis with high diagnostic accuracies. The diagnostic accuracy was even optimized by combining the two analysis methods. Therefore, there might be substantial potential for the application of whole-body hybrid PET/MRI in the evaluation of vasculitis in future studies.


Asunto(s)
Aorta/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Imagenología Tridimensional , Imagen por Resonancia Magnética , Vasculitis/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
4.
J Cardiovasc Magn Reson ; 22(1): 29, 2020 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-32354361

RESUMEN

BACKGROUND: Aortic valve repair has become a treatment option for adults with symptomatic bicuspid (BAV) or unicuspid (UAV) aortic valve insufficiency. Our aim was to demonstrate the feasibility of 4D flow cardiovascular magnetic resonance (CMR) to assess the impact of aortic valve repair on changes in blood flow dynamics in patients with symptomatic BAV or UAV. METHODS: Twenty patients with adult congenital heart disease (median 35 years, range 18-64; 16 male) and symptomatic aortic valve regurgitation (15 BAV, 5 UAV) were prospectively studied. All patients underwent 4D flow CMR before and after aortic valve repair. Aortic valve regurgitant fraction and systolic peak velocity were estimated. The degree of helical and vortical flow was evaluated according to a 3-point scale. Relative flow displacement and wall shear stress (WSS) were quantified at predefined levels in the thoracic aorta. RESULTS: All patients underwent successful aortic valve repair with a significant reduction of aortic valve regurgitation (16.7 ± 9.8% to 6.4 ± 4.4%, p < 0.001) and systolic peak velocity (2.3 ± 0.9 to 1.9 ± 0.4 m/s, p = 0.014). Both helical flow (1.6 ± 0.6 vs. 0.9 ± 0.5, p < 0.001) and vortical flow (1.2 ± 0.8 vs. 0.5 ± 0.6, p = 0.002) as well as both flow displacement (0.3 ± 0.1 vs. 0.25 ± 0.1, p = 0.031) and WSS (0.8 ± 0.2 N/m2 vs. 0.5 ± 0.2 N/m2, p < 0.001) in the ascending aorta were significantly reduced after aortic valve repair. CONCLUSIONS: 4D flow CMR allows assessment of the impact of aortic valve repair on changes in blood flow dynamics in patients with bicuspid aortic valve disease.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Aortografía , Anuloplastia de la Válvula Cardíaca , Enfermedades de las Válvulas Cardíacas/cirugía , Hemodinámica , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Adulto , Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
5.
Magn Reson Med ; 79(1): 407-415, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28261861

RESUMEN

PURPOSE: To design a preparation module for vessel signal suppression in MR neurography of the extremities, which causes minimal attenuation of nerve signal and is highly insensitive to eddy currents and motion. METHODS: The orthogonally combined motion- and diffusion-sensitized driven equilibrium (OC-MDSDE) preparation was proposed, based on the improved motion- and diffusion-sensitized driven equilibrium methods (iMSDE and FC-DSDE, respectively), with specific gradient design and orientation. OC-MDSDE was desensitized against eddy currents using appropriately designed gradient prepulses. The motion sensitivity and vessel signal suppression capability of OC-MDSDE and its components were assessed in vivo in the knee using 3D turbo spin echo (TSE). Nerve-to-vessel signal ratios were measured for iMSDE and OC-MDSDE in 7 subjects. RESULTS: iMSDE was shown to be highly sensitive to motion with increasing flow sensitization. FC-DSDE showed robustness against motion, but resulted in strong nerve signal loss with diffusion gradients oriented parallel to the nerve. OC-MDSDE showed superior vessel suppression compared to iMSDE and FC-DSDE and maintained high nerve signal. Mean nerve-to-vessel signal ratios in 7 subjects were 0.40 ± 0.17 for iMSDE and 0.63 ± 0.37 for OC-MDSDE. CONCLUSION: OC-MDSDE combined with 3D TSE in the extremities allows high-near-isotropic-resolution imaging of peripheral nerves with reduced vessel contamination and high nerve signal. Magn Reson Med 79:407-415, 2018. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Imagen por Resonancia Magnética , Nervios Periféricos/diagnóstico por imagen , Adulto , Algoritmos , Artefactos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados
6.
J Cardiovasc Magn Reson ; 20(1): 17, 2018 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-29530064

RESUMEN

BACKGROUND: Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. METHODS: Fifteen fetuses (gestational age 30-39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. RESULTS: Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57-0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). CONCLUSION: High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Ecocardiografía Doppler , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Ultrasonografía Prenatal/métodos , Boston , Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Ecocardiografía Doppler/instrumentación , Diseño de Equipo , Corazón Fetal/fisiopatología , Alemania , Edad Gestacional , Cardiopatías Congénitas/embriología , Cardiopatías Congénitas/fisiopatología , Frecuencia Cardíaca Fetal , Humanos , Imagen por Resonancia Cinemagnética/instrumentación , Valor Predictivo de las Pruebas , Volumen Sistólico , Suecia , Transductores , Ultrasonografía Prenatal/instrumentación , Función Ventricular Izquierda
7.
J Comput Assist Tomogr ; 42(4): 574-579, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29613984

RESUMEN

OBJECTIVE: The assessment of fatty infiltration and edema in the musculature of patients with neuromuscular diseases (NMDs) typically requires the separate performance of T1-weighted and fat-suppressed T2-weighted sequences. T2-weighted Dixon turbo spin echo (TSE) enables the generation of T2-weighted fat- and water-separated images, which can be used to assess both pathologies simultaneously. The present study examines the diagnostic performance of T2-weighted Dixon TSE compared with the standard sequences in 10 patients with NMDs and 10 healthy subjects. METHODS: Whole-body magnetic resonance imaging was performed including T1-weighted Dixon fast field echo, T2-weighted short-tau inversion recovery, and T2-weighted Dixon TSE. Fatty infiltration and intramuscular edema were rated by 2 radiologists using visual semiquantitative rating scales. To assess intermethod and interrater agreement, weighted Cohen's κ coefficients were calculated. RESULTS: The ratings of fatty infiltration showed high intermethod and high interrater agreement (T1-weighted Dixon fast field echo vs T2-weighted Dixon TSE fat image). The evaluation of edematous changes showed high intermethod and good interrater agreement (T2-weighted short-tau inversion recovery vs T2-weighted Dixon TSE water image). CONCLUSIONS: T2-weighted Dixon TSE imaging is an alternative for accelerated simultaneous grading of whole-body skeletal muscle fat infiltration and edema in patients with NMDs.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Edema/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Músculo Esquelético/diagnóstico por imagen , Enfermedades Neuromusculares/diagnóstico por imagen , Imagen de Cuerpo Entero/métodos , Edema/complicaciones , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Enfermedades Neuromusculares/complicaciones , Reproducibilidad de los Resultados
8.
Acta Radiol ; 59(5): 560-568, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-28795588

RESUMEN

Background Diffusion tensor imaging (DTI) of peripheral nerves may provide additional information about nerve involvement in muscular disorders, but is considered difficult due to different optimal scan parameters tailored to magnetic resonance (MR) signal properties of muscle and neural tissues. Purpose To assess the feasibility of sciatic nerve DTI using two different approaches of region of interest (ROI)-localization in DTI scans with b-values 500 s/mm2, in participants with muscular disorders and in controls. Material and Methods DTI of the thigh was conducted on a 3T system in ten patients (6 men, 4 women; mean age =54 ± 15 years) with neuromuscular disorders and ten controls. T1-weighted (T1W) images were co-registered to fractional anisotropy (FA) color-encoded images. The apparent diffusion coefficient (ADC), FA, and fiber track length (FTL) were analyzed by two operators using a freehand ROI and a single-point ROI covering the sciatic nerve. Interclass correlation coefficient (ICC) and Bland-Altman analysis were used for evaluation of inter-operator and inter-technical agreement, respectively. Results Three-dimensional visualization of sciatic nerve fiber was achievable using both techniques. The ICC of DTI metrics showed excellent inter-operator agreement both in patients and controls. Bland-Altman analysis revealed good agreement of both techniques. A maximum FTL was achieved using the single-point ROI technique, but with a lower inter-operator agreement (ICC = 0.99 vs. 0.83). The ADC and maximum FTL were significantly decreased in patients compared to controls. Conclusion Both ROI localization techniques are feasible to analyze the sciatic nerve in the setting of muscular disease. A maximum FTL is reached using the single-point ROI, however, at the cost of lower inter-operator agreement.


Asunto(s)
Imagen de Difusión Tensora/métodos , Distrofias Musculares/diagnóstico por imagen , Miositis por Cuerpos de Inclusión/diagnóstico por imagen , Nervio Ciático/diagnóstico por imagen , Anisotropía , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Muslo/diagnóstico por imagen
9.
Magn Reson Med ; 78(4): 1432-1441, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-27851874

RESUMEN

PURPOSE: To remove the confounding effect of unsuppressed fat on the imaging-based apparent diffusion coefficient (ADC) of the vertebral bone marrow water component when using spectrally selective fat suppression and to compare and validate the proposed quantification strategy against diffusion-weighted magnetic resonance spectroscopy (DW-MRS). METHODS: Twelve subjects underwent diffusion-weighted imaging (DWI) and DW-MRS of the vertebral bone marrow. A theoretical model was developed to take into account and correct the effects of residual fat on ADC, incorporating additional measurements for proton density fat fraction (PDFF) and water T2 (T2w ). Uncorrected and corrected DWI-based ADC was compared with DW-MRS-based ADC using the Bland-Altman method. RESULTS: There was a systematic bias equal to 0.118 ± 0.116 × 10-3 mm2 /s between DWI and DW-MRS when no correction was performed. Taking into account measured PDFF and constant T2w reduced the bias to 0.006 ± 0.128 × 10-3 mm2 /s. Using the proposed approach with both individually measured PDFF and T2w reduced both the bias and the limits of agreement between DWI and DW-MRS (0.018 ± 0.065 × 10-3 mm2 /s). CONCLUSION: By taking into account the presence of residual fat in a modified signal model that incorporates additional individual measurements of PDFF and T2w , good agreement of imaging-based ADC with MRS-based ADC can be achieved in vertebral bone marrow. Magn Reson Med 78:1432-1441, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Médula Ósea/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Columna Vertebral/diagnóstico por imagen , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Adulto Joven
10.
Magn Reson Med ; 78(1): 264-270, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-27509836

RESUMEN

PURPOSE: We aimed to determine the agreement between quantitative susceptibility mapping (QSM)-based biomagnetic liver susceptometry (BLS) and confounder-corrected R2* mapping with superconducting quantum interference device (SQUID)-based biomagnetic liver susceptometry in patients with liver iron overload. METHODS: Data were acquired from two healthy controls and 22 patients undergoing MRI and SQUID-BLS as part of routine monitoring for iron overload. Magnetic resonance imaging was performed on a 3T system using a three-dimensional multi-echo gradient-echo acquisition. Both magnetic susceptibility and R2* of the liver were estimated from this acquisition. Linear regression was used to compare estimates of QSM-BLS and R2* to SQUID-BLS. RESULTS: Both QSM-BLS and confounder-corrected R2* were sensitive to the presence of iron in the liver. Linear regression between QSM-BLS and SQUID-BLS demonstrated the following relationship: QSM-BLS = (-0.22 ± 0.11) + (0.49 ± 0.05) · SQUID-BLS with r2 = 0.88. The coefficient of determination between liver R2* and SQUID-BLS was also r2 = 0.88. CONCLUSION: We determined a strong correlation between both QSM-BLS and confounder-corrected R2* to SQUID-BLS. This study demonstrates the feasibility of QSM-BLS and confounder-corrected R2* for assessing liver iron overload, particularly when SQUID systems are not accessible. Magn Reson Med 78:264-270, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Sobrecarga de Hierro/diagnóstico por imagen , Sobrecarga de Hierro/metabolismo , Hierro/metabolismo , Hepatopatías/diagnóstico por imagen , Hepatopatías/metabolismo , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Aumento de la Imagen/métodos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Imagen Molecular/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
11.
Magn Reson Med ; 78(3): 984-996, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27797100

RESUMEN

PURPOSE: To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS: A three-step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time-interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field-induced PDFF bias and the performance estimating the phase offset between time-interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. RESULTS: The simulation, phantom, and in vivo results showed in agreement with the theory an echo time-dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. CONCLUSION: Complex-based time-interleaved water-fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984-996, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tejido Adiposo/diagnóstico por imagen , Simulación por Computador , Humanos , Hígado/diagnóstico por imagen , Fantasmas de Imagen
12.
NMR Biomed ; 30(11)2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28777496

RESUMEN

The purpose of this work was to investigate the performance of the modified BIR-4 T2 preparation for T2 mapping and propose a method to remove T2 quantification errors in the presence of large B1 and B0 offsets. The theoretical investigation of the magnetization evolution during the T2 preparation in the presence of B1 and B0 offsets showed deviations from a mono-exponential T2 decay (two parameter fit). A three parameter fit was used to improve T2 accuracy. Furthermore, a two parameter fit with an additional saturation preparation scan was proposed to improve T2 accuracy and precision. These three fitting methods were compared based on simulations, phantom measurements and an in vivo healthy volunteer study of the neck musculature using a 3D TSE readout. The results based upon the pure two parameter fit overestimated T2 in regions with high B0 offsets (up to 40% in phantoms). The three parameter fit T2 values were robust to B0 offsets but with higher standard deviation (up to 40% in simulations). The two parameter fit with the saturation preparation yielded high robustness towards B0 offsets with a noise performance comparable to that of the two parameter fit. In the volunteer study the T2 values obtained by the pure two parameter fit showed a dependence on the field inhomogeneities, whereas the T2 values from the proposed fitting approach were shown to be insensitive to B0 offsets. The proposed method enabled accurate and precise T2 mapping in the presence of large B1 and B0 offsets.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Adulto , Humanos , Fantasmas de Imagen
13.
Magn Reson Med ; 75(1): 32-41, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25753506

RESUMEN

PURPOSE: To propose and optimize diffusion-weighted stimulated echo acquisition mode (DW-STEAM) for measuring fat unsaturation in the presence of a strong water signal by suppressing the water signal based on a shorter T2 and higher diffusivity of water relative to fat. METHODS: A parameter study for point-resolved spectroscopy (PRESS) and STEAM using oil phantoms was performed and correlated with gas chromatography (GC). Simulations of muscle tissue signal behavior using DW-STEAM and long-echo time (TE) PRESS and a parameter optimization for DW-STEAM were conducted. DW-STEAM and long-TE PRESS were applied in the gastrocnemius muscles of nine healthy subjects. RESULTS: STEAM with TE and mixing time (TM) up to 45 ms exhibited R(2) correlations above 0.98 with GC and little T2 -weighting and J-modulation for the quantified olefinic/methylene peak ratio. The optimal parameters for muscle tissue using DW-STEAM were b-value = 1800 s/mm(2), TE = 33 ms, TM = 30 ms, and repetition time = 2300 ms. In vivo measured mean olefinic signal-to-noise ratios were 72 and 40, mean apparent olefinic water fractions were 0.19 and 0.11 for DW-STEAM and long-TE PRESS, respectively. CONCLUSION: Optimized DW-STEAM MR spectroscopy is superior to long-TE PRESS for measuring fat unsaturation, if a strong water peak prevents the olefinic fat signal's quantification at shorter TEs and water's tissue specific ADC is substantially higher than fat.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Grasas Insaturadas/metabolismo , Músculo Esquelético/anatomía & histología , Músculo Esquelético/metabolismo , Espectroscopía de Protones por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular
14.
J Magn Reson Imaging ; 43(4): 789-99, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26454005

RESUMEN

PURPOSE: To study the effects of refocusing angle modulation with 3D turbo spin echo (TSE) on signal and sharpness of small oblique nerves embedded in muscle and suppressed fat in the lumbar plexus. MATERIALS AND METHODS: Flip angle trains were generated with extended phase graphs (EPG) for a sequence parameter subspace. Signal loss and width broadening were simulated for a single-pixel nerve embedded in muscle and suppressed fat to prescribe a flip angle modulation that gives the best compromise between signal and sharpness of small nerves. Two flip angle trains were defined based on the simulations of small embedded nerves: design denoted A, predicting maximum global signal, and design denoted B, predicting maximum signal for minimum width broadening. In vivo data of the lumbar plexus in 10 healthy volunteers was acquired at 3.0T with 3D TSE employing flip angle trains A and B. Quantitative and qualitative analyses of the acquired data were made to assess changes in width and signal intensity. RESULTS: Changing flip angle modulation from A to B resulted in: 1) average signal losses of 23% in (larger) L5 nerves and 9% in (smaller) L3 nerves; 2) average width reductions of 4% in L5 nerves and of 16% in L3 nerves; and 3) statistically significant sharpness improvement (P = 0.005) in L3 nerves. CONCLUSION: An optimized flip angle train in 3D TSE imaging of the lumbar plexus considering geometry-specific blurring effects from both the nerve and the surrounding tissue can improve the delineation of small nerves.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Plexo Lumbosacro/diagnóstico por imagen , Músculos/diagnóstico por imagen , Tejido Adiposo/diagnóstico por imagen , Adulto , Algoritmos , Simulación por Computador , Femenino , Voluntarios Sanos , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino
15.
J Comput Assist Tomogr ; 40(3): 447-51, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26953765

RESUMEN

Magnetic resonance-based assessment of quadriceps muscle fat has been proposed as surrogate marker in sarcopenia, osteoarthritis, and neuromuscular disorders. We presently investigated the association of quadriceps muscle fat with isometric strength measurements in healthy males using chemical shift encoding-based water-fat magnetic resonance imaging. Intermuscular adipose tissue fraction and intramuscular proton density fat fraction correlated significantly (P < 0.05) with isometric strength (up to r = -0.83 and -0.87, respectively). Reproducibility of intermuscular adipose tissue fraction and intramuscular proton density fat fraction was 1.5% and 5.7%, respectively.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Grasa Intraabdominal/fisiología , Contracción Isométrica/fisiología , Imagen por Resonancia Magnética , Fuerza Muscular/fisiología , Músculo Cuádriceps/diagnóstico por imagen , Músculo Cuádriceps/fisiología , Adiposidad/fisiología , Adulto , Agua Corporal/diagnóstico por imagen , Agua Corporal/fisiología , Humanos , Grasa Intraabdominal/diagnóstico por imagen , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
NMR Biomed ; 28(11): 1535-42, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26423583

RESUMEN

Bone marrow fat fraction mapping using chemical shift encoding-based water-fat separation is becoming a useful tool in investigating the association between bone marrow adiposity and bone health and in assessing cancer treatment-induced bone marrow damage. Vertebral bone marrow is characterized by short T2* relaxation times, which are in general different for the water and fat components and can confound fat quantification. The purpose of the present study is to compare different approaches to T2* correction in chemical shift encoding-based water-fat imaging of vertebral bone marrow using single-voxel MRS as reference. Eight-echo gradient-echo imaging and single-voxel MRS measurements were made on the spine (L3-L5) of 25 healthy volunteers. Different approaches were evaluated for correction of T2* effects: (a) single-T2* correction, (b) dual-T2* correction, (c) T2' correction using the a priori-known T2 from the MRS at each vertebral body and (d) T2' correction using the a priori-known T2 equal to previously measured average values. Dual-T2* correction resulted in noisier imaging fat fraction maps than single-T2* correction or T2' correction using a priori-known T2. Linear regression analysis between imaging and MRS fat fraction showed a slope significantly different from 1 when using single-T2* correction (R(2) = 0.96) or dual-T2* correction (R(2) = 0.87). T2' correction using the a priori-known T2 resulted in a slope not significantly different from 1, an intercept significantly different from 0 (between 2.4% and 3%) and R(2) = 0.96. Therefore, a T2' correction using a priori-known T2 can remove the fat fraction bias induced by the difference in T2* between water and fat components without degrading noise performance in fat fraction mapping of vertebral bone marrow.


Asunto(s)
Tejido Adiposo/fisiología , Adiposidad/fisiología , Médula Ósea/fisiología , Vértebras Lumbares/fisiología , Imagen por Resonancia Magnética/métodos , Modelos Biológicos , Tejido Adiposo/anatomía & histología , Adulto , Médula Ósea/anatomía & histología , Simulación por Computador , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Vértebras Lumbares/anatomía & histología , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
NMR Biomed ; 28(4): 432-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25683154

RESUMEN

Vertebral bone marrow fat quantification using single-voxel MRS is confounded by overlapping water-fat peaks and the difference in T2 relaxation time between water and fat components. The purposes of the present study were: (i) to determine the proton density fat fraction (PDFF) of vertebral bone marrow using single-voxel multi-TE MRS, addressing these confounding effects; and (ii) to investigate the implications of these corrections with respect to the age dependence of the PDFF. Single-voxel MRS was performed in the L5 vertebral body of 86 subjects (54 women and 32 men). To reliably extract the water peak from the overlying fat peaks, the mean bone marrow fat spectrum was characterized based on the area of measurable fat peaks and an a priori knowledge of the chemical triglyceride structure. MRS measurements were performed at multiple TEs. The T2 -weighted fat fraction was calculated at each TE. In addition, a T2 correction was performed to obtain the PDFF and the T2 value of water (T2w ) was calculated. The implications of the T2 correction were investigated by studying the age dependence of the T2 -weighted fat fractions and the PDFF. Compared with the PDFF, all T2 -weighted fat fractions significantly overestimated the fat fraction. Compared with the age dependence of the PDFF, the age dependence of the T2 -weighted fat fraction showed an increased slope and intercept as TE increased for women and a strongly increased intercept as TE increased for men. For women, a negative association between the T2 value of bone marrow water and PDFF was found. Single-voxel MRS-based vertebral bone marrow fat quantification should be based on a multi-TE MRS measurement to minimize confounding effects on PDFF determination, and also to allow the simultaneous calculation of T2w , which might be considered as an additional parameter sensitive to the composition of the water compartment.


Asunto(s)
Tejido Adiposo/anatomía & histología , Adiposidad , Envejecimiento/fisiología , Médula Ósea/anatomía & histología , Vértebras Lumbares/anatomía & histología , Espectroscopía de Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Agua Corporal , Femenino , Humanos , Vértebras Lumbares/química , Masculino , Persona de Mediana Edad , Caracteres Sexuales , Triglicéridos/análisis , Adulto Joven
18.
J Magn Reson Imaging ; 41(1): 110-6, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24357078

RESUMEN

PURPOSE: To calculate regional fetal brain oxygen saturation (sO2) during hypoxia in sheep. MATERIALS AND METHODS: Eight pregnant ewes were examined at a 3T MR-scanner using blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) to measure signal intensity changes of the fetal brain during a control period and a period of induced hypoxia. Regions of interest were placed in the fetal cerebrum to assess ΔR2* from GRE signal intensity plateaus (S(control), S(hypoxia)) and the relation between ΔR2* and ΔpO2 was analyzed. A probe was placed surgically in the fetal brain to directly measure local pO2 as a reference standard. Baseline and hypoxic pO2 values were recorded and compared (ΔpO2). RESULTS: Mean fetal brain pO2 decreased from 14.3 mmHg (95% confidence interval [CI]: 10-19) to 3.4 mmHg (95% CI: 2-5) during hypoxia (mean ΔpO2 = 10.9 mmHg and ΔR2* = -5s(-1)). A significant correlation between ΔR2* and ΔpO2 was noted (r = 0.93, P < 0.001), and conversion of pO2 into sO2 resulted in a linear regression coefficient of (-0.14 ± 0.01)s(-1)/% (r(2) = 0.91). CONCLUSION: Measured fetal brain BOLD-MRI was compared and converted to pO2, followed by calculation of cerebral sO2.


Asunto(s)
Encéfalo/patología , Hipoxia Fetal/patología , Imagen por Resonancia Magnética/métodos , Animales , Femenino , Feto , Embarazo
19.
J Magn Reson Imaging ; 42(4): 1018-23, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25639780

RESUMEN

BACKGROUND: The assessment of bone marrow composition has recently gained significant attention due to its association with bone loss pathophysiology and cancer therapy-induced bone marrow damage. The purpose of our study was to investigate the anatomical variation of the vertebral bone marrow fat using chemical shift-encoding based water-fat MRI and to assess the repeatability of these measurements. METHODS: Chemical shift-encoding based water-fat MRI of the whole spine was performed in 28 young, healthy subjects (17 males, 11 females, 26 ± 4 years). Six subjects were scanned three times with repositioning to assess the repeatability of these measurements. Proton density fat fraction (PDFF) maps were computed and manually segmented to obtain PDFF of C3-L5. RESULTS: Mean PDFF of all subjects significantly increased from C3 to L5 (P < 0.05) with r = 0.88 (P < 0.05). PDFF averaged over C3-7, T1-6, T7-12, and L1-5 of males and females amounted to 31.7 ± 7.9% and 23.0 ± 7.8% (P = 0.002), 33.8 ± 6.8% and 24.6 ± 8.8% (P = 0.005), 33.8 ± 6.4% and 26.1 ± 6.4% (P = 0.023), and 38.8 ± 7.6% and 31.5 ± 12.4% (P = 0.063), respectively. The repeatability for PDFF measurements expressed as absolute precision error was 1.7% averaged over C3-L5. CONCLUSION: Whole spine vertebral bone marrow fat could be reproducibly assessed by using chemical shift-encoding based water-fat MRI and showed anatomical variations.


Asunto(s)
Tejido Adiposo/anatomía & histología , Médula Ósea/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Columna Vertebral/anatomía & histología , Tejido Adiposo/fisiología , Adiposidad/fisiología , Adulto , Algoritmos , Médula Ósea/fisiología , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Columna Vertebral/fisiología , Agua/análisis , Imagen de Cuerpo Entero , Adulto Joven
20.
J Magn Reson Imaging ; 42(5): 1272-80, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25865456

RESUMEN

PURPOSE: To determine changes in the bone marrow fat fraction (BMFF) in obesity after dietary intervention in comparison with changes in abdominal fat, liver fat, and serum lipids. MATERIALS AND METHODS: Twenty obese (BMI 34.92 ± 3.8 kg/m(2) ) women participated in a 4-week dietary intervention of 800 kcal/d plus additional vegetables. They underwent anthropometric and blood value measurements before and after the intervention. Abdominal 3T MRI was performed to measure changes in subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) volume and single-voxel magnetic resonance spectroscopy (MRS) to measure fat content changes in the liver and L5 vertebral body. RESULTS: The greatest relative change after dietary intervention was found in the liver (-40.3%), followed by VAT volume (-15.1%), serum lipids (-12.6 to -14.5%), and SAT volume (-8.5%). There were no statistically significant changes in BMFF after dietary intervention (P = 0.39), but absolute changes in the BMFF were positively associated with SAT volume (r = 0.489) and negatively associated with nonadipose tissue volume (r = -0.493) before dietary intervention. CONCLUSION: Bone marrow behaves differently compared to SAT volume, VAT volume, liver fat, and serum lipids after a 4-week dietary intervention in obesity and BMFF changes depend on abdominal tissue volumes before intervention.


Asunto(s)
Grasa Abdominal/patología , Médula Ósea/patología , Restricción Calórica , Hígado Graso/patología , Imagen por Resonancia Magnética , Obesidad/dietoterapia , Obesidad/patología , Tejido Adiposo/patología , Hígado Graso/complicaciones , Femenino , Humanos , Hígado/patología , Persona de Mediana Edad , Obesidad/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA